메뉴 건너뛰기




Volumn 26, Issue 1, 2014, Pages 24-48

On-site detection as a countermeasure to chemical warfare/terrorism

Author keywords

Chemical warfare agents; Detection performance; On site detection

Indexed keywords


EID: 84892562893     PISSN: 10427201     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (13)

References (163)
  • 1
    • 84892620839 scopus 로고    scopus 로고
    • Advanced portable raman spectrometer
    • Japan Accessed March 15, 2013
    • Advanced portable Raman spectrometer; Rigaku Raman Technologies: Tokyo, Japan; http://www.rigaku.com/products.raman.zantus (Accessed March 15, 2013).
    • Rigaku Raman Technologies: Tokyo
  • 2
    • 84877961083 scopus 로고    scopus 로고
    • Tewsbury, MA Accessed March 15, 2013
    • Ahura FD; Thermo Fisher Scientific: Tewsbury, MA; http://www. ahurascientific.com/chemical-explosives-id/products/ahurafd/index.php (Accessed March 15, 2013).
    • Thermo Fisher Scientific
    • Ahura, F.D.1
  • 3
    • 84884772301 scopus 로고    scopus 로고
    • Biosensors for the detection of OP nerve agents
    • Gupta RC (ed) Elsevier: Amsterdam, The Netherlands
    • Anzai J: Biosensors for the detection of OP nerve agents; In Gupta RC (ed): Handbook of the Toxicology of Chemical Warfare Agents; Elsevier: Amsterdam, The Netherlands; pp 837-846; 2009.
    • (2009) Handbook of the Toxicology of Chemical Warfare Agents , pp. 837-846
    • Anzai, J.1
  • 5
    • 0028294045 scopus 로고
    • Application of gas chromatography-mass spectrometry and gas chromatography-tandem mass spectrometry to the analysis of chemical warfare samples, found to contain residues of the nerve agent sarin, sulphur mustard and their degradation products
    • Black RM, Clarke RJ, Read R.W., Reid MTJ: Application of gas chromatography-mass spectrometry and gas chromatography-tandem mass spectrometry to the analysis of chemical warfare samples, found to contain residues of the nerve agent sarin, sulphur mustard and their degradation products; J Chromatogr 662:301; 1994.
    • (1994) J Chromatogr , vol.662 , pp. 301
    • Black, R.M.1    Clarke, R.J.2    Read, R.W.3    Reid, M.T.J.4
  • 6
    • 0038693313 scopus 로고    scopus 로고
    • Derivatization reactions in the chromatographic analysis of chemical warfare agents and their degradation products
    • Black RM, Muir B: Derivatization reactions in the chromatographic analysis of chemical warfare agents and their degradation products; J Chromatogr A 1000:253; 2003.
    • (2003) J Chromatogr A , vol.1000 , pp. 253
    • Black, R.M.1    Muir, B.2
  • 8
    • 0034833373 scopus 로고    scopus 로고
    • The response of a membrane inlet ion mobility spectrometer to chlorine and the effect of water contamination of the drying media on ion mobility spectrometric responses to chlorine
    • Bocos-Bintintan V., Brittain A, Paul Thomas CL: The response of a membrane inlet ion mobility spectrometer to chlorine and the effect of water contamination of the drying media on ion mobility spectrometric responses to chlorine; Analyst 126:1539; 2001.
    • (2001) Analyst , vol.126 , pp. 1539
    • Bocos-Bintintan, V.1    Brittain, A.2    Paul Thomas, C.L.3
  • 9
    • 34748908777 scopus 로고    scopus 로고
    • Chemical and biological threat-agent detection using electrophoresis- based lab-on-a-chip devices
    • Borowsky J, Collins GE: Chemical and biological threat-agent detection using electrophoresis-based lab-on-a-chip devices; Analyst 132:958; 2007.
    • (2007) Analyst , vol.132 , pp. 958
    • Borowsky, J.1    Collins, G.E.2
  • 10
    • 0346786417 scopus 로고    scopus 로고
    • Express analysis of explosives, chemical warfare agents and drugs with multicapillary column gas chromatography and ion mobility increment spectrometry
    • Buryakov IA: Express analysis of explosives, chemical warfare agents and drugs with multicapillary column gas chromatography and ion mobility increment spectrometry; J Chromatogr B 800:75; 2004.
    • (2004) J Chromatogr B , vol.800 , pp. 75
    • Buryakov, I.A.1
  • 12
    • 84900289708 scopus 로고    scopus 로고
    • Morphix Technologies®: Virginia Beach, VA Accessed March 15, 2013
    • Chameleon; Morphix Technologies®: Virginia Beach, VA; http://www.morphtec.com/products/chameleon/overview/31/(Accessed March 15, 2013).
    • Chameleon
  • 13
    • 84892591687 scopus 로고    scopus 로고
    • Environics Oy: Mikkeli, Finland Accessed March 15, 2013
    • Chemical detection; Environics Oy: Mikkeli, Finland; http://www. environics.fi7index.php/chemical-detection (Accessed March 15, 2013).
    • Chemical Detection
  • 14
    • 84892569577 scopus 로고    scopus 로고
    • The Hague, The Netherlands Accessed March 15, 2013
    • Chemical Weapon Convention; Organization for the Prohibition of Chemical Weapons: The Hague, The Netherlands; http://www.opcw.org (Accessed March 15, 2013).
    • Chemical Weapon Convention
  • 16
    • 17644408113 scopus 로고    scopus 로고
    • Versatile new ion source for the analysis of materials in open air under ambient conditions
    • Cody RB, Laramee JA, Durst HD: Versatile new ion source for the analysis of materials in open air under ambient conditions; Anal Chem 77:2297; 2005.
    • (2005) Anal Chem , vol.77 , pp. 2297
    • Cody, R.B.1    Laramee, J.A.2    Durst, H.D.3
  • 18
    • 35848964817 scopus 로고    scopus 로고
    • Detection of chemical weapon agents and simulants using chemical ionization reaction time-of-flight mass spectrometry
    • Cordell RC, Willis KA, Wyche K.P., Blake RS, Ellis AM, Monks PS: Detection of chemical weapon agents and simulants using chemical ionization reaction time-of-flight mass spectrometry; Anal Chem 79:8359; 2007.
    • (2007) Anal Chem , vol.79 , pp. 8359
    • Cordell, R.C.1    Willis, K.A.2    Wyche, K.P.3    Blake, R.S.4    Ellis, A.M.5    Monks, P.S.6
  • 19
    • 7644239317 scopus 로고    scopus 로고
    • Ion mobility spectrometry rediscovered
    • Cottingham K: Ion mobility spectrometry rediscovered; Anal Chem 75:435A; 2003.
    • (2003) Anal Chem , vol.75
    • Cottingham, K.1
  • 20
    • 33644853815 scopus 로고    scopus 로고
    • Detection of chemical weapon agents and simulants using chemical ionization reaction time-of-flight mass spectrometry
    • D'Agostino P.A., Hancock JR, Chenier C.L., Jackson Lepage CR: Detection of chemical weapon agents and simulants using chemical ionization reaction time-of-flight mass spectrometry; J Chromatogr A 1110:86; 2006.
    • (2006) J Chromatogr A , vol.1110 , pp. 86
    • D'Agostino, P.A.1    Hancock, J.R.2    Chenier, C.L.3    Jackson Lepage, C.R.4
  • 22
    • 7644233200 scopus 로고    scopus 로고
    • Ion mobility spectrometers in national defense
    • Eiceman GA, Stone JA: Ion mobility spectrometers in national defense; Anal Chem 76: 390A; 2004.
    • (2004) Anal Chem , vol.76
    • Eiceman, G.A.1    Stone, J.A.2
  • 23
    • 0028914261 scopus 로고
    • Enhanced selectivity in ion mobility spectrometry analysis of complex mixtures by alternate reagent gas chemistry
    • Eiceman GA, Wang YF, Garcia-Gonzalez L, Harden C.S., Shoff DB: Enhanced selectivity in ion mobility spectrometry analysis of complex mixtures by alternate reagent gas chemistry; Anal Chim Acta 306:21; 1995.
    • (1995) Anal Chim Acta , vol.306 , pp. 21
    • Eiceman, G.A.1    Wang, Y.F.2    Garcia-Gonzalez, L.3    Harden, C.S.4    Shoff, D.B.5
  • 25
    • 0035837523 scopus 로고    scopus 로고
    • A critical review of ion mobility spectrometry for the detection of explosives and explosive related compounds
    • Ewing RG, Atkinson DA, Eiceman G.A., Ewing GJ: A critical review of ion mobility spectrometry for the detection of explosives and explosive related compounds; Talanta 54:515; 2001.
    • (2001) Talanta , vol.54 , pp. 515
    • Ewing, R.G.1    Atkinson, D.A.2    Eiceman, G.A.3    Ewing, G.J.4
  • 26
    • 0347858204 scopus 로고    scopus 로고
    • Detection of chemical warfare agents in water by high temperature-solid phase microextraction-ion mobility spectrometry (HT-SPME-IMS)
    • Fallman A,Rittfeldt L: Detection of chemical warfare agents in water by high temperature-solid phase microextraction-ion mobility spectrometry (HT-SPME-IMS);Int J Ion Mobil Spectrom 4:85; 2001.
    • (2001) Int J Ion Mobil Spectrom , vol.4 , pp. 85
    • Fallman, A.1    Rittfeldt, L.2
  • 27
    • 0034193490 scopus 로고    scopus 로고
    • Lab-on-a-chip: Arevolution on biological and medical sciences
    • Figeys D, Pinto D: Lab-on-a-Chip: Arevolution on biological and medical sciences; Anal Chem 72:330A; 2000.
    • (2000) Anal Chem , vol.72
    • Figeys, D.1    Pinto, D.2
  • 28
    • 0344443825 scopus 로고    scopus 로고
    • Technology challenge in responding to biological and chemical attacks in the civilian sector
    • Fittch JP, Raber E, Imbro DR: Technology challenge in responding to biological and chemical attacks in the civilian sector; Science 302:1350; 2003.
    • (2003) Science , vol.302 , pp. 1350
    • Fittch, J.P.1    Raber, E.2    Imbro, D.R.3
  • 29
    • 84892574924 scopus 로고    scopus 로고
    • Bruker Corporation: Billerica, MA Accessed March 15, 2013
    • Fourier transform infrared; Bruker Corporation: Billerica, MA; http://www.bruker.com/products/mobile-detection/ft-ir.html (Accessed March 15, 2013).
    • Fourier Transform Infrared
  • 30
    • 70350641361 scopus 로고    scopus 로고
    • Detection and quantification of chemical warfare agents precursors and surrogates by selected ion flow tube mass spectrometry
    • Francis GJ, Milligan DB, McEwan MJ: Detection and quantification of chemical warfare agents precursors and surrogates by selected ion flow tube mass spectrometry; Anal Chem 81:8892; 2009.
    • (2009) Anal Chem , vol.81 , pp. 8892
    • Francis, G.J.1    Milligan, D.B.2    McEwan, M.J.3
  • 31
    • 84892569801 scopus 로고    scopus 로고
    • Accessed March 15, 2013
    • FTIR Gas Analyzers On-site; Gasmet Technologies Oy: http://www.gasmet.fi/ products/ftir-gas-analyzers/on-site-(portable)/ (Accessed March 15, 2013).
    • FTIR Gas Analyzers On-site
  • 32
    • 84892565184 scopus 로고    scopus 로고
    • O.I. Analytical: College Station, TX Accessed February 15, 2013
    • GC Continuous Monitoring Systems; O.I. Analytical: College Station, TX; http://www.oico.com/default.aspx?id=productline&PLID=21 (Accessed February 15, 2013).
    • GC Continuous Monitoring Systems
  • 33
    • 84892621968 scopus 로고    scopus 로고
    • Germany Accessed March 14, 2013
    • GC-IMS; GAS: Dortmund, Germany; http://www.gas-dortmund.de/Products/GC- IMS/l-367.html (Accessed March 14, 2013).
    • GC-IMS
  • 34
    • 84892611420 scopus 로고    scopus 로고
    • Germany Accessed March 15, 2013
    • GDA Fumigation; AIRSENSE Analytics: Schwerin, Germany; http://www.airsense.com/en/products/gda-fumigationl/ (Accessed March 15, 2013).
    • GDA Fumigation
  • 35
    • 0034229409 scopus 로고    scopus 로고
    • Acoustic wave microsensor arrays for vapor sensing
    • Grate JW: Acoustic wave microsensor arrays for vapor sensing; Chem Rev 100:2627; 2000.
    • (2000) Chem Rev , vol.100 , pp. 2627
    • Grate, J.W.1
  • 36
    • 0036143428 scopus 로고    scopus 로고
    • A disposable amperometric biosensor for rapid screening of anticholinesterase activity in soil extracts
    • Guerrieri A, Monaci L, Quinto M., Palmesano F: A disposable amperometric biosensor for rapid screening of anticholinesterase activity in soil extracts; Analyst 127:5; 2005.
    • (2005) Analyst , vol.127 , pp. 5
    • Guerrieri, A.1    Monaci, L.2    Quinto, M.3    Palmesano, F.4
  • 37
    • 8444223860 scopus 로고    scopus 로고
    • High-field asymmetric waveform ion mobility spectrometry: A new tool for mass spectrometry
    • Guevremont R: High-field asymmetric waveform ion mobility spectrometry: A new tool for mass spectrometry; J Chromatogr A 1058:3; 2004.
    • (2004) J Chromatogr A , vol.1058 , pp. 3
    • Guevremont, R.1
  • 39
    • 0032738605 scopus 로고    scopus 로고
    • Microfluidic assays of acetylcholinesterase inhibitors
    • Hadd AG, Jacobson SC, Ramsey JM: Microfluidic assays of acetylcholinesterase inhibitors; Anal Chem 71:5206; 1999.
    • (1999) Anal Chem , vol.71 , pp. 5206
    • Hadd, A.G.1    Jacobson, S.C.2    Ramsey, J.M.3
  • 40
    • 4644291347 scopus 로고    scopus 로고
    • Chemical weapons of japanese imperial forces and their risk in environment
    • Hanaoka N: Chemical weapons of Japanese Imperial Forces and their risk in environment; Jpn J Toxicol 17:117; 2004.
    • (2004) Jpn J Toxicol , vol.17 , pp. 117
    • Hanaoka, N.1
  • 41
    • 84892565217 scopus 로고    scopus 로고
    • INFICON: Basel, Switzerland Accessed March 15, 2013
    • Hapsite ER Chemical Identification System; INFICON: Basel, Switzerland; http://www.inficonenvironrnentalmonitoring.com/en/hapsite-er/index.html?-utma= 84671809.836670170.1360918408.1360918408.1360918408.l&-utmb=84671809.1.10. 1360918408&-utmc=84671809&-utmx=-&-utmz=84671809.1360918408.1.1. utmtzr=(direct)|utmccn=(direct)|utmcmd=(n one)&-utmv=-&-utmk=l82289070 (Accessed March 15, 2013).
    • Chemical Identification System
    • Hapsite, E.R.1
  • 42
    • 0036500202 scopus 로고    scopus 로고
    • The science of detecting terror
    • Harris CM: The science of detecting terror; Anal Chem 74:126A;2002.
    • (2002) Anal Chem , vol.74
    • Harris, C.M.1
  • 43
    • 3042731120 scopus 로고    scopus 로고
    • Seeing SAW potential
    • Harris CM: Seeing SAW potential; Anal Chem 75:355A; 2003.
    • (2003) Anal Chem , vol.75
    • Harris, C.M.1
  • 44
    • 84892617857 scopus 로고    scopus 로고
    • UK Accessed March 15, 2013
    • HazMatID 360; Smiths Detection: Watfork, UK; http://www.smithsdetection. com (Accessed March 15, 2013).
    • HazMatID 360
  • 45
    • 0001347406 scopus 로고    scopus 로고
    • Taking the show on the road: Portable GC and GC/MS
    • Henry C: Taking the show on the road: Portable GC and GC/MS; Anal Chem 69:195A; 1997.
    • (1997) Anal Chem , vol.69
    • Henry, C.1
  • 48
    • 0037184658 scopus 로고    scopus 로고
    • Analytical separation techniques for the determination of chemical warfare agents
    • Hooijschuur EWJ, Kientz CE, Brinkman UAT: Analytical separation techniques for the determination of chemical warfare agents; J Chromatogr A 982:177; 2002.
    • (2002) J Chromatogr A , vol.982 , pp. 177
    • Hooijschuur, E.W.J.1    Kientz, C.E.2    Brinkman, U.A.T.3
  • 49
    • 0035281538 scopus 로고    scopus 로고
    • Detection and classification characteristics of arrays of carbon black/organic polymer composite chemiresistive vapor detectors fot the nerve agent simulants dimethy lmethylphosphonate and diisopropylmethylphosphonate
    • Hopkins AR, Lewis NS: Detection and classification characteristics of arrays of carbon black/organic polymer composite chemiresistive vapor detectors fot the nerve agent simulants dimethy lmethylphosphonate and diisopropylmethylphosphonate; Anal Chem 73:884; 2001.
    • (2001) Anal Chem , vol.73 , pp. 884
    • Hopkins, A.R.1    Lewis, N.S.2
  • 50
    • 33947086174 scopus 로고
    • New pictogram detection system based on a mass spectrometer with an external ionization source at atmospheric pressure
    • Horning EC, Horning MG, Carroll D.I., Dzidic I., Stillwell RN: New pictogram detection system based on a mass spectrometer with an external ionization source at atmospheric pressure; Anal Chem 45:936; 1973.
    • (1973) Anal Chem , vol.45 , pp. 936
    • Horning, E.C.1    Horning, M.G.2    Carroll, D.I.3    Dzidic, I.4    Stillwell, R.N.5
  • 53
    • 0004269112 scopus 로고    scopus 로고
    • Billerica, MA Accessed March 15, 2013
    • Ion mobility spectrometry; Bruker Corporation: Billerica, MA; http://www.bruker.com/products/mobile-detection/ims.html (Accessed March 15, 2013).
    • Ion Mobility Spectrometry
  • 55
    • 1842686658 scopus 로고    scopus 로고
    • Detection of proteinous toxins using the bio threat alert system
    • Iura K, Tsuge K, Seto Y., Sato A: Detection of proteinous toxins using the Bio Threat Alert System; Jpn J Forensic Toxicol 22:13;2004.
    • (2004) Jpn J Forensic Toxicol , vol.22 , pp. 13
    • Iura, K.1    Tsuge, K.2    Seto, Y.3    Sato, A.4
  • 57
    • 84892598607 scopus 로고    scopus 로고
    • Japan Accessed March 15, 2013
    • JASCO Corporation: Tokyo, Japan; http://www.jasco.co.jp/ (Accessed March 15, 2013).
  • 58
    • 84892579170 scopus 로고    scopus 로고
    • Chorlotte, NC Accessed March 15, 2013
    • JUNO; Chemring Detection Systems: Chorlotte, NC; http://www. chemringdetectionsystems.com/Products/ChemicalDetection/JUNOl (Accessed March 15, 2013).
    • Chemring Detection Systems
  • 59
    • 54349127918 scopus 로고    scopus 로고
    • Laboratory identification of the nerve gas hydrolysis products alkyl methylphosphonic acids and methylphosphonic acid, by gas chromatography-mass spectrometry after tert-butyldimethylsilylation
    • Kanamori-Kataoka M., Seto Y: Laboratory identification of the nerve gas hydrolysis products alkyl methylphosphonic acids and methylphosphonic acid, by gas chromatography-mass spectrometry after tert-butyldimethylsilylation; J Health Sci 54:513; 2008.
    • (2008) J Health Sci , vol.54 , pp. 513
    • Kanamori-Kataoka, M.1    Seto, Y.2
  • 60
    • 27144537112 scopus 로고    scopus 로고
    • Surface detection of chemical warfare agent simulants and degradation products
    • Kanu AB, Haigh PE, Hill HH: Surface detection of chemical warfare agent simulants and degradation products; Anal Chim Acta 553:148; 2005.
    • (2005) Anal Chim Acta , vol.553 , pp. 148
    • Kanu, A.B.1    Haigh, P.E.2    Hill, H.H.3
  • 61
    • 85022438154 scopus 로고
    • Plasma chromatography
    • Karasek FW: Plasma chromatography; Anal Chem 46:710A; 1974.
    • (1974) Anal Chem , vol.46
    • Karasek, F.W.1
  • 63
    • 23444453067 scopus 로고    scopus 로고
    • A new method and apparatus for on-site detection of trace levels of chemical warfare agents
    • Kendler S, Zifman A, Gratziany N., Zaltsman A, Frishman G: A new method and apparatus for on-site detection of trace levels of chemical warfare agents; Anal Chim Acta 548:58; 2005.
    • (2005) Anal Chim Acta , vol.548 , pp. 58
    • Kendler, S.1    Zifman, A.2    Gratziany, N.3    Zaltsman, A.4    Frishman, G.5
  • 64
    • 0024619326 scopus 로고
    • Real-time detection of part per trillion levels of chemical warfare agents in ambient air using atmospheric pressure ionization tandem quadrupole mass spectrometry
    • Ketkar S, Penn SM, Fite WL: Real-time detection of part per trillion levels of chemical warfare agents in ambient air using atmospheric pressure ionization tandem quadrupole mass spectrometry; Anal Chem 61:260; 1989.
    • (1989) Anal Chem , vol.61 , pp. 260
    • Ketkar, S.1    Penn, S.M.2    Fite, W.L.3
  • 65
    • 41949116320 scopus 로고    scopus 로고
    • Noncovalent modification of carbon nanotubes with ferrocene-amino acid conjugates for electrochemical sensing of chemical warfare agent mimins
    • Khan MAK, Kerman K, Petryel M., Kraatz HB: Noncovalent modification of carbon nanotubes with ferrocene-amino acid conjugates for electrochemical sensing of chemical warfare agent mimins; Anal Chem 80:2574; 2008.
    • (2008) Anal Chem , vol.80 , pp. 2574
    • Khan, M.A.K.1    Kerman, K.2    Petryel, M.3    Kraatz, H.B.4
  • 66
    • 79951516647 scopus 로고    scopus 로고
    • New method for comprehensive detection of chemical warfare agents using an electron-cyclotron-resonance ion-source mass spectrometer
    • Kidera M, Seto Y, Takahashi K., Enomoto S, Kishi S, Makita M., Nagamatsu T, Tanaka T, Toda M: New method for comprehensive detection of chemical warfare agents using an electron-cyclotron-resonance ion-source mass spectrometer; Spectrochim Acta A 78:1215; 2011.
    • (2011) Spectrochim Acta A , vol.78 , pp. 1215
    • Kidera, M.1    Seto, Y.2    Takahashi, K.3    Enomoto, S.4    Kishi, S.5    Makita, M.6    Nagamatsu, T.7    Tanaka, T.8    Toda, M.9
  • 67
    • 0031825732 scopus 로고    scopus 로고
    • Chromatography and mass spectrometry of chemical warfare agents, toxins and related compounds: State of the art and future prospects
    • Kientz CE: Chromatography and mass spectrometry of chemical warfare agents, toxins and related compounds: state of the art and future prospects; J Chromatogr A 814:1; 1998.
    • (1998) J Chromatogr A , vol.814 , pp. 1
    • Kientz, C.E.1
  • 68
    • 77953691570 scopus 로고    scopus 로고
    • Evaluation of detection performance of chemical warfare agents with portable aspiration-type ion mobility spectrometer 2
    • Kishi S, Asada R, Sekioka R., Sedeyama M, Shiga M, Seto Y: Evaluation of detection performance of chemical warfare agents with portable aspiration-type ion mobility spectrometer 2; Bunseki Kagaku 59:65; 2010.
    • (2010) Bunseki Kagaku , vol.59 , pp. 65
    • Kishi, S.1    Asada, R.2    Sekioka, R.3    Sedeyama, M.4    Shiga, M.5    Seto, Y.6
  • 69
    • 0005049538 scopus 로고    scopus 로고
    • Vapor detection of TNT and RDX using atmospheric pressure chemical ionization mass spectrometry with counter-flow introduction(CFI)
    • Kojima K, Sakairi M, Takada Y., Nakamura J: Vapor detection of TNT and RDX using atmospheric pressure chemical ionization mass spectrometry with counter-flow introduction(CFI); J Mass Spectrom Soc Jpn 48:360;2000.
    • (2000) J Mass Spectrom Soc Jpn , vol.48 , pp. 360
    • Kojima, K.1    Sakairi, M.2    Takada, Y.3    Nakamura, J.4
  • 70
    • 34548049977 scopus 로고    scopus 로고
    • Review of applications of high-field asymmetric waveform ion mobility spectrometry (FAIMS) and differential mobility spectrometry (DMS)
    • Kolakowski BM, Mester Z: Review of applications of high-field asymmetric waveform ion mobility spectrometry (FAIMS) and differential mobility spectrometry (DMS); Analyst 132:842; 2007.
    • (2007) Analyst , vol.132 , pp. 842
    • Kolakowski, B.M.1    Mester, Z.2
  • 71
    • 79251603357 scopus 로고    scopus 로고
    • Performance of PSP rapid test, a commercial lateral flow immunoassay kit for detection of saxitoxin in counterterrorism aspect
    • Komano A, Maruko H, Sekiguchi H., Seto Y: Performance of PSP Rapid Test, a commercial lateral flow immunoassay kit for detection of saxitoxin in counterterrorism aspect; Forensic Toxicol 29:38; 2011.
    • (2011) Forensic Toxicol , vol.29 , pp. 38
    • Komano, A.1    Maruko, H.2    Sekiguchi, H.3    Seto, Y.4
  • 72
    • 84892586193 scopus 로고    scopus 로고
    • LCD Watfork, UK Accessed March 15, 2013
    • LCD (Lightweight Chemical Detector); Smiths Detection: Watfork, UK; http://www.smithsdetection.com/LVCD.php (Accessed March 15, 2013).
    • Lightweight Chemical Detector
  • 73
    • 33749991856 scopus 로고    scopus 로고
    • Trends in detection of warfare agents - Detection methods for ricin, staphylococcal enterotoxin B and T-2 toxin
    • Ler SG, Lee FK, Gopalakrishnakone P: Trends in detection of warfare agents - Detection methods for ricin, staphylococcal enterotoxin B and T-2 toxin; J Chromatogr A 1133:1; 2006.
    • (2006) J Chromatogr A , vol.1133 , pp. 1
    • Ler, S.G.1    Lee, F.K.2    Gopalakrishnakone, P.3
  • 74
    • 84892621598 scopus 로고    scopus 로고
    • Lonestar portable gas analyzer
    • CT Accessed March 14, 2013
    • Lonestar Portable Gas Analyzer; Owlstone Inc.: Norwalk, CT; http://www.owlstonenanotech.com/lonestar (Accessed March 14, 2013).
    • Owlstone Inc.: Norwalk
  • 75
    • 84892589023 scopus 로고    scopus 로고
    • M90 and M100 Single Detector FTIR Spectrometers MA Accessed March 15, 2013
    • M90 and M100 Single Detector FTIR Spectrometers; Block Engineering: Marlborough, MA; http://www.blockeng.com/products/ml00.html (Accessed March 15, 2013).
    • Block Engineering: Marlborough
  • 76
    • 0348047483 scopus 로고    scopus 로고
    • Field gas chromatography-mass spectrometry for fast analysis
    • Makas AL, Troshkov ML: Field gas chromatography-mass spectrometry for fast analysis; J Chromatogr B 800:55; 2004.
    • (2004) J Chromatogr B , vol.800 , pp. 55
    • Makas, A.L.1    Troshkov, M.L.2
  • 78
    • 33745041558 scopus 로고    scopus 로고
    • Detection performance of aspiration-type ion mobility spectrometer for chemical warfare agents
    • Maruko H, Sekiguchi H, Seto Y., Sato A: Detection performance of aspiration-type ion mobility spectrometer for chemical warfare agents; Bunseki Kagaku 55:191; 2006.
    • (2006) Bunseki Kagaku , vol.55 , pp. 191
    • Maruko, H.1    Sekiguchi, H.2    Seto, Y.3    Sato, A.4
  • 80
    • 19744367377 scopus 로고    scopus 로고
    • Performance of portable surface acoustic wave sensor array chemical agent detector
    • Matsushita K, Sekiguchi H, Seto Y: Performance of portable surface acoustic wave sensor array chemical agent detector. Bunseki Kagaku 54:83; 2005.
    • (2005) Bunseki Kagaku , vol.54 , pp. 83
    • Matsushita, K.1    Sekiguchi, H.2    Seto, Y.3
  • 81
  • 82
    • 84892601866 scopus 로고    scopus 로고
    • MicroFID II portable flame ionization detector NY Accessed March 15
    • MicroFID II portable flame ionization detector; INFICON: East Syracuse, NY; http://www.inficonenvironmentalmonitoring.com/en/microfidll/index.html?- utma=84671809.1326615301.1361722088.1361722088.1361722088.l&-utmb=84671809. 2.10.1361722088&-utmc=84671809&-utmx=-&-utmz=84671809.1361722088.1. 1.utmcsr=photovac.com]utmccn=(referral)|utmcmd=referral|utmcct=/&-utmv= -&-utmk=252874240 (Accessed March 15, 2013).
    • (2013) INFICON: East Syracuse
  • 83
    • 33845783072 scopus 로고    scopus 로고
    • Portable FTIR spectrometers get moving
    • Mukhopadhyay R: Portable FTIR spectrometers get moving; Anal Chem 76:369A; 2004.
    • (2004) Anal Chem , vol.76
    • Mukhopadhyay, R.1
  • 84
    • 0344043320 scopus 로고    scopus 로고
    • Characterisation of the molecular ions produced by a dinitroalkane in positive mode ion mobility spectrometry with water, dichlorome-thane and ammonia reactant ion chemistries
    • Munro WA, Paul Thomas CL, Langford ML: Characterisation of the molecular ions produced by a dinitroalkane in positive mode ion mobility spectrometry with water, dichlorome-thane and ammonia reactant ion chemistries; Anal Chim Acta 374:253; 1998.
    • (1998) Anal Chim Acta , vol.374 , pp. 253
    • Munro, W.A.1    Paul Thomas, C.L.2    Langford, M.L.3
  • 86
    • 84863179658 scopus 로고    scopus 로고
    • Glycotechnology for decontamination of biological agents: Amodel study using ricin and biotin-tagged synthetic glycopolymers
    • Nagatsuka T, Uzawa H, Sato K., Ohsawa I, Seto Y, Nishida Y: Glycotechnology for decontamination of biological agents: Amodel study using ricin and biotin-tagged synthetic glycopolymers; Appl Mater Interface 4:832; 2012.
    • (2012) Appl Mater Interface , vol.4 , pp. 832
    • Nagatsuka, T.1    Uzawa, H.2    Sato, K.3    Ohsawa, I.4    Seto, Y.5    Nishida, Y.6
  • 87
    • 58149515362 scopus 로고    scopus 로고
    • Development of tapes for the determination of toxic gases by a monitoring tape method
    • Nakano N, Nagashima K: Development of tapes for the determination of toxic gases by a monitoring tape method; Bunseki 2001:7; 2001.
    • (2001) Bunseki , vol.2001 , pp. 7
    • Nakano, N.1    Nagashima, K.2
  • 89
    • 68849094417 scopus 로고    scopus 로고
    • Quantitation of chemical warfare agents using the direct analysis in real time (DART) technique
    • Nilles JM, Connell TR, Durst HD: Quantitation of chemical warfare agents using the direct analysis in real time (DART) technique; Anal Chem 81:6744; 2009.
    • (2009) Anal Chem , vol.81 , pp. 6744
    • Nilles, J.M.1    Connell, T.R.2    Durst, H.D.3
  • 90
    • 0036431612 scopus 로고    scopus 로고
    • Biomonitoring of exposure to chemical warfare agents: A review
    • Noort D, Benschop HP, Black RM: Biomonitoring of exposure to chemical warfare agents: A review; Toxicol Appl Pharmacol 184:116; 2002.
    • (2002) Toxicol Appl Pharmacol , vol.184 , pp. 116
    • Noort, D.1    Benschop, H.P.2    Black, R.M.3
  • 91
    • 4644336174 scopus 로고    scopus 로고
    • Chemical weapons in the earth
    • Ohashi N: Chemical weapons in the earth; Jpn J Toxicol 17:113; 2004.
    • (2004) Jpn J Toxicol , vol.17 , pp. 113
    • Ohashi, N.1
  • 92
    • 0029764615 scopus 로고    scopus 로고
    • Biosensors forchemical and biological agents of defence interest
    • Paddle BM: Biosensors forchemical and biological agents of defence interest; Biosens Bioelectron 11:1079; 1996.
    • (1996) Biosens Bioelectron , vol.11 , pp. 1079
    • Paddle, B.M.1
  • 93
    • 0037503914 scopus 로고    scopus 로고
    • Therapy and prophylaxis of inhaled biological toxins
    • Paddle BM: Therapy and prophylaxis of inhaled biological toxins; J Appl Toxicol 23:139; 2003.
    • (2003) J Appl Toxicol , vol.23 , pp. 139
    • Paddle, B.M.1
  • 94
    • 0026838908 scopus 로고
    • Determination of organophosphorus insecticides with a choline electrochemical biosensor
    • Palleschi G, Bernabei M, Cremisini G., Mascini M: Determination of organophosphorus insecticides with a choline electrochemical biosensor; Sensor Actuat B 7:513; 1992.
    • (1992) Sensor Actuat B , vol.7 , pp. 513
    • Palleschi, G.1    Bernabei, M.2    Cremisini, G.3    Mascini, M.4
  • 95
    • 84892611715 scopus 로고    scopus 로고
    • Riken Keiki Co.: Wako, Japan Accessed March 15
    • Portable Single Gas; Riken Keiki Co.: Wako, Japan; http://www.rikenkeiki. co.jp/Default.aspx?TabId=62&catid=28&pcatid=22 (Accessed March 15, 2013).
    • (2013) Portable Single Gas
  • 96
    • 84892605410 scopus 로고    scopus 로고
    • San Jose, CA Accessed March 15, 2013
    • ppbRAE 3000; RAE Systems: San Jose, CA; http://www.raesystems.com/ products/ppbrae-3000 (Accessed March 15, 2013).
    • PpbRAE 3000
  • 97
    • 0000154606 scopus 로고
    • Plasma chromatography of phosphorus esters
    • Preston JM,Karasek FW, Kim SH: Plasma chromatography of phosphorus esters; Anal Chem 49: 1746; 1977.
    • (1977) Anal Chem , vol.49 , pp. 1746
    • Preston, J.M.1    Karasek, F.W.2    Kim, S.H.3
  • 98
    • 84892618331 scopus 로고    scopus 로고
    • Hitachi High-Tech: Mito, Japan Accessed March 15
    • Process Gas Monitor CP-1000; Hitachi High-Tech: Mito, Japan; http://www.hitachi-hitec.com/group/hcs/catalog-e/catalog-e/overview-e-ht-g-011e. pdf (Accessed March 15, 2013).
    • (2013) Process Gas Monitor CP-1000
  • 99
    • 50149120507 scopus 로고    scopus 로고
    • Ion mobility spectrometers with doped gases
    • Puton J, Nousiainen M, Sillanpaa M: Ion mobility spectrometers with doped gases; Talanta 76:978; 2008.
    • (2008) Talanta , vol.76 , pp. 978
    • Puton, J.1    Nousiainen, M.2    Sillanpaa, M.3
  • 100
    • 0038777531 scopus 로고    scopus 로고
    • The role of chromatography in the hunt for red tide toxins
    • Quilliam MA: The role of chromatography in the hunt for red tide toxins; J Chromatogr A 1000:527; 2003.
    • (2003) J Chromatogr A , vol.1000 , pp. 527
    • Quilliam, M.A.1
  • 101
    • 0016520487 scopus 로고
    • Theory of plasma chromato-graphy/gaseous electrophoresis - A review
    • Revercomb HE, Mason EA: Theory of plasma chromato-graphy/gaseous electrophoresis - A review; Anal Chem 47:970; 1975.
    • (1975) Anal Chem , vol.47 , pp. 970
    • Revercomb, H.E.1    Mason, E.A.2
  • 102
    • 0346598144 scopus 로고    scopus 로고
    • An IMS/MS investigation of lewisite and lewisite/mustard mixtures
    • Ringer J, Ross SK, West DJ: An IMS/MS investigation of lewisite and lewisite/mustard mixtures; Int J Ion Mobil Spectrom 5:107; 2002.
    • (2002) Int J Ion Mobil Spectrom , vol.5 , pp. 107
    • Ringer, J.1    Ross, S.K.2    West, D.J.3
  • 103
    • 42449096448 scopus 로고    scopus 로고
    • The use of dopants in high field asymmetric waveform spectrometry
    • Ross SK, Mcdonald G, Marchant S: The use of dopants in high field asymmetric waveform spectrometry; Analyst 133:602; 2008.
    • (2008) Analyst , vol.133 , pp. 602
    • Ross, S.K.1    Mcdonald, G.2    Marchant, S.3
  • 104
    • 0033231347 scopus 로고    scopus 로고
    • Polyethylene glycol) hydrogel-encapsulated fluorophore-enzyme conjugates for direct detection of organophosphorus neurotoxins
    • Russell RJ, Pishko MV, Simonian A.J., Wild JR: Polyethylene glycol) hydrogel-encapsulated fluorophore-enzyme conjugates for direct detection of organophosphorus neurotoxins; Anal Chem 71:4909; 1999.
    • (1999) Anal Chem , vol.71 , pp. 4909
    • Russell, R.J.1    Pishko, M.V.2    Simonian, A.J.3    Wild, J.R.4
  • 105
    • 0034874362 scopus 로고    scopus 로고
    • Stand-off tissue-based biosensors for the detection of chemical warfare agents using photosynthetic fluorescence induction
    • Sanders CA, Rodriguez MR Jr, Greenbaum E: Stand-off tissue-based biosensors for the detection of chemical warfare agents using photosynthetic fluorescence induction; Biosens Bioelectron 16:439; 2001.
    • (2001) Biosens Bioelectron , vol.16 , pp. 439
    • Sanders, C.A.1    Rodriguez Jr., M.R.2    Greenbaum, E.3
  • 107
    • 33747458138 scopus 로고    scopus 로고
    • On-site determination of nerve gases and mustard gas using a filed-portable gas chromatography-mass spectrometer
    • Sekiguchi H, Matsushita K, Yamashiro S., Sano Y, Seto Y, Okuda T, Sato A: On-site determination of nerve gases and mustard gas using a filed-portable gas chromatography-mass spectrometer; Forensic Toxicol 24:17; 2006.
    • (2006) Forensic Toxicol , vol.24 , pp. 17
    • Sekiguchi, H.1    Matsushita, K.2    Yamashiro, S.3    Sano, Y.4    Seto, Y.5    Okuda, T.6    Sato, A.7
  • 108
    • 33847634700 scopus 로고    scopus 로고
    • Detection performance of portable corona discharge ionization type ion mobility spectrometer for chemical warfare agents
    • Sekioka R, Takayama Y, Seto Y., Urasaki Y, Shinzawa H: Detection performance of portable corona discharge ionization type ion mobility spectrometer for chemical warfare agents; Bunseki Kagaku 56:17; 2007.
    • (2007) Bunseki Kagaku , vol.56 , pp. 17
    • Sekioka, R.1    Takayama, Y.2    Seto, Y.3    Urasaki, Y.4    Shinzawa, H.5
  • 109
    • 33846192733 scopus 로고    scopus 로고
    • Analytical and on-site detection methods for chemical warfare agents
    • Seto Y: Analytical and on-site detection methods for chemical warfare agents; Yakugaku Zasshi 126:1279; 2006.
    • (2006) Yakugaku Zasshi , vol.126 , pp. 1279
    • Seto, Y.1
  • 110
    • 33845804660 scopus 로고    scopus 로고
    • On-site detection method for biological and chemical warfare agents
    • Seto Y: On-site detection method for biological and chemical warfare agents; Bunseki Kagaku 55:891; 2006.
    • (2006) Bunseki Kagaku , vol.55 , pp. 891
    • Seto, Y.1
  • 111
    • 84884780950 scopus 로고    scopus 로고
    • On-site detection of chemical warfare agents
    • Gupta RC (ed) Elsevier: Amsterdam, The Netherlands
    • Seto Y: On-site detection of chemical warfare agents; In Gupta RC (ed): Handbook of the Toxicology of Chemical Warfare Agents; Elsevier: Amsterdam, The Netherlands; pp 813-825; 2009.
    • (2009) Handbook of the Toxicology of Chemical Warfare Agents , pp. 813-825
    • Seto, Y.1
  • 112
    • 79961000412 scopus 로고    scopus 로고
    • Research and development of on-site decontamination system for biological and chemical warfare agents
    • Seto Y: Research and development of on-site decontamination system for biological and chemical warfare agents; J Health Sci 57: 311; 2011.
    • (2011) J Health Sci , vol.57 , pp. 311
    • Seto, Y.1
  • 113
    • 84892623575 scopus 로고    scopus 로고
    • SarIn gas attacks In Japan and Forensic Investigations - A Case Report
    • Majumdar SK, Rosenfeld LM, Miller EW, Alexander SS, Rieders MF, Panah AL (eds) The Pennsylvania Academy of Science: Easton, PA
    • Seto Y: SarIn gas attacks In Japan and forensic investigations - A case report; in Majumdar SK, Rosenfeld LM, Miller EW, Alexander SS, Rieders MF, Panah AL (eds): Science, Technology and National Surity; The Pennsylvania Academy of Science: Easton, PA; pp 74-88; 2002.
    • (2002) Science, Technology and National Surity , pp. 74-88
    • Seto, Y.1
  • 115
    • 25844453937 scopus 로고    scopus 로고
    • Mass spectrometric strategy for the determination of natural and synthetic organic toxins
    • Seto Y, Kanamori-Kataoka M: Mass spectrometric strategy for the determination of natural and synthetic organic toxins; J Health Sci 51:519; 2005.
    • (2005) J Health Sci , vol.51 , pp. 519
    • Seto, Y.1    Kanamori-Kataoka, M.2
  • 116
    • 58149530537 scopus 로고    scopus 로고
    • Mass spectrometric technologies for countering chemical and biological terrorism incidents
    • Seto Y, Kanamori-Kataoka M, Tsuge K: Mass spectrometric technologies for countering chemical and biological terrorism incidents; J Mass Spectrom Soc Jpn 56:91; 2008.
    • (2008) J Mass Spectrom Soc Jpn , vol.56 , pp. 91
    • Seto, Y.1    Kanamori-Kataoka, M.2    Tsuge, K.3
  • 117
    • 84874638841 scopus 로고    scopus 로고
    • Sensitive monitoring of volatile chemical warfare agents in air by atmospheric pressure chemical ionization mass spectrometry with counter-flow introduction
    • Seto Y, Kanamori-Kataoka M, Tsuge K.,Ohsawa I, Iura K, Itoi T, Sekiguchi H, Matsushita K, Yamashiro S, Sano Y, et al.: Sensitive monitoring of volatile chemical warfare agents in air by atmospheric pressure chemical ionization mass spectrometry with counter-flow introduction; Anal Chem 85:2659; 2013.
    • (2013) Anal Chem , vol.85 , pp. 2659
    • Seto, Y.1    Kanamori-Kataoka, M.2    Tsuge, K.3    Ohsawa, I.4    Iura, K.5    Itoi, T.6    Sekiguchi, H.7    Matsushita, K.8    Yamashiro, S.9    Sano, Y.10
  • 120
    • 0042094970 scopus 로고    scopus 로고
    • Toxicological analysis of victims' blood and crime scene evidence samples in the sarin gas attack caused by the Aum Shinrikyo Cult
    • Seto Y, Tsunoda N, Kataoka M., Tsuge K, Nagano T: Toxicological analysis of victim's blood and crime scene evidence samples In the sarIn gas attack caused by the Aum Shinrikyo cult; in Tu AT, Gaffield W (eds): Natural and Selected Synthetic Toxins - Biological Implications; American Chemical Society: Washington, DC; pp 318-332; 2000. (Pubitemid 129563357)
    • (1999) ACS Symposium Series , vol.745 , pp. 318-332
    • Seto, Y.1    Tsunoda, N.2    Kataoka, M.3    Tsuge, K.4    Nagano, T.5
  • 121
    • 0347361592 scopus 로고    scopus 로고
    • Subnanomolar cyanide detection at polyphenol oxidase/clay biosensors
    • Shan D, Mousty C, Cosnier S: Subnanomolar cyanide detection at polyphenol oxidase/clay biosensors; Anal Chem 76:178; 2004.
    • (2004) Anal Chem , vol.76 , pp. 178
    • Shan, D.1    Mousty, C.2    Cosnier, S.3
  • 123
    • 40849111429 scopus 로고    scopus 로고
    • Mass spectrometric study of negative ions extracted from point to plane negative corona discharge in ambient air at atmospheric pressure
    • Skalny JD, Orszagh J, Mason N.J., Rees, JA, Aranda-Gonzalvo Y, Whitmore TD: Mass spectrometric study of negative ions extracted from point to plane negative corona discharge in ambient air at atmospheric pressure; Int J Mass Spectrom 272:12; 2008.
    • (2008) Int J Mass Spectrom , vol.272 , pp. 12
    • Skalny, J.D.1    Orszagh, J.2    Mason, N.J.3    Rees, J.A.4    Aranda-Gonzalvo, Y.5    Whitmore, T.D.6
  • 124
    • 79955101587 scopus 로고    scopus 로고
    • Facility monitoring of chemical warfare agent simulants in air using an automated, field-deployable, miniature mass spectrometer
    • Smith JN, Noll RJ, Cooks RG: Facility monitoring of chemical warfare agent simulants in air using an automated, field-deployable, miniature mass spectrometer; Rapid Commun Mass Spectrom 25:1437; 2011.
    • (2011) Rapid Commun Mass Spectrom , vol.25 , pp. 1437
    • Smith, J.N.1    Noll, R.J.2    Cooks, R.G.3
  • 125
    • 79952774170 scopus 로고    scopus 로고
    • Use of a hand-portable gas chromatograph-toroidal ion trap mass spectrometer for self-chemical ionization identification of degradation products related to 0-ethyl-S-(2-diisopropylaminoethyl) methyl phosphonothiolate(VX)
    • Smith PA, Jackson Lepage GR, Savage PB, Bowerbank CR, Lee ED, Lukacs MJ: Use of a hand-portable gas chromatograph-toroidal ion trap mass spectrometer for self-chemical ionization identification of degradation products related to 0-ethyl-S-(2-diisopropylaminoethyl) methyl phosphonothiolate(VX); Anal Chim Acta 690:215; 2011.
    • (2011) Anal Chim Acta , vol.690 , pp. 215
    • Smith, P.A.1    Jackson Lepage, G.R.2    Savage, P.B.3    Bowerbank, C.R.4    Lee, E.D.5    Lukacs, M.J.6
  • 127
    • 0036714548 scopus 로고    scopus 로고
    • Analytical chemistry at the forefront of homeland defense
    • Smith WD: Analytical chemistry at the forefront of homeland defense; Anal Chem 74:462A; 2003.
    • (2003) Anal Chem , vol.74
    • Smith, W.D.1
  • 128
    • 84892608919 scopus 로고    scopus 로고
    • Society for countermeasures against chemical, biological, radiological, nuclear and explosive terrorism
    • Shindan To Chiryo Sha: Tokyo, Japan
    • Society for Countermeasures against Chemical, Biological, Radiological, Nuclear and Explosive Terrorism: Nuclear, Biological and Chemical Terrorism Countermeasure Handbook; Shindan To Chiryo Sha: Tokyo, Japan; 2008.
    • (2008) Nuclear, Biological and Chemical Terrorism Countermeasure Handbook
  • 129
    • 0010586406 scopus 로고    scopus 로고
    • Use of ion mobility spectrometry forthe preliminary evaluation of hazardous military waste sites - Opportunities and limitations
    • Sohn H, Steinhanses J: Use of ion mobility spectrometry forthe preliminary evaluation of hazardous military waste sites - Opportunities and limitations; Int J Ion Mobil Spectrom 1:1; 1998.
    • (1998) Int J Ion Mobil Spectrom , vol.1 , pp. 1
    • Sohn, H.1    Steinhanses, J.2
  • 131
    • 48749146314 scopus 로고
    • Membrane inlet ion mobility spectrometry (plasma chromatography)
    • Spangler GE, Carrico JP: Membrane inlet ion mobility spectrometry (plasma chromatography); Int J Mass Spectrom Ion Phys 52:267; 1983.
    • (1983) Int J Mass Spectrom Ion Phys , vol.52 , pp. 267
    • Spangler, G.E.1    Carrico, J.P.2
  • 132
    • 18144380745 scopus 로고    scopus 로고
    • Ion mobility spectrometry-basic elements and applications
    • Stach J, Baumbach JI: Ion mobility spectrometry-Basic elements and applications; Int J Ion Mobil Spectrom 5:1; 2002.
    • (2002) Int J Ion Mobil Spectrom , vol.5 , pp. 1
    • Stach, J.1    Baumbach, J.I.2
  • 133
    • 23044480498 scopus 로고    scopus 로고
    • Detection of a chemical warfare agent simulant in various aerosol matrixes by ion mobility time-of-flight mass spectrometry
    • Steiner WE, Klopsch SJ, English W.A., Clowers BH, Hill HH: Detection of a chemical warfare agent simulant in various aerosol matrixes by ion mobility time-of-flight mass spectrometry; Anal Chem 77:4792; 2005.
    • (2005) Anal Chem , vol.77 , pp. 4792
    • Steiner, W.E.1    Klopsch, S.J.2    English, W.A.3    Clowers, B.H.4    Hill, H.H.5
  • 135
    • 80051751860 scopus 로고
    • Ion mobility spectrometry in analytical chemistry
    • St. Louis RH, Hill HH Jr: Ion mobility spectrometry in analytical chemistry; Crit Rev Anal Chem 21:321; 1990.
    • (1990) Crit Rev Anal Chem , vol.21 , pp. 321
    • St. Louis, R.H.1    Hill Jr., H.H.2
  • 136
    • 33645341715 scopus 로고    scopus 로고
    • Surface-enhanced raman spectroscopy of half mustard agent
    • Stuart DA, Biggs KB, Van Duyne BP: Surface-enhanced Raman spectroscopy of half mustard agent; Analyst 131:568; 2006.
    • (2006) Analyst , vol.131 , pp. 568
    • Stuart, D.A.1    Biggs, K.B.2    Van Duyne, B.P.3
  • 137
    • 84860527744 scopus 로고    scopus 로고
    • High-throughput walkthrough detection portal as a measure for counter terrorism: Design of a vapor sample for detecting triacetone triperoxide vapor by atmospheric-pressure chemical-ionization ion-trap mass spectrometry
    • Takada Y, Suzuki Y, Nagano H., Sugiyama M, Nakajima E, Sugaya M., Hashimoto Y, Sakairi M: High-throughput walkthrough detection portal as a measure for counter terrorism: Design of a vapor sample for detecting triacetone triperoxide vapor by atmospheric-pressure chemical-ionization ion-trap mass spectrometry; IEEE Sensor J 12:1673; 2012
    • (2012) IEEE Sensor J , vol.12 , pp. 1673
    • Takada, Y.1    Suzuki, Y.2    Nagano, H.3    Sugiyama, M.4    Nakajima, E.5    Sugaya, M.6    Hashimoto, Y.7    Sakairi, M.8
  • 138
    • 34250810696 scopus 로고    scopus 로고
    • Detection performance of draeger safety gas detection tubes for chemical warfare agents
    • Takayama Y, Sekioka R, Sekiguchi H, Maruko H, Ohmori T, Seto Y: Detection performance of Draeger Safety gas detection tubes for chemical warfare agents; Bunseki Kagaka 56:355; 2007.
    • (2007) Bunseki Kagaka , vol.56 , pp. 355
    • Takayama, Y.1    Sekioka, R.2    Sekiguchi, H.3    Maruko, H.4    Ohmori, T.5    Seto, Y.6
  • 140
    • 84856233001 scopus 로고    scopus 로고
    • Gas chromatography-full scan mass spectrometry determination of traces of chemical warfare agents and their impurities in air samples by inlet based thermal desorption of sorbent tubes
    • Terzic O, Swahn I, Cretu G., Palit M, Mallard G: Gas chromatography-full scan mass spectrometry determination of traces of chemical warfare agents and their impurities in air samples by inlet based thermal desorption of sorbent tubes; J Chromatogr A 1225:182; 2012.
    • (2012) J Chromatogr A , vol.1225 , pp. 182
    • Terzic, O.1    Swahn, I.2    Cretu, G.3    Palit, M.4    Mallard, G.5
  • 141
    • 84892612031 scopus 로고    scopus 로고
    • Torion Technologies Inc.: American Fork, UT Accessed March 15, 2013
    • TRIDION™-9 GC-TMS; Torion Technologies Inc.: American Fork, UT; http://www.torion.com/products/24 (Accessed March 15, 2013).
    • TRIDION™-9 GC-TMS
  • 143
    • 84892586234 scopus 로고    scopus 로고
    • Response to high levels of toxins and interference by colored sample matnx
    • Response to high levels of toxins and interference by colored sample matnx; Jpn J Forensic Toxicol 23:18; 2005.
    • (2005) Jpn J Forensic Toxicol , vol.23 , pp. 18
  • 144
    • 74549206034 scopus 로고    scopus 로고
    • Mass spectrometric identification of chemical warfare agent adducts with biological macromolecules for verification of their exposure
    • Tsuge K, Seto Y: Mass spectrometric identification of chemical warfare agent adducts with biological macromolecules for verification of their exposure; J Health Sci 55:879; 2009.
    • (2009) J Health Sci , vol.55 , pp. 879
    • Tsuge, K.1    Seto, Y.2
  • 145
    • 78449252130 scopus 로고    scopus 로고
    • Generation of fab fragment-like molecular recognition proteins against staphylococcal enterotoxin B by phage display technology
    • Urushibata Y, Ito K, Ohshima M., Seto Y: Generation of Fab fragment-like molecular recognition proteins against Staphylococcal enterotoxin B by phage display technology; Clin Vaccine Immunol 17:1708; 2010.
    • (2010) Clin Vaccine Immunol , vol.17 , pp. 1708
    • Urushibata, Y.1    Ito, K.2    Ohshima, M.3    Seto, Y.4
  • 146
    • 0038450319 scopus 로고    scopus 로고
    • Combining miniaturized ion mobility spectrometer and metal oxide gas sensor for the fast detection of toxic chemical vapors
    • Utriainen M, Karpanoja E, Paakkanen H: Combining miniaturized ion mobility spectrometer and metal oxide gas sensor for the fast detection of toxic chemical vapors; Sensor Actual B 93:17; 2003.
    • (2003) Sensor Actual B , vol.93 , pp. 17
    • Utriainen, M.1    Karpanoja, E.2    Paakkanen, H.3
  • 148
    • 84884747373 scopus 로고    scopus 로고
    • Laboratory analysis of chemical warfare agents and metabolites in biomedical samples
    • Gupta RC (Ed) Elsevier: Amsterdam, The Netherlands
    • Van der Schans MJ: Laboratory analysis of chemical warfare agents and metabolites In biomedical samples; In Gupta RC (Ed): Handbook of the Toxicology of Chemical Warfare Agents; Elsevier: Amsterdam, The Netherlands; pp 827-836; 2009.
    • (2009) Handbook of the Toxicology of Chemical Warfare Agents , pp. 827-836
    • Van Der Schans, M.J.1
  • 149
    • 84892577696 scopus 로고    scopus 로고
    • Smiths Detection: Watford, UK Accessed March 15, 2013
    • Vapor sampling-portable; Smiths Detection: Watford, UK; http://www.smithsdetection.com/portable-vapour-sampling.php (Accessed March 15, 2013).
    • Vapor Sampling-portable
  • 150
    • 0036210356 scopus 로고    scopus 로고
    • Microfluidic chips for clinical and forensic analysis
    • Verpoorte E: Microfluidic chips for clinical and forensic analysis; Electrophoresis 23:677; 2002.
    • (2002) Electrophoresis , vol.23 , pp. 677
    • Verpoorte, E.1
  • 152
    • 15444367187 scopus 로고    scopus 로고
    • Acetylcholinesterase-based organo-phosphate nerve agent sensing photonic crystal
    • Walker JP, Asher S A: Acetylcholinesterase-based organo-phosphate nerve agent sensing photonic crystal; Anal Chem 77:1596; 2005.
    • (2005) Anal Chem , vol.77 , pp. 1596
    • Walker, J.P.1    Asher, S.A.2
  • 153
    • 0034535139 scopus 로고    scopus 로고
    • Biological warfare detection
    • Walt DR, Franz DR: Biological warfare detection; Anal Chem 72:738A; 2000.
    • (2000) Anal Chem , vol.72
    • Walt, D.R.1    Franz, D.R.2
  • 154
    • 1242328940 scopus 로고    scopus 로고
    • Microchip devices for detecting terrorist weapons
    • Wang J: Microchip devices for detecting terrorist weapons; Anal Chim Acta 507:3; 2004.
    • (2004) Anal Chim Acta , vol.507 , pp. 3
    • Wang, J.1
  • 155
    • 0033463989 scopus 로고    scopus 로고
    • Rapid identification of nerve agents sarin (HB) and soman (GD) with the use of a field-portable GC/SAW vapor detector and liquid desorption front-end device
    • Williams D, Pappas G: Rapid identification of nerve agents sarin (HB) and soman (GD) with the use of a field-portable GC/SAW vapor detector and liquid desorption front-end device; Field Anal Chem Technol 3:45; 1999.
    • (1999) Field Anal Chem Technol , vol.3 , pp. 45
    • Williams, D.1    Pappas, G.2
  • 156
    • 1542502253 scopus 로고    scopus 로고
    • Direct sampling MS for environmental screening
    • Wise MB, Guerin MR: Direct sampling MS for environmental screening; Anal Chem 69:26A; 1997.
    • (1997) Anal Chem , vol.69
    • Wise, M.B.1    Guerin, M.R.2
  • 157
    • 0025218775 scopus 로고
    • Chromatographic analysis of chemical warfare agents
    • Witkiewicz Z, Mazurek M, Szulc J: Chromatographic analysis of chemical warfare agents; J Chromatogr 503:293; 1990.
    • (1990) J Chromatogr , vol.503 , pp. 293
    • Witkiewicz, Z.1    Mazurek, M.2    Szulc, J.3
  • 160
    • 0346994909 scopus 로고    scopus 로고
    • Probing photoelectrochemical processes in au-cds nanoparticle arrays by surface plasmon resonance: Application for the detection of acetylcholine esterase inhibitors
    • Zayats M, Kharitonov AB, Pogorelova S.P., Lioubashevski O., Katz E, Willner I: Probing photoelectrochemical processes in Au-CdS nanoparticle arrays by surface plasmon resonance: Application for the detection of acetylcholine esterase inhibitors; J Am Chem Soc 125:16006; 2003.
    • (2003) J Am Chem Soc , vol.125 , pp. 16006
    • Zayats, M.1    Kharitonov, A.B.2    Pogorelova, S.P.3    Lioubashevski, O.4    Katz, E.5    Willner, I.6
  • 161
    • 0037467426 scopus 로고    scopus 로고
    • Fluorescent detection of chemical warfare agents: Functional group specific ratiometric chemosensors
    • Zhang SW, SwagerTM: Fluorescent detection of chemical warfare agents: Functional group specific ratiometric chemosensors; J Am Chem Soc 125:3420; 2003.
    • (2003) J Am Chem Soc , vol.125 , pp. 3420
    • Zhang, S.W.1    Swager, T.M.2
  • 162
    • 34447642316 scopus 로고    scopus 로고
    • An ion-focusing aspiration condenser as an ion mobility spectrometer
    • Zimmermann S, Abel N, Baether W., Barth S: An ion-focusing aspiration condenser as an ion mobility spectrometer; Sensor Actual B 125:428; 2007.
    • (2007) Sensor Actual B , vol.125 , pp. 428
    • Zimmermann, S.1    Abel, N.2    Baether, W.3    Barth, S.4
  • 163
    • 51549112969 scopus 로고    scopus 로고
    • Miniaturized low-cost ion mobility spectrometer for fast detection of chemical warfare
    • Zimmermann S, Barth S, Baether WKM, Ringer J: Miniaturized low-cost ion mobility spectrometer for fast detection of chemical warfare agents; Anal Chem 80:6671; 2008.
    • (2008) Agents; Anal Chem , vol.80 , pp. 6671
    • Zimmermann, S.1    Barth, S.2    Baether, W.K.M.3    Ringer, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.