메뉴 건너뛰기




Volumn 7622, Issue PART 1, 2010, Pages

Improved CT image quality using a new fully physical imaging chain

Author keywords

Anti scatter grids; Beam hardening correction; Computed tomography; Monte Carlo simulations; Scatter correction; Scatter to Primary ratio; X ray scatter

Indexed keywords

ANTI-SCATTER GRIDS; BEAM HARDENING CORRECTION; COMPUTED TOMOGRAPHY; MONTE CARLO SIMULATION; SCATTER CORRECTION; SCATTER-TO- PRIMARY RATIO; X-RAY SCATTER;

EID: 80052396545     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.844564     Document Type: Conference Paper
Times cited : (5)

References (17)
  • 1
    • 0020030615 scopus 로고
    • Scattered radiation in fan beam imaging systems
    • Johns, P. and Yaffe, M., "Scattered radiation in fan beam imaging systems.," Med Phys 9(2), 231-9 (1982).
    • (1982) Med Phys , vol.9 , Issue.2 , pp. 231-239
    • Johns, P.1    Yaffe, M.2
  • 2
    • 0019978056 scopus 로고
    • The effects of scatter in X-ray computed tomography
    • Joseph, P. and Spital, R., "The effects of scatter in X-ray computed tomography.," Med Phys 9(4), 464-72 (1982).
    • (1982) Med Phys , vol.9 , Issue.4 , pp. 464-472
    • Joseph, P.1    Spital, R.2
  • 3
    • 0020364887 scopus 로고
    • Compton scatter effects in CT reconstructions
    • Glover, G., "Compton scatter effects in CT reconstructions.," Med Phys 9(6), 860-7 (1982).
    • (1982) Med Phys , vol.9 , Issue.6 , pp. 860-867
    • Glover, G.1
  • 4
    • 0035110308 scopus 로고    scopus 로고
    • Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter
    • Feb
    • Siewerdsen, J. H. and Jaifray, D. A., "Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter.," Med Phys 28. 220-31 (Feb 2001).
    • (2001) Med Phys , vol.28 , pp. 220-231
    • Siewerdsen, J.H.1    Jaifray, D.A.2
  • 5
    • 0035053536 scopus 로고    scopus 로고
    • Effect of scattered radiation on image noise in cone beam CT
    • Apr
    • Endo, M., Tsunoo, T., Nakamori, N., and Yoshida, K., "Effect of scattered radiation on image noise in cone beam CT.," Med Phys 28, 469-474 (Apr 2001).
    • (2001) Med Phys , vol.28 , pp. 469-474
    • Endo, M.1    Tsunoo, T.2    Nakamori, N.3    Yoshida, K.4
  • 6
    • 37549072259 scopus 로고    scopus 로고
    • X-ray scattering in single- and dual-source ct
    • Jan
    • Engel, K. J., Herrmann, C., and Zeitler, G., "X-ray scattering in single- and dual-source ct.," Med Phys 35, 318-332 (Jan 2008).
    • (2008) Med Phys , vol.35 , pp. 318-332
    • Engel, K.J.1    Herrmann, C.2    Zeitler, G.3
  • 8
    • 0035103636 scopus 로고    scopus 로고
    • Correction of scatter in megavoltage cone-beam CT
    • Mar
    • Spies, L., Ebert, M. Groh, B., Hesse, B., and Bortfeld, T., "Correction of scatter in megavoltage cone-beam CT.," Phys Med Biol 46, 821-33 (Mar 2001).
    • (2001) Phys Med Biol , vol.46 , pp. 821-833
    • Spies, L.1    Ebert Groh, M.B.2    Hesse, B.3    Bortfeld, T.4
  • 9
    • 23844496562 scopus 로고    scopus 로고
    • Model based scatter correction for cone-beam computed tomography
    • Flynn, M. J., ed., SPIE, San Diego, CA, USA
    • Wiegert, J., Bertram, M., Rose, G., and Aach, T., "Model based scatter correction for cone-beam computed tomography," in [Medical Imaging 2005: Physics of Medical Imaging], Flynn, M. J., ed., 5745(1), 271 282, SPIE, San Diego, CA, USA (2005).
    • (2005) Medical Imaging 2005: Physics of Medical Imaging , vol.5745 , Issue.1 , pp. 271-282
    • Wiegert, J.1    Bertram, M.2    Rose, G.3    Aach, T.4
  • 11
    • 33745329777 scopus 로고    scopus 로고
    • Scatter correction for cone-beam computed tomography using simulated object models
    • Flynn, M. J. and Hsieh, J., eds., SPIE
    • Bertram, M., Wiegert, J., and Rose, G., "Scatter correction for cone-beam computed tomography using simulated object models," in [Medical Imaging 2006: Physics of Medical Imaging], Flynn, M. J. and Hsieh, J., eds., 6142(1), 6142-48, SPIE (2006).
    • (2006) Medical Imaging 2006: Physics of Medical Imaging , vol.6142 , Issue.1 , pp. 6142-6148
    • Bertram, M.1    Wiegert, J.2    Rose, G.3
  • 13
    • 0032605125 scopus 로고    scopus 로고
    • Efficient object scatter correction algorithm for third and fourth generation CT scanners
    • Ohnesorge, B., Flohr, T., and Klingenbeck-Regn, K., "Efficient object scatter correction algorithm for third and fourth generation CT scanners.," Eur Radiol 9(3), 563-9 (1999).
    • (1999) Eur Radiol , vol.9 , Issue.3 , pp. 563-569
    • Ohnesorge, B.1    Flohr, T.2    Klingenbeck-Regn, K.3
  • 14
    • 0023212881 scopus 로고
    • Scatter estimation for a digital radiographic system using convolution filtering
    • Love, L. and Kruger, R., "Scatter estimation for a digital radiographic system using convolution filtering.," Med Phys 14(2), 178-85 (1987).
    • (1987) Med Phys , vol.14 , Issue.2 , pp. 178-185
    • Love, L.1    Kruger, R.2
  • 15
    • 0030866641 scopus 로고    scopus 로고
    • Extraction of primary signal from epids using only forward convolution
    • Sep
    • Hansen, V. N., Swindell, W., and Evans, P. M., "Extraction of primary signal from epids using only forward convolution.," Med Phys 24, 1477-1484 (Sep 1997).
    • (1997) Med Phys , vol.24 , pp. 1477-1484
    • Hansen, V.N.1    Swindell, W.2    Evans, P.M.3
  • 16
    • 84978929005 scopus 로고    scopus 로고
    • Scatter correction for flat detector cone-beam ct based on simulated sphere models
    • Bertram, M., Hohinanri, S., and Wiegert, J., "Scatter correction for flat detector cone-beam ct based on simulated sphere models," Medical Physics 34(6), 2342-2343 (2007).
    • (2007) Medical Physics , vol.34 , Issue.6 , pp. 2342-2343
    • Bertram, M.1    Hohinanri, S.2    Wiegert, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.