1
-
-
85062736545
-
-
Hsieh J. Computed tomography: principles, design, artifacts, and recent advances. SPIE 2003;155–160:199–200, 0-8194-4425-1
-
Hsieh J. Computed tomography: principles, design, artifacts, and recent advances. SPIE 2003;155–160:199–200, 0-8194-4425-1.
-
-
-
-
2
-
-
0842323879
-
Multislice CT: technical principles and future trends
-
PID: 14989605
-
Prokop M. Multislice CT: technical principles and future trends. Eur Radiol. 2003;13(5):M3–13.
-
(2003)
Eur Radiol
, vol.13
, Issue.5
, pp. 3-13
-
-
Prokop, M.1
-
3
-
-
85062751298
-
The optimal dose reduction level using iterative reconstruction with prospective ECG-triggered coronary CTA using 256-slice MDCT
-
Hou Y, Xu S, Guo W et al. The optimal dose reduction level using iterative reconstruction with prospective ECG-triggered coronary CTA using 256-slice MDCT. Eur J Radiol. 2012;6:1266–74.
-
(2012)
Eur J Radiol
, vol.6
, pp. 1266-1274
-
-
Hou, Y.1
Xu, S.2
Guo, W.3
-
4
-
-
84878598953
-
Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations
-
Neroladaki A, Botsikas D, Boudabbous, et al. Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations. Eur Radiol. 2013;3:360–6.
-
(2013)
Eur Radiol
, vol.3
, pp. 360-366
-
-
Neroladaki, A.1
Botsikas, D.2
-
5
-
-
84891964295
-
-
Buzug TM. Computed tomography: from photon statistics to modern cone-beam CT. Berlin: Springer; 2008. p. 476–79 and references therein
-
Buzug TM. Computed tomography: from photon statistics to modern cone-beam CT. Berlin: Springer; 2008. p. 476–79 and references therein.
-
-
-
-
6
-
-
77249131155
-
CT coronary angiography: 256-slice and 320-detector row scanners
-
PID: 20425186
-
Hsiao EM, Rybicki FJ, Steigner M. CT coronary angiography: 256-slice and 320-detector row scanners. Curr Cardiol Rep. 2010;12(1):68–75.
-
(2010)
Curr Cardiol Rep
, vol.12
, Issue.1
, pp. 68-75
-
-
Hsiao, E.M.1
Rybicki, F.J.2
Steigner, M.3
-
7
-
-
84912901793
-
Geometrical limitations of computed tomography (CT) scanner resolution. Optical instrumentation in medicine VI
-
Yester MV, Barnes GT. Geometrical limitations of computed tomography (CT) scanner resolution. Optical instrumentation in medicine VI. SPIE. 1977;127:296–303.
-
(1977)
SPIE
, vol.127
, pp. 296-303
-
-
Yester, M.V.1
Barnes, G.T.2
-
9
-
-
85062740875
-
-
Toshiba, Yasuo S, Nasu-gun, Hiroaki M, Hiroshi A. US Patent 6,396,898. 2001.
-
(2001)
Hiroshi A. US Patent 6,396
, pp. 898
-
-
-
10
-
-
85062748646
-
Von Der Haar T, Kohl G, Bruder H. Method for manufacturing detector system for a computed tomography apparatus
-
Siemens: Von Der Haar T, Kohl G, Bruder H. Method for manufacturing detector system for a computed tomography apparatus. US Patent 6,137,859. 2000.
-
(2000)
US Patent 6,137
, pp. 859
-
-
-
11
-
-
85062748878
-
Hoffman DM: Solid-state CT detector modules with improved scintillator/diode coupling
-
GE: Hoffman DM: Solid-state CT detector modules with improved scintillator/diode coupling. US Patent 6,717,150 B2. 2004.
-
(2004)
US Patent 6,717
, vol.150
, pp. 2
-
-
-
13
-
-
0000002311
-
A unified approach to the performance of photographic film, television pick-up tubes, and the human eye
-
Rose A. A unified approach to the performance of photographic film, television pick-up tubes, and the human eye. J Soc Motion Pict Telev Eng. 1946;47:273–94.
-
(1946)
J Soc Motion Pict Telev Eng
, vol.47
, pp. 273-294
-
-
Rose, A.1
-
14
-
-
85062745050
-
Radiology of the skull and brain, technical aspects of computed tomography, vol-5
-
Saint Louis: The C.V. Mosby company
-
Peschmann KR. Radiology of the skull and brain, technical aspects of computed tomography, vol-5. In: Newton TH, Potts DG, editors. Saint Louis: The C.V. Mosby company; 1981. p. 4112–26.
-
(1981)
Newton TH
, pp. 4112-4126
-
-
Peschmann, K.R.1
Potts, D.G.2
-
16
-
-
85062740276
-
-
IEC 62220-1 (2003)
-
IEC 62220-1 (2003).
-
-
-
-
17
-
-
85062749140
-
-
Granfors PR in AAPM. DQE methodology—step by step. 2003. Accessed Oct 2012
-
Granfors PR in AAPM. DQE methodology—step by step. 2003. http://www.aapm.org/meetings/03AM/pdf/9811-91358.pdf. Accessed Oct 2012.
-
-
-
-
18
-
-
0037393386
-
An experimental comparison of detector performance for direct and indirect digital radiography systems
-
and references therein
-
Sameia E, Flynn MJ. An experimental comparison of detector performance for direct and indirect digital radiography systems. Med Phys. 2003;30(4):608–22. and references therein.
-
(2003)
Med Phys
, vol.30
, Issue.4
, pp. 608-622
-
-
Sameia, E.1
Flynn, M.J.2
-
19
-
-
34249008167
-
Assessment of detective quantum efficiency: intercomparison of a recently introduced international standard with prior methods
-
PID: 17517933
-
Ranger NT, Samei E, Dobbins JT, et al. Assessment of detective quantum efficiency: intercomparison of a recently introduced international standard with prior methods. Radiology. 2007;243(3):785–95.
-
(2007)
Radiology
, vol.243
, Issue.3
, pp. 785-795
-
-
Ranger, N.T.1
Samei, E.2
Dobbins, J.T.3
-
20
-
-
66749147327
-
Extension of DQE to include scatter, grid, magnification, and focal spot blur: a new experimental technique and metric
-
Ranger NT. Extension of DQE to include scatter, grid, magnification, and focal spot blur: a new experimental technique and metric. Med Imaging Phys Med Imaging Proc SPIE 2009; 7258(72581A):1–12.
-
(2009)
Med Imaging Phys Med Imaging Proc SPIE
, vol.7258
, Issue.72581A
, pp. 1-12
-
-
Ranger, N.T.1
-
21
-
-
85062752905
-
Detector z-axis gain non-uniformity correction in a computed tomography system
-
Hu H, Besson GM, He HD. Detector z-axis gain non-uniformity correction in a computed tomography system. US Patent 5,734,691. 1998.
-
(1998)
US Patent 5,734
, pp. 691
-
-
Hu, H.1
Besson, G.M.2
He, H.D.3
-
22
-
-
85062750129
-
Method and apparatus for calibrating detector spectral response
-
Wu X, LeBlanc J, Walter DJ. Method and apparatus for calibrating detector spectral response. US Patent US 6,848,827 B2. 2005.
-
(2005)
US Patent US 6,848
, vol.827
, pp. 2
-
-
Wu, X.1
LeBlanc, J.2
Walter, D.J.3
-
23
-
-
85062742915
-
Method for determining correction coefficients for detector channels for a computed tomography
-
Stierstorfer K, Stoeger-Haselboeck T. Method for determining correction coefficients for detector channels for a computed tomography. US Patent: US 7,056,018 B2. 2006.
-
(2006)
US Patent: US 7,056
, vol.18
, pp. 2
-
-
Stierstorfer, K.1
Stoeger-Haselboeck, T.2
-
24
-
-
0027637986
-
Geometrical calibration of X-ray imaging chains for three-dimensional reconstruction
-
Rouge’e A, Picard C, Ponchut C, et al. Geometrical calibration of X-ray imaging chains for three-dimensional reconstruction. Comput Med Imaging Graph 1993; 17(4–5):295–300.
-
(1993)
Comput Med Imaging Graph
, vol.17
, Issue.4-5
, pp. 295-300
-
-
Rouge’e, A.1
Picard, C.2
Ponchut, C.3
-
25
-
-
23844531734
-
Resolution enhancement of X-ray CT by spatial and temporal MLEM deconvolution correction
-
Carmi R, Braunstein D, Shapiro O. Resolution enhancement of X-ray CT by spatial and temporal MLEM deconvolution correction. Nucl Sci Symp Conf Rec. 2004;5:2765–8.
-
(2004)
Nucl Sci Symp Conf Rec
, vol.5
, pp. 2765-2768
-
-
Carmi, R.1
Braunstein, D.2
Shapiro, O.3
-
26
-
-
0034257871
-
Investigation of a solid-state detector for advanced computed tomography
-
PID: 11127606, COI: 1:STN:280:DC%2BD3M7gsVensQ%3D%3D
-
Hsieh J, Gurmen OE, King KF. Investigation of a solid-state detector for advanced computed tomography. IEEE Trans Med Imaging. 2000;19(9):930–40.
-
(2000)
IEEE Trans Med Imaging
, vol.19
, Issue.9
, pp. 930-940
-
-
Hsieh, J.1
Gurmen, O.E.2
King, K.F.3
-
30
-
-
0037149996
-
Inorganic scintillators in medical imaging
-
PID: 12030568
-
van Eijk CWE. Inorganic scintillators in medical imaging. Phys Med Biol. 2002;47:R85–106.
-
(2002)
Phys Med Biol
, vol.47
, pp. 85-106
-
-
van Eijk, C.W.E.1
-
31
-
-
33645289666
-
Scintillation detectors for X-rays
-
COI: 1:CAS:528:DC%2BD28XjvFaqu78%3D
-
Nikl M. Scintillation detectors for X-rays. Meas Sci Technol. 2006;17:R37–54.
-
(2006)
Meas Sci Technol
, vol.17
, pp. 37-54
-
-
Nikl, M.1
-
32
-
-
0025722120
-
Phosphors for X-ray detectors in computed tomography
-
Rossner W, Grabmaier BC. Phosphors for X-ray detectors in computed tomography. J Lumin. 1991;48–49:29–36.
-
(1991)
J Lumin
, vol.48-49
, pp. 29-36
-
-
Rossner, W.1
Grabmaier, B.C.2
-
33
-
-
0037118539
-
Light output and energy resolution of Ce3 + -doped scintillators
-
COI: 1:CAS:528:DC%2BD38XkslGlu7s%3D
-
Dorenbos P. Light output and energy resolution of Ce3 + -doped scintillators. Nucl Instrum Methods Phys Res A. 2002;486:208–13.
-
(2002)
Nucl Instrum Methods Phys Res A
, vol.486
, pp. 208-213
-
-
Dorenbos, P.1
-
34
-
-
0024731886
-
A scintillator Gd2O2S:Pr, Ce, F for X-ray computed tomography
-
COI: 1:CAS:528:DyaL1MXmsVCju7s%3D
-
Yamada H, Suzuki A, Uchida Y, et al. A scintillator Gd2O2S:Pr, Ce, F for X-ray computed tomography. J Electrochem Soc. 1989;136:2713–6.
-
(1989)
J Electrochem Soc
, vol.136
, pp. 2713-2716
-
-
Yamada, H.1
Suzuki, A.2
Uchida, Y.3
-
35
-
-
0037680287
-
Development of the HiLight™ scintillator for computer tomography medical imaging
-
COI: 1:CAS:528:DC%2BD3sXkt1eitLo%3D
-
Duclos SJ, Greskovich CD, Lyons RJ, et al. Development of the HiLight™ scintillator for computer tomography medical imaging. Nucl Instrum Methods Phys Res A. 2003;505:68–71.
-
(2003)
Nucl Instrum Methods Phys Res A
, vol.505
, pp. 68-71
-
-
Duclos, S.J.1
Greskovich, C.D.2
Lyons, R.J.3
-
37
-
-
11344253041
-
Perspectives on the future development of new scintillators
-
COI: 1:CAS:528:DC%2BD2MXitVSrtg%3D%3D
-
Melcher CL. Perspectives on the future development of new scintillators. Nucl Instrum Methods Phys Res A. 2005;537:6–14.
-
(2005)
Nucl Instrum Methods Phys Res A
, vol.537
, pp. 6-14
-
-
Melcher, C.L.1
-
38
-
-
38849113830
-
Characteristics of a nonstoichiometric gd3 + δ(Al, Ga)5−δO12:Ce garnet scintillator
-
COI: 1:CAS:528:DC%2BD1cXitlynsbo%3D
-
Kanai T, Satoh M, Miura I. Characteristics of a nonstoichiometric gd3 + δ(Al, Ga)5−δO12:Ce garnet scintillator. J Am Ceram Soc. 2008;91:456–62.
-
(2008)
J Am Ceram Soc
, vol.91
, pp. 456-462
-
-
Kanai, T.1
Satoh, M.2
Miura, I.3
-
39
-
-
0035355239
-
New semiconductor scintillators ZnSe(Te, O) and integrated radiation detectors based thereon
-
COI: 1:CAS:528:DC%2BD3MXmvVaht74%3D
-
Ryzhikov V, Starzhinskiy N, Gal’chinetskii L, et al. New semiconductor scintillators ZnSe(Te, O) and integrated radiation detectors based thereon. IEEE Trans Nucl Sci Vol. 2001;48(3):356–9.
-
(2001)
IEEE Trans Nucl Sci Vol
, vol.48
, Issue.3
, pp. 356-359
-
-
Ryzhikov, V.1
Starzhinskiy, N.2
Gal’chinetskii, L.3
-
40
-
-
40049100659
-
Strontium and barium iodide high light yield scintillators
-
Cherepy NJ, Hull G, Drobshoff SA, et al. Strontium and barium iodide high light yield scintillators. Appl Phys Lett. 2008;92:083508-1–3.
-
(2008)
Appl Phys Lett
, vol.92
, pp. 1-3
-
-
Cherepy, N.J.1
Hull, G.2
Drobshoff, S.A.3
-
41
-
-
0042377120
-
Back illuminated photodiodes for multislice CT
-
Luhta R, Mattson R, Taneja N, et al. Back illuminated photodiodes for multislice CT. Proc SPIE. 2003;5030:235–45.
-
(2003)
Proc SPIE
, vol.5030
, pp. 235-245
-
-
Luhta, R.1
Mattson, R.2
Taneja, N.3
-
42
-
-
3042549096
-
Design and performance of a 32-slice CT detector system using back-illuminated photodiodes
-
Utrup S, Chappo M, Harwood B, et al. Design and performance of a 32-slice CT detector system using back-illuminated photodiodes. Proc SPIE. 2004;5368:40–51.
-
(2004)
Proc SPIE
, vol.5368
, pp. 40-51
-
-
Utrup, S.1
Chappo, M.2
Harwood, B.3
-
43
-
-
67650112059
-
Electrical crosstalk in front-illuminated photodiode array with different guard ring designs for medical CT applications
-
Ji F. Electrical crosstalk in front-illuminated photodiode array with different guard ring designs for medical CT applications. Nucl Instrum Methods Phys Res Sect A 2009; 607(1):150–3.
-
(2009)
Nucl Instrum Methods Phys Res Sect A
, vol.607
, Issue.1
, pp. 150-153
-
-
Ji, F.1
-
44
-
-
85062747994
-
-
Analog Devices. 128 channel, 24-bit current to digital ADC—ADAS1128. Accessed Oct 2012
-
Analog Devices. 128 channel, 24-bit current to digital ADC—ADAS1128. http://www.analog.com. Accessed Oct 2012.
-
-
-
-
45
-
-
85062751798
-
Method for the production of three-dimensional circuit arrangement. Siemens Aktiengesellschaft
-
United States Patent No. 5,741,733, Bertagnolli. Method for the production of three-dimensional circuit arrangement. Siemens Aktiengesellschaft, Munich, 21 April 1998.
-
(1998)
Munich
, pp. 21
-
-
-
46
-
-
0020658505
-
Coherent scatter in diagnostic radiology
-
PID: 6843512, COI: 1:STN:280:DyaL3s7ptFyrtQ%3D%3D
-
Johns PC, Yaffe MJ. Coherent scatter in diagnostic radiology. Med Phys. 1983;10:40–50.
-
(1983)
Med Phys
, vol.10
, pp. 40-50
-
-
Johns, P.C.1
Yaffe, M.J.2
-
47
-
-
43149105001
-
Spectral analysis of scattered radiation in CT
-
Engel KJ. Spectral analysis of scattered radiation in CT. Proc SPIE. 2008;6913:69131R.
-
(2008)
Proc SPIE
, vol.69131R
, pp. 6913
-
-
Engel, K.J.1
-
48
-
-
34547327743
-
A quantum theory of the scattering of X-rays by light elements
-
COI: 1:CAS:528:DyaB3sXhvVSqtw%3D%3D
-
Compton AH. A quantum theory of the scattering of X-rays by light elements. Phys Rev. 1923;21:483–502.
-
(1923)
Phys Rev
, vol.21
, pp. 483-502
-
-
Compton, A.H.1
-
49
-
-
66749083954
-
Impact of scattered radiation on spectral CT
-
Wiegert J, Engel KJ, Herrmann C. Impact of scattered radiation on spectral CT. Proc SPIE. 2009;7258:72583X.
-
(2009)
Proc SPIE
, vol.7258
, pp. 72583
-
-
Wiegert, J.1
Engel, K.J.2
Herrmann, C.3
-
50
-
-
0020364887
-
Compton scatter effects in CT reconstruction
-
PID: 7162472, COI: 1:CAS:528:DyaL3sXkt1Kjsw%3D%3D
-
Glover GH. Compton scatter effects in CT reconstruction. Med Phys. 1982;9:860–7.
-
(1982)
Med Phys
, vol.9
, pp. 860-867
-
-
Glover, G.H.1
-
51
-
-
37549072259
-
X-ray scattering in single- and dual-source CT
-
PID: 18293587
-
Engel KJ, Herrmann C, Zeitler G. X-ray scattering in single- and dual-source CT. Med Phys. 2008;35:318–32.
-
(2008)
Med Phys
, vol.35
, pp. 318-332
-
-
Engel, K.J.1
Herrmann, C.2
Zeitler, G.3
-
52
-
-
79960241325
-
A general framework and review of scatter correction methods in X-ray cone-beam computerized tomography. Part 1: scatter compensation approaches
-
PID: 21859031
-
Rührnschopf EP, Klingenbeck K. A general framework and review of scatter correction methods in X-ray cone-beam computerized tomography. Part 1: scatter compensation approaches. Med Phys. 2011;38:4296–311.
-
(2011)
Med Phys
, vol.38
, pp. 4296-4311
-
-
Rührnschopf, E.P.1
Klingenbeck, K.2
-
53
-
-
80052405857
-
A general framework and review of scatter correction methods in cone beam CT. Part 2: scatter estimation approaches
-
Rührnschopf EP, Klingenbeck K. A general framework and review of scatter correction methods in cone beam CT. Part 2: scatter estimation approaches. Med Phys. 2011;38:5186–99.
-
(2011)
Med Phys
, vol.38
, pp. 5186-5199
-
-
Rührnschopf, E.P.1
Klingenbeck, K.2
-
54
-
-
33645196336
-
Radiation exposure and image quality in X-ray diagnostic radiology
-
New York: Springer
-
Aichinger H, Dierker J, Joite-Barfuss S, et al. Radiation exposure and image quality in X-ray diagnostic radiology. In: Aichinger H, editor. New York: Springer; 2004. p. 59–65.
-
(2004)
Aichinger H, editor
, pp. 59-65
-
-
Aichinger, H.1
Dierker, J.2
Joite-Barfuss, S.3
-
55
-
-
43149097187
-
Two-dimensional anti-scatter-grids for computed tomography detectors
-
Vogtmeier G, Dorscheid R, Engel KJ, et al. Two-dimensional anti-scatter-grids for computed tomography detectors. Proc SPIE. 2008;6913:691359.
-
(2008)
Proc SPIE
, vol.6913
, pp. 691359
-
-
Vogtmeier, G.1
Dorscheid, R.2
Engel, K.J.3
-
56
-
-
80052396545
-
Improved CT image quality using a new fully physical imaging chain
-
Wiegert J, Bertram M, Wiesner S, et al. Improved CT image quality using a new fully physical imaging chain. Proc SPIE. 2010;7622:76221I.
-
(2010)
Proc SPIE
, vol.7622
, pp. 76221
-
-
Wiegert, J.1
Bertram, M.2
Wiesner, S.3
-
57
-
-
35148898333
-
Coupling the use of anti-scatter grid with analytical scatter estimation in cone beam CT
-
Rinkel J, Gerfault L, Esteve F, et al. Coupling the use of anti-scatter grid with analytical scatter estimation in cone beam CT. Proc SPIE. 2007;6510:65102E.
-
(2007)
Proc SPIE
, vol.6510
, pp. 65102
-
-
Rinkel, J.1
Gerfault, L.2
Esteve, F.3
-
58
-
-
0017108614
-
Energy-selective reconstruction in X-ray computerized tomography
-
PID: 967922, COI: 1:STN:280:DyaE2s%2FhtlOntg%3D%3D
-
Alvarez RE, Macovski A. Energy-selective reconstruction in X-ray computerized tomography. Phys Med Biol. 1976;21(5):733–44.
-
(1976)
Phys Med Biol
, vol.21
, Issue.5
, pp. 733-744
-
-
Alvarez, R.E.1
Macovski, A.2
-
59
-
-
0017811386
-
Split detector computed tomography: a preliminary report
-
PID: 619422, COI: 1:STN:280:DyaE1c%2Fntlykuw%3D%3D
-
Brooks RA, Di Chiro G. Split detector computed tomography: a preliminary report. Radiology. 1978;126(1):255–7.
-
(1978)
Radiology
, vol.126
, Issue.1
, pp. 255-257
-
-
Brooks, R.A.1
Di Chiro, G.2
-
60
-
-
33846627891
-
Material separation with dual-layer CT. Presented at the IEEE-MIC Conference
-
Carmi R. Material separation with dual-layer CT. Presented at the IEEE-MIC Conference. Puerto Rico: Wyndham El Conquistador; 23–29 Oct 2005.
-
(2005)
Puerto Rico: Wyndham El Conquistador
, pp. 23-29
-
-
Carmi, R.1
-
61
-
-
85062737268
-
Double decker detector for spectral CT
-
Altman A, Shapiro O, Levene S, et al. Double decker detector for spectral CT. US States Patent US 7,968,853. 2006.
-
(2006)
US States Patent US 7,968
, pp. 853
-
-
Altman, A.1
Shapiro, O.2
Levene, S.3
-
62
-
-
0018667403
-
Noise considerations in dual energy CT scanning
-
PID: 492076, COI: 1:STN:280:DyaL3c%2Fjt1eltQ%3D%3D
-
Kelcz F, Joseph PM, Hilal SK. Noise considerations in dual energy CT scanning. Med Phys. 1979;6(5):418–25.
-
(1979)
Med Phys
, vol.6
, Issue.5
, pp. 418-425
-
-
Kelcz, F.1
Joseph, P.M.2
Hilal, S.K.3
-
63
-
-
67649188926
-
-
Goshen L, Sosna J, Carmi R, et al. An Iodine-Calcium Separation Analysis and Virtually Non-Contrasted Image Generation Obtained with Single Source Dual Energy MDCT. IEEE Nucl Sci Symp Conf Rec. 2008;NSS ’08:3868–70
-
Goshen L, Sosna J, Carmi R, et al. An Iodine-Calcium Separation Analysis and Virtually Non-Contrasted Image Generation Obtained with Single Source Dual Energy MDCT. IEEE Nucl Sci Symp Conf Rec. 2008;NSS ’08:3868–70.
-
-
-
-
64
-
-
0031213227
-
Room-temperature compound semiconductor radiation detectors
-
COI: 1:CAS:528:DyaK2sXltlajtrw%3D
-
McGregor DS, Hermon H. Room-temperature compound semiconductor radiation detectors. Nucl Instrum Methods Phys A. 1997;395(1):101–24.
-
(1997)
Nucl Instrum Methods Phys A
, vol.395
, Issue.1
, pp. 101-124
-
-
McGregor, D.S.1
Hermon, H.2
-
65
-
-
67649215145
-
Towards direct conversion detectors for medical imaging with X-rays
-
Nucl. Sci. Symp. Conf. Rec, NSS
-
Overdick M, Baumer C, Engel KJ et al. Towards direct conversion detectors for medical imaging with X-rays. In: IEEE 2008 Nucl. Sci. Symp. Conf. Rec. (NSS 2008), p. 1527–35. doi:10.1109/NSSMIC.2008.4775117.
-
(2008)
IEEE
, vol.2008
, pp. 1527-1535
-
-
Overdick, M.1
Baumer, C.2
Engel, K.J.3
-
66
-
-
78650064882
-
-
Steadman R, Herrmann C, Mülhens O, et al. ChromAIX: a high-rate energy-resolving photon-counting ASIC for spectral computed tomography. Proc SPIE 2010;7622:762220-1–8
-
Steadman R, Herrmann C, Mülhens O, et al. ChromAIX: a high-rate energy-resolving photon-counting ASIC for spectral computed tomography. Proc SPIE 2010;7622:762220-1–8.
-
-
-
-
67
-
-
67649207868
-
Photon counting energy dispersive detector arrays for X-ray imaging
-
PID: 19920884
-
Iwanczyk JS, Nygård E, Meirav O, et al. Photon counting energy dispersive detector arrays for X-ray imaging. IEEE Trans Nucl Sci. 2009;56(3):535–42. doi:10.1109/TNS.2009.2013709.
-
(2009)
IEEE Trans Nucl Sci
, vol.56
, Issue.3
, pp. 535-542
-
-
Iwanczyk, J.S.1
Nygård, E.2
Meirav, O.3
-
68
-
-
35348948593
-
-
Ballabriga R, Campbell M, Heijne EHM, et al. The Medipix3 prototype, a pixel readout chip working in single photon counting mode with improved spectrometric performance. IEEE Trans Nucl Sci 2007; NS-54:1824–29
-
Ballabriga R, Campbell M, Heijne EHM, et al. The Medipix3 prototype, a pixel readout chip working in single photon counting mode with improved spectrometric performance. IEEE Trans Nucl Sci 2007; NS-54:1824–29.
-
-
-
-
69
-
-
72349092641
-
Comparison of pixellated CdZnTe, CdTe and Si Sensors with the Simultaneously Counting and Integrating CIX ASIC
-
COI: 1:CAS:528:DC%2BC3cXmvVWhtg%3D%3D
-
Fink J, Kraft E, Krüger H, et al. Comparison of pixellated CdZnTe, CdTe and Si Sensors with the Simultaneously Counting and Integrating CIX ASIC. IEEE Trans Nucl Sci. 2009;56(6):3819–27.
-
(2009)
IEEE Trans Nucl Sci
, vol.56
, Issue.6
, pp. 3819-3827
-
-
Fink, J.1
Kraft, E.2
Krüger, H.3
-
70
-
-
66749143087
-
-
del Risco Norrlid L, Fredenberg E, Hemmendorff M, et al. Imaging of small children with a prototype for photon counting tomosynthesis. Proc SPIE 2009;7258:72581O-1–9
-
del Risco Norrlid L, Fredenberg E, Hemmendorff M, et al. Imaging of small children with a prototype for photon counting tomosynthesis. Proc SPIE 2009;7258:72581O-1–9.
-
-
-
-
71
-
-
58149231346
-
Energy-resolved CT: first experimental results
-
PID: 18799830
-
Shikhaliev PM. Energy-resolved CT: first experimental results. Phys Med Biol. 2008;53:5595–613. doi:10.1088/0031-9155/53/20/002.
-
(2008)
Phys Med Biol
, vol.53
, pp. 5595-5613
-
-
Shikhaliev, P.M.1
-
72
-
-
77749292346
-
Radiation dose reduction using a CdZnTe-based computed tomography system: comparison to flat-panel detectors
-
COI: 1:CAS:528:DC%2BC3cXivFaju7s%3D
-
Le HQ, Ducote JL, Molloi S. Radiation dose reduction using a CdZnTe-based computed tomography system: comparison to flat-panel detectors. Med Phys. 2010;37(3):1225–36.
-
(2010)
Med Phys
, vol.37
, Issue.3
, pp. 1225-1236
-
-
Le, H.Q.1
Ducote, J.L.2
Molloi, S.3
-
73
-
-
79954581517
-
MicroCT with energy-resolved photon-counting detectors
-
PID: 21464527, COI: 1:STN:280:DC%2BC3MvitF2ksQ%3D%3D
-
Wang X, Meier D, Mikkelsen S, et al. MicroCT with energy-resolved photon-counting detectors. Phys Med Biol. 2011;56(9):2791–816. doi:10.1088/0031-9155/56/9/011.
-
(2011)
Phys Med Biol
, vol.56
, Issue.9
, pp. 2791-2816
-
-
Wang, X.1
Meier, D.2
Mikkelsen, S.3
-
74
-
-
48349103232
-
Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography
-
Schlomka JP. Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography. Phys Med Biol 2008;53:4031–47.
-
(2008)
Phys Med Biol
, vol.53
, pp. 4031-4047
-
-
Schlomka, J.P.1
-
75
-
-
67650168121
-
Contrast agent recognition in small animal CT using the Medipix2 detector
-
COI: 1:CAS:528:DC%2BD1MXoslWrur8%3D
-
Firsching M, Butler AP, Scott N. Contrast agent recognition in small animal CT using the Medipix2 detector. Nucl Instrum Methods Phys Res Sect A. 2009;607(1):179–82.
-
(2009)
Nucl Instrum Methods Phys Res Sect A
, vol.607
, Issue.1
, pp. 179-182
-
-
Firsching, M.1
Butler, A.P.2
Scott, N.3
-
76
-
-
84860372496
-
-
Kappler S, Hannemann T, Kraft E. First results from a hybrid prototype CT scanner for exploring benefits of quantum-counting in clinical CT (Proceedings Paper), SPIE 2012;8313:83130X-83130X-11 9780819489623
-
Kappler S, Hannemann T, Kraft E. First results from a hybrid prototype CT scanner for exploring benefits of quantum-counting in clinical CT (Proceedings Paper), SPIE 2012;8313:83130X-83130X-11, 9780819489623. doi: 10.1117/12.911295.
-
-
-
-
77
-
-
77951153554
-
Enabling photon counting clinical X-ray CT
-
Taguchi K, Kudo H, Srivastava S et al. Enabling photon counting clinical X-ray CT, IEEE NSS MIC 2009;M13-45:3581–85.
-
(2009)
IEEE NSS MIC
, vol.3581-85
, pp. 13-45
-
-
Taguchi, K.1
Kudo, H.2
Srivastava, S.3
-
78
-
-
34547137886
-
K-edge imaging in X-ray computed tomography using multi-bin photon counting detectors
-
PID: 17634657, COI: 1:CAS:528:DC%2BD2sXhtVeitbbL
-
Roessl E, Proksa R. K-edge imaging in X-ray computed tomography using multi-bin photon counting detectors. Phys Med Biol. 2007;52:4679–96.
-
(2007)
Phys Med Biol
, vol.52
, pp. 4679-4696
-
-
Roessl, E.1
Proksa, R.2
-
79
-
-
4644266911
-
New X-ray tube performance in computed tomography by introducing the rotating envelope tube technology
-
PID: 15487753
-
Schardt P, Deuringer J, Freudenberger J, et al. New X-ray tube performance in computed tomography by introducing the rotating envelope tube technology. Med Phys. 2004;31(9):2699–706.
-
(2004)
Med Phys
, vol.31
, Issue.9
, pp. 2699-2706
-
-
Schardt, P.1
Deuringer, J.2
Freudenberger, J.3
-
81
-
-
78049394698
-
-
Frutschy K, Neculaes B, Inzinna L et al. High Power distributed X-ray source. Proc SPIE 2010;7622:76221H. :. Novel CT concept
-
Frutschy K, Neculaes B, Inzinna L et al. High Power distributed X-ray source. Proc SPIE 2010;7622:76221H. doi:10.1117/12.843743. Novel CT concept.
-
-
-
|