-
1
-
-
0029085936
-
Needle phobia: A neglected diagnosis
-
Hamilton JG. Needle phobia: a neglected diagnosis. J Fam Pract. 1995; 41:169-175.
-
(1995)
J Fam Pract
, vol.41
, pp. 169-175
-
-
Hamilton, J.G.1
-
4
-
-
0037123691
-
Reverse iontophoretic monitoring in premature neonates: Feasibility and potential
-
Sekkat N, Naik A, Kalia Y, et al. Reverse iontophoretic monitoring in premature neonates: feasibility and potential. J Control Release. 2002;81: 83-89.
-
(2002)
J Control Release
, vol.81
, pp. 83-89
-
-
Sekkat, N.1
Naik, A.2
Kalia, Y.3
-
6
-
-
33746216901
-
Clinical microdialysis: Current applications and potential use in drug development
-
Brunner M, Derendorf H. Clinical microdialysis: current applications and potential use in drug development. Trends Anal Chem. 2006;25:674-680.
-
(2006)
Trends Anal Chem
, vol.25
, pp. 674-680
-
-
Brunner, M.1
Derendorf, H.2
-
9
-
-
78650406419
-
A high aspect ratio SU-8 fabrication technique for hollow microneedles for transdermal drug delivery and blood extraction
-
Chaudhri B, Ceyssens F, De Moor P, et al. A high aspect ratio SU-8 fabrication technique for hollow microneedles for transdermal drug delivery and blood extraction. J Micromech Microeng. 2010;20:064006.
-
(2010)
J Micromech Microeng
, vol.20
, pp. 064006
-
-
Chaudhri, B.1
Ceyssens, F.2
De Moor, P.3
-
10
-
-
4344666269
-
Microneedle array for transdermal biological fluid extraction and in situ analysis
-
Mukerjee E, Collins S, Isseroff R, et al. Microneedle array for transdermal biological fluid extraction and in situ analysis. Sens Actuators A Phys. 2004;114:267-275.
-
(2004)
Sens Actuators A Phys
, vol.114
, pp. 267-275
-
-
Mukerjee, E.1
Collins, S.2
Isseroff, R.3
-
11
-
-
84892907595
-
Micromachined needles for microbiological sample and drug delivery system
-
20-23 July 2003. Washington, DC: IEEE Computer Society
-
Zhang P, Jullien G. Micromachined needles for microbiological sample and drug delivery system. Proceedings of International Conference on MEMS, NANO and Smart Systems, Banff, Canada, 20-23 July 2003. Washington, DC: IEEE Computer Society; 2003:247-250.
-
(2003)
Proceedings of International Conference on MEMS NANO and Smart Systems Banff Canada
, pp. 247-250
-
-
Zhang, P.1
Jullien, G.2
-
12
-
-
33749080739
-
Microneedle arrays for drug delivery and fluid extraction
-
24-27 July 2005. Washington, DC:IEEE Computer Society
-
Zhang P, Jullien G. Microneedle arrays for drug delivery and fluid extraction. Proceedings of International Conference on MEMS, NANO and Smart Systems, Banff, Canada, 24-27 July 2005. Washington, DC: IEEE Computer Society; 2005:392-395.
-
(2005)
Proceedings of International Conference on MEMS NANO and Smart Systems Banff Canada
, pp. 392-395
-
-
Zhang, P.1
Jullien, G.2
-
13
-
-
46149094849
-
Theoretical analytical flow model in hollow microneedles for non-forced fluid extraction
-
Zhuhai, China, 18-21 January 2006. New York, NY: IEEE
-
Liu R, Wang X, Feng Y, et al. Theoretical analytical flow model in hollow microneedles for non-forced fluid extraction. Proceedings of 1st IEEE International Conference on Nano/Micro Engineered and Molecular Systems, Zhuhai, China, 18-21 January 2006. New York, NY: IEEE; 2006:1039-1042.
-
(2006)
Proceedings of 1st IEEE International Conference on Nano/Micro Engineered and Molecular Systems
, pp. 1039-1042
-
-
Liu, R.1
Wang, X.2
Feng, Y.3
-
14
-
-
77951298688
-
Design and development of a biocompatible painless microneedle by the ion sputtering deposition method
-
Tsuchiya K, Jinnin S, Yamamoto H, et al. Design and development of a biocompatible painless microneedle by the ion sputtering deposition method. Precis Eng. 2010;34:461-466.
-
(2010)
Precis Eng
, vol.34
, pp. 461-466
-
-
Tsuchiya, K.1
Jinnin, S.2
Yamamoto, H.3
-
15
-
-
0035501453
-
A sampling mechanism employing the phase transition of a gel and its application to a micro analysis system imitating a mosquito
-
Kobayashi K, Suzuki H. A sampling mechanism employing the phase transition of a gel and its application to a micro analysis system imitating a mosquito. Sens Actuators B Chem. 2001;80:1-8.
-
(2001)
Sens Actuators B Chem
, vol.80
, pp. 1-8
-
-
Kobayashi, K.1
Suzuki, H.2
-
16
-
-
0037086387
-
Intelligent mosquito with a reversible sampling mechanism using the volume-phase transition of a gel
-
Suzuki H, Tokuda T, Kobayashi K. A disposable "intelligent mosquito" with a reversible sampling mechanism using the volume-phase transition of a gel. Sens Actuators B Chem. 2002;83:53-59.
-
(2002)
Sens Actuators B Chem
, vol.83
, pp. 53-59
-
-
Suzuki, H.1
Tokuda, T.2
Disposable A, K.K.3
-
17
-
-
0348170846
-
A disposable on-line microsystem for continuous sampling and monitoring of glucose
-
Suzuki H, Tokuda T, Miyagishi T, et al. A disposable on-line microsystem for continuous sampling and monitoring of glucose. Sens Actuators B Chem. 2004;97:90-97.
-
(2004)
Sens Actuators B Chem
, vol.97
, pp. 90-97
-
-
Suzuki, H.1
Tokuda, T.2
Miyagishi, T.3
-
19
-
-
77954833963
-
Mosquito proboscis: An elegant biomicroelectromechanical system
-
Kong XQ, Wu CW. Mosquito proboscis: an elegant biomicroelectromechanical system. Phys Rev E Stat Nonlin Soft Matter Phys. 2010;82:011910.
-
(2010)
Phys Rev e Stat Nonlin Soft Matter Phys
, vol.82
, pp. 011910
-
-
Kong, X.Q.1
Wu, C.W.2
-
20
-
-
0036544241
-
Fabrication of a micro needle for a trace blood test
-
Oka K, Aoyagi S, Arai Y, et al. Fabrication of a micro needle for a trace blood test. Sens Actuators A Phys. 2002;97-98:478-485.
-
(2002)
Sens Actuators A Phys
, vol.97-98
, pp. 478-485
-
-
Oka, K.1
Aoyagi, S.2
Arai, Y.3
-
21
-
-
6344235394
-
Quadruplets-microneedle array for blood extraction
-
Boston MA 7-11 March 2004. Cambridge, United Kingdom: Nano Science Technology Inst
-
Khumpuang S, Kawaguchi G, Sugiyama S. Quadruplets-microneedle array for blood extraction. Proceedings of the Nanotechnology Conference and Trade Show, Boston, MA, 7-11 March 2004. Cambridge, United Kingdom: Nano Science Technology Inst; 2004;1:205-208.
-
(2004)
Proceedings of the Nanotechnology Conference and Trade Show
, vol.1
, pp. 205-208
-
-
Khumpuang, S.1
Kawaguchi, G.2
Sugiyama, S.3
-
22
-
-
14844356007
-
Minimally invasive extraction of dermal interstitial fluid for glucose monitoring using microneedles
-
Wang P, Cornwell M, Prausnitz M. Minimally invasive extraction of dermal interstitial fluid for glucose monitoring using microneedles. Diabetes Technol Ther. 2005;7:131-141.
-
(2005)
Diabetes Technol Ther
, vol.7
, pp. 131-141
-
-
Wang, P.1
Cornwell, M.2
Prausnitz, M.3
-
24
-
-
14844346546
-
Electroosmosis in transdermal iontophoresis: Implications for noninvasive and calibration-free glucose monitoring
-
Sieg A, Guy R, Delgado-Charro M. Electroosmosis in transdermal iontophoresis: implications for noninvasive and calibration-free glucose monitoring. Biophys J. 2004;87:3344-3350.
-
(2004)
Biophys J
, vol.87
, pp. 3344-3350
-
-
Sieg, A.1
Guy, R.2
Delgado-Charro, M.3
-
25
-
-
33645279007
-
Assessment of trueness of a glucose monitor using interstitial fluid and whole blood as specimen matrix
-
Vesper H, Wang P, Archibold E, et al. Assessment of trueness of a glucose monitor using interstitial fluid and whole blood as specimen matrix. Diabetes Technol Ther. 2006;8:76-80.
-
(2006)
Diabetes Technol Ther
, vol.8
, pp. 76-80
-
-
Vesper, H.1
Wang, P.2
Archibold, E.3
-
26
-
-
82455204633
-
Measurement of glucose area under the curve using minimally invasive interstitial fluid extraction technology: Evaluation of glucose monitoring concepts without blood sampling
-
Sato T, Okada S, Hagino K, et al. Measurement of glucose area under the curve using minimally invasive interstitial fluid extraction technology: evaluation of glucose monitoring concepts without blood sampling. Diabetes Technol Ther. 2011;13:1194-1200.
-
(2011)
Diabetes Technol Ther.
, vol.13
, pp. 1194-1200
-
-
Sato, T.1
Okada, S.2
Hagino, K.3
-
27
-
-
84861981234
-
A minimally invasive system for glucose area under the curve measurement using interstitial fluid extraction technology: Evaluation of the accuracy and usefulness with oral glucose tolerance tests in subjects with and without diabetes
-
Sakaguchi K, Hirota Y, Hashimoto N, et al. A minimally invasive system for glucose area under the curve measurement using interstitial fluid extraction technology: evaluation of the accuracy and usefulness with oral glucose tolerance tests in subjects with and without diabetes. Diabetes Technol Ther. 2012;14:485-491.
-
(2012)
Diabetes Technol Ther
, vol.14
, pp. 485-491
-
-
Sakaguchi, K.1
Hirota, Y.2
Hashimoto, N.3
-
29
-
-
84899837398
-
A novel microneedle array integrated with a PDMS biochip for microfluid systems
-
Boston MA 8-12 June 2003. New York, NY: IEEE
-
Paik S, Lim J, Jung I, et al. A novel microneedle array integrated with a PDMS biochip for microfluid systems. Proceedings of the 12th International Conference on Solid-State Sensors, Actuators and Microsystems, Boston, MA, 8-12 June 2003. New York, NY: IEEE; 2003;2:1446-1449.
-
(2003)
Proceedings of the 12th International Conference on Solid-State Sensors Actuators and Microsystems
, vol.2
, pp. 1446-1449
-
-
Paik, S.1
Lim, J.2
Jung, I.3
-
30
-
-
4344679112
-
In-plane single-crystal-silicon microneedles for minimally invasive microfluid systems
-
Paik S, Byun A, Lim J, et al. In-plane single-crystal-silicon microneedles for minimally invasive microfluid systems. Sens Actuators A Phys. 2004; 114:276-284.
-
(2004)
Sens Actuators A Phys
, vol.114
, pp. 276-284
-
-
Paik, S.1
Byun, A.2
Lim, J.3
-
32
-
-
77649235080
-
Structural and microfluidic analysis of hollow side-open polymeric microneedles for transdermal drug delivery applications
-
Bodhale DW, Nisar A, Afzulpurkar N. Structural and microfluidic analysis of hollow side-open polymeric microneedles for transdermal drug delivery applications. Microfluid Nanofluidics. 2010;8:373-392.
-
(2010)
Microfluid Nanofluidics
, vol.8
, pp. 373-392
-
-
Bodhale, D.W.1
Nisar, A.2
Afzulpurkar, N.3
-
33
-
-
84892921019
-
Sampling for point-of-care analysis of lithium in whole blood with chip based CE
-
Vrouwe E, Luttge R. Sampling for point-of-care analysis of lithium in whole blood with chip based CE. Special Publication-RSC. 2005;296:503-505.
-
(2005)
Special Publication-RSC
, vol.296
, pp. 503-505
-
-
Vrouwe, E.1
Luttge, R.2
-
34
-
-
27544490323
-
An in-plane microneedles used for sampling and glucose analysis
-
Seoul Korea 5-9 June 2005. New York, NY: IEEE
-
Liu R, Wang X, Tang F, et al. An in-plane microneedles used for sampling and glucose analysis. Proceedings of 13th International on Solid-State Sensors, Actuators and Microsystems, Seoul, Korea, 5-9 June 2005. New York, NY: IEEE; 2005;2:1517-1520.
-
(2005)
Proceedings of 13th International on Solid-State Sensors Actuators and Microsystems
, vol.2
, pp. 1517-1520
-
-
Liu, R.1
Wang, X.2
Tang, F.3
-
35
-
-
35348842626
-
Electrochemical biosensors and microfluidics in organic system-on-package technology
-
Reno, NV, 29 May-1 June 2007 New York, NY: IEEE
-
Goud J, Raj PM, Liu J, et al. Electrochemical biosensors and microfluidics in organic system-on-package technology. Proceedings of 57th Electronic Components and Technology Conference, Reno, NV, 29 May-1 June 2007. New York, NY: IEEE; 2007:1550-1555.
-
(2007)
Proceedings of 57th Electronic Components and Technology Conference
, pp. 1550-1555
-
-
Goud, J.1
Raj, P.M.2
Liu, J.3
-
36
-
-
84885514736
-
Autonomous microneedle system for biochemical analysis
-
Boston MA 8-12 June 2003. New York, NY: IEEE
-
Chandrasekaran S, Mohanty S, Frazier A. Autonomous microneedle system for biochemical analysis. Proceedings of 12th International Conference on Solid-State Sensors, Actuators and Microsystems, Boston, MA, 8-12 June 2003. New York, NY: IEEE; 2003;2:1442-1445.
-
(2003)
Proceedings of 12th International Conference on Solid-State Sensors Actuators and Microsystems
, vol.2
, pp. 1442-1445
-
-
Chandrasekaran, S.1
Mohanty, S.2
Frazier, A.3
-
37
-
-
77957675472
-
Surface-modified microprojection arrays for intradermal biomarker capture, with low non-specific protein binding
-
Corrie S, Fernando G, Crichton M, et al. Surface-modified microprojection arrays for intradermal biomarker capture, with low non-specific protein binding. Lap Chip. 2010;10:2655-2658.
-
(2010)
Lap Chip
, vol.10
, pp. 2655-2658
-
-
Corrie, S.1
Fernando, G.2
Crichton, M.3
-
38
-
-
79954516154
-
Microneedle array-based carbon paste amperometric sensors and biosensors
-
Windmiller J, Zhou N, Chuang M, et al. Microneedle array-based carbon paste amperometric sensors and biosensors. Analyst. 2011;136:1846-1851.
-
(2011)
Analyst
, vol.136
, pp. 1846-1851
-
-
Windmiller, J.1
Zhou, N.2
Chuang, M.3
-
39
-
-
80053931169
-
Bicomponent microneedle array biosensor for minimally-invasive glutamate monitoring
-
Windmiller J, Valdes Ramirez G, Zhou N, et al. Bicomponent microneedle array biosensor for minimally-invasive glutamate monitoring. Electroanalysis. 2011;23:2302-2309.
-
(2011)
Electroanalysis
, vol.23
, pp. 2302-2309
-
-
Windmiller, J.1
Valdes Ramirez, G.2
Zhou, N.3
-
40
-
-
84055172791
-
Microfluidic device to investigate factors affecting performance in biosensors designed for transdermal applications
-
Trzebinski J, Sharma S, Moniz A, et al. Microfluidic device to investigate factors affecting performance in biosensors designed for transdermal applications. Lab Chip. 2012;12:348-352.
-
(2012)
Lab Chip
, vol.12
, pp. 348-352
-
-
Trzebinski, J.1
Sharma, S.2
Moniz, A.3
-
41
-
-
63649096039
-
High-integrated microvalve for Lab-onchip biomedical applications
-
Baltimore MD 20-22 November 2008, New York, NY: IEEE
-
Moreno M, Aracil C, Quero J. High-integrated microvalve for Lab-onchip biomedical applications. Proceedings of Biomedical Circuits and Systems Conference, Baltimore, MD, 20-22 November 2008, New York, NY: IEEE; 2008:313-316.
-
(2008)
Proceedings of Biomedical Circuits and Systems Conference
, pp. 313-316
-
-
Moreno, M.1
Aracil, C.2
Quero, J.3
-
42
-
-
64949154384
-
Low cost fluid microextractor for lab-onchip
-
Spain 11-13 February 2009. New York, NY: IEEE
-
Moreno M, Aracil JC, Quero J. Low cost fluid microextractor for lab-onchip. Proceedings of Spanish Conference on Electron Devices, Santiago de Compostela, Spain, 11-13 February 2009. New York, NY: IEEE; 2009:274-277.
-
(2009)
Proceedings of Spanish Conference on Electron Devices Santiago de Compostela
, pp. 274-277
-
-
Moreno, M.1
Aracil, J.C.2
Quero, J.3
-
43
-
-
84952671779
-
Microfabricated microdialysis microneedles for continuous medical monitoring
-
Lyon France 12-14 October 2000. New York, NY: IEEE
-
Zahn J, Trebotich D, Liepmann D. Microfabricated microdialysis microneedles for continuous medical monitoring. Proceedings of 1st Annual International Conference on Microtechnologies in Medicine and Biology, Lyon, France, 12-14 October 2000. New York, NY: IEEE; 2000:375-380.
-
(2000)
Proceedings of 1st Annual International Conference on Microtechnologies in Medicine and Biology
, pp. 375-380
-
-
Zahn, J.1
Trebotich, D.2
Liepmann, D.3
-
44
-
-
4243108935
-
A microneedle-based glucose monitor: Fabricated on a wafer-level using in-device enzyme immobilization
-
Boston MA 8-12 June 2003. New York, NY: IEEE
-
Zimmermann S, Fienbork D, Stoeber B, et al. A microneedle-based glucose monitor: fabricated on a wafer-level using in-device enzyme immobilization. Proceedings of 12th International Conference on Solid-State Sensors, Actuators and Microsystems, Boston, MA, 8-12 June 2003. New York, NY: IEEE; 2003:99-102.
-
(2003)
Proceedings of 12th International Conference on Solid-State Sensors Actuators and Microsystems
, pp. 99-102
-
-
Zimmermann, S.1
Fienbork, D.2
Stoeber, B.3
-
45
-
-
18144406839
-
Microdialysis microneedles for continuous medical monitoring
-
Zahn J, Trebotich D, Liepmann D. Microdialysis microneedles for continuous medical monitoring. Biomed Microdevices. 2005;7:59-69.
-
(2005)
Biomed Microdevices
, vol.7
, pp. 59-69
-
-
Zahn, J.1
Trebotich, D.2
Liepmann, D.3
-
47
-
-
84855911409
-
Multiplexed microneedle-based biosensor array for characterization of metabolic acidosis
-
Miller PR, Skoog SA, Edwards TL, et al. Multiplexed microneedle-based biosensor array for characterization of metabolic acidosis. Talanta. 2012; 88:739-742.
-
(2012)
Talanta
, vol.88
, pp. 739-742
-
-
Miller, P.R.1
Skoog, S.A.2
Edwards, T.L.3
-
48
-
-
84887775612
-
Simulation and fabrication of blood filtration system for patients with kidney diseases
-
Tayyaba S, Ashraf M, Afzulpurkar N. Simulation and fabrication of blood filtration system for patients with kidney diseases. IET Communications. 2012;6:3213-3221.
-
(2012)
IET Communications
, vol.6
, pp. 3213-3221
-
-
Tayyaba, S.1
Ashraf, M.2
Afzulpurkar, N.3
-
49
-
-
24944508964
-
Silicon microneedle electrode array with temperature monitoring for electroporation
-
Wilke N, Morrissey A, Hibert C, et al. Silicon microneedle electrode array with temperature monitoring for electroporation. Sens Actuators A Phys. 2005;123-124:319-325.
-
(2005)
Sens Actuators A Phys
, vol.123-124
, pp. 319-325
-
-
Wilke, N.1
Morrissey, A.2
Hibert, C.3
-
50
-
-
84859363537
-
High density and high aspect ratio solid micro-nanoprojection arrays for targeted skin vaccine delivery and specific antibody extraction
-
Jenkins D, Corrie S, Flaim C, et al. High density and high aspect ratio solid micro-nanoprojection arrays for targeted skin vaccine delivery and specific antibody extraction. RSC Adv. 2012;2:3490-3495.
-
(2012)
RSC Adv
, vol.2
, pp. 3490-3495
-
-
Jenkins, D.1
Corrie, S.2
Flaim, C.3
-
51
-
-
84859410902
-
Surface modified microprojection arrays for the selective extraction of the dengue virus NS1 protein as a marker for disease
-
Muller DA, Corrie SR, Coffey J, et al. Surface modified microprojection arrays for the selective extraction of the dengue virus NS1 protein as a marker for disease. Anal Chem. 2012;84:3262-3268.
-
(2012)
Anal Chem
, vol.84
, pp. 3262-3268
-
-
Muller, D.A.1
Corrie, S.R.2
Coffey, J.3
-
52
-
-
84861445017
-
Surface modifications of microprojection arrays for improved biomarker capture in the skin of live mice
-
Bhargav A, Muller DA, Kendall MA, et al. Surface modifications of microprojection arrays for improved biomarker capture in the skin of live mice. ACS Appl Mater Interfaces. 2012;4:2483-2489.
-
(2012)
ACS Appl Mater Interfaces
, vol.4
, pp. 2483-2489
-
-
Bhargav, A.1
Muller, D.A.2
Kendall, M.A.3
-
53
-
-
84871757901
-
Microneedle biosensor: A method for direct label-free real time protein detection
-
Esfandyarpour R, Esfandyarpour H, Javanmard M, et al. Microneedle biosensor: a method for direct label-free real time protein detection. Sens Actuators B Chem. 2013;177:848-855.
-
(2013)
Sens Actuators B Chem
, vol.177
, pp. 848-855
-
-
Esfandyarpour, R.1
Esfandyarpour, H.2
Javanmard, M.3
-
54
-
-
84870624248
-
Hydrogel-forming microneedle arrays for enhanced transdermal drug delivery
-
Donnelly RF, Thakur RRS, Garland MJ, et al. Hydrogel-forming microneedle arrays for enhanced transdermal drug delivery. Adv Funct Mater. 2012;22:4879-4890.
-
(2012)
Adv Funct Mater
, vol.22
, pp. 4879-4890
-
-
Donnelly, R.F.1
Thakur, R.R.S.2
Garland, M.J.3
|