메뉴 건너뛰기




Volumn 37, Issue 8, 2012, Pages

Accuracy of robot-assisted placement of lumbar and sacral pedicle screws: A prospective randomized comparison to conventional freehand screw implantation

Author keywords

computer assisted surgery; image guidance; lumbar lumbosacral spinal instrumentation; pedicle screws; robotics

Indexed keywords

ACCURACY; AGED; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; FLUOROSCOPY; HUMAN; INTERMETHOD COMPARISON; IRRADIATION; LUMBOSACRAL SPINE; MAJOR CLINICAL STUDY; MALE; OPERATING ROOM; ORTHOPEDIC SURGERY; PEDICLE SCREW; PRIORITY JOURNAL; ROBOTICS;

EID: 84859955993     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/BRS.0b013e31824b7767     Document Type: Article
Times cited : (293)

References (20)
  • 1
    • 33846683025 scopus 로고    scopus 로고
    • Pedicle screw placement accuracy: A meta-analysis
    • DOI 10.1097/01.brs.0000254048.79024.8b, PII 0000763220070201000022
    • Kosmopoulos V, Schizas C. Pedicle screw placement accuracy: a meta-analysis. Spine (Phila Pa 1976) 2007; 32: E111-20. (Pubitemid 46197463)
    • (2007) Spine , vol.32 , Issue.3
    • Kosmopoulos, V.1    Schizas, C.2
  • 2
    • 75049084141 scopus 로고    scopus 로고
    • Image-guided spine surgery: State of the art and future directions
    • Tjardes T, Shafi zadeh S, Rixen D, et al. Image-guided spine surgery: state of the art and future directions. Eur Spine J 2010; 19: 25-45.
    • (2010) Eur Spine J , vol.19 , pp. 25-45
    • Tjardes, T.1    Shafi Zadeh, S.2    Rixen, D.3
  • 3
    • 0033834616 scopus 로고    scopus 로고
    • Accuracy of pedicle screw insertion with and without computer assistance: A randomised controlled clinical study in 100 consecutive patients
    • Laine T, Lund T, Ylikoski M, et al. Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Eur Spine J 2000; 9: 235-40.
    • (2000) Eur Spine J , vol.9 , pp. 235-240
    • Laine, T.1    Lund, T.2    Ylikoski, M.3
  • 4
    • 33846239956 scopus 로고    scopus 로고
    • Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries
    • DOI 10.1097/01.brs.0000252094.64857.ab, PII 0000763220070115000030
    • Rajasekaran S, Vidyadhara S, Ramesh P, et al. Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine (Phila Pa 1976) 2007; 32: E56-64. (Pubitemid 46105794)
    • (2007) Spine , vol.32 , Issue.2
    • Rajasekaran, S.1    Vidyadhara, S.2    Ramesh, P.3    Shetty, A.P.4
  • 5
    • 45949103909 scopus 로고    scopus 로고
    • Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally invasive spine surgery
    • DOI 10.1016/j.spinee.2006.12.012, PII S1529943007000034
    • Kim CW, Lee YP, Taylor W, et al. Use of navigation-assisted fl uoroscopy to decrease radiation exposure during minimally invasive spine surgery. Spine J 2008; 8: 584-90. (Pubitemid 351893122)
    • (2008) Spine Journal , vol.8 , Issue.4 , pp. 584-590
    • Kim, C.W.1    Lee, Y.-P.2    Taylor, W.3    Oygar, A.4    Kim, W.K.5
  • 6
    • 58149291992 scopus 로고    scopus 로고
    • Comparison of radiation exposure in lumbar pedicle screw placement with fl uoroscopy vs computer-assisted image guidance with intraoperative three-dimensional imaging
    • Smith HE, Welsch MD, Sasso RC, et al. Comparison of radiation exposure in lumbar pedicle screw placement with fl uoroscopy vs computer-assisted image guidance with intraoperative three-dimensional imaging. J Spinal Cord Med 2008; 31: 532-7.
    • (2008) J Spinal Cord Med , vol.31 , pp. 532-537
    • Smith, H.E.1    Welsch, M.D.2    Sasso, R.C.3
  • 7
    • 77951736379 scopus 로고    scopus 로고
    • Improving accuracy and reducing radiation exposure in minimally invasive lumbar interbody fusion
    • Wood MJ, Mannion RJ. Improving accuracy and reducing radiation exposure in minimally invasive lumbar interbody fusion. J Neurosurg Spine 2010; 12: 533-9.
    • (2010) J Neurosurg Spine , vol.12 , pp. 533-539
    • Wood, M.J.1    Mannion, R.J.2
  • 8
    • 54949150225 scopus 로고    scopus 로고
    • Robotic assisted spine surgery - A breakthrough or a surgical toy ?
    • Barzilay Y, Kaplan L, Libergall M. Robotic assisted spine surgery- a breakthrough or a surgical toy ? Int J Med Robot 2008; 4: 195-6.
    • (2008) Int J Med Robot , vol.4 , pp. 195-196
    • Barzilay, Y.1    Kaplan, L.2    Libergall, M.3
  • 9
    • 33750075179 scopus 로고    scopus 로고
    • Miniature robotic guidance for spine surgery - Introduction of a novel system and analysis of challenges encountered during the clinical development phase at two spine centres
    • DOI 10.1002/rcs.90
    • Barzilay Y, Liebergall M, Fridlander A, et al. Miniature robotic guidance for spine surgery-introduction of a novel system and analysis of challenges encountered during the clinical development phase at two spine centres. Int J Med Robot 2006; 2: 146-53. (Pubitemid 44580033)
    • (2006) International Journal of Medical Robotics and Computer Assisted Surgery , vol.2 , Issue.2 , pp. 146-153
    • Barzilay, Y.1    Liebergall, M.2    Fridlander, A.3    Knoller, N.4
  • 10
    • 33748579924 scopus 로고    scopus 로고
    • Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: Part I - Technical development and a test case result
    • DOI 10.1227/01.NEU.0000229055.00829.5B, PII 0000612320060900000017
    • Lieberman IH, Togawa D, Kayanja MM, et al. Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: part I-technical development and a test case result. Neurosurgery 2006; 59: 641-50; discussion: 50. (Pubitemid 44368160)
    • (2006) Neurosurgery , vol.59 , Issue.3 , pp. 641-650
    • Lieberman, I.H.1    Togawa, D.2    Kayanja, M.M.3    Reinhardt, M.K.4    Friedlander, A.5    Knoller, N.6    Benzel, E.C.7
  • 11
    • 64749091332 scopus 로고
    • Percutaneous placement of pedicle screws in the lumbar spine using a bone mounted miniature robotic system: Fi rst experiences and accuracy of screw placement
    • Pechlivanis I, Kiriyanthan G, Engelhardt M, et al. Percutaneous placement of pedicle screws in the lumbar spine using a bone mounted miniature robotic system: fi rst experiences and accuracy of screw placement. Spine (Phila Pa 1976) 2009; 34: 392-8.
    • (1976) Spine (Phila Pa , vol.34 , pp. 392-398
    • Pechlivanis, I.1    Kiriyanthan, G.2    Engelhardt, M.3
  • 14
    • 33847004722 scopus 로고    scopus 로고
    • Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: Part 2-evaluation of system accuracy
    • discussion ONS39
    • Togawa D, Kayanja MM, Reinhardt MK, et al. Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: part 2-evaluation of system accuracy. Neurosurgery 2007; 60: ONS129-39; discussion ONS39.
    • (2007) Neurosurgery , vol.60
    • Togawa, D.1    Kayanja, M.M.2    Reinhardt, M.K.3
  • 15
    • 1642457385 scopus 로고
    • Feasibility study of a mini, bone-attached, robotic system for spinal operations: Analysis and experiments
    • Wolf A, Shoham M, Michael S, et al. Feasibility study of a mini, bone-attached, robotic system for spinal operations: analysis and experiments. Spine (Phila Pa 1976) 2004; 29: 220-8.
    • (1976) Spine (Phila Pa , vol.29 , pp. 220-228
    • Wolf, A.1    Shoham, M.2    Michael, S.3
  • 17
    • 79952277212 scopus 로고    scopus 로고
    • Robotic technology in spine surgery- current applications and future developments
    • Staer C, Ringel F, Stoffel M, et al. Robotic technology in spine surgery- current applications and future developments. Acta Neurochir Suppl 2011; 109: 241-5.
    • (2011) Acta Neurochir Suppl , vol.109 , pp. 241-245
    • Staer, C.1    Ringel, F.2    Stoffel, M.3
  • 18
    • 0025267440 scopus 로고
    • Accuracy of pedicular screw placement in vivo
    • Gertzbein SD, Robbins SE. Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976) 1990; 15: 11-4.
    • (1976) Spine (Phila Pa , vol.15 , pp. 11-14
    • Gertzbein, S.D.1    Robbins, S.E.2
  • 19
    • 0343526789 scopus 로고
    • Radiation exposure during fl uoroscopically assisted pedicle screw insertion in the lumbar spine
    • Jones DP, Robertson PA, Lunt B, et al. Radiation exposure during fl uoroscopically assisted pedicle screw insertion in the lumbar spine. Spine (Phila Pa 1976) 2000; 25: 1538-41.
    • (1976) Spine (Phila Pa , vol.25 , pp. 1538-1541
    • Jones, D.P.1    Robertson, P.A.2    Lunt, B.3
  • 20
    • 3242676907 scopus 로고
    • Estimation of patient dose and associated radiogenic risks from fl uoroscopically guided pedicle screw insertion
    • Perisinakis K, Theocharopoulos N, Damilakis J, et al. Estimation of patient dose and associated radiogenic risks from fl uoroscopically guided pedicle screw insertion. Spine (Phila Pa 1976) 2004; 29: 1555-60.
    • (1976) Spine (Phila Pa , vol.29 , pp. 1555-1560
    • Perisinakis, K.1    Theocharopoulos, N.2    Damilakis, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.