메뉴 건너뛰기




Volumn 76, Issue 904, 2003, Pages 220-231

Perfusion CT: A worthwhile enhancement?

Author keywords

[No Author keywords available]

Indexed keywords

ANTINEOPLASTIC AGENT; FIBRINOLYTIC AGENT; IODINATED CONTRAST MEDIUM; TRACER;

EID: 0037650168     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/bjr/13564625     Document Type: Review
Times cited : (384)

References (85)
  • 1
    • 0019163790 scopus 로고
    • Cerebral blood flow determination by rapid-sequence computed tomography: Theoretical analysis
    • Axel L. Cerebral blood flow determination by rapid-sequence computed tomography: Theoretical analysis. Radiology 1980;137:679-86.
    • (1980) Radiology , vol.137 , pp. 679-686
    • Axel, L.1
  • 3
    • 84970742853 scopus 로고
    • Cine-computed tomographic assessment of regional renal blood flow
    • Jaschke W, Sievers RS, Lipton MJ, Cogan MG. Cine-computed tomographic assessment of regional renal blood flow. Acta Radiol 1990;31:77-81.
    • (1990) Acta Radiol , vol.31 , pp. 77-81
    • Jaschke, W.1    Sievers, R.S.2    Lipton, M.J.3    Cogan, M.G.4
  • 4
    • 0025980839 scopus 로고
    • Colour perfusion imaging: A new application of computed tomography
    • Miles KA, Hayball M, Dixon AK. Colour perfusion imaging: A new application of computed tomography. Lancet 1991;337:643-5.
    • (1991) Lancet , vol.337 , pp. 643-645
    • Miles, K.A.1    Hayball, M.2    Dixon, A.K.3
  • 5
    • 0027226363 scopus 로고
    • Functional images of hepatic perfusion obtained with dynamic CT
    • Miles KA, Hayball MP, Dixon AK. Functional images of hepatic perfusion obtained with dynamic CT. Radiology 1993;188:405-11.
    • (1993) Radiology , vol.188 , pp. 405-411
    • Miles, K.A.1    Hayball, M.P.2    Dixon, A.K.3
  • 6
    • 0034913780 scopus 로고    scopus 로고
    • Standardized perfusion value: Universal CT contrast enhancement scale that correlates with FDG PET in lung nodules
    • Miles KA, Griffiths MR, Fuentes MA. Standardized perfusion value: Universal CT contrast enhancement scale that correlates with FDG PET in lung nodules. Radiology 2001;220:548-53.
    • (2001) Radiology , vol.220 , pp. 548-553
    • Miles, K.A.1    Griffiths, M.R.2    Fuentes, M.A.3
  • 8
    • 0000392781 scopus 로고    scopus 로고
    • Antiangiogenic treatment with endostatin results in uncoupling of blood flow and glucose metabolism in human tumors
    • Mullani N, Herbst R, Abbruzzese J, Charnsangavej C, Kim E, Tran H, et al. Antiangiogenic treatment with endostatin results in uncoupling of blood flow and glucose metabolism in human tumors. Clin Positron Imaging 2000;3:151.
    • (2000) Clin Positron Imaging , vol.3 , pp. 151
    • Mullani, N.1    Herbst, R.2    Abbruzzese, J.3    Charnsangavej, C.4    Kim, E.5    Tran, H.6
  • 9
    • 0036197311 scopus 로고    scopus 로고
    • Evaluation of the anti-vascular effects of combretastatin in rodent tumours by dynamic contrast enhanced MRI
    • Maxwell RJ, Wilson J, Prise VE, Vojnovic B, Rustin GJ, Lodge MA, et al. Evaluation of the anti-vascular effects of combretastatin in rodent tumours by dynamic contrast enhanced MRI. NMR Biomed 2002;15:89-98.
    • (2002) NMR Biomed , vol.15 , pp. 89-98
    • Maxwell, R.J.1    Wilson, J.2    Prise, V.E.3    Vojnovic, B.4    Rustin, G.J.5    Lodge, M.A.6
  • 10
    • 0028783948 scopus 로고
    • Tissue plasminogen activator for acute ischemic stroke. The National Institute of Neurological Disorders and Stroke rtPA Stroke Study Group
    • Tissue plasminogen activator for acute ischemic stroke. The National Institute of Neurological Disorders and Stroke rtPA Stroke Study Group. N Engl J Med 1995;333:1581-7.
    • (1995) N Engl J Med , vol.333 , pp. 1581-1587
  • 11
    • 0032541845 scopus 로고    scopus 로고
    • Randomised double-blind placebo-controlled trial of thrombolytic therapy with intravenous alteplase in acute ischaemic stroke (ECASS II). Second European-Australasian Acute Stroke Study Investigators
    • Hacke W, Kaste M, Fieschi C, Von Kummer R, Davalos A, Meier D, et al. Randomised double-blind placebo-controlled trial of thrombolytic therapy with intravenous alteplase in acute ischaemic stroke (ECASS II). Second European-Australasian Acute Stroke Study Investigators. Lancet 1998;352:1245-51.
    • (1998) Lancet , vol.352 , pp. 1245-1251
    • Hacke, W.1    Kaste, M.2    Fieschi, C.3    Von Kummer, R.4    Davalos, A.5    Meier, D.6
  • 12
    • 0035137614 scopus 로고    scopus 로고
    • Quantitative assessment of the ischemic brain by means of perfusion-related parameters derived from perfusion CT
    • Koenig M, Kraus M, Theek C, Klotz E, Gehlen W, Heuser L. Quantitative assessment of the ischemic brain by means of perfusion-related parameters derived from perfusion CT. Stroke 2001;32:431-7.
    • (2001) Stroke , vol.32 , pp. 431-437
    • Koenig, M.1    Kraus, M.2    Theek, C.3    Klotz, E.4    Gehlen, W.5    Heuser, L.6
  • 14
    • 0344417098 scopus 로고    scopus 로고
    • Perfusion measurements of the brain: Using dynamic CT for the quantitative assessment of cerebral ischemia in acute stroke
    • Klotz E, König M. Perfusion measurements of the brain: Using dynamic CT for the quantitative assessment of cerebral ischemia in acute stroke. Eur J Radiol 1999;30:170-84.
    • (1999) Eur J Radiol , vol.30 , pp. 170-184
    • Klotz, E.1    König, M.2
  • 15
    • 0036200242 scopus 로고    scopus 로고
    • Prognostic accuracy of cerebral blood flow measurement by perfusion computed tomography, at the time of emergency room admission, in acute stroke patients
    • Wintermark M, Reichhart M, Thiran JP, Maeder P, Chalaron M, Schnyder P, et al. Prognostic accuracy of cerebral blood flow measurement by perfusion computed tomography, at the time of emergency room admission, in acute stroke patients. Ann Neurol 2002;51:417-32.
    • (2002) Ann Neurol , vol.51 , pp. 417-432
    • Wintermark, M.1    Reichhart, M.2    Thiran, J.P.3    Maeder, P.4    Chalaron, M.5    Schnyder, P.6
  • 16
    • 0028158669 scopus 로고
    • Predictors of pathologic stage in prostatic carcinoma. The role of neovascularity
    • Brawer MK, Deering RE, Brown M, Preston SD, Bigler SA. Predictors of pathologic stage in prostatic carcinoma. The role of neovascularity. Cancer 1994;73:678-87.
    • (1994) Cancer , vol.73 , pp. 678-687
    • Brawer, M.K.1    Deering, R.E.2    Brown, M.3    Preston, S.D.4    Bigler, S.A.5
  • 17
    • 0030996171 scopus 로고    scopus 로고
    • Angiogenesis as a prognostic indicator of survival in non-small cell lung carcinoma: A prospective study
    • Fontanini G, Lucchi M, Vignati S, Mussi A, Ciardiello F, De Laurentiis M, et al. Angiogenesis as a prognostic indicator of survival in non-small cell lung carcinoma: A prospective study. J Natl Cancer Inst 1997;89:881-6.
    • (1997) J Natl Cancer Inst , vol.89 , pp. 881-886
    • Fontanini, G.1    Lucchi, M.2    Vignati, S.3    Mussi, A.4    Ciardiello, F.5    De Laurentiis, M.6
  • 21
    • 0034463690 scopus 로고    scopus 로고
    • Double-phase helical CT of small renal parenchymal neoplasms: Correlation with pathologic findings and tumor angiogenesis
    • Jinzaki M, Tanimoto A, Mukai M, Ikeda E, Kobayashi S, Yuasa Y, et al. Double-phase helical CT of small renal parenchymal neoplasms: Correlation with pathologic findings and tumor angiogenesis. J Comput Assist Tomogr 2000;24:835-42.
    • (2000) J Comput Assist Tomogr , vol.24 , pp. 835-842
    • Jinzaki, M.1    Tanimoto, A.2    Mukai, M.3    Ikeda, E.4    Kobayashi, S.5    Yuasa, Y.6
  • 22
    • 0032865983 scopus 로고    scopus 로고
    • Tumour angiogenesis and its relation to contrast enhancement of computed tomography: A review
    • Miles KA. Tumour angiogenesis and its relation to contrast enhancement of computed tomography: A review. Eur J Radiol 1999;30:198-205.
    • (1999) Eur J Radiol , vol.30 , pp. 198-205
    • Miles, K.A.1
  • 24
    • 0030685099 scopus 로고    scopus 로고
    • Solitary pulmonary nodules: Evaluation of blood flow patterns with dynamic CT
    • Zhang M, Kono M. Solitary pulmonary nodules: Evaluation of blood flow patterns with dynamic CT. Radiology 1997;205:471-8.
    • (1997) Radiology , vol.205 , pp. 471-478
    • Zhang, M.1    Kono, M.2
  • 25
    • 0028827326 scopus 로고
    • Lymph-node metastases: Efficacy for detection with helical CT in patients with gastric cancer
    • Fukuya T, Honda H, Hayashi T, Kaneko K, Tateshi Y, Ro T, et al. Lymph-node metastases: Efficacy for detection with helical CT in patients with gastric cancer. Radiology 1995;197:705-11.
    • (1995) Radiology , vol.197 , pp. 705-711
    • Fukuya, T.1    Honda, H.2    Hayashi, T.3    Kaneko, K.4    Tateshi, Y.5    Ro, T.6
  • 26
    • 0035144643 scopus 로고    scopus 로고
    • Early changes in liver perfusion caused by occult metastases in rats: Detection with quantitative CT
    • Cuenod C, Leconte I, Siauve N, Resten A, Dromain C, Poulet B, et al. Early changes in liver perfusion caused by occult metastases in rats: Detection with quantitative CT. Radiology 2001;218:556-61.
    • (2001) Radiology , vol.218 , pp. 556-561
    • Cuenod, C.1    Leconte, I.2    Siauve, N.3    Resten, A.4    Dromain, C.5    Poulet, B.6
  • 27
    • 0030850325 scopus 로고    scopus 로고
    • Liver metastases: Early detection based on abnormal contrast material enhancement at dual-phase helical CT
    • Platt JF, Francis IR, Ellis JH, Reige KA. Liver metastases: Early detection based on abnormal contrast material enhancement at dual-phase helical CT. Radiology 1997;205:49-53.
    • (1997) Radiology , vol.205 , pp. 49-53
    • Platt, J.F.1    Francis, I.R.2    Ellis, J.H.3    Reige, K.A.4
  • 28
    • 0034092480 scopus 로고    scopus 로고
    • Hepatic parenchymal enhancement during triplet-phase helical CT: Can it be used to predict which patients with breast cancer will develop hepatic metastases?
    • Sheafor DH, Killius JS, Paulson EK, DeLong DM, Foti AM, Nelson RC. Hepatic parenchymal enhancement during triplet-phase helical CT: Can it be used to predict which patients with breast cancer will develop hepatic metastases? Radiology 2000;214:875-80.
    • (2000) Radiology , vol.214 , pp. 875-880
    • Sheafor, D.H.1    Killius, J.S.2    Paulson, E.K.3    Delong, D.M.4    Foti, A.M.5    Nelson, R.C.6
  • 29
    • 0030698625 scopus 로고    scopus 로고
    • Colorectal cancer: Diagnostic potential of CT measurements of hepatic perfusion and implications for contrast enhancement protocols
    • Leggett DA, Kelley BB, Bunce IH, Miles KA. Colorectal cancer: Diagnostic potential of CT measurements of hepatic perfusion and implications for contrast enhancement protocols. Radiology 1997;205:716-20.
    • (1997) Radiology , vol.205 , pp. 716-720
    • Leggett, D.A.1    Kelley, B.B.2    Bunce, I.H.3    Miles, K.A.4
  • 30
    • 0032818193 scopus 로고    scopus 로고
    • Hepatic metastases: The value of quantitative assessment of contrast enhancement on computed tomography
    • Dugdale PE, Miles KA. Hepatic metastases: The value of quantitative assessment of contrast enhancement on computed tomography. Eur J Radiol 1999;30:206-13.
    • (1999) Eur J Radiol , vol.30 , pp. 206-213
    • Dugdale, P.E.1    Miles, K.A.2
  • 31
    • 0032767423 scopus 로고    scopus 로고
    • CT measurement of perfusion and permeability within lymphoma masses and its ability to assess grade, activity, and chemotherapeutic response
    • Dugdale PE, Miles KA, Bunce I, Kelley BB, Leggett DA. CT measurement of perfusion and permeability within lymphoma masses and its ability to assess grade, activity, and chemotherapeutic response. J Comput Assist Tomogr 1999;23:540-7.
    • (1999) J Comput Assist Tomogr , vol.23 , pp. 540-547
    • Dugdale, P.E.1    Miles, K.A.2    Bunce, I.3    Kelley, B.B.4    Leggett, D.A.5
  • 32
    • 0031769411 scopus 로고    scopus 로고
    • Blood-brain barrier and blood volume imaging of cerebral glioma using functional CT: A pictorial review
    • Leggett DA, Miles KA, Kelley BB. Blood-brain barrier and blood volume imaging of cerebral glioma using functional CT: A pictorial review. Australas Radiol 1998;42:335-40.
    • (1998) Australas Radiol , vol.42 , pp. 335-340
    • Leggett, D.A.1    Miles, K.A.2    Kelley, B.B.3
  • 33
    • 0034060928 scopus 로고    scopus 로고
    • Quantitative measurement of microvascular permeability in human brain tumours achieved using dynamic contrast-enhanced MR imaging: Correlation with histologic grade
    • Roberts HC, Roberts TP, Brasch RC, Dillon WP. Quantitative measurement of microvascular permeability in human brain tumours achieved using dynamic contrast-enhanced MR imaging: Correlation with histologic grade. Am J Neuroradiol 2000;21:891-9.
    • (2000) Am J Neuroradiol , vol.21 , pp. 891-899
    • Roberts, H.C.1    Roberts, T.P.2    Brasch, R.C.3    Dillon, W.P.4
  • 37
    • 0028276749 scopus 로고
    • Effect of steroids on iopamidol blood-brain transfer constant and plasma volume in brain tumors measured with X-ray computed tomography
    • Yeung WT, Lee TY, Del Maestro RF, Kozak R, Bennett J, Brown T. Effect of steroids on iopamidol blood-brain transfer constant and plasma volume in brain tumors measured with X-ray computed tomography. J Neurooncol 1994;18:53-60.
    • (1994) J Neurooncol , vol.18 , pp. 53-60
    • Yeung, W.T.1    Lee, T.Y.2    Del Maestro, R.F.3    Kozak, R.4    Bennett, J.5    Brown, T.6
  • 38
    • 0003118435 scopus 로고    scopus 로고
    • A simplified method for measurement of blood-brain barrier permeability using CT: Preliminary results and the effect of RMP-7
    • In: Faulkner K et al, editors.; London: British Institute of Radiology
    • Ford J, Miles K, Hayball M, Bearcroft P, Bleehan N, Osborn C. A simplified method for measurement of blood-brain barrier permeability using CT: Preliminary results and the effect of RMP-7. In: Faulkner K et al, editors. Quantitative Imaging in Oncology. London: British Institute of Radiology, 1-5.
    • Quantitative Imaging in Oncology , pp. 1-5
    • Ford, J.1    Miles, K.2    Hayball, M.3    Bearcroft, P.4    Bleehan, N.5    Osborn, C.6
  • 41
    • 0035143406 scopus 로고    scopus 로고
    • Functional CT imaging of the acute hyperemic response to radiation therapy of the prostate gland: Early experience
    • Harvey CJ, Blomley MJ, Dawson P, Morgan JA, Dooher A, Deponte J, et al. Functional CT imaging of the acute hyperemic response to radiation therapy of the prostate gland: Early experience. J Comput Assist Tomogr 2001;25:43-9.
    • (2001) J Comput Assist Tomogr , vol.25 , pp. 43-49
    • Harvey, C.J.1    Blomley, M.J.2    Dawson, P.3    Morgan, J.A.4    Dooher, A.5    Deponte, J.6
  • 42
    • 0033775313 scopus 로고    scopus 로고
    • Tumor angiogenesis: Molecular pathology, therapeutic targeting, and imaging
    • Li WW. Tumor angiogenesis: Molecular pathology, therapeutic targeting, and imaging. Acad Radiol 2000;7:800-11.
    • (2000) Acad Radiol , vol.7 , pp. 800-811
    • Li, W.W.1
  • 43
    • 0038165019 scopus 로고    scopus 로고
    • Applications of perfusion CT
    • Miles K, Dawson P, Blomley M, editors. Oxford ISIS Medical Media
    • Miles K, Blomley M. Applications of perfusion CT. Functional Computed Tomography. Miles K, Dawson P, Blomley M, editors. Oxford ISIS Medical Media, 89-116.
    • Functional Computed Tomography , pp. 89-116
    • Miles, K.1    Blomley, M.2
  • 44
    • 0035115565 scopus 로고    scopus 로고
    • Hepatic perfusion parameters in chronic liver disease: Dynamic CT measurements correlated with disease severity
    • Van Beers BE, Leconte I, Materne R, Smith AM, Jamart J, Horsmans Y. Hepatic perfusion parameters in chronic liver disease: Dynamic CT measurements correlated with disease severity. Am J Roentgenol 2001;176:667-73.
    • (2001) Am J Roentgenol , vol.176 , pp. 667-673
    • Van Beers, B.E.1    Leconte, I.2    Materne, R.3    Smith, A.M.4    Jamart, J.5    Horsmans, Y.6
  • 45
    • 0032870939 scopus 로고    scopus 로고
    • The portal component of hepatic perfusion measured by dynamic CT: An indicator of hepatic parenchymal damage
    • Tsushima Y, Blomley JK, Kusano S, Endo K. The portal component of hepatic perfusion measured by dynamic CT: An indicator of hepatic parenchymal damage. Dig Dis Sci 1999;44:1632-8.
    • (1999) Dig Dis Sci , vol.44 , pp. 1632-1638
    • Tsushima, Y.1    Blomley, J.K.2    Kusano, S.3    Endo, K.4
  • 46
    • 0031719025 scopus 로고    scopus 로고
    • Hepatic perfusion after liver transplantation: Noninvasive measurement with dynamic single-section CT
    • Bader TR, Herneth AM, Blaicher W, Steininger R, Muhlbacher F, Lechner G, et al. Hepatic perfusion after liver transplantation: Noninvasive measurement with dynamic single-section CT. Radiology 1998;209:129-34.
    • (1998) Radiology , vol.209 , pp. 129-134
    • Bader, T.R.1    Herneth, A.M.2    Blaicher, W.3    Steininger, R.4    Muhlbacher, F.5    Lechner, G.6
  • 47
    • 0028959059 scopus 로고
    • Transient splenic inhomogeneity with contrast-enhanced CT: Mechanism and effect of liver disease
    • Miles KA, McPherson SJ, Hayball MP. Transient splenic inhomogeneity with contrast-enhanced CT: Mechanism and effect of liver disease. Radiology 1995;194:91-5.
    • (1995) Radiology , vol.194 , pp. 91-95
    • Miles, K.A.1    McPherson, S.J.2    Hayball, M.P.3
  • 48
    • 0033046528 scopus 로고    scopus 로고
    • CT derived Patlak images of the human kidney
    • Miles KA, Leggett DA, Bennett GA. CT derived Patlak images of the human kidney. Br J Radiol 1999;72:153-8.
    • (1999) Br J Radiol , vol.72 , pp. 153-158
    • Miles, K.A.1    Leggett, D.A.2    Bennett, G.A.3
  • 49
    • 0029954995 scopus 로고    scopus 로고
    • Review article: The quantification of renal function with enhanced computed tomography
    • Blomley MJ, Dawson P. Review article: The quantification of renal function with enhanced computed tomography. Br J Radiol 1996;69:989-95.
    • (1996) Br J Radiol , vol.69 , pp. 989-995
    • Blomley, M.J.1    Dawson, P.2
  • 50
    • 0025765943 scopus 로고
    • Measurement of tissue perfusion by dynamic computed tomography
    • Miles KA. Measurement of tissue perfusion by dynamic computed tomography. Br J Radiol 1991;64:409-12.
    • (1991) Br J Radiol , vol.64 , pp. 409-412
    • Miles, K.A.1
  • 51
    • 0028641529 scopus 로고
    • Functional imaging of changes in human intrarenal perfusion using quantitative dynamic computed tomography
    • Miles KA, Hayball MP, Dixon AK. Functional imaging of changes in human intrarenal perfusion using quantitative dynamic computed tomography. Invest Radiol 1994;29:911-4.
    • (1994) Invest Radiol , vol.29 , pp. 911-914
    • Miles, K.A.1    Hayball, M.P.2    Dixon, A.K.3
  • 52
    • 0032838234 scopus 로고    scopus 로고
    • Functional renal perfusion imaging with colour mapping: Is it a useful adjunct to spiral CT in the assessment of abdominal aortic aneurysm (AAA)?
    • Blomley MJ, McBride A, Mohammedtagi S, Albrecht T, Harvey CJ, Jager R, et al. Functional renal perfusion imaging with colour mapping: Is it a useful adjunct to spiral CT in the assessment of abdominal aortic aneurysm (AAA)? Eur J Radiol 1999;30:214-20.
    • (1999) Eur J Radiol , vol.30 , pp. 214-220
    • Blomley, M.J.1    McBride, A.2    Mohammedtagi, S.3    Albrecht, T.4    Harvey, C.J.5    Jager, R.6
  • 53
    • 0034823736 scopus 로고    scopus 로고
    • Unilateral renal artery stenosis: Perfusion patterns with electron-beam dynamic CT-preliminary experience
    • Paul JF, Ugolini P, Sapoval M, Mousseaux E, Gaux JC. Unilateral renal artery stenosis: Perfusion patterns with electron-beam dynamic CT-preliminary experience. Radiology 2001;221:261-5.
    • (2001) Radiology , vol.221 , pp. 261-265
    • Paul, J.F.1    Ugolini, P.2    Sapoval, M.3    Mousseaux, E.4    Gaux, J.C.5
  • 54
    • 0029071147 scopus 로고
    • Measurement of human pancreatic perfusion using dynamic computed tomography with perfusion imaging
    • Miles KA, Hayball MP, Dixon AK. Measurement of human pancreatic perfusion using dynamic computed tomography with perfusion imaging. Br J Radiol 1995;68:471-5.
    • (1995) Br J Radiol , vol.68 , pp. 471-475
    • Miles, K.A.1    Hayball, M.P.2    Dixon, A.K.3
  • 55
    • 0020659564 scopus 로고
    • Tissue mean transit time from dynamic computed tomography by a simple deconvolution technique
    • Axel L. Tissue mean transit time from dynamic computed tomography by a simple deconvolution technique. Invest Radiol 1983;18:94-9.
    • (1983) Invest Radiol , vol.18 , pp. 94-99
    • Axel, L.1
  • 56
    • 0020956250 scopus 로고
    • First pass measurements of regional blood flow using external detectors
    • Mullani N, Gould KL. First pass measurements of regional blood flow using external detectors. J Nucl Med 1983;24:577-81.
    • (1983) J Nucl Med , vol.24 , pp. 577-581
    • Mullani, N.1    Gould, K.L.2
  • 57
    • 0020956774 scopus 로고
    • Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data
    • Patlak CS, Blasberg RG, Fenstermacher JD. Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J Cereb Blood Flow Metab 1983;3:1-7.
    • (1983) J Cereb Blood Flow Metab , vol.3 , pp. 1-7
    • Patlak, C.S.1    Blasberg, R.G.2    Fenstermacher, J.D.3
  • 58
    • 0026048876 scopus 로고
    • Measurement of regional cerebral blood flow using ultrafast computed tomography. Theoretical aspects
    • Gobbel GT, Cann CE, Fike JR. Measurement of regional cerebral blood flow using ultrafast computed tomography. Theoretical aspects. Stroke 1991;22:768-71.
    • (1991) Stroke , vol.22 , pp. 768-771
    • Gobbel, G.T.1    Cann, C.E.2    Fike, J.R.3
  • 60
    • 0034069356 scopus 로고    scopus 로고
    • A CT method to measure hemodynamics in brain tumors: Validation and application of cerebral blood flow maps
    • Cenic A, Nabavi DG, Craen RA, Gelb AW, Lee TY. A CT method to measure hemodynamics in brain tumors: Validation and application of cerebral blood flow maps. Am J Neuroradiol 2000;21:462-70.
    • (2000) Am J Neuroradiol , vol.21 , pp. 462-470
    • Cenic, A.1    Nabavi, D.G.2    Craen, R.A.3    Gelb, A.W.4    Lee, T.Y.5
  • 61
    • 0031690799 scopus 로고    scopus 로고
    • Perfusion CT of the brain: Diagnostic approach for early detection of ischemic stroke
    • Koenig M, Klotz E, Luka B, Venderink DJ, Spittler JF, Heuser L. Perfusion CT of the brain: Diagnostic approach for early detection of ischemic stroke. Radiology 1998;209:85-93.
    • (1998) Radiology , vol.209 , pp. 85-93
    • Koenig, M.1    Klotz, E.2    Luka, B.3    Venderink, D.J.4    Spittler, J.F.5    Heuser, L.6
  • 62
    • 0038165020 scopus 로고    scopus 로고
    • Philips Medical Systems
    • FUNCTIONAL CT, in Mx8000 Operation Manual, Vol. 2. 2000, Philips Medical Systems. p. 11-1, 11-20.
    • (2000) Mx8000 Operation Manual , vol.2
  • 63
    • 0026015068 scopus 로고
    • Measurement of regional cerebral blood flow in the dog using ultrafast computed tomography. Experimental validation
    • Gobbel GT, Cann CE, Iwamoto HS, Fike JR. Measurement of regional cerebral blood flow in the dog using ultrafast computed tomography. Experimental validation. Stroke 1991;22:772-9.
    • (1991) Stroke , vol.22 , pp. 772-779
    • Gobbel, G.T.1    Cann, C.E.2    Iwamoto, H.S.3    Fike, J.R.4
  • 64
    • 0027287749 scopus 로고
    • Comparison of xenon-enhanced CT with ultrafast CT for measurement of regional cerebral blood flow
    • Gobbel GT, Cann CE, Fike JR. Comparison of xenon-enhanced CT with ultrafast CT for measurement of regional cerebral blood flow. Am J Neuroradiol 1993;14:543-50.
    • (1993) Am J Neuroradiol , vol.14 , pp. 543-550
    • Gobbel, G.T.1    Cann, C.E.2    Fike, J.R.3
  • 67
    • 0027882557 scopus 로고
    • Contrast bolus dynamic computed tomography for the measurement of solid organ perfusion
    • discussion S78
    • Blomley MJ, Coulden R, Bufkin C, Lipton MJ, Dawson P. Contrast bolus dynamic computed tomography for the measurement of solid organ perfusion. Invest Radiol 1993;28 Suppl. 5:S72-7; discussion S78.
    • (1993) Invest Radiol , vol.28 , Issue.SUPPL. 5
    • Blomley, M.J.1    Coulden, R.2    Bufkin, C.3    Lipton, M.J.4    Dawson, P.5
  • 70
    • 0035037004 scopus 로고    scopus 로고
    • Simultaneous measurement of regional cerebral blood flow by perfusion CT and stable xenon CT: A validation study
    • Wintermark M, Thiran JP, Maeder P, Schnyder P, Meuli R. Simultaneous measurement of regional cerebral blood flow by perfusion CT and stable xenon CT: A validation study. Am J Neuroradiol 2001;22:905-14.
    • (2001) Am J Neuroradiol , vol.22 , pp. 905-914
    • Wintermark, M.1    Thiran, J.P.2    Maeder, P.3    Schnyder, P.4    Meuli, R.5
  • 71
    • 0032793705 scopus 로고    scopus 로고
    • Quantitative assessment of cerebral hemodynamics using CT: Stability, accuracy, and precision studies in dogs
    • Nabavi DG, Cenic A, Dool J, Smith RM, Espinosa F, Craen RA, et al. Quantitative assessment of cerebral hemodynamics using CT: Stability, accuracy, and precision studies in dogs. J Comput Assist Tomogr 1999;23:506-15.
    • (1999) J Comput Assist Tomogr , vol.23 , pp. 506-515
    • Nabavi, D.G.1    Cenic, A.2    Dool, J.3    Smith, R.M.4    Espinosa, F.5    Craen, R.A.6
  • 74
    • 0026050319 scopus 로고
    • Measurement of blood flow from first-pass radionuclide angiography: Influence of bolus volume
    • Bell SD, Peters AM. Measurement of blood flow from first-pass radionuclide angiography: Influence of bolus volume. Eur J Nucl Med 1991;18:885-8.
    • (1991) Eur J Nucl Med , vol.18 , pp. 885-888
    • Bell, S.D.1    Peters, A.M.2
  • 76
    • 0019163790 scopus 로고
    • Cerebral blood flow determination by rapid-sequence computed tomography: Theoretical analysis
    • Axel L. Cerebral blood flow determination by rapid-sequence computed tomography: Theoretical analysis. Radiology 1980;137:679-86.
    • (1980) Radiology , vol.137 , pp. 679-686
    • Axel, L.1
  • 77
    • 0026048876 scopus 로고
    • Measurement of regional cerebral blood flow using ultrafast computed tomography. Theoretical aspects
    • Gobbel GT, Cann CE, Fike JR. Measurement of regional cerebral blood flow using ultrafast computed tomography. Theoretical aspects. Stroke 1991;22:768-71.
    • (1991) Stroke , vol.22 , pp. 768-771
    • Gobbel, G.T.1    Cann, C.E.2    Fike, J.R.3
  • 78
    • 0021721419 scopus 로고
    • Derivation of gamma variate indicator dilution function from simple convective dispersion model of blood flow
    • Harpen MD, Lecklitner ML. Derivation of gamma variate indicator dilution function from simple convective dispersion model of blood flow. Med Phys 1984;11:690-2.
    • (1984) Med Phys , vol.11 , pp. 690-692
    • Harpen, M.D.1    Lecklitner, M.L.2
  • 79
    • 0001368031 scopus 로고
    • Regional blood flow by fractional distribution of indicators
    • Sapirstein LA. Regional blood flow by fractional distribution of indicators. Am J Physiol 1958;193:161-8.
    • (1958) Am J Physiol , vol.193 , pp. 161-168
    • Sapirstein, L.A.1
  • 80
    • 0020956250 scopus 로고
    • First pass measurements of regional blood flow using external detectors
    • Mullani N, Gould KL. First pass measurements of regional blood flow using external detectors. J Nucl Med 1983;24:577-81.
    • (1983) J Nucl Med , vol.24 , pp. 577-581
    • Mullani, N.1    Gould, K.L.2
  • 81
    • 77049181625 scopus 로고
    • On the Theory of the Indicator-Dilution Method for the measurement of blood flow and volume
    • Meier P, Zieler K. On the Theory of the Indicator-Dilution Method for the measurement of blood flow and volume. J Appl Physiol 1954;6:731-44.
    • (1954) J Appl Physiol , vol.6 , pp. 731-744
    • Meier, P.1    Zieler, K.2
  • 82
    • 0020659564 scopus 로고
    • Tissue mean transit time from dynamic computed tomography by a simple deconvolution technique
    • Axel L. Tissue mean transit time from dynamic computed tomography by a simple deconvolution technique. Invest Radiol 1983;18:94-9.
    • (1983) Invest Radiol , vol.18 , pp. 94-99
    • Axel, L.1
  • 83
    • 0026706590 scopus 로고
    • An absorptiometry method for the determination of arterial blood concentration of injected iodinated contrast agent
    • Yeung WT, Lee TY, Del Maestro RF, Kozak R, Bennett JD, Brown T. An absorptiometry method for the determination of arterial blood concentration of injected iodinated contrast agent. Phys Med Biol 1992;37:1741-58.
    • (1992) Phys Med Biol , vol.37 , pp. 1741-1758
    • Yeung, W.T.1    Lee, T.Y.2    Del Maestro, R.F.3    Kozak, R.4    Bennett, J.D.5    Brown, T.6
  • 84
    • 0034069356 scopus 로고    scopus 로고
    • A CT method to measure hemodynamics in brain tumors: Validation and application of cerebral blood flow maps
    • Cenic A, Nabavi DG, Craen RA, Gelb AW, Lee TY. A CT method to measure hemodynamics in brain tumors: Validation and application of cerebral blood flow maps. Am J Neuroradiol 2000;21:462-70.
    • (2000) Am J Neuroradiol , vol.21 , pp. 462-470
    • Cenic, A.1    Nabavi, D.G.2    Craen, R.A.3    Gelb, A.W.4    Lee, T.Y.5
  • 85
    • 0020956774 scopus 로고
    • Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data
    • Patlak CS, Blasberg RG, Fenstermacher JD. Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J Cereb Blood Flow Metab 1983;3:1-7.
    • (1983) J Cereb Blood Flow Metab , vol.3 , pp. 1-7
    • Patlak, C.S.1    Blasberg, R.G.2    Fenstermacher, J.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.