메뉴 건너뛰기




Volumn 71, Issue 2, 2014, Pages 735-745

High speed 3D overhauser-enhanced MRI using combined b-SSFP and compressed sensing

Author keywords

3D Overhauser MRI; b SSFP; compressed sensing; EPR; free radicals

Indexed keywords

BIOLOGY; COMPRESSED SENSING; ELECTRON RESONANCE; FREE RADICALS; PARAMAGNETIC RESONANCE;

EID: 84892436324     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24705     Document Type: Article
Times cited : (38)

References (54)
  • 2
    • 0036330723 scopus 로고    scopus 로고
    • Endotoxin-induced liver hypoxia: Defective oxygen delivery versus oxygen consumption
    • James PE, Madhani M, Roebuck W, Jackson SK, Swartz HM,. Endotoxin-induced liver hypoxia: defective oxygen delivery versus oxygen consumption. Nitric Oxide 2002; 6: 18-28.
    • (2002) Nitric Oxide , vol.6 , pp. 18-28
    • James, P.E.1    Madhani, M.2    Roebuck, W.3    Jackson, S.K.4    Swartz, H.M.5
  • 3
    • 79954589556 scopus 로고    scopus 로고
    • Multiparametric imaging of tumor oxygenation, redox status, and anatomical structure using overhauser-enhanced MRI-prepolarized MRI system
    • Ahn KH, Scott G, Stang P, Conolly S, Hristov D,. Multiparametric imaging of tumor oxygenation, redox status, and anatomical structure using overhauser-enhanced MRI-prepolarized MRI system. Magn Reson Med 2011; 65: 1416-1422.
    • (2011) Magn Reson Med , vol.65 , pp. 1416-1422
    • Ahn, K.H.1    Scott, G.2    Stang, P.3    Conolly, S.4    Hristov, D.5
  • 9
    • 0033571683 scopus 로고    scopus 로고
    • Diminished aqueous microviscosity of tumors in murine models measured with in vivo radiofrequency electron paramagnetic resonance
    • Halpern HJ, Chandramouli GV, Barth ED, Yu C, Peric M, Grdina DJ, Teicher BA., Diminished aqueous microviscosity of tumors in murine models measured with in vivo radiofrequency electron paramagnetic resonance. Cancer Res 1999; 59: 5836-5841.
    • (1999) Cancer Res , vol.59 , pp. 5836-5841
    • Halpern, H.J.1    Chandramouli, G.V.2    Barth, E.D.3    Yu, C.4    Peric, M.5    Grdina, D.J.6    Teicher, B.A.7
  • 10
    • 33845980604 scopus 로고    scopus 로고
    • Enhanced Overhauser contrast in proton-electron double-resonance imaging of the formation of an alginate hydrogel
    • Barros W, Engelsberg M,. Enhanced Overhauser contrast in proton-electron double-resonance imaging of the formation of an alginate hydrogel. J Magn Reson 2007; 184: 101-107.
    • (2007) J Magn Reson , vol.184 , pp. 101-107
    • Barros, W.1    Engelsberg, M.2
  • 12
    • 4644288678 scopus 로고    scopus 로고
    • Principles of imaging
    • Berliner L.J. editor. In vivo EPR (ESR): theory and applications. New York: Kluwer Academic/Plenum Publishers;. p
    • Kuppusamy P, Chzhan M, Zweier J,. Principles of imaging. In:, Berliner LJ, editor. Biological magnetic resonance, Vol. 18. In vivo EPR (ESR): theory and applications. New York: Kluwer Academic/Plenum Publishers; 2003. p 99-152.
    • (2003) Biological Magnetic Resonance , vol.18 , pp. 99-152
    • Kuppusamy, P.1    Chzhan, M.2    Zweier, J.3
  • 13
    • 0029665027 scopus 로고    scopus 로고
    • Measurement of differences in pO2 in response to perfluorocarbon/carbogen in FSa and NFSa murine fibrosarcomas with low-frequency electron paramagnetic resonance oximetry
    • Halpern HJ, Yu C, Peric M, Barth ED, Karczmar GS, River JN, Grdina DJ, Teicher BA,. Measurement of differences in pO2 in response to perfluorocarbon/carbogen in FSa and NFSa murine fibrosarcomas with low-frequency electron paramagnetic resonance oximetry. Radiat Res 1996; 145: 610-618.
    • (1996) Radiat Res , vol.145 , pp. 610-618
    • Halpern, H.J.1    Yu, C.2    Peric, M.3    Barth, E.D.4    Karczmar, G.S.5    River, J.N.6    Grdina, D.J.7    Teicher, B.A.8
  • 16
    • 0038440678 scopus 로고    scopus 로고
    • Mapping ischemic risk region and necrosis in the isolated heart using EPR imaging
    • Velayutham M, Li H, Kuppusamy P, Zweier JL,. Mapping ischemic risk region and necrosis in the isolated heart using EPR imaging. Magn Reson Med 2003; 49: 1181-1187.
    • (2003) Magn Reson Med , vol.49 , pp. 1181-1187
    • Velayutham, M.1    Li, H.2    Kuppusamy, P.3    Zweier, J.L.4
  • 17
    • 4243248912 scopus 로고    scopus 로고
    • In vivo imaging of free radicals: Applications from mouse to man
    • He G, Samouilov A, Kuppusamy P, Zweier JL,. In vivo imaging of free radicals: applications from mouse to man. Mol Cell Biochem 2002; 234/235: 359-367.
    • (2002) Mol Cell Biochem , vol.234 , pp. 359-367
    • He, G.1    Samouilov, A.2    Kuppusamy, P.3    Zweier, J.L.4
  • 18
    • 0000473242 scopus 로고
    • Proton-electron double magnetic resonance imaging of free radical solutions
    • Lurie DJ, Bussell DM, Bell LH, Mallard JR,. Proton-electron double magnetic resonance imaging of free radical solutions. J Magn Reson 1988; 76: 366-370.
    • (1988) J Magn Reson , vol.76 , pp. 366-370
    • Lurie, D.J.1    Bussell, D.M.2    Bell, L.H.3    Mallard, J.R.4
  • 20
    • 0037133314 scopus 로고    scopus 로고
    • Overhauser enhanced magnetic resonator imaging for tumor oximetry: Coregistration of tumor anatomy and tissue oxygen concentration
    • Krishna MC, English S, Yamada K, et al. Overhauser enhanced magnetic resonator imaging for tumor oximetry: coregistration of tumor anatomy and tissue oxygen concentration. Proc Natl Acad Sci USA 2002; 99: 2216-2221.
    • (2002) Proc Natl Acad Sci USA , vol.99 , pp. 2216-2221
    • Krishna, M.C.1    English, S.2    Yamada, K.3
  • 21
    • 31944445310 scopus 로고    scopus 로고
    • Simultaneous molecular imaging of redox reactions monitored by Overhauser-enhanced MRI with 14N- and 15N-labeled nitroxyl radicals
    • Utsumi H, Yamada K-I, Ichikawa K, Sakai K, Kinoshita Y, Matsumoto S, Nagai M,. Simultaneous molecular imaging of redox reactions monitored by Overhauser-enhanced MRI with 14N- and 15N-labeled nitroxyl radicals. Proc Natl Acad Sci USA 2006; 103: 1463-1468.
    • (2006) Proc Natl Acad Sci USA , vol.103 , pp. 1463-1468
    • Utsumi, H.1    Yamada, K.-I.2    Ichikawa, K.3    Sakai, K.4    Kinoshita, Y.5    Matsumoto, S.6    Nagai, M.7
  • 22
    • 33644807286 scopus 로고    scopus 로고
    • In vivo proton electron double resonance imaging of the distribution and clearance of nitroxide radicals in mice
    • Li H, He G, Deng Y, Kuppusamy P, Zweier JL,. In vivo proton electron double resonance imaging of the distribution and clearance of nitroxide radicals in mice. Magn Reson Med 2006; 55: 669-675.
    • (2006) Magn Reson Med , vol.55 , pp. 669-675
    • Li, H.1    He, G.2    Deng, Y.3    Kuppusamy, P.4    Zweier, J.L.5
  • 23
    • 33749073814 scopus 로고    scopus 로고
    • Dynamic nuclear polarization properties of nitroxyl radicals used in Overhauser-enhanced MRI for simultaneous molecular imaging
    • Benial AM, Ichikawa K, Murugesan R, Yamada K, Utsumi H,. Dynamic nuclear polarization properties of nitroxyl radicals used in Overhauser-enhanced MRI for simultaneous molecular imaging. J Magn Reson 2006; 182: 273-282.
    • (2006) J Magn Reson , vol.182 , pp. 273-282
    • Benial, A.M.1    Ichikawa, K.2    Murugesan, R.3    Yamada, K.4    Utsumi, H.5
  • 24
    • 84863040530 scopus 로고    scopus 로고
    • In vivo proton electron double resonance imaging of mice with fast spin echo pulse sequence
    • Sun Z, Li H, Petryakov S, Samouilov A, Zweier JL,. In vivo proton electron double resonance imaging of mice with fast spin echo pulse sequence. J Magn Reson Imaging 2012; 35: 471-475.
    • (2012) J Magn Reson Imaging , vol.35 , pp. 471-475
    • Sun, Z.1    Li, H.2    Petryakov, S.3    Samouilov, A.4    Zweier, J.L.5
  • 25
    • 0037035298 scopus 로고    scopus 로고
    • Rapid imaging of free radicals in vivo using hybrid FISP field-cycled PEDRI
    • Youngdee W, Lurie DJ, Foster MA,. Rapid imaging of free radicals in vivo using hybrid FISP field-cycled PEDRI. Phys Med Biol 2002; 47: 1091-1100.
    • (2002) Phys Med Biol , vol.47 , pp. 1091-1100
    • Youngdee, W.1    Lurie, D.J.2    Foster, M.A.3
  • 26
    • 47549111310 scopus 로고    scopus 로고
    • An open-access, very-low-field MRI system for posture-dependent 3He human lung imaging
    • Tsai LL, Mair RW, Rosen MS, Patz S, Walsworth RL,. An open-access, very-low-field MRI system for posture-dependent 3He human lung imaging. J Magn Reson 2008; 193: 274-285.
    • (2008) J Magn Reson , vol.193 , pp. 274-285
    • Tsai, L.L.1    Mair, R.W.2    Rosen, M.S.3    Patz, S.4    Walsworth, R.L.5
  • 27
    • 85012754454 scopus 로고
    • Dynamic nuclear polarization in liquids
    • Hausser KH, Stehlik D,. Dynamic nuclear polarization in liquids. Adv Magn Reson 1968; 3: 79-139.
    • (1968) Adv Magn Reson , vol.3 , pp. 79-139
    • Hausser, K.H.1    Stehlik, D.2
  • 28
    • 84988117910 scopus 로고
    • Molecular motions and interactions as studied by dynamic nuclear polarization (DNP) in free radical solutions
    • Muller-Warmuth W, Meise-Gresch K,. Molecular motions and interactions as studied by dynamic nuclear polarization (DNP) in free radical solutions. Adv Magn Reson 1983; 11: 1-45.
    • (1983) Adv Magn Reson , vol.11 , pp. 1-45
    • Muller-Warmuth, W.1    Meise-Gresch, K.2
  • 29
    • 0000504594 scopus 로고
    • An efficient decoupler coil design which reduces heating in conductive samples in superconducting spectrometers
    • Alderman DW, Grant DM,. An efficient decoupler coil design which reduces heating in conductive samples in superconducting spectrometers. J Magn Reson 1979; 36: 447-451.
    • (1979) J Magn Reson , vol.36 , pp. 447-451
    • Alderman, D.W.1    Grant, D.M.2
  • 30
    • 0036136996 scopus 로고    scopus 로고
    • Development of a PEDRI free-radical imager using a 0.38 T clinical MRI system
    • Lurie DJ, Li H, Petryakov S, Zweier JL,. Development of a PEDRI free-radical imager using a 0.38 T clinical MRI system. Magn Reson Med 2002; 47: 181-186.
    • (2002) Magn Reson Med , vol.47 , pp. 181-186
    • Lurie, D.J.1    Li, H.2    Petryakov, S.3    Zweier, J.L.4
  • 32
    • 0018190215 scopus 로고
    • RF magnetic field penetration, phase shift and power dissipation in biological tissue: Implications for NMR imaging
    • Bottomley PA, Andrew ER,. RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imaging. Phys Med Biol 1978; 23: 630-643.
    • (1978) Phys Med Biol , vol.23 , pp. 630-643
    • Bottomley, P.A.1    Andrew, E.R.2
  • 34
    • 0032252606 scopus 로고    scopus 로고
    • SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil. Specific energy absorption rate
    • Collins CM, Li S, Smith MB,. SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil. Specific energy absorption rate. Magn Reson Med 1998; 40: 847-856.
    • (1998) Magn Reson Med , vol.40 , pp. 847-856
    • Collins, C.M.1    Li, S.2    Smith, M.B.3
  • 35
    • 0035088714 scopus 로고    scopus 로고
    • Calculations of B(1) distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model
    • Collins CMC, Smith MBM,. Calculations of B(1) distribution, SNR, and SAR for a surface coil adjacent to an anatomically-accurate human body model. Magn Reson Med 2001; 45: 692-699.
    • (2001) Magn Reson Med , vol.45 , pp. 692-699
    • Collins, C.M.C.1    Smith, M.B.M.2
  • 36
    • 79954774065 scopus 로고    scopus 로고
    • Calculation of radiofrequency electromagnetic fields and their effects in MRI of human subjects
    • Collins CM, Wang Z,. Calculation of radiofrequency electromagnetic fields and their effects in MRI of human subjects. Magn Reson Med 2011; 65: 1470-1482.
    • (2011) Magn Reson Med , vol.65 , pp. 1470-1482
    • Collins, C.M.1    Wang, Z.2
  • 37
    • 0242439328 scopus 로고    scopus 로고
    • Principles and applications of balanced SSFP techniques
    • Scheffler K, Lehnhardt S,. Principles and applications of balanced SSFP techniques. Eur Radiol 2003; 13: 2409-2418.
    • (2003) Eur Radiol , vol.13 , pp. 2409-2418
    • Scheffler, K.1    Lehnhardt, S.2
  • 38
    • 31744440684 scopus 로고    scopus 로고
    • Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information
    • Candes EJ, Romberg J, Tao T,. Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information. IEEE Trans Inform Theory 2006; 52: 489-509.
    • (2006) IEEE Trans Inform Theory , vol.52 , pp. 489-509
    • Candes, E.J.1    Romberg, J.2    Tao, T.3
  • 40
  • 41
    • 44049111982 scopus 로고
    • Nonlinear total variation based noise removal algorithms
    • Rudin LI, Osher S, Fatemi E,. Nonlinear total variation based noise removal algorithms. Phys D: Nonlinear Phenom 1992; 60: 259-268.
    • (1992) Phys D: Nonlinear Phenom , vol.60 , pp. 259-268
    • Rudin, L.I.1    Osher, S.2    Fatemi, E.3
  • 42
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • Lustig M, Donoho D, Pauly JM,. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 2007; 58: 1182-1195.
    • (2007) Magn Reson Med , vol.58 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 44
    • 73349094324 scopus 로고    scopus 로고
    • Experimental and numerical assessment of MRI-induced temperature change and SAR distributions in phantoms and in vivo
    • Oh S, Webb AG, Neuberger T, Park B, Collins CM,. Experimental and numerical assessment of MRI-induced temperature change and SAR distributions in phantoms and in vivo. Magn Reson Med 2010; 63: 218-223.
    • (2010) Magn Reson Med , vol.63 , pp. 218-223
    • Oh, S.1    Webb, A.G.2    Neuberger, T.3    Park, B.4    Collins, C.M.5
  • 46
    • 0032785047 scopus 로고    scopus 로고
    • Rapid imaging of free radicals in vivo using field cycled PEDRI
    • Puwanich P, Lurie DJ, Foster MA,. Rapid imaging of free radicals in vivo using field cycled PEDRI. Phys Med Biol 1999; 44: 2867-2877.
    • (1999) Phys Med Biol , vol.44 , pp. 2867-2877
    • Puwanich, P.1    Lurie, D.J.2    Foster, M.A.3
  • 47
    • 32544443428 scopus 로고    scopus 로고
    • Faster imaging with randomly perturbed, undersampled spirals and L1 reconstruction
    • Miami Beach, Florida, USA
    • Lustig M, Lee J, Donoho D, Pauly J,. Faster imaging with randomly perturbed, undersampled spirals and L1 reconstruction. In Proceedings of the 13th Annual Meeting of ISMRM, Miami Beach, Florida, USA, 2005. p. 155.
    • (2005) Proceedings of the 13th Annual Meeting of ISMRM , pp. 155
    • Lustig, M.1    Lee, J.2    Donoho, D.3    Pauly, J.4
  • 49
    • 34248396720 scopus 로고    scopus 로고
    • Projection reconstruction MR imaging using FOCUSS
    • Ye JC, Tak S, Han Y, Park HW,. Projection reconstruction MR imaging using FOCUSS. Magn Reson Med 2007; 57: 764-775.
    • (2007) Magn Reson Med , vol.57 , pp. 764-775
    • Ye, J.C.1    Tak, S.2    Han, Y.3    Park, H.W.4
  • 50
    • 34250320137 scopus 로고    scopus 로고
    • Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint
    • Block KT, Uecker M, Frahm J,. Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint. Magn Reson Med 2007; 57: 1086-1098.
    • (2007) Magn Reson Med , vol.57 , pp. 1086-1098
    • Block, K.T.1    Uecker, M.2    Frahm, J.3
  • 52
    • 38849164794 scopus 로고    scopus 로고
    • Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets
    • Chen G-H, Tang J, Leng S,. Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. Med Phys 2008; 35: 660-663.
    • (2008) Med Phys , vol.35 , pp. 660-663
    • Chen, G.-H.1    Tang, J.2    Leng, S.3
  • 53
    • 84855425876 scopus 로고    scopus 로고
    • Prior image constrained compressed sensing: Implementation and performance evaluation
    • Lauzier PT, Tang J, Chen G-H,. Prior image constrained compressed sensing: implementation and performance evaluation. Med Phys 2012; 39: 66-80.
    • (2012) Med Phys , vol.39 , pp. 66-80
    • Lauzier, P.T.1    Tang, J.2    Chen, G.-H.3
  • 54
    • 0021126494 scopus 로고
    • Determination of blood volume in the mouse with 51Chromium-labelled erythrocytes
    • Sluiter W, Oomens LWM, Brand A, Van Furth R,. Determination of blood volume in the mouse with 51Chromium-labelled erythrocytes. J Immunol Methods 1984; 73: 221-225.
    • (1984) J Immunol Methods , vol.73 , pp. 221-225
    • Sluiter, W.1    Oomens, L.W.M.2    Brand, A.3    Van Furth, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.