메뉴 건너뛰기




Volumn 133, Issue 3, 2014, Pages 455-463

Real-time measurement of free thrombin: Evaluation of the usability of a new thrombin assay for coagulation monitoring during extracorporeal circulation

Author keywords

aptamer; coagulation; extracorporeal circulation; heparin; Thrombin

Indexed keywords

HEPARIN; THROMBIN;

EID: 84893912324     PISSN: 00493848     EISSN: 18792472     Source Type: Journal    
DOI: 10.1016/j.thromres.2013.12.007     Document Type: Article
Times cited : (11)

References (34)
  • 1
    • 20444392807 scopus 로고    scopus 로고
    • Lillehei, Lewis, and Wangensteen: The right mix for giant achievements in cardiac surgery
    • V.L. Gott Lillehei, Lewis, and Wangensteen: the right mix for giant achievements in cardiac surgery Ann Thorac Surg 79 2005 S2210 S2213
    • (2005) Ann Thorac Surg , vol.79
    • Gott, V.L.1
  • 2
    • 0032460111 scopus 로고    scopus 로고
    • The platelet in cardiopulmonary bypass
    • A. Weerasinghe, and K.M. Taylor The platelet in cardiopulmonary bypass Ann Thorac Surg 66 1998 2145 2152
    • (1998) Ann Thorac Surg , vol.66 , pp. 2145-2152
    • Weerasinghe, A.1    Taylor, K.M.2
  • 3
    • 0026689814 scopus 로고
    • Hematologic changes during and after cardiopulmonary bypass and their relationship to the bleeding time and nonsurgical blood loss
    • S.F. Khuri, J.A. Wolfe, M. Josa, T.C. Axford, I. Szymanski, and S. Assousa et al. Hematologic changes during and after cardiopulmonary bypass and their relationship to the bleeding time and nonsurgical blood loss J Thorac Cardiovasc Surg 104 1992 94 107
    • (1992) J Thorac Cardiovasc Surg , vol.104 , pp. 94-107
    • Khuri, S.F.1    Wolfe, J.A.2    Josa, M.3    Axford, T.C.4    Szymanski, I.5    Assousa, S.6
  • 4
    • 7944231168 scopus 로고    scopus 로고
    • Coagulation disorders of cardiopulmonary bypass: A review
    • D. Paparella, S.J. Brister, and M.R. Buchanan Coagulation disorders of cardiopulmonary bypass: a review Intensive Care Med 30 2004 1873 1881
    • (2004) Intensive Care Med , vol.30 , pp. 1873-1881
    • Paparella, D.1    Brister, S.J.2    Buchanan, M.R.3
  • 6
    • 0023598650 scopus 로고
    • Thrombin-induced changes in platelet membrane glycoproteins Ib, IX, and IIb-IIIa complex
    • A.D. Michelson, and M.R. Barnard Thrombin-induced changes in platelet membrane glycoproteins Ib, IX, and IIb-IIIa complex Blood 70 1987 1673 1678
    • (1987) Blood , vol.70 , pp. 1673-1678
    • Michelson, A.D.1    Barnard, M.R.2
  • 7
    • 0029981294 scopus 로고    scopus 로고
    • Thrombin-induced increase in endothelial permeability is associated with changes in cell-to-cell junction organization
    • M.J. Rabiet, J.L. Plantier, Y. Rival, Y. Genoux, M.G. Lampugnani, and E. Dejana Thrombin-induced increase in endothelial permeability is associated with changes in cell-to-cell junction organization Arterioscler Thromb Vasc Biol 16 1996 488 496
    • (1996) Arterioscler Thromb Vasc Biol , vol.16 , pp. 488-496
    • Rabiet, M.J.1    Plantier, J.L.2    Rival, Y.3    Genoux, Y.4    Lampugnani, M.G.5    Dejana, E.6
  • 8
    • 28344436780 scopus 로고    scopus 로고
    • Protease-activated receptors in hemostasis, thrombosis and vascular biology
    • S.R. Coughlin Protease-activated receptors in hemostasis, thrombosis and vascular biology J Thromb Haemost 3 2005 1800 1814
    • (2005) J Thromb Haemost , vol.3 , pp. 1800-1814
    • Coughlin, S.R.1
  • 9
    • 0032834021 scopus 로고    scopus 로고
    • Anticoagulation monitoring during cardiac surgery: A review of current and emerging techniques
    • G.J. Despotis, G. Gravlee, K. Filos, and J. Levy Anticoagulation monitoring during cardiac surgery: a review of current and emerging techniques Anesthesiology 91 1999 1122 1151
    • (1999) Anesthesiology , vol.91 , pp. 1122-1151
    • Despotis, G.J.1    Gravlee, G.2    Filos, K.3    Levy, J.4
  • 10
    • 44249090265 scopus 로고    scopus 로고
    • The story of the discovery of heparin and warfarin
    • D. Wardrop, and D. Keeling The story of the discovery of heparin and warfarin Br J Haematol 141 2008 757 763
    • (2008) Br J Haematol , vol.141 , pp. 757-763
    • Wardrop, D.1    Keeling, D.2
  • 11
    • 81255128023 scopus 로고    scopus 로고
    • Bivalirudin-based versus conventional heparin anticoagulation for postcardiotomy extracorporeal membrane oxygenation
    • M. Ranucci, A. Ballotta, H. Kandil, G. Isgro, C. Carlucci, and E. Baryshnikova et al. Bivalirudin-based versus conventional heparin anticoagulation for postcardiotomy extracorporeal membrane oxygenation Crit Care 15 2011 R275
    • (2011) Crit Care , vol.15 , pp. 275
    • Ranucci, M.1    Ballotta, A.2    Kandil, H.3    Isgro, G.4    Carlucci, C.5    Baryshnikova, E.6
  • 12
    • 77957695786 scopus 로고    scopus 로고
    • Activated clotting times, heparin responses, and antithrombin: Have we been wrong all these years?
    • J.H. Levy, and R.M. Sniecinski Activated clotting times, heparin responses, and antithrombin: have we been wrong all these years? Anesth Analg 111 2010 833 835
    • (2010) Anesth Analg , vol.111 , pp. 833-835
    • Levy, J.H.1    Sniecinski, R.M.2
  • 13
    • 0033016874 scopus 로고    scopus 로고
    • Heparin management test versus activated coagulation time during cardiovascular surgery: Correlation with anti-Xa activity
    • J.C. Fitch, K.L. Geary, G.P. Mirto, D.W. Byrne, and R.L. Hines Heparin management test versus activated coagulation time during cardiovascular surgery: correlation with anti-Xa activity J Cardiothorac Vasc Anesth 13 1999 53 57
    • (1999) J Cardiothorac Vasc Anesth , vol.13 , pp. 53-57
    • Fitch, J.C.1    Geary, K.L.2    Mirto, G.P.3    Byrne, D.W.4    Hines, R.L.5
  • 16
    • 84862005637 scopus 로고    scopus 로고
    • Combined Blockade of ADP Receptors and PI3-Kinase p110beta Fully Prevents Platelet and Leukocyte Activation during Hypothermic Extracorporeal Circulation
    • S. Krajewski, J. Kurz, T. Geisler, K. Peter, H.P. Wendel, and A. Straub Combined Blockade of ADP Receptors and PI3-Kinase p110beta Fully Prevents Platelet and Leukocyte Activation during Hypothermic Extracorporeal Circulation PLoS One 7 2012 e38455
    • (2012) PLoS One , vol.7 , pp. 38455
    • Krajewski, S.1    Kurz, J.2    Geisler, T.3    Peter, K.4    Wendel, H.P.5    Straub, A.6
  • 17
    • 84878287428 scopus 로고    scopus 로고
    • Hemocompatibility evaluation of different silver nanoparticle concentrations employing a modified Chandler-loop in vitro assay on human blood
    • S. Krajewski, R. Prucek, A. Panacek, M. Avci-Adali, A. Nolte, and A. Straub et al. Hemocompatibility evaluation of different silver nanoparticle concentrations employing a modified Chandler-loop in vitro assay on human blood Acta Biomater 9 2013 7460 7468
    • (2013) Acta Biomater , vol.9 , pp. 7460-7468
    • Krajewski, S.1    Prucek, R.2    Panacek, A.3    Avci-Adali, M.4    Nolte, A.5    Straub, A.6
  • 18
    • 80051593887 scopus 로고    scopus 로고
    • A novel in vitro model for preclinical testing of the hemocompatibility of intravascular stents according to ISO 10993-4
    • S. Sinn, T. Scheuermann, S. Deichelbohrer, G. Ziemer, and H.P. Wendel A novel in vitro model for preclinical testing of the hemocompatibility of intravascular stents according to ISO 10993-4 J Mater Sci Mater Med 22 2011 1521 1528
    • (2011) J Mater Sci Mater Med , vol.22 , pp. 1521-1528
    • Sinn, S.1    Scheuermann, T.2    Deichelbohrer, S.3    Ziemer, G.4    Wendel, H.P.5
  • 19
    • 82255179277 scopus 로고    scopus 로고
    • Activation of the hemostatic system during cardiopulmonary bypass
    • R.M. Sniecinski, and W.L. Chandler Activation of the hemostatic system during cardiopulmonary bypass Anesth Analg 113 2011 1319 1333
    • (2011) Anesth Analg , vol.113 , pp. 1319-1333
    • Sniecinski, R.M.1    Chandler, W.L.2
  • 20
    • 64649095956 scopus 로고    scopus 로고
    • Heparin-induced thrombocytopenia in patients with ventricular assist devices: Are new prevention strategies required?
    • T.E. Warkentin, A. Greinacher, and A. Koster Heparin-induced thrombocytopenia in patients with ventricular assist devices: are new prevention strategies required? Ann Thorac Surg 87 2009 1633 1640
    • (2009) Ann Thorac Surg , vol.87 , pp. 1633-1640
    • Warkentin, T.E.1    Greinacher, A.2    Koster, A.3
  • 21
    • 1642375396 scopus 로고    scopus 로고
    • Determinants of antithrombin consumption in cardiac operations requiring cardiopulmonary bypass
    • M. Ranucci, A. Ditta, A. Boncilli, M. Cotza, G. Carboni, and S. Brozzi et al. Determinants of antithrombin consumption in cardiac operations requiring cardiopulmonary bypass Perfusion 19 2004 47 52
    • (2004) Perfusion , vol.19 , pp. 47-52
    • Ranucci, M.1    Ditta, A.2    Boncilli, A.3    Cotza, M.4    Carboni, G.5    Brozzi, S.6
  • 23
    • 0027524694 scopus 로고
    • Heparin binding proteins. Contribution to heparin rebound after cardiopulmonary bypass
    • K.H. Teoh, E. Young, C.A. Bradley, and J. Hirsh Heparin binding proteins. Contribution to heparin rebound after cardiopulmonary bypass Circulation 88 1993 II420 II425
    • (1993) Circulation , vol.88
    • Teoh, K.H.1    Young, E.2    Bradley, C.A.3    Hirsh, J.4
  • 24
    • 0027961049 scopus 로고
    • Comparison of activated coagulation time and whole blood heparin measurements with laboratory plasma anti-Xa heparin concentration in patients having cardiac operations
    • G.J. Despotis, A.L. Summerfield, J.H. Joist, L.T. Goodnough, S.A. Santoro, and E. Spitznagel et al. Comparison of activated coagulation time and whole blood heparin measurements with laboratory plasma anti-Xa heparin concentration in patients having cardiac operations J Thorac Cardiovasc Surg 108 1994 1076 1082
    • (1994) J Thorac Cardiovasc Surg , vol.108 , pp. 1076-1082
    • Despotis, G.J.1    Summerfield, A.L.2    Joist, J.H.3    Goodnough, L.T.4    Santoro, S.A.5    Spitznagel, E.6
  • 25
    • 35248828591 scopus 로고    scopus 로고
    • Heparin monitoring during cardiopulmonary bypass surgery using the one-step point-of-care whole blood anti-factor-Xa clotting assay heptest-POC-Hi
    • P. Hellstern, J. Bach, M. Simon, and W. Saggau Heparin monitoring during cardiopulmonary bypass surgery using the one-step point-of-care whole blood anti-factor-Xa clotting assay heptest-POC-Hi J Extra Corpor Technol 39 2007 81 86
    • (2007) J Extra Corpor Technol , vol.39 , pp. 81-86
    • Hellstern, P.1    Bach, J.2    Simon, M.3    Saggau, W.4
  • 26
    • 84888123518 scopus 로고    scopus 로고
    • A novel method for the direct determination of heparin concentration during cardiopulmonary bypass surgery
    • S. Haselbach, J. Maurer, V. Vogel, S. Harder, C.F. Weber, and D. Baykut et al. A novel method for the direct determination of heparin concentration during cardiopulmonary bypass surgery Clin Chem Lab Med 2013 1 7
    • (2013) Clin Chem Lab Med , pp. 1-7
    • Haselbach, S.1    Maurer, J.2    Vogel, V.3    Harder, S.4    Weber, C.F.5    Baykut, D.6
  • 27
    • 0020085770 scopus 로고
    • Studies of the prothrombin activation pathway utilizing radioimmunoassays for the F2/F1 + 2 fragment and thrombin-antithrombin complex
    • J.M. Teitel, K.A. Bauer, H.K. Lau, and R.D. Rosenberg Studies of the prothrombin activation pathway utilizing radioimmunoassays for the F2/F1 + 2 fragment and thrombin-antithrombin complex Blood 59 1982 1086 1097
    • (1982) Blood , vol.59 , pp. 1086-1097
    • Teitel, J.M.1    Bauer, K.A.2    Lau, H.K.3    Rosenberg, R.D.4
  • 28
    • 0029985611 scopus 로고    scopus 로고
    • Markers of activated coagulation and their usefulness in the clinical laboratory
    • A. Tripodi, and P.M. Mannucci Markers of activated coagulation and their usefulness in the clinical laboratory Clin Chem 42 1996 664 669
    • (1996) Clin Chem , vol.42 , pp. 664-669
    • Tripodi, A.1    Mannucci, P.M.2
  • 32
    • 0037804799 scopus 로고    scopus 로고
    • Estimating the rate of thrombin and fibrin generation in vivo during cardiopulmonary bypass
    • W.L. Chandler, and T. Velan Estimating the rate of thrombin and fibrin generation in vivo during cardiopulmonary bypass Blood 101 2003 4355 4362
    • (2003) Blood , vol.101 , pp. 4355-4362
    • Chandler, W.L.1    Velan, T.2
  • 33
    • 80053196642 scopus 로고    scopus 로고
    • Effects of argatroban as an anticoagulant for intermittent veno-venous hemofiltration (IVVH) in patients at high risk of bleeding
    • [U1517]
    • X.F. Sun, Y.S. Chen, Q. Xiao, Y. Wang, J.H. Zhou, and Z.F. Ma et al. Effects of argatroban as an anticoagulant for intermittent veno-venous hemofiltration (IVVH) in patients at high risk of bleeding Nephrol Dial Transplant 26 2011 2954 [U1517]
    • (2011) Nephrol Dial Transplant , vol.26 , pp. 2954
    • Sun, X.F.1    Chen, Y.S.2    Xiao, Q.3    Wang, Y.4    Zhou, J.H.5    Ma, Z.F.6
  • 34
    • 84863018775 scopus 로고    scopus 로고
    • Aptamers and their biological applications
    • K.M. Song, S. Lee, and C. Ban Aptamers and their biological applications Sensors 12 2012 612 631
    • (2012) Sensors , vol.12 , pp. 612-631
    • Song, K.M.1    Lee, S.2    Ban, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.