Indexed keywords
POLY(METHYL METHACRYLATE);
POLYSTYRENE;
SILICON DIOXIDE;
TITANIUM DIOXIDE;
ARTICLE;
DOSIMETER;
ENERGY;
FLUORESCENCE;
LIGHT;
OPTICS;
PHANTOM;
PRIORITY JOURNAL;
RADIATION DOSE;
SCINTILLATION;
THREE DIMENSIONAL IMAGING;
BIOPHYSICS;
EQUIPMENT DESIGN;
HUMANS;
LIGHT;
MODELS, THEORETICAL;
OPTICS;
PHANTOMS, IMAGING;
POLYVINYLS;
RADIOTHERAPY DOSAGE;
RADIOTHERAPY, HIGH-ENERGY;
SCINTILLATION COUNTING;
2
0028293283
60Co and high-energy therapy machines
60Co and high-energy therapy machines Phys. Med. Biol. 39 253-63
(1994)
Phys. Med. Biol.
, vol.39
, pp. 253-263
Beddar, A.S.1
3
0009065660
On the nature of light induced by radiation in transparent media in radiotherapy
Beddar A S, Attix F H and Mackie T R 1989 On the nature of light induced by radiation in transparent media in radiotherapy Med. Phys. 16 683
(1989)
Med. Phys.
, vol.16
, pp. 683
Beddar, A.S.1
Attix, F.H.2
Mackie, T.R.3
4
0026555508
Cerenkov light generated in optical fibres and other light pipes irradiated by electron beams
_ 1992a Cerenkov light generated in optical fibres and other light pipes irradiated by electron beams Phys. Med. Biol. 37 925-35
(1992)
Phys. Med. Biol.
, vol.37
, pp. 925-935
5
0026804696
Water equivalent plastic scintillation detectors for high energy beam dosimetry: I. Properties and measurements
_ 1992b Water equivalent plastic scintillation detectors for high energy beam dosimetry: I. Properties and measurements Phys. Med. Biol. 37 1883-900
(1992)
Phys. Med. Biol.
, vol.37
, pp. 1883-1900
6
0026793771
Water equivalent plastic scintillation detectors for high energy beam dosimetry: II. Properties and measurements
_ 1992c Water equivalent plastic scintillation detectors for high energy beam dosimetry: II. Properties and measurements Phys. Med. Biol. 37 1901-13
(1992)
Phys. Med. Biol.
, vol.37
, pp. 1901-1913
7
0027219790
Optical filtering and spectral measurements of radiation-induced light in plastic scintillation dosimetry
Boer S F, Beddar A S and Rawlinson J A 1993 Optical filtering and spectral measurements of radiation-induced light in plastic scintillation dosimetry Phys. Med. Biol. 38 945-58
(1993)
Phys. Med. Biol.
, vol.38
, pp. 945-958
Boer, S.F.1
Beddar, A.S.2
Rawlinson, J.A.3
8
0343269552
The response of organic scintillators to electron energy deposited in them
Brannen E and Olde G L 1962 The response of organic scintillators to electron energy deposited in them Radiat. Res. 16 1-6
(1962)
Radiat. Res.
, vol.16
, pp. 1-6
Brannen, E.1
Olde, G.L.2
9
0001684317
Response of anthracene and stilbene to low-energy protons and x-rays
Fowler J M and Roos C E 1955 Response of anthracene and stilbene to low-energy protons and x-rays Phys. Rev. 98 996-9
(1955)
Phys. Rev.
, vol.98
, pp. 996-999
Fowler, J.M.1
Roos, C.E.2
10
0003484991
Absorbed dose determination in photon and electron beams
Vienna: IAEA
IAEA 1987 Absorbed dose determination in photon and electron beams IAEA Technical Report Series 277 (Vienna: IAEA)
(1987)
IAEA Technical Report Series 277
12
0002530448
The effects of radiation on absorption and luminescence of libre optic waveguides and materials
Mattern P L, Watkins L M, Skoog C P, Brandon J R and Barsis E H 1974 The effects of radiation on absorption and luminescence of libre optic waveguides and materials IEEE Trans. Nucl. Sci. 21 81-93
(1974)
IEEE Trans. Nucl. Sci.
, vol.21
, pp. 81-93
Mattern, P.L.1
Watkins, L.M.2
Skoog, C.P.3
Brandon, J.R.4
Barsis, E.H.5
13
0021043262
Effects of radiation damage on p type silicon detectors
Rikner G and Grusell E 1983 Effects of radiation damage on p type silicon detectors Phys. Med. Biol. 28 1261-7
(1983)
Phys. Med. Biol.
, vol.28
, pp. 1261-1267
Rikner, G.1
Grusell, E.2
14
0343705163
Response of anthracene scintillation crystals to monoenergetic soft x-rays
Robinson W H and Jentschke W 1954 Response of anthracene scintillation crystals to monoenergetic soft x-rays Phys. Rev. 95 1412-14
(1954)
Phys. Rev.
, vol.95
, pp. 1412-1414
Robinson, W.H.1
Jentschke, W.2
15
0001212398
Measurement of the response of several organic scintillators to electrons, protons and deuterons
Smith D L, Polk R G and Miller T G 1968 Measurement of the response of several organic scintillators to electrons, protons and deuterons Nucl. Instrum. Methods 64 157-66
(1968)
Nucl. Instrum. Methods
, vol.64
, pp. 157-166
Smith, D.L.1
Polk, R.G.2
Miller, T.G.3