-
1
-
-
56549094092
-
A rapid method for prototyping paper-based microfluidic devices
-
A.W. Martinez, S.T. Phillips, B.J. Wiley, M. Gupta, and G.M. Whitesides A rapid method for prototyping paper-based microfluidic devices Lab on a Chip 8 2008 2146 2150
-
(2008)
Lab on A Chip
, vol.8
, pp. 2146-2150
-
-
Martinez, A.W.1
Phillips, S.T.2
Wiley, B.J.3
Gupta, M.4
Whitesides, G.M.5
-
2
-
-
42949095976
-
Low-cost printing of poly(dimethylsiloxane) barriers to define microchannels in paper
-
DOI 10.1021/ac702605a
-
D.A. Bruzewicz, M. Reches, and G.M. Whitesides Low-cost printing of poly(dimethylsiloxane) barriers to define microchannels in paper Analytical Chemistry 80 2008 3387 3392 (Pubitemid 351620725)
-
(2008)
Analytical Chemistry
, vol.80
, Issue.9
, pp. 3387-3392
-
-
Bruzewicz, D.A.1
Reches, M.2
Whitesides, G.M.3
-
3
-
-
51949106700
-
Inkjet-printed microfluidic multianalyte chemical sensing paper
-
K. Abe, K. Suzuki, and D. Citterio Inkjet-printed microfluidic multianalyte chemical sensing paper Analytical Chemistry 80 2008 6928 6934
-
(2008)
Analytical Chemistry
, vol.80
, pp. 6928-6934
-
-
Abe, K.1
Suzuki, K.2
Citterio, D.3
-
4
-
-
68849107869
-
Understanding wax printing: A simple micropatterning process for paper-based microfluidics
-
E. Carrilho, A.W. Martinez, and G.M. Whitesides Understanding wax printing: a simple micropatterning process for paper-based microfluidics Analytical Chemistry 81 2008 7091 7095
-
(2008)
Analytical Chemistry
, vol.81
, pp. 7091-7095
-
-
Carrilho, E.1
Martinez, A.W.2
Whitesides, G.M.3
-
5
-
-
75749111702
-
Fabrication and characterization of paper-based microfluidics prepared in nitrocellulose membrane by wax printing
-
Y. Lu, W. Shi, J. Qin, and B. Lin Fabrication and characterization of paper-based microfluidics prepared in nitrocellulose membrane by wax printing Analytical Chemistry 82 2009 329 335
-
(2009)
Analytical Chemistry
, vol.82
, pp. 329-335
-
-
Lu, Y.1
Shi, W.2
Qin, J.3
Lin, B.4
-
6
-
-
57449121168
-
Paper-based microfluidic devices by plasma treatment
-
X. Li, J. Tian, T. Nguyen, and W. Shen Paper-based microfluidic devices by plasma treatment Analytical Chemistry 80 2008 9131 9134
-
(2008)
Analytical Chemistry
, vol.80
, pp. 9131-9134
-
-
Li, X.1
Tian, J.2
Nguyen, T.3
Shen, W.4
-
7
-
-
79952177518
-
Laser-treated hydrophobic paper: An inexpensive microfluidic platform
-
G. Chitnis, Z. Ding, C.L. Chang, C.A. Savran, and B. Ziaie Laser-treated hydrophobic paper: an inexpensive microfluidic platform Lab on a Chip 11 2011 1161 1165
-
(2011)
Lab on A Chip
, vol.11
, pp. 1161-1165
-
-
Chitnis, G.1
Ding, Z.2
Chang, C.L.3
Savran, C.A.4
Ziaie, B.5
-
9
-
-
34247273993
-
Patterned paper as a platform for inexpensive, low-volume, portable bioassays
-
DOI 10.1002/anie.200603817
-
A.W. Martinez, S.T. Phillips, M.J. Butte, and G.M. Whitesides Patterned paper as a platform for inexpensive, low-volume, portable bioassays Angewandte Chemie International Edition 46 2007 1318 1320 (Pubitemid 46981385)
-
(2007)
Angewandte Chemie - International Edition
, vol.46
, Issue.8
, pp. 1318-1320
-
-
Martinez, A.W.1
Phillips, S.T.2
Butte, M.J.3
Whitesides, G.M.4
-
10
-
-
43949138608
-
Simple telemedicine for developing regions: Camera phones and paper-based microfluidic devices for real-time, off-site diagnosis
-
DOI 10.1021/ac800112r
-
A.W. Martinez, S.T. Phillips, E. Carrilho, S.W. Thomas, H. Sindi, and G.M. Whitesides Simple telemedicine for developing regions: camera phones and paper-based microfluidic devices for real-time, off-site diagnosis Analytical Chemistry 80 2008 3699 3707 (Pubitemid 351705870)
-
(2008)
Analytical Chemistry
, vol.80
, Issue.10
, pp. 3699-3707
-
-
Martinez, A.W.1
Phillips, S.T.2
Carrilho, E.3
Thomas III, S.W.4
Sindi, H.5
Whitesides, G.M.6
-
12
-
-
75749111702
-
Cheap biomedical devices based on nitrocellulose and wax
-
Y. Lu, W. Shi, J. Qin, and B. Lin Cheap biomedical devices based on nitrocellulose and wax Analytical Chemistry 82 2010 329 335
-
(2010)
Analytical Chemistry
, vol.82
, pp. 329-335
-
-
Lu, Y.1
Shi, W.2
Qin, J.3
Lin, B.4
-
13
-
-
84859621676
-
Paper-based electrochemiluminescent 3D immunodevice for lab-on-paper, specific, and sensitive point-of-care testing
-
J.X. Yan, L. Ge, X.R. Song, M. Yan, S.G. Ge, and J.H. Yu Paper-based electrochemiluminescent 3D immunodevice for lab-on-paper, specific, and sensitive point-of-care testing Chemistry - A European Journal 18 2012 4938 4945
-
(2012)
Chemistry - A European Journal
, vol.18
, pp. 4938-4945
-
-
Yan, J.X.1
Ge, L.2
Song, X.R.3
Yan, M.4
Ge, S.G.5
Yu, J.H.6
-
14
-
-
81355161670
-
Three-dimensional paper-based electrochemiluminescence immunodevice for multiplexed measurement of biomarkers and point-of-care testing
-
L. Ge, J.X. Yan, X.R. Song, M. Yan, S.G. Ge, and J.H. Yu Three-dimensional paper-based electrochemiluminescence immunodevice for multiplexed measurement of biomarkers and point-of-care testing Biomaterials 33 2012 1024 1031
-
(2012)
Biomaterials
, vol.33
, pp. 1024-1031
-
-
Ge, L.1
Yan, J.X.2
Song, X.R.3
Yan, M.4
Ge, S.G.5
Yu, J.H.6
-
15
-
-
84859959638
-
Electrochemical immunoassay on a 3D microfluidic paper-based device
-
D.J. Zang, L. Ge, M. Yan, X.R. Song, and J.H. Yu Electrochemical immunoassay on a 3D microfluidic paper-based device Chemical Communications 48 2012 4683 4685
-
(2012)
Chemical Communications
, vol.48
, pp. 4683-4685
-
-
Zang, D.J.1
Ge, L.2
Yan, M.3
Song, X.R.4
Yu, J.H.5
-
16
-
-
84863380680
-
Quantum dot (QD)-modified carbon tape electrodes for reproducible electrochemiluminescence (ECL) emission on a paper-based platform
-
C.G. Shi, X. Shan, Z.Q. Pan, J.J. Xu, C. Lu, and N. Bao Quantum dot (QD)-modified carbon tape electrodes for reproducible electrochemiluminescence (ECL) emission on a paper-based platform Analytical Chemistry 84 2012 3033 3038
-
(2012)
Analytical Chemistry
, vol.84
, pp. 3033-3038
-
-
Shi, C.G.1
Shan, X.2
Pan, Z.Q.3
Xu, J.J.4
Lu, C.5
Bao, N.6
-
17
-
-
84866375888
-
Rechargeable battery-triggered electrochemiluminescence detection on microfluidic origami immunodevice based on two electrodes
-
S. Wang, W. Dai, L. Ge, M. Yan, J. Yu, and X. Song Rechargeable battery-triggered electrochemiluminescence detection on microfluidic origami immunodevice based on two electrodes Chemical Communications 48 2012 9971 9973
-
(2012)
Chemical Communications
, vol.48
, pp. 9971-9973
-
-
Wang, S.1
Dai, W.2
Ge, L.3
Yan, M.4
Yu, J.5
Song, X.6
-
18
-
-
84867294058
-
Battery-triggered microfluidic paper-based multiplex electrochemiluminescence immunodevice based on potential-resolution strategy
-
S. Wang, L. Ge, Y. Zhang, X. Song, N. Li, and S. Ge Battery-triggered microfluidic paper-based multiplex electrochemiluminescence immunodevice based on potential-resolution strategy Lab on a Chip 12 2012 4489 4498
-
(2012)
Lab on A Chip
, vol.12
, pp. 4489-4498
-
-
Wang, S.1
Ge, L.2
Zhang, Y.3
Song, X.4
Li, N.5
Ge, S.6
-
19
-
-
0037830049
-
Recent applications of electrogenerated chemiluminescence in chemical analysis
-
DOI 10.1016/S0039-9140(01)00312-5, PII S0039914001003125
-
K.A. Fahnrich, M. Pravda, and G.G. Guibault Recent applications of electrogenerated chemiluminescence in chemical analysis Talanta 54 2001 531 559 (Pubitemid 32463299)
-
(2001)
Talanta
, vol.54
, Issue.4
, pp. 531-559
-
-
Fahnrich, K.A.1
Pravda, M.2
Guilbault, G.G.3
-
20
-
-
4344562115
-
Electrochemiluminescence (ECL)
-
M.M. Richter Electrochemiluminescence (ECL) Chemical Reviews 104 2004 3003 3036
-
(2004)
Chemical Reviews
, vol.104
, pp. 3003-3036
-
-
Richter, M.M.1
-
21
-
-
3242679119
-
Analytical applications of the electrochemiluminescence of tris (2,2′-bipyridyl) ruthenium and its derivatives
-
X.B. Yin, S.J. Dong, and E.K. Wang Analytical applications of the electrochemiluminescence of tris (2,2′-bipyridyl) ruthenium and its derivatives TrAC - Trends in Analytical Chemistry 23 2004 432 441
-
(2004)
TrAC - Trends in Analytical Chemistry
, vol.23
, pp. 432-441
-
-
Yin, X.B.1
Dong, S.J.2
Wang, E.K.3
-
22
-
-
33745745613
-
Tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence
-
B.A. Gorman, P.S. Francis, and N.W. Barnett Tris(2,2′-bipyridyl) ruthenium(II) chemiluminescence Analyst 131 2006 616 639
-
(2006)
Analyst
, vol.131
, pp. 616-639
-
-
Gorman, B.A.1
Francis, P.S.2
Barnett, N.W.3
-
23
-
-
80052961711
-
An integrated sensing system for detection of DNA using new parallel-motif DNA triplex system and graphene-mesoporous silica-gold nanoparticle hybrids
-
Y. Du, S. Guo, S. Dong, and E. Wang An integrated sensing system for detection of DNA using new parallel-motif DNA triplex system and graphene-mesoporous silica-gold nanoparticle hybrids Biomaterials 32 2011 8584 8592
-
(2011)
Biomaterials
, vol.32
, pp. 8584-8592
-
-
Du, Y.1
Guo, S.2
Dong, S.3
Wang, E.4
-
24
-
-
79959790149
-
Label-free regenerative and sensitive surface plasmon resonance and electrochemical aptasensors based on graphene
-
L. Wang, C. Zhu, L. Han, L. Jin, M. Zhou, and S. Dong Label-free regenerative and sensitive surface plasmon resonance and electrochemical aptasensors based on graphene Chemical Communications 47 2011 7794 7796
-
(2011)
Chemical Communications
, vol.47
, pp. 7794-7796
-
-
Wang, L.1
Zhu, C.2
Han, L.3
Jin, L.4
Zhou, M.5
Dong, S.6
-
25
-
-
67650744584
-
A graphene-based fluorescent nanoprobe for silver(I) ions detection by using graphene oxide and a silver-specific oligonucleotide
-
M. Zhou, Y. Zhai, and S. Dong A graphene-based fluorescent nanoprobe for silver(I) ions detection by using graphene oxide and a silver-specific oligonucleotide Analytical Chemistry 81 2009 5603 5613
-
(2009)
Analytical Chemistry
, vol.81
, pp. 5603-5613
-
-
Zhou, M.1
Zhai, Y.2
Dong, S.3
-
26
-
-
77955523549
-
Platinum nanoparticle ensemble-on-graphene hybrid nanosheet: One-pot, rapid synthesis, and used as new electrode material for electrochemical sensing
-
S. Guo, D. Wen, S. Dong, and E. Wang Platinum nanoparticle ensemble-on-graphene hybrid nanosheet: one-pot, rapid synthesis, and used as new electrode material for electrochemical sensing ACS Nano 4 2010 3959 3968
-
(2010)
ACS Nano
, vol.4
, pp. 3959-3968
-
-
Guo, S.1
Wen, D.2
Dong, S.3
Wang, E.4
-
27
-
-
77950381659
-
Sensitive immunosensor for cancer biomarker based on dual signal amplification strategy of graphene sheets and multienzyme functionalized carbon nanospheres
-
D. Du, Z. Zou, Y. Shin, J. Wang, H. Wu, M.H. Engelhard, J. Liu, I.A. Aksay, and Y. Lin Sensitive immunosensor for cancer biomarker based on dual signal amplification strategy of graphene sheets and multienzyme functionalized carbon nanospheres Analytical Chemistry 82 2010 2989 2995
-
(2010)
Analytical Chemistry
, vol.82
, pp. 2989-2995
-
-
Du, D.1
Zou, Z.2
Shin, Y.3
Wang, J.4
Wu, H.5
Engelhard, M.H.6
Liu, J.7
Aksay, I.A.8
Lin, Y.9
-
28
-
-
79956106646
-
Positive potential operation of a cathodic electrogenerated chemiluminescence immunosensor based on luminol and graphene for cancer biomarker detection
-
S. Xu, Y. Liu, T. Wang, and J. Li Positive potential operation of a cathodic electrogenerated chemiluminescence immunosensor based on luminol and graphene for cancer biomarker detection Analytical Chemistry 83 2011 3817 3823
-
(2011)
Analytical Chemistry
, vol.83
, pp. 3817-3823
-
-
Xu, S.1
Liu, Y.2
Wang, T.3
Li, J.4
-
29
-
-
73249150156
-
Graphene oxide-amplified electrogenerated chemiluminescence of quantum dots and its selective sensing
-
Y. Wang, J. Lu, L. Tang, H. Chang, and J. Li Graphene oxide-amplified electrogenerated chemiluminescence of quantum dots and its selective sensing Analytical Chemistry 81 2009 9710 9715
-
(2009)
Analytical Chemistry
, vol.81
, pp. 9710-9715
-
-
Wang, Y.1
Lu, J.2
Tang, L.3
Chang, H.4
Li, J.5
-
30
-
-
76749150089
-
Graphene field-effect transistors with high on/off current ratio and large transport band gap at room temperature
-
F.N. Xia, D.B. Farmer, Y.M. Lin, and P. Avouris Graphene field-effect transistors with high on/off current ratio and large transport band gap at room temperature Nano Letters 10 2010 715 718
-
(2010)
Nano Letters
, vol.10
, pp. 715-718
-
-
Xia, F.N.1
Farmer, D.B.2
Lin, Y.M.3
Avouris, P.4
-
31
-
-
33847364563
-
The structure of suspended graphene sheets
-
DOI 10.1038/nature05545, PII NATURE05545
-
J.C. Meyer, A.K. Geim, M.I. Katsnelson, K.S. Novoselov, T.J. Booth, and S. Roth The structure of suspended graphene sheets Nature 446 2007 60 63 (Pubitemid 46348040)
-
(2007)
Nature
, vol.446
, Issue.7131
, pp. 60-63
-
-
Meyer, J.C.1
Geim, A.K.2
Katsnelson, M.I.3
Novoselov, K.S.4
Booth, T.J.5
Roth, S.6
-
32
-
-
84866482239
-
Electrogenerated chemiluminescence from a phenyleneethynylene derivative and its ultrasensitive immunosensing application using a nanotubular mesoporous Pt-Ag alloy for signal amplification
-
M. Yan, L. Ge, W. Gao, J. Yu, X. Song, and S. Ge Electrogenerated chemiluminescence from a phenyleneethynylene derivative and its ultrasensitive immunosensing application using a nanotubular mesoporous Pt-Ag alloy for signal amplification Advanced Functional Materials 22 2012 3899 3906
-
(2012)
Advanced Functional Materials
, vol.22
, pp. 3899-3906
-
-
Yan, M.1
Ge, L.2
Gao, W.3
Yu, J.4
Song, X.5
Ge, S.6
-
33
-
-
79960903512
-
Nanoporous PtAg and PtCu alloys with hollow ligaments for enhanced electrocatalysis and glucose biosensing
-
C. Xu, Y. Liu, F. Su, A. Liu, and H. Qiu Nanoporous PtAg and PtCu alloys with hollow ligaments for enhanced electrocatalysis and glucose biosensing Biosensors and Bioelectronics 27 2011 160 166
-
(2011)
Biosensors and Bioelectronics
, vol.27
, pp. 160-166
-
-
Xu, C.1
Liu, Y.2
Su, F.3
Liu, A.4
Qiu, H.5
-
34
-
-
84872716444
-
A microfluidic origami electrochemiluminescence aptamer-device based on a porous Au-paper electrode and a phenyleneethynylene derivative
-
J.X. Yan, M. Yan, L. Ge, J.H. Yu, S.G. Ge, and J.D. Huang A microfluidic origami electrochemiluminescence aptamer-device based on a porous Au-paper electrode and a phenyleneethynylene derivative Chemical Communications 49 2013 1383 1385
-
(2013)
Chemical Communications
, vol.49
, pp. 1383-1385
-
-
Yan, J.X.1
Yan, M.2
Ge, L.3
Yu, J.H.4
Ge, S.G.5
Huang, J.D.6
-
35
-
-
55649117540
-
Dispersion stability of single-walled carbon nanotubes using nafion in bisolvent
-
J. Zhang, L. Gao, J. Sun, Y.Q. Liu, Y. Wang, J.P. Wang, Y. Li, M. Kajiura, and K. Noda Dispersion stability of single-walled carbon nanotubes using nafion in bisolvent The Journal of Physical Chemistry C 112 2008 16370 16376
-
(2008)
The Journal of Physical Chemistry C
, vol.112
, pp. 16370-16376
-
-
Zhang, J.1
Gao, L.2
Sun, J.3
Liu, Y.Q.4
Wang, Y.5
Wang, J.P.6
Li, Y.7
Kajiura, M.8
Noda, K.9
-
36
-
-
77749302316
-
Lab-on-paper with dual electrochemical/colorimetric detection for simultaneous determination of gold and iron
-
A. Apilux, W. Dungchai, W. Siangproh, N. Praphairaksit, C.S. Henry, and O. Chailapakul Lab-on-paper with dual electrochemical/colorimetric detection for simultaneous determination of gold and iron Analytical Chemistry 82 2010 1727 1732
-
(2010)
Analytical Chemistry
, vol.82
, pp. 1727-1732
-
-
Apilux, A.1
Dungchai, W.2
Siangproh, W.3
Praphairaksit, N.4
Henry, C.S.5
Chailapakul, O.6
-
37
-
-
0037418378
-
An improved synthesis of high-aspect-ratio gold nanorods
-
B.D. Busbee, S.O. Obare, and C.J. Murphy An improved synthesis of high-aspect-ratio gold nanorods Advanced Materials 15 2003 414 416
-
(2003)
Advanced Materials
, vol.15
, pp. 414-416
-
-
Busbee, B.D.1
Obare, S.O.2
Murphy, C.J.3
-
38
-
-
84865267213
-
Electrochemical DNA sensor based on three-dimensional folding paper device for specific and sensitive point-of-care testing
-
J. Lu, S. Ge, L. Ge, M. Yan, and J. Yu Electrochemical DNA sensor based on three-dimensional folding paper device for specific and sensitive point-of-care testing Electrochimica Acta 80 2012 334 341
-
(2012)
Electrochimica Acta
, vol.80
, pp. 334-341
-
-
Lu, J.1
Ge, S.2
Ge, L.3
Yan, M.4
Yu, J.5
-
39
-
-
76149106152
-
Reverse-micelle synthesis of electrochemically encoded quantum dot barcodes: Application to electronic coding of a cancer marker
-
Y. Xiang, Y. Zhang, Y. Chang, Y. Chai, J. Wang, and R. Yuan Reverse-micelle synthesis of electrochemically encoded quantum dot barcodes: application to electronic coding of a cancer marker Analytical Chemistry 82 2010 1138 1141
-
(2010)
Analytical Chemistry
, vol.82
, pp. 1138-1141
-
-
Xiang, Y.1
Zhang, Y.2
Chang, Y.3
Chai, Y.4
Wang, J.5
Yuan, R.6
-
40
-
-
79952136831
-
Carcinoembryonic antigen admittance biosensor based on Au and ZnO nanoparticles using FFT admittance voltammetry
-
P. Norouzi, V.K. Gupta, F. Faridbod, M. Pirali-Hamedani, B. Larijani, and M.R. Ganjali Carcinoembryonic antigen admittance biosensor based on Au and ZnO nanoparticles using FFT admittance voltammetry Analytical Chemistry 83 2011 1564 1570
-
(2011)
Analytical Chemistry
, vol.83
, pp. 1564-1570
-
-
Norouzi, P.1
Gupta, V.K.2
Faridbod, F.3
Pirali-Hamedani, M.4
Larijani, B.5
Ganjali, M.R.6
-
41
-
-
80052342758
-
Simultaneous detection of dual proteins using quantum dots coated silica nanoparticles as labels
-
J. Qian, H. Dai, X. Pan, and S. Liu Simultaneous detection of dual proteins using quantum dots coated silica nanoparticles as labels Biosensors and Bioelectronics 28 2011 314 319
-
(2011)
Biosensors and Bioelectronics
, vol.28
, pp. 314-319
-
-
Qian, J.1
Dai, H.2
Pan, X.3
Liu, S.4
-
42
-
-
1542404812
-
Microfluidic enzyme immunosensors with immobilised protein a and G using chemiluminescence detection
-
DOI 10.1016/S0956-5663(03)00126-X, PII S095656630300126X
-
J. Yakovleva, R. Davidsson, M. Bengtsson, T. Laurell, and J. Emnus Microfluidic enzyme immunosensors with immobilised protein A and G using chemiluminescence detection Biosensors and Bioelectronics 19 2003 21 34 (Pubitemid 38340375)
-
(2003)
Biosensors and Bioelectronics
, vol.19
, Issue.1
, pp. 21-34
-
-
Yakovleva, J.1
Davidsson, R.2
Bengtsson, M.3
Laurell, T.4
Emneus, J.5
-
43
-
-
0036646094
-
Microfluidic enzyme immunoassay using silicon microchip with immobilized antibodies and chemiluminescence detection
-
DOI 10.1021/ac015645b
-
J. Yakovleva, R. Davidsson, A. Lobanova, M. Bengtsson, S. Eremin, T. Laurell, and J. Emnus Microfluidic enzyme immunoassay using silicon microchip with immobilized antibodies and chemiluminescence detection Analytical Chemistry 74 2002 2994 3004 (Pubitemid 34759949)
-
(2002)
Analytical Chemistry
, vol.74
, Issue.13
, pp. 2994-3004
-
-
Yakovleva, J.1
Davidsson, R.2
Lobanova, A.3
Bengtsson, M.4
Eremin, S.5
Laurell, T.6
Emneus, J.7
|