Volumn 26, Issue 10, 1999, Pages 2113-2124

Monte carlo simulations of the imaging performance of metal plate/phosphor screens used in radiotherapy

Author keywords

DQE(f); Image quality; Metal plate phosphor screens; Monte Carlo Simulation; MTF(f); NPS(f); Portal images

Indexed keywords

ATOMS; GAMMA RAYS; IMAGE ENHANCEMENT; IMAGE QUALITY; LENSES; LIGHT EMISSION; METALS; PHOSPHORS; PHOTONS; PLATE METAL; RADIOTHERAPY; SIGNAL TO NOISE RATIO; VIDEO CAMERAS; X RAYS;

EID: 0032706876     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598727     Document Type: Article
Times cited : (65)

References (31)
  • 2
    • 0029113890 scopus 로고
    • Digital portal image registration by sequential anatomical matchpoint and image correlations for real-time continuous field alignment verification
    • B. McParland and J. Kumaradas, "Digital portal image registration by sequential anatomical matchpoint and image correlations for real-time continuous field alignment verification," Med. Phys. 22, 1063-1075 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 1063-1075
    • McParland, B.1    Kumaradas, J.2
  • 3
    • 0028260271 scopus 로고
    • A semiautomatic method for registration of portal images
    • J. Mosely and P. Munro, "A semiautomatic method for registration of portal images," Med. Phys. 21, 551-558 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 551-558
    • Mosely, J.1    Munro, P.2
  • 4
    • 0025932046 scopus 로고
    • Fast evaluation of patient set-up during radiotherapy by aligning features in portal and simulator images
    • J. Bijhold, M. van Herk, P. Vijlbrief, and J. Lebesque, "Fast evaluation of patient set-up during radiotherapy by aligning features in portal and simulator images," Phys. Med. Biol. 36, 1665-1679 (1991).
    • (1991) Phys. Med. Biol. , vol.36 , pp. 1665-1679
    • Bijhold, J.1    Van Herk, M.2    Vijlbrief, P.3    Lebesque, J.4
  • 5
    • 0032093825 scopus 로고    scopus 로고
    • A structure based method for on-line matching of portal images for an optimal patient set-up in radiotherapy
    • F. Kreuder, B. Schreiber, C. Kausch, and O. Dössel, "A structure based method for on-line matching of portal images for an optimal patient set-up in radiotherapy," Philips J. Res. 51, 317-337 (1998).
    • (1998) Philips J. Res. , vol.51 , pp. 317-337
    • Kreuder, F.1    Schreiber, B.2    Kausch, C.3    Dössel, O.4
  • 6
    • 0025836884 scopus 로고
    • Investigation of an FFT-based correlation technique for verification of radiation treatment setup
    • S. M. Jones and A. I. Boyer, "Investigation of an FFT-based correlation technique for verification of radiation treatment setup," Med. Phys. 18, 1116-1125 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 1116-1125
    • Jones, S.M.1    Boyer, A.I.2
  • 7
    • 0030067570 scopus 로고    scopus 로고
    • A grey-level image alignment algorithm for registration of portal images and digitally reconstructed radiographs
    • D. H. Hristov and B. G. Fallone, "A grey-level image alignment algorithm for registration of portal images and digitally reconstructed radiographs," Med. Phys. 23, 75-84 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 75-84
    • Hristov, D.H.1    Fallone, B.G.2
  • 8
    • 0029829755 scopus 로고    scopus 로고
    • Physical characteristics of a commercial electronic portal imaging device
    • V. G. M. Althof, J. C. J. de Boer, H. Huizenga, J. C. Stroom, and A. G. Visser, "Physical characteristics of a commercial electronic portal imaging device," Med. Phys. 23, 1845-1855 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 1845-1855
    • Althof, V.G.M.1    De Boer, J.C.J.2    Huizenga, H.3    Stroom, J.C.4    Visser, A.G.5
  • 11
  • 12
    • 0018629893 scopus 로고
    • Influence of metal screens on contrast in megavoltage x ray imaging
    • R. T. Droege and B. E. Bjärngard, "Influence of metal screens on contrast in megavoltage x ray imaging," Med. Phys. 6, 487-493 (1979).
    • (1979) Med. Phys. , vol.6 , pp. 487-493
    • Droege, R.T.1    Bjärngard, B.E.2
  • 13
    • 0018582561 scopus 로고
    • Metal screen-film detector MTF at megavoltage x ray energies
    • R. T. Droege and B. E. Bjärngard, "Metal screen-film detector MTF at megavoltage x ray energies," Med. Phys. 6, 515-518 (1979).
    • (1979) Med. Phys. , vol.6 , pp. 515-518
    • Droege, R.T.1    Bjärngard, B.E.2
  • 14
    • 0025813557 scopus 로고
    • A linear array, scintillation crystal-photodiode detector for megavoltage imaging
    • E. J. Morton, W. Swindell, D. G. Lewis, and P. M. Evans. "A linear array, scintillation crystal-photodiode detector for megavoltage imaging," Med. Phys. 18, 681-691 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 681-691
    • Morton, E.J.1    Swindell, W.2    Lewis, D.G.3    Evans, P.M.4
  • 16
    • 0025107872 scopus 로고
    • Therapy imaging: A signal-to-noise analysis of a fluoroscsopic imaging system for radiotherapy localization
    • P. Munro, J. A. Rawlinson, and A. Fenster, "Therapy imaging: A signal-to-noise analysis of a fluoroscsopic imaging system for radiotherapy localization," Med. Phys. 17, 763-772 (1990).
    • (1990) Med. Phys. , vol.17 , pp. 763-772
    • Munro, P.1    Rawlinson, J.A.2    Fenster, A.3
  • 17
    • 0023567351 scopus 로고
    • Therapy imaging: A signal-to-noise analysis of metal plate/film detectors
    • P. Munro, J. A. Rawlinson, and A. Fenster, "Therapy imaging: A signal-to-noise analysis of metal plate/film detectors," Med. Phys. 14, 975-985 (1987).
    • (1987) Med. Phys. , vol.14 , pp. 975-985
    • Munro, P.1    Rawlinson, J.A.2    Fenster, A.3
  • 19
    • 0028025610 scopus 로고
    • Thick phosphor screens for on-line imaging
    • B. Wowk and S. Shalev, "Thick phosphor screens for on-line imaging," Med. Phys. 21, 1269-1276 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 1269-1276
    • Wowk, B.1    Shalev, S.2
  • 20
    • 0027323822 scopus 로고
    • Monte Carlo optimization of metal/phosphor screens at megavoltage energies
    • T. Radcliffe, G. Barnea, B. Wowk, G. Rajapakshe, and S. Shalev, "Monte Carlo optimization of metal/phosphor screens at megavoltage energies," Med. Phys. 20, 1161-1169 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 1161-1169
    • Radcliffe, T.1    Barnea, G.2    Wowk, B.3    Rajapakshe, G.4    Shalev, S.5
  • 21
    • 0029144630 scopus 로고
    • Monte Carlo studies of x ray energy absorption and quantum noise in megavoltage transmission radiography
    • D. A. Jaffray, J. J. Battista, A. Fenster, and P. Munro, "Monte Carlo studies of x ray energy absorption and quantum noise in megavoltage transmission radiography," Med. Phys. 22, 1077-1088 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 1077-1088
    • Jaffray, D.A.1    Battista, J.J.2    Fenster, A.3    Munro, P.4
  • 22
    • 0030986681 scopus 로고    scopus 로고
    • Optimal phosphor thickness for portal imaging
    • J.-P. Bissonnette, I. A. Cunningham, and P. Munro, "Optimal phosphor thickness for portal imaging," Med. Phys. 24, 803-814 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 803-814
    • Bissonnette, J.-P.1    Cunningham, I.A.2    Munro, P.3
  • 23
    • 0031004518 scopus 로고    scopus 로고
    • A quantum accounting and detective quantum efficiency analysis for video-based portal imaging
    • J.-P. Bissonnette. I. A. Cunningham, D. A. Jaffray, A. Fenster, and P. Munro, "A quantum accounting and detective quantum efficiency analysis for video-based portal imaging," Med. Phys. 24, 815-826 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 815-826
    • Bissonnette, J.-P.1    Cunningham, I.A.2    Jaffray, D.A.3    Fenster, A.4    Munro, P.5
  • 26
    • 0000979064 scopus 로고
    • The equivalent quantum efficiency of the photographic process
    • R. Shaw, "The equivalent quantum efficiency of the photographic process," J. Photogr. Sci. 11, 199-204 (1963).
    • (1963) J. Photogr. Sci. , vol.11 , pp. 199-204
    • Shaw, R.1
  • 28
    • 0015667930 scopus 로고
    • Absorption and noise in x ray phosphors
    • R. K. Swank, "Absorption and noise in x ray phosphors," J. Appl. Phys. 44, 4199-4203 (1973).
    • (1973) J. Appl. Phys. , vol.44 , pp. 4199-4203
    • Swank, R.K.1
  • 29
    • 0016091323 scopus 로고
    • Measurement of absorption and noise in an x ray image intensifier
    • R. K. Swank, "Measurement of absorption and noise in an x ray image intensifier," J. Appl. Phys. 45, 3673-3678 (1974).
    • (1974) J. Appl. Phys. , vol.45 , pp. 3673-3678
    • Swank, R.K.1
  • 31
    • 0021849353 scopus 로고
    • Energy and angular distributions of photons from medical linear accelerators
    • R. Mohan, C. Chui, and L. Lidofsky, "Energy and angular distributions of photons from medical linear accelerators," Med. Phys. 12, 592 (1985).
    • (1985) Med. Phys. , vol.12 , pp. 592
    • Mohan, R.1    Chui, C.2    Lidofsky, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.