-
1
-
-
70350710475
-
A robotic system for 18F-FMISO PET-guided intratumoral pO2 measurements
-
Chang J, Wen B, Kazanzides P et al. A robotic system for 18F-FMISO PET-guided intratumoral pO2 measurements. Med Phys 2009;36:5301-9.
-
(2009)
Med Phys
, vol.36
, pp. 5301-5309
-
-
Chang, J.1
Wen, B.2
Kazanzides, P.3
-
2
-
-
0035698467
-
Measuring hypoxia in solid tumours-is there a gold standard?
-
Olive PL, Banath JP, Aquino-Parsons C. Measuring hypoxia in solid tumours-is there a gold standard? Acta Oncol 2001;40:917-23.
-
(2001)
Acta Oncol
, vol.40
, pp. 917-923
-
-
Olive, P.L.1
Banath, J.P.2
Aquino-Parsons, C.3
-
3
-
-
0033022176
-
Influence of the hypoxic subvolume on the survival of patients with head and neck cancer
-
Stadler P, Becker A, Feldmann HJ et al. Influence of the hypoxic subvolume on the survival of patients with head and neck cancer. Int J Radiat Oncol Biol Phys 1999;44:749-54.
-
(1999)
Int J Radiat Oncol Biol Phys
, vol.44
, pp. 749-754
-
-
Stadler, P.1
Becker, A.2
Feldmann, H.J.3
-
4
-
-
0031716020
-
Oxygenation predicts radiation response and survival in patients with cervix cancer
-
Fyles AW, Milosevic M, Wong R et al. Oxygenation predicts radiation response and survival in patients with cervix cancer. Radiother Oncol 1998;48:149-56.
-
(1998)
Radiother Oncol
, vol.48
, pp. 149-156
-
-
Fyles, A.W.1
Milosevic, M.2
Wong, R.3
-
5
-
-
0035989255
-
Brain tissue PO2: Correlation with cerebral blood flow
-
Valadka AB, Hlatky R, Furuya Y et al. Brain tissue PO2: correlation with cerebral blood flow. Acta Neurochir Suppl 2002;81:299-301.
-
(2002)
Acta Neurochir Suppl
, vol.81
, pp. 299-301
-
-
Valadka, A.B.1
Hlatky, R.2
Furuya, Y.3
-
6
-
-
0032905752
-
Blood flow and oxygenation status of human tumors. Clinical investigations
-
Feldmann HJ, Molls M, Vaupel P. Blood flow and oxygenation status of human tumors. Clinical investigations. Strahlenther Onkol 1999;175:1-9.
-
(1999)
Strahlenther Onkol
, vol.175
, pp. 1-9
-
-
Feldmann, H.J.1
Molls, M.2
Vaupel, P.3
-
7
-
-
0033660229
-
Pixel analysis of MR perfusion imaging in prediction radiation therapy outcome in cervical cancer
-
Mayr NA, Yuh WT, Arnholt JC et al. Pixel analysis of MR perfusion imaging in prediction radiation therapy outcome in cervical cancer. J Magn Reson Imaging 2000;12:1027-33.
-
(2000)
J Magn Reson Imaging
, vol.12
, pp. 1027-1033
-
-
Mayr, N.A.1
Yuh, W.T.2
Arnholt, J.C.3
-
8
-
-
0038376251
-
Linking radiation oncology and imaging through molecular biology (or now that therapy and diagnosis have separated, it's time to get together again!)
-
Coleman CN. Linking radiation oncology and imaging through molecular biology (or now that therapy and diagnosis have separated, it's time to get together again!). Radiology 2003;228:29-35.
-
(2003)
Radiology
, vol.228
, pp. 29-35
-
-
Coleman, C.N.1
-
10
-
-
0037650168
-
Perfusion CT: A worthwhile enhancement
-
Miles KA, Griffiths MR. Perfusion CT: a worthwhile enhancement. Br J Radiol 2003;76:220-31.
-
(2003)
Br J Radiol
, vol.76
, pp. 220-231
-
-
Miles, K.A.1
Griffiths, M.R.2
-
11
-
-
0033778716
-
Application of CT in the investigation of angiogenesis in oncology
-
Miles KA, Charnsangavej C, Lee FT et al. Application of CT in the investigation of angiogenesis in oncology. Acad Radiol 2000;7:840-50.
-
(2000)
Acad Radiol
, vol.7
, pp. 840-850
-
-
Miles, K.A.1
Charnsangavej, C.2
Lee, F.T.3
-
12
-
-
0036519221
-
Special techniques for imaging blood flow to tumors
-
Choyke PL, Knopp MV, Libutti SK. Special techniques for imaging blood flow to tumors. Cancer J 2002;8:109-18.
-
(2002)
Cancer J
, vol.8
, pp. 109-118
-
-
Choyke, P.L.1
Knopp, M.V.2
Libutti, S.K.3
-
13
-
-
0035739245
-
Functional CT imaging of angiogenesis in rabbit VX2 soft-tissue tumour
-
Purdie TG, Henderson E, Lee TY. Functional CT imaging of angiogenesis in rabbit VX2 soft-tissue tumour. Phys Med Biol 2001;46:3161-75.
-
(2001)
Phys Med Biol
, vol.46
, pp. 3161-3175
-
-
Purdie, T.G.1
Henderson, E.2
Lee, T.Y.3
-
14
-
-
54049103972
-
Functional computed tomo-graphic quantification of angiogenesis in rabbit VX2 soft-tissue tumor before and after interventional therapy
-
Zhang J, Wang R, Lou H et al. Functional computed tomo-graphic quantification of angiogenesis in rabbit VX2 soft-tissue tumor before and after interventional therapy. J Comp Assis Tomogr 2008;32:697-705.
-
(2008)
J Comp Assis Tomogr
, vol.32
, pp. 697-705
-
-
Zhang, J.1
Wang, R.2
Lou, H.3
-
15
-
-
84863468769
-
Comparison of 64-slice CT perfu-sion imaging with contrast-enhanced CT for evaluating the target volume for three-dimensional conformal radiotherapy in the rabbit VX2 brain tumor model
-
Sun C-J, Li C, Yu J-M et al. Comparison of 64-slice CT perfu-sion imaging with contrast-enhanced CT for evaluating the target volume for three-dimensional conformal radiotherapy in the rabbit VX2 brain tumor model. J Radiat Res 2012;53: 454-61.
-
(2012)
J Radiat Res
, vol.53
, pp. 454-461
-
-
Sun, C.-J.1
Li, C.2
Yu, J.-M.3
-
16
-
-
0025980839
-
Colour perfusion imaging: A new application of computed tomography
-
Miles KA, Hayball M, Dixon AK. Colour perfusion imaging: a new application of computed tomography. Lancet 1991;337:643-5.
-
(1991)
Lancet
, vol.337
, pp. 643-645
-
-
Miles, K.A.1
Hayball, M.2
Dixon, A.K.3
-
17
-
-
0027226363
-
Functional images of hepatic perfusion obtained with dynamic CT
-
Miles KA, Hayball MP, Dixon AK. Functional images of hepatic perfusion obtained with dynamic CT. Radiology 1993;188:405-11.
-
(1993)
Radiology
, vol.188
, pp. 405-411
-
-
Miles, K.A.1
Hayball, M.P.2
Dixon, A.K.3
-
18
-
-
82055182251
-
Blood flow change quantification in cervical cancer before and during radiation therapy using perfusion CT
-
Shibuya K, Tsushima Y, Horisoko E et al. Blood flow change quantification in cervical cancer before and during radiation therapy using perfusion CT. J Radiat Res 2011;52:804-11.
-
(2011)
J Radiat Res
, vol.52
, pp. 804-811
-
-
Shibuya, K.1
Tsushima, Y.2
Horisoko, E.3
-
19
-
-
70249150678
-
Comparing oxygen-sensitive MRI (BOLD R2*) with oxygen electrode measurements: A pilot study in men with prostate cancer
-
Chopra S, Foltz WD, Milosevic MF et al. Comparing oxygen-sensitive MRI (BOLD R2*) with oxygen electrode measurements: a pilot study in men with prostate cancer. Int J Radiat Biol 2009;85:805-13.
-
(2009)
Int J Radiat Biol
, vol.85
, pp. 805-813
-
-
Chopra, S.1
Foltz, W.D.2
Milosevic, M.F.3
-
20
-
-
29344443755
-
Relationship between brain tissue oxygen tension and CT perfusion: Feasibility and initial results
-
Hemphill JC, 3rd, Smith WS, Sonne DC et al. Relationship between brain tissue oxygen tension and CT perfusion: feasibility and initial results. AJNR Am J Neuroradiol 2005;26:1095-100.
-
(2005)
AJNR Am J Neuroradiol
, vol.26
, pp. 1095-1100
-
-
Hemphill III, J.C.1
Smith, W.S.2
Sonne, D.C.3
-
21
-
-
77955497821
-
Noninvasive assessment of tumor micro-environment using dynamic contrast-enhanced magnetic resonance imaging and 18F-fluoromisonidazole positron emission tomography imaging in neck nodal metasta-ses
-
Jansen JF, Schöder H, Lee NY et al. Noninvasive assessment of tumor micro-environment using dynamic contrast-enhanced magnetic resonance imaging and 18F-fluoromisonidazole positron emission tomography imaging in neck nodal metasta-ses. Int J Radiat Oncol Biol Phys 2010;77:1403-10.
-
(2010)
Int J Radiat Oncol Biol Phys
, vol.77
, pp. 1403-1410
-
-
Jansen, J.F.1
Schöder, H.2
Lee, N.Y.3
-
22
-
-
70249141560
-
Dynamic CT angiog-raphy and CT perfusion employing a 320-detector row CT: Protocol and current clinical applications
-
Salomon EJ, Barfett J, Willems PW et al. Dynamic CT angiog-raphy and CT perfusion employing a 320-detector row CT: protocol and current clinical applications. Klin Neuroradiol 2009;19:187-96.
-
(2009)
Klin Neuroradiol
, vol.19
, pp. 187-196
-
-
Salomon, E.J.1
Barfett, J.2
Willems, P.W.3
-
23
-
-
16244399521
-
Tumor oxygenation status as a prognostic marker
-
Menon C, Fraker DL. Tumor oxygenation status as a prognostic marker. Cancer Lett 2005;221:225-35.
-
(2005)
Cancer Lett
, vol.221
, pp. 225-235
-
-
Menon, C.1
Fraker, D.L.2
|