메뉴 건너뛰기




Volumn 41, Issue 4, 2014, Pages

Monte Carlo simulation of a quantum noise limited Čerenkov detector based on air-spaced light guiding taper for megavoltage x-ray imaging

Author keywords

erenkov effect; EPID; Monte Carlo simulation

Indexed keywords

CLADDING (COATING); COMPUTERIZED TOMOGRAPHY; EFFICIENCY; IMAGE RESOLUTION; LIGHT; LINEAR ACCELERATORS; MAGNETIC RESONANCE IMAGING; MONTE CARLO METHODS; OPTICAL FIBERS; QUANTUM NOISE; RADIOTHERAPY; REFRACTIVE INDEX; X RAY DETECTORS;

EID: 84896537061     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4867867     Document Type: Article
Times cited : (4)

References (52)
  • 2
    • 0035018405 scopus 로고    scopus 로고
    • Clinical use of electronic portal imaging: Report of AAPM Radiation Therapy Committee Task Group 58
    • 10.1118/1.1368128
    • M. G. Herman, J. M. Balter, D. A. Jaffray, K. P. McGee, P. Munro, S. Shalev, M. V. Herk, and J. W. Wong, "Clinical use of electronic portal imaging: Report of AAPM Radiation Therapy Committee Task Group 58," Med. Phys. 28, 712-737 (2001). 10.1118/1.1368128
    • (2001) Med. Phys. , vol.28 , pp. 712-737
    • Herman, M.G.1    Balter, J.M.2    Jaffray, D.A.3    McGee, K.P.4    Munro, P.5    Shalev, S.6    Herk, M.V.7    Wong, J.W.8
  • 3
    • 0036680147 scopus 로고    scopus 로고
    • Flat-panel cone-beam computed tomography for image-guided radiation therapy
    • 10.1016/S0360-3016(02)02884-5
    • D. A. Jaffray, J. H. Siewerdsen, J. W. Wong, and A. A. Martinez, "Flat-panel cone-beam computed tomography for image-guided radiation therapy," Int. J. Radiat. Oncol., Biol., Phys. 53, 1337-1349 (2002). 10.1016/S0360-3016(02)02884-5
    • (2002) Int. J. Radiat. Oncol., Biol., Phys. , vol.53 , pp. 1337-1349
    • Jaffray, D.A.1    Siewerdsen, J.H.2    Wong, J.W.3    Martinez, A.A.4
  • 5
    • 66449118760 scopus 로고    scopus 로고
    • First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system
    • 10.1118/1.3125662
    • B. G. Fallone, B. Murray, S. Rathee, T. Stanescu, S. Steciw, S. Vidakovic, E. Blosser, and D. Tymofichuk, "First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system," Med. Phys. 36, 2084-2088 (2009). 10.1118/1.3125662
    • (2009) Med. Phys. , vol.36 , pp. 2084-2088
    • Fallone, B.G.1    Murray, B.2    Rathee, S.3    Stanescu, T.4    Steciw, S.5    Vidakovic, S.6    Blosser, E.7    Tymofichuk, D.8
  • 6
    • 0037149519 scopus 로고    scopus 로고
    • Electronic portal imaging devices: A review and historical perspective of contemporary technologies and research
    • 10.1088/0031-9155/47/6/201
    • L. E. Antonuk, "Electronic portal imaging devices: A review and historical perspective of contemporary technologies and research," Phys. Med. Biol. 47, R31-R65 (2002). 10.1088/0031-9155/47/6/201
    • (2002) Phys. Med. Biol. , vol.47
    • Antonuk, L.E.1
  • 8
    • 33746611930 scopus 로고    scopus 로고
    • Study of a prototype high quantum efficiency thick scintillation crystal video-electronic portal imaging device
    • 10.1118/1.2216877
    • S. S. Samant and A. Gopal, "Study of a prototype high quantum efficiency thick scintillation crystal video-electronic portal imaging device," Med. Phys. 33, 2783-2791 (2006). 10.1118/1.2216877
    • (2006) Med. Phys. , vol.33 , pp. 2783-2791
    • Samant, S.S.1    Gopal, A.2
  • 9
    • 0029962979 scopus 로고    scopus 로고
    • Evaluation of a high-density scintillating glass for portal imaging
    • 10.1118/1.597802
    • J.-P. Bissonnette and P. Munro, "Evaluation of a high-density scintillating glass for portal imaging," Med. Phys. 23, 401-406 (1996). 10.1118/1.597802
    • (1996) Med. Phys. , vol.23 , pp. 401-406
    • Bissonnette, J.-P.1    Munro, P.2
  • 11
    • 18644375516 scopus 로고    scopus 로고
    • Development of a new multielement detector system for megavoltage photons
    • 10.1117/12.465632
    • R. Hinderer et al., "Development of a new multielement detector system for megavoltage photons," Proc. SPIE 4682, 809-818 (2002). 10.1117/12.465632
    • (2002) Proc. SPIE , vol.4682 , pp. 809-818
    • Hinderer, R.1
  • 12
    • 27244438336 scopus 로고    scopus 로고
    • Segmented crystalline scintillators: An initial investigation of high quantum efficiency detectors for megavoltage x-ray imaging
    • 10.1118/1.2008407
    • A. Sawant et al., "Segmented crystalline scintillators: An initial investigation of high quantum efficiency detectors for megavoltage x-ray imaging," Med. Phys. 32, 3067-3083 (2005). 10.1118/1.2008407
    • (2005) Med. Phys. , vol.32 , pp. 3067-3083
    • Sawant, A.1
  • 13
    • 33845314003 scopus 로고    scopus 로고
    • 4-photodiode detector for cone beam megavoltage CT: A Monte Carlo study of system design parameters
    • 10.1118/1.2370503
    • 4-photodiode detector for cone beam megavoltage CT: A Monte Carlo study of system design parameters," Med. Phys. 33, 4567-4577 (2006). 10.1118/1.2370503
    • (2006) Med. Phys. , vol.33 , pp. 4567-4577
    • Monajemi, T.T.1    Fallone, B.G.2    Rathee, S.3
  • 14
    • 72049083202 scopus 로고    scopus 로고
    • High-DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: Performance evaluation at extremely low dose
    • 10.1118/1.3259721
    • Y. Wang, L. E. Antonuk, Q. Zhao, Y. El-Mohri, and L. Perna, "High-DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: Performance evaluation at extremely low dose," Med. Phys. 36, 5707-5718 (2009). 10.1118/1.3259721
    • (2009) Med. Phys. , vol.36 , pp. 5707-5718
    • Wang, Y.1    Antonuk, L.E.2    Zhao, Q.3    El-Mohri, Y.4    Perna, L.5
  • 15
    • 9244253183 scopus 로고    scopus 로고
    • Development of high quantum efficiency, flat panel, thick detectors for megavoltage x-ray imaging: A novel direct-conversion design and its feasibility
    • 10.1118/1.1803771
    • G. Pang and J. A. Rowlands, "Development of high quantum efficiency, flat panel, thick detectors for megavoltage x-ray imaging: A novel direct-conversion design and its feasibility," Med. Phys. 31, 3004-3016 (2004). 10.1118/1.1803771
    • (2004) Med. Phys. , vol.31 , pp. 3004-3016
    • Pang, G.1    Rowlands, J.A.2
  • 16
    • 84857883690 scopus 로고    scopus 로고
    • Monte Carlo simulation of a novel water-equivalent electronic portal imaging device using plastic scintillating fibers
    • 10.1118/1.3687163
    • A. Teymurazyan and G. Pang, "Monte Carlo simulation of a novel water-equivalent electronic portal imaging device using plastic scintillating fibers," Med. Phys. 39, 1518-1529 (2012). 10.1118/1.3687163
    • (2012) Med. Phys. , vol.39 , pp. 1518-1529
    • Teymurazyan, A.1    Pang, G.2
  • 18
    • 0030168994 scopus 로고    scopus 로고
    • Radiation-induced light in optical fibers and plastic scintillators: Application to brachytherapy dosimetry
    • 10.1109/23.502302
    • M. R. Arnfield, H. E. Gaballa, R. D. Zwicker, Q. Islam, and R. Schmidt-Ullrich, "Radiation-induced light in optical fibers and plastic scintillators: Application to brachytherapy dosimetry," IEEE Trans. Nucl. Sci. 43, 2077-2084 (1996). 10.1109/23.502302
    • (1996) IEEE Trans. Nucl. Sci. , vol.43 , pp. 2077-2084
    • Arnfield, M.R.1    Gaballa, H.E.2    Zwicker, R.D.3    Islam, Q.4    Schmidt-Ullrich, R.5
  • 19
    • 0034109047 scopus 로고    scopus 로고
    • Dealing with Cerenkov radiation generated in organic scintillator dosimeters by bremsstrahlung beams
    • 10.1088/0031-9155/45/5/307
    • M. A. Clift, R. A. Sutton, and D. V. Webb, "Dealing with Cerenkov radiation generated in organic scintillator dosimeters by bremsstrahlung beams," Phys. Med. Biol. 45, 1165-1182 (2000). 10.1088/0031-9155/45/5/307
    • (2000) Phys. Med. Biol. , vol.45 , pp. 1165-1182
    • Clift, M.A.1    Sutton, R.A.2    Webb, D.V.3
  • 20
    • 0037149989 scopus 로고    scopus 로고
    • A temporal method of avoiding the Cerenkov radiation generated in organic scintillator dosimeters by pulsed mega-voltage electron and photon beams
    • 10.1088/0031-9155/47/8/313
    • M. A. Clift, P. N. Johnston, and D. V. Webb, "A temporal method of avoiding the Cerenkov radiation generated in organic scintillator dosimeters by pulsed mega-voltage electron and photon beams," Phys. Med. Biol. 47, 1421-1433 (2002). 10.1088/0031-9155/47/8/313
    • (2002) Phys. Med. Biol. , vol.47 , pp. 1421-1433
    • Clift, M.A.1    Johnston, P.N.2    Webb, D.V.3
  • 21
    • 33750563412 scopus 로고    scopus 로고
    • Electronic portal imaging based on Cerenkov radiation: A new approach and its feasibility
    • 10.1118/1.2362875
    • X. Mei, J. A. Rowlands, and G. Pang, "Electronic portal imaging based on Cerenkov radiation: A new approach and its feasibility," Med. Phys. 33, 4258-4270 (2006). 10.1118/1.2362875
    • (2006) Med. Phys. , vol.33 , pp. 4258-4270
    • Mei, X.1    Rowlands, J.A.2    Pang, G.3
  • 22
    • 84872028279 scopus 로고    scopus 로고
    • Projection imaging of photon beams by the Čerenkov effect
    • (14p). 10.1118/1.4770286
    • A. K. Glaser, S. C. Davis, D. M. McClatchy, R. Zhang, B. W. Pogue and D. J. Gladstone, "Projection imaging of photon beams by the Čerenkov effect," Med. Phys. 40, 012101 (14pp.) (2013). 10.1118/1.4770286
    • (2013) Med. Phys. , vol.40 , pp. 012101
    • Glaser, A.K.1    Davis, S.C.2    McClatchy, D.M.3    Zhang, R.4    Pogue, B.W.5    Gladstone, D.J.6
  • 23
    • 84872719471 scopus 로고    scopus 로고
    • Projection imaging of photon beams using Čerenkov-excited fluorescence
    • 10.1088/0031-9155/58/3/601
    • A. K. Glaser, S. C. Davis, W. H. A. Voigt, R. Zhang, B. W. Pogue, and D. J. Gladstone, "Projection imaging of photon beams using Čerenkov-excited fluorescence," Phys. Med. Biol. 58, 601-619 (2013). 10.1088/0031-9155/58/3/601
    • (2013) Phys. Med. Biol. , vol.58 , pp. 601-619
    • Glaser, A.K.1    Davis, S.C.2    Voigt, W.H.A.3    Zhang, R.4    Pogue, B.W.5    Gladstone, D.J.6
  • 24
    • 84885807968 scopus 로고    scopus 로고
    • Superficial dosimetry imaging based on Čerenkov emission for external beam radiotherapy with megavoltage x-ray beam
    • (12p). 10.1118/1.4821543
    • R. Zhang, A. K. Glaser, D. J. Gladstone, C. J. Fox and B. W. Pogue, "Superficial dosimetry imaging based on Čerenkov emission for external beam radiotherapy with megavoltage x-ray beam," Med. Phys. 40, 101914 (12pp.) (2013). 10.1118/1.4821543
    • (2013) Med. Phys. , vol.40 , pp. 101914
    • Zhang, R.1    Glaser, A.K.2    Gladstone, D.J.3    Fox, C.J.4    Pogue, B.W.5
  • 25
    • 84880935623 scopus 로고    scopus 로고
    • An inherent anti-scatter detector for megavoltage x-ray imaging
    • 10.1088/0031-9155/58/5/1479
    • A. Teymurazyan and G. Pang, "An inherent anti-scatter detector for megavoltage x-ray imaging," Phys. Med. Biol. 58, 1479-1493 (2013). 10.1088/0031-9155/58/5/1479
    • (2013) Phys. Med. Biol. , vol.58 , pp. 1479-1493
    • Teymurazyan, A.1    Pang, G.2
  • 26
    • 84855593204 scopus 로고    scopus 로고
    • Megavoltage x-ray imaging based on Cerenkov effect: A new application of optical fibres to radiation therapy
    • (13p). 10.1155/2012/724024
    • A. Teymurazyan and G. Pang, "Megavoltage x-ray imaging based on Cerenkov effect: A new application of optical fibres to radiation therapy," Int. J. Opt. 2012, 724024 (13pp.) (2012). 10.1155/2012/724024
    • (2012) Int. J. Opt. , vol.2012 , pp. 724024
    • Teymurazyan, A.1    Pang, G.2
  • 27
    • 0038377458 scopus 로고    scopus 로고
    • Geant4 - A simulation toolkit
    • A, 10.1016/S0168-9002(03)01368-8
    • S. Agostinelli et al., "Geant4-a simulation toolkit," Nucl. Instrum. Methods Phys. Res., Sect. A 506, 250-303 (2003). 10.1016/S0168-9002(03) 01368-8
    • (2003) Nucl. Instrum. Methods Phys. Res., Sect. , vol.506 , pp. 250-303
    • Agostinelli, S.1
  • 28
    • 0035478397 scopus 로고    scopus 로고
    • Study of UV-written channels in lead silicate glasses
    • 10.1016/S0022-3093(01)00796-7
    • C. Contardi, E. R. Taylor, and A. Fu, "Study of UV-written channels in lead silicate glasses," J. Non-Cryst. Solids 291, 113-120 (2001). 10.1016/S0022-3093(01)00796-7
    • (2001) J. Non-Cryst. Solids , vol.291 , pp. 113-120
    • Contardi, C.1    Taylor, E.R.2    Fu, A.3
  • 29
    • 0031016807 scopus 로고    scopus 로고
    • Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation
    • 10.1118/1.597918
    • L. E. Antonuk, Y. El-Mohri, J. H. Siewerdsen, J. Yorkston, W. Huang, V. E. Scarpine, and R. A. Street, "Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation," Med. Phys. 24, 51-70 (1997). 10.1118/1.597918
    • (1997) Med. Phys. , vol.24 , pp. 51-70
    • Antonuk, L.E.1    El-Mohri, Y.2    Siewerdsen, J.H.3    Yorkston, J.4    Huang, W.5    Scarpine, V.E.6    Street, R.A.7
  • 30
    • 80051550496 scopus 로고    scopus 로고
    • Rayleigh scattering in fused silica samples for gravitational wave detectors
    • 10.1016/j.optcom.2011.06.014
    • X. Chen, L. Ju, R. Flaminio, H. Lück, C. Zhao, and D. G. Blair, "Rayleigh scattering in fused silica samples for gravitational wave detectors," Opt. Commun. 284, 4732-4737 (2011). 10.1016/j.optcom.2011.06. 014
    • (2011) Opt. Commun. , vol.284 , pp. 4732-4737
    • Chen, X.1    Ju, L.2    Flaminio, R.3    Lück, H.4    Zhao, C.5    Blair, D.G.6
  • 31
    • 0021482317 scopus 로고
    • The Rayleigh scattering loss in silicate glasses containing PbO
    • 10.1016/0022-3093(84)90372-7
    • G. A. C. M. Spierings, and T. P. M. Meeuwsen, "The Rayleigh scattering loss in silicate glasses containing PbO," J. Non-Cryst. Solids 66, 489-499 (1984). 10.1016/0022-3093(84)90372-7
    • (1984) J. Non-Cryst. Solids , vol.66 , pp. 489-499
    • Spierings, G.A.C.M.1    Meeuwsen, T.P.M.2
  • 32
    • 0031120968 scopus 로고    scopus 로고
    • ROOT - An object oriented data analysis framework
    • 10.1016/S0168-9002(97)00048-X
    • R. Brun and F. Rademakers, "ROOT-An object oriented data analysis framework," Nucl. Instrum. Methods Phys. Res., Sect. A 389, 81-86 (1997). 10.1016/S0168-9002(97)00048-X
    • (1997) Nucl. Instrum. Methods Phys. Res., Sect. A , vol.389 , pp. 81-86
    • Brun, R.1    Rademakers, F.2
  • 33
    • 0031019011 scopus 로고    scopus 로고
    • Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology
    • 10.1118/1.597919
    • J. H. Siewerdsen, L. E. Antonuk, Y. El-Mohri, J. Yorkston, W. Huang, J. M. Boudry, and I. A. Cunningham, "Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology," Med. Phys. 24, 71-89 (1997). 10.1118/1.597919
    • (1997) Med. Phys. , vol.24 , pp. 71-89
    • Siewerdsen, J.H.1    Antonuk, L.E.2    El-Mohri, Y.3    Yorkston, J.4    Huang, W.5    Boudry, J.M.6    Cunningham, I.A.7
  • 34
    • 0015667930 scopus 로고
    • Absorption and noise in x-ray phosphors
    • 10.1063/1.1662918
    • R. K. Swank, "Absorption and noise in x-ray phosphors," J. Appl. Phys. 44, 4199-4203 (1973). 10.1063/1.1662918
    • (1973) J. Appl. Phys. , vol.44 , pp. 4199-4203
    • Swank, R.K.1
  • 35
    • 28044463379 scopus 로고    scopus 로고
    • Development of high quantum efficiency, flat panel, thick detectors for megavoltage x-ray imaging: An experimental study of a single-pixel prototype
    • 10.1118/1.2065487
    • X. Mei and G. Pang, "Development of high quantum efficiency, flat panel, thick detectors for megavoltage x-ray imaging: An experimental study of a single-pixel prototype," Med. Phys. 32, 3379-3388 (2005). 10.1118/1.2065487
    • (2005) Med. Phys. , vol.32 , pp. 3379-3388
    • Mei, X.1    Pang, G.2
  • 36
    • 0021264167 scopus 로고
    • Fluence to dose equivalent conversion factors calculated with EGS3 for electrons from 100 keV to 20 GeV and photons from 11 keV to 20 GeV
    • 10.1097/00004032-198404000-00015
    • D. W. O. Rogers, "Fluence to dose equivalent conversion factors calculated with EGS3 for electrons from 100 keV to 20 GeV and photons from 11 keV to 20 GeV," Health Phys. 46, 891-914 (1984). 10.1097/00004032- 198404000-00015
    • (1984) Health Phys. , vol.46 , pp. 891-914
    • Rogers, D.W.O.1
  • 37
    • 0026076098 scopus 로고
    • The design of megavoltage projection imaging systems: Some theoretical aspects
    • 10.1118/1.596735
    • W. Swindell, E. J. Morton, P. M. Evans, and D. G. Lewis, "The design of megavoltage projection imaging systems: Some theoretical aspects," Med. Phys. 18, 855-866 (1991). 10.1118/1.596735
    • (1991) Med. Phys. , vol.18 , pp. 855-866
    • Swindell, W.1    Morton, E.J.2    Evans, P.M.3    Lewis, D.G.4
  • 38
    • 0028921566 scopus 로고
    • Effects of undersampling on the proper interpretation of modulation transfer function, noise power spectra, and noise equivalent quanta of digital imaging systems
    • 10.1118/1.597600
    • J. T. Dobbins III, "Effects of undersampling on the proper interpretation of modulation transfer function, noise power spectra, and noise equivalent quanta of digital imaging systems," Med. Phys. 22, 171-181 (1995). 10.1118/1.597600
    • (1995) Med. Phys. , vol.22 , pp. 171-181
    • Dobbins III, J.T.1
  • 39
    • 0036799364 scopus 로고    scopus 로고
    • Development of high quantum efficiency flat panel detectors for portal imaging: Intrinsic spatial resolution
    • 10.1118/1.1507779
    • G. Pang and J. A. Rowlands, "Development of high quantum efficiency flat panel detectors for portal imaging: Intrinsic spatial resolution," Med. Phys. 29, 2274-2285 (2002). 10.1118/1.1507779
    • (2002) Med. Phys. , vol.29 , pp. 2274-2285
    • Pang, G.1    Rowlands, J.A.2
  • 40
    • 2442706565 scopus 로고    scopus 로고
    • Performance of electronic portal imaging devices (EPIDs) used in radiotherapy: Image quality and dose measurements
    • 10.1118/1.1688212
    • F. Cremers, T. Frenzel, C. Kausch, D. Albers, T. Schönborn, and R. Schmidt, "Performance of electronic portal imaging devices (EPIDs) used in radiotherapy: Image quality and dose measurements," Med. Phys. 31, 985-996 (2004). 10.1118/1.1688212
    • (2004) Med. Phys. , vol.31 , pp. 985-996
    • Cremers, F.1    Frenzel, T.2    Kausch, C.3    Albers, D.4    Schönborn, T.5    Schmidt, R.6
  • 41
    • 19944432829 scopus 로고    scopus 로고
    • Low-dose megavoltage cone-beam CT for radiation therapy
    • 10.1016/j.ijrob2004.10.011
    • J. Pouliot et al., "Low-dose megavoltage cone-beam CT for radiation therapy," Int. J. Radiat. Oncol., Biol., Phys. 61, 552-560 (2005). 10.1016/j.ijrobp.2004.10.011
    • (2005) Int. J. Radiat. Oncol., Biol., Phys. , vol.61 , pp. 552-560
    • Pouliot, J.1
  • 42
    • 0026837927 scopus 로고
    • A simple method for determining the modulation transfer function in digital radiography
    • 10.1109/42.126908
    • H. Fujita, D. Y. Tsai, T. Itoh, K. Doi, J. Morishita, K. Ueda, and A. Ohtsuka, "A simple method for determining the modulation transfer function in digital radiography," IEEE Trans. Med. Imaging 11, 34-39 (1992). 10.1109/42.126908
    • (1992) IEEE Trans. Med. Imaging , vol.11 , pp. 34-39
    • Fujita, H.1    Tsai, D.Y.2    Itoh, T.3    Doi, K.4    Morishita, J.5    Ueda, K.6    Ohtsuka, A.7
  • 43
    • 0000658326 scopus 로고    scopus 로고
    • Image quality metrics for digital systems
    • edited by J. Beutel, H. L. Kundel, and R. L. Van Metter (SPIE, Bellingham, WA)
    • J. Dobbins, "Image quality metrics for digital systems," in Handbook of Medical Imaging, edited by J. Beutel, H. L. Kundel, and R. L. Van Metter (SPIE, Bellingham, WA, 2000), Vol. 1, pp. 161-222.
    • (2000) Handbook of Medical Imaging , vol.1 , pp. 161-222
    • Dobbins, J.1
  • 44
    • 0032767557 scopus 로고    scopus 로고
    • Noise power spectra of images from digital mammography detectors
    • 10.1118/1.598623
    • M. B. Williams, P. A. Mangiafico, and P. U. Simoni, "Noise power spectra of images from digital mammography detectors," Med. Phys. 26, 1279-1293 (1999). 10.1118/1.598623
    • (1999) Med. Phys. , vol.26 , pp. 1279-1293
    • Williams, M.B.1    Mangiafico, P.A.2    Simoni, P.U.3
  • 45
    • 0002050483 scopus 로고    scopus 로고
    • Applied linear-systems theory
    • edited by J. Beutel, H. L. Kundel, and R. L. Van Metter (SPIE, Bellingham, WA)
    • I. A. Cunningham, "Applied linear-systems theory," in Handbook of Medical Imaging, edited by J. Beutel, H. L. Kundel, and R. L. Van Metter (SPIE, Bellingham, WA, 2000), Vol. 1, pp. 79-159.
    • (2000) Handbook of Medical Imaging , vol.1 , pp. 79-159
    • Cunningham, I.A.1
  • 46
    • 0032706876 scopus 로고    scopus 로고
    • Monte Carlo simulations of the imaging performance of metal plate/phosphor screens used in radiotherapy
    • 10.1118/1.598727
    • C. Kausch, B. Schreiber, F. Kreuder, R. Schmidt, and O. Dössel, "Monte Carlo simulations of the imaging performance of metal plate/phosphor screens used in radiotherapy," Med. Phys. 26, 2113-2124 (1999). 10.1118/1.598727
    • (1999) Med. Phys. , vol.26 , pp. 2113-2124
    • Kausch, C.1    Schreiber, B.2    Kreuder, F.3    Schmidt, R.4    Dössel, O.5
  • 47
    • 2442691615 scopus 로고    scopus 로고
    • Modeling scintillator-photodiodes as detectors for megavoltage CT
    • 10.1118/1.1710733
    • T. T. Monajemi, S. Steciw, B. G. Fallone, and S. Rathee, "Modeling scintillator-photodiodes as detectors for megavoltage CT," Med. Phys. 31, 1225-1234 (2004). 10.1118/1.1710733
    • (2004) Med. Phys. , vol.31 , pp. 1225-1234
    • Monajemi, T.T.1    Steciw, S.2    Fallone, B.G.3    Rathee, S.4
  • 48
    • 0029144630 scopus 로고
    • Monte Carlo studies of x-ray energy absorption and quantum noise in megavoltage transmission radiography
    • 10.1118/1.597593
    • D. A. Jaffray, J. J. Battista, A. Fenster, and P. Munro, "Monte Carlo studies of x-ray energy absorption and quantum noise in megavoltage transmission radiography," Med. Phys. 22, 1077-1088 (1995). 10.1118/1.597593
    • (1995) Med. Phys. , vol.22 , pp. 1077-1088
    • Jaffray, D.A.1    Battista, J.J.2    Fenster, A.3    Munro, P.4
  • 49
    • 0019497908 scopus 로고
    • Image information transfer properties of x-ray fluorescent screens
    • 10.1118/1.594836
    • C. E. Dick and J. W. Motz, "Image information transfer properties of x-ray fluorescent screens," Med. Phys. 8, 337-346 (1981). 10.1118/1.594836
    • (1981) Med. Phys. , vol.8 , pp. 337-346
    • Dick, C.E.1    Motz, J.W.2
  • 50
    • 0028784806 scopus 로고
    • X-ray imaging using amorphous selenium: Feasibility of a flat panel self-scanned detector for digital radiology
    • 10.1118/1.597628
    • W. Zhao and J. A. Rowlands, "X-ray imaging using amorphous selenium: Feasibility of a flat panel self-scanned detector for digital radiology," Med. Phys. 22, 1595-1604 (1995). 10.1118/1.597628
    • (1995) Med. Phys. , vol.22 , pp. 1595-1604
    • Zhao, W.1    Rowlands, J.A.2
  • 51
    • 0000899259 scopus 로고    scopus 로고
    • Flat panel detectors for digital radiography
    • edited by J. Beutel, H. L. Kundel, and R. L. Van Metter (SPIE, Bellingham, WA)
    • J. A. Rowlands and J. Yorkston, "Flat panel detectors for digital radiography," in Handbook of Medical Imaging, edited by J. Beutel, H. L. Kundel, and R. L. Van Metter (SPIE, Bellingham, WA, 2000), Vol. 1, pp. 223-328.
    • (2000) Handbook of Medical Imaging , vol.1 , pp. 223-328
    • Rowlands, J.A.1    Yorkston, J.2
  • 52
    • 0031439126 scopus 로고    scopus 로고
    • Digital radiology using active matrix readout of amorphous selenium: Theoretical analysis of detective quantum efficiency
    • 10.1118/1.598097
    • W. Zhao and J. A. Rowlands, "Digital radiology using active matrix readout of amorphous selenium: Theoretical analysis of detective quantum efficiency," Med. Phys. 24, 1819-1833 (1997). 10.1118/1.598097 Canada
    • (1997) Med. Phys. , vol.24 , pp. 1819-1833
    • Zhao, W.1    Rowlands, J.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.