메뉴 건너뛰기




Volumn 33, Issue 4, 2012, Pages 1024-1031

Three-dimensional paper-based electrochemiluminescence immunodevice for multiplexed measurement of biomarkers and point-of-care testing

Author keywords

Biomarker; Electrochemiluminescence immunoassay; Lab on paper; Point of care testing; Screen printed electrode

Indexed keywords

AG/AGCL; BIPYRIDINES; CONDUCTIVE PADS; COUNTER ELECTRODES; DEVELOPED COUNTRIES; ELECTROCHEMILUMINESCENCE; ENVIRONMENTAL MONITORING; FURTHER DEVELOPMENT; HIGH-THROUGHPUT; N-PROPYLAMINE; PAPER ELECTRONICS; POINT-OF-CARE TESTING; PUBLIC HEALTH; REMOTE REGIONS; ROOM TEMPERATURE; SCREEN PRINTED ELECTRODES; SCREEN-PRINTED; SERUM SAMPLES; THREE-DIMENSIONAL (3D); TUMOR MARKERS; WORKING ELECTRODE;

EID: 81355161670     PISSN: 01429612     EISSN: 18785905     Source Type: Journal    
DOI: 10.1016/j.biomaterials.2011.10.065     Document Type: Article
Times cited : (344)

References (47)
  • 1
    • 26344455524 scopus 로고
    • Semiquantitative specific test paper for glucose in urine
    • Comer J.P. Semiquantitative specific test paper for glucose in urine. Anal Chem 1956, 28:1748-1750.
    • (1956) Anal Chem , vol.28 , pp. 1748-1750
    • Comer, J.P.1
  • 2
    • 34247273993 scopus 로고    scopus 로고
    • Patterned paper as a platform for inexpensive, low-volume, portable bioassays
    • Martinez A.W., Phillips S.T., Butte M.J., Whitesides G.M. Patterned paper as a platform for inexpensive, low-volume, portable bioassays. Angew Chem Int Ed 2007, 46:1318-1320.
    • (2007) Angew Chem Int Ed , vol.46 , pp. 1318-1320
    • Martinez, A.W.1    Phillips, S.T.2    Butte, M.J.3    Whitesides, G.M.4
  • 4
    • 79959233575 scopus 로고    scopus 로고
    • Cheap, handheld colorimeter to read paper-based diagnostic devices
    • Mukhopadhyay R. Cheap, handheld colorimeter to read paper-based diagnostic devices. Anal Chem 2009, 81:8659.
    • (2009) Anal Chem , vol.81 , pp. 8659
    • Mukhopadhyay, R.1
  • 5
    • 75749113741 scopus 로고    scopus 로고
    • Diagnostics for the developing world: microfluidic paper-based analytical devices
    • Martinez A.W., Phillips S.T., Whitesides G.M. Diagnostics for the developing world: microfluidic paper-based analytical devices. Anal Chem 2010, 82:3-10.
    • (2010) Anal Chem , vol.82 , pp. 3-10
    • Martinez, A.W.1    Phillips, S.T.2    Whitesides, G.M.3
  • 6
    • 56549112867 scopus 로고    scopus 로고
    • Lab on paper
    • Sia S.K., Kricka L.J. Lab on paper. Lab Chip 2008, 8:1988-1991.
    • (2008) Lab Chip , vol.8 , pp. 1988-1991
    • Sia, S.K.1    Kricka, L.J.2
  • 7
    • 78650394401 scopus 로고    scopus 로고
    • What comes next?
    • Whitesides G.M. What comes next?. Lab Chip 2011, 11:191-193.
    • (2011) Lab Chip , vol.11 , pp. 191-193
    • Whitesides, G.M.1
  • 8
    • 56549124749 scopus 로고    scopus 로고
    • Medical diagnostics with paper and camera phones
    • Mukhopadhyay R. Medical diagnostics with paper and camera phones. Anal Chem 2008, 80:3949.
    • (2008) Anal Chem , vol.80 , pp. 3949
    • Mukhopadhyay, R.1
  • 9
    • 78650406348 scopus 로고    scopus 로고
    • Flexographically printed fluidic structures in paper
    • Olkkonen J., Lehtinen K., Erho T. Flexographically printed fluidic structures in paper. Anal Chem 2010, 82:10246-10250.
    • (2010) Anal Chem , vol.82 , pp. 10246-10250
    • Olkkonen, J.1    Lehtinen, K.2    Erho, T.3
  • 10
    • 51949106700 scopus 로고    scopus 로고
    • Inkjet-printed microfluidic multianalyte chemical sensing paper
    • Abe K., Suzuki K., Citterio D. Inkjet-printed microfluidic multianalyte chemical sensing paper. Anal Chem 2008, 80:6928-6934.
    • (2008) Anal Chem , vol.80 , pp. 6928-6934
    • Abe, K.1    Suzuki, K.2    Citterio, D.3
  • 11
    • 79952177518 scopus 로고    scopus 로고
    • Laser-treated hydrophobic paper: an inexpensive microfluidic platform
    • Chitnis G., Ding Z., Chang C.-L., Savran C.A., Ziaie B. Laser-treated hydrophobic paper: an inexpensive microfluidic platform. Lab Chip 2011, 11:1161-1165.
    • (2011) Lab Chip , vol.11 , pp. 1161-1165
    • Chitnis, G.1    Ding, Z.2    Chang, C.-L.3    Savran, C.A.4    Ziaie, B.5
  • 12
    • 42949095976 scopus 로고    scopus 로고
    • Low-cost printing of poly(dimethylsiloxane) barriers to define microchannels in paper
    • Bruzewicz D.A., Reches M., Whitesides G.M. Low-cost printing of poly(dimethylsiloxane) barriers to define microchannels in paper. Anal Chem 2008, 80:3387-3392.
    • (2008) Anal Chem , vol.80 , pp. 3387-3392
    • Bruzewicz, D.A.1    Reches, M.2    Whitesides, G.M.3
  • 14
    • 57449121168 scopus 로고    scopus 로고
    • Paper-based microfluidic devices by plasma treatment
    • Li X., Tian J., Nguyen T., Shen W. Paper-based microfluidic devices by plasma treatment. Anal Chem 2008, 80:9131-9134.
    • (2008) Anal Chem , vol.80 , pp. 9131-9134
    • Li, X.1    Tian, J.2    Nguyen, T.3    Shen, W.4
  • 15
    • 68849085937 scopus 로고    scopus 로고
    • Rapid prototyping of paper-based microfluidics with wax for low-cost, portable bioassay
    • Lu Y., Shi W., Jiang L., Qin J., Lin B. Rapid prototyping of paper-based microfluidics with wax for low-cost, portable bioassay. Electrophoresis 2009, 30:1497-1500.
    • (2009) Electrophoresis , vol.30 , pp. 1497-1500
    • Lu, Y.1    Shi, W.2    Jiang, L.3    Qin, J.4    Lin, B.5
  • 16
    • 68849107869 scopus 로고    scopus 로고
    • Understanding wax printing: a simple micropatterning process for paper-based microfluidics
    • Carrilho E., Martinez A.W., Whitesides G.M. Understanding wax printing: a simple micropatterning process for paper-based microfluidics. Anal Chem 2009, 81:7091-7095.
    • (2009) Anal Chem , vol.81 , pp. 7091-7095
    • Carrilho, E.1    Martinez, A.W.2    Whitesides, G.M.3
  • 17
    • 75749111702 scopus 로고    scopus 로고
    • Fabrication and characterization of paper-based microfluidics prepared in nitrocellulose membrane by wax printing
    • Lu Y., Shi W., Qin J., Lin B. Fabrication and characterization of paper-based microfluidics prepared in nitrocellulose membrane by wax printing. Anal Chem 2009, 82:329-335.
    • (2009) Anal Chem , vol.82 , pp. 329-335
    • Lu, Y.1    Shi, W.2    Qin, J.3    Lin, B.4
  • 18
    • 78649884818 scopus 로고    scopus 로고
    • A low-cost, simple, and rapid fabrication method for paper-based microfluidics using wax screen-printing
    • Dungchai W., Chailapakul O., Henry C.S. A low-cost, simple, and rapid fabrication method for paper-based microfluidics using wax screen-printing. Analyst 2011, 136:77-82.
    • (2011) Analyst , vol.136 , pp. 77-82
    • Dungchai, W.1    Chailapakul, O.2    Henry, C.S.3
  • 19
    • 77956305241 scopus 로고    scopus 로고
    • Visualization and measurement of flow in two-dimensional paper networks
    • Kauffman P., Fu E., Lutz B., Yager P. Visualization and measurement of flow in two-dimensional paper networks. Lab Chip 2010, 10:2614-2617.
    • (2010) Lab Chip , vol.10 , pp. 2614-2617
    • Kauffman, P.1    Fu, E.2    Lutz, B.3    Yager, P.4
  • 20
    • 58149378331 scopus 로고    scopus 로고
    • Three-dimensional microfluidic devices fabricated in layered paper and tape
    • Martinez A.W., Phillips S.T., Whitesides G.M. Three-dimensional microfluidic devices fabricated in layered paper and tape. PNAS 2008, 105:19606-19611.
    • (2008) PNAS , vol.105 , pp. 19606-19611
    • Martinez, A.W.1    Phillips, S.T.2    Whitesides, G.M.3
  • 22
    • 70349335274 scopus 로고    scopus 로고
    • Thin, lightweight, foldable thermochromic displays on paper
    • Siegel A.C., Phillips S.T., Wiley B.J., Whitesides G.M. Thin, lightweight, foldable thermochromic displays on paper. Lab Chip 2009, 9:2775-2781.
    • (2009) Lab Chip , vol.9 , pp. 2775-2781
    • Siegel, A.C.1    Phillips, S.T.2    Wiley, B.J.3    Whitesides, G.M.4
  • 23
    • 84862833163 scopus 로고    scopus 로고
    • Paper on a disc: balancing the capillary-driven flow with a centrifugal force
    • Hwang H., Kim S.-H., Kim T.-H., Park J.-K., Cho Y.-K. Paper on a disc: balancing the capillary-driven flow with a centrifugal force. Lab Chip 2011, 11:3404-4306.
    • (2011) Lab Chip , vol.11 , pp. 3404-4306
    • Hwang, H.1    Kim, S.-H.2    Kim, T.-H.3    Park, J.-K.4    Cho, Y.-K.5
  • 24
    • 77957675473 scopus 로고    scopus 로고
    • Microfluidics without pumps: reinventing the T-sensor and H-filter in paper networks
    • Osborn J.L., Lutz B., Fu E., Kauffman P., Stevens D.Y., Yager P. Microfluidics without pumps: reinventing the T-sensor and H-filter in paper networks. Lab Chip 2010, 10:2659-2665.
    • (2010) Lab Chip , vol.10 , pp. 2659-2665
    • Osborn, J.L.1    Lutz, B.2    Fu, E.3    Kauffman, P.4    Stevens, D.Y.5    Yager, P.6
  • 25
    • 77952537539 scopus 로고    scopus 로고
    • Metering the capillary-driven flow of fluids in paper-based microfluidic devices
    • Noh H., Phillips S.T. Metering the capillary-driven flow of fluids in paper-based microfluidic devices. Anal Chem 2010, 82:4181-4187.
    • (2010) Anal Chem , vol.82 , pp. 4181-4187
    • Noh, H.1    Phillips, S.T.2
  • 28
    • 77957316195 scopus 로고    scopus 로고
    • Fluidic timers for time-dependent, point-of-care assays on paper
    • Noh H., Phillips S.T. Fluidic timers for time-dependent, point-of-care assays on paper. Anal Chem 2010, 82:8071-8078.
    • (2010) Anal Chem , vol.82 , pp. 8071-8078
    • Noh, H.1    Phillips, S.T.2
  • 29
    • 70449922272 scopus 로고    scopus 로고
    • Quantifying colorimetric assays in paper-based microfluidic devices by measuring the transmission of light through paper
    • Ellerbee A.K., Phillips S.T., Siegel A.C., Mirica K.A., Martinez A.W., Striehl P., et al. Quantifying colorimetric assays in paper-based microfluidic devices by measuring the transmission of light through paper. Anal Chem 2009, 81:8447-8452.
    • (2009) Anal Chem , vol.81 , pp. 8447-8452
    • Ellerbee, A.K.1    Phillips, S.T.2    Siegel, A.C.3    Mirica, K.A.4    Martinez, A.W.5    Striehl, P.6
  • 30
    • 67650725811 scopus 로고    scopus 로고
    • Electrochemical detection for paper-based microfluidics
    • Dungchai W., Chailapakul O., Henry C.S. Electrochemical detection for paper-based microfluidics. Anal Chem 2009, 81:5821-5826.
    • (2009) Anal Chem , vol.81 , pp. 5821-5826
    • Dungchai, W.1    Chailapakul, O.2    Henry, C.S.3
  • 31
    • 79951638858 scopus 로고    scopus 로고
    • Electrogenerated chemiluminescence detection in paper-based microfluidic sensors
    • Delaney J.L., Hogan C.F., Tian J., Shen W. Electrogenerated chemiluminescence detection in paper-based microfluidic sensors. Anal Chem 2011, 83:1300-1306.
    • (2011) Anal Chem , vol.83 , pp. 1300-1306
    • Delaney, J.L.1    Hogan, C.F.2    Tian, J.3    Shen, W.4
  • 32
    • 79951724086 scopus 로고    scopus 로고
    • A novel chemiluminescence paper microfluidic biosensor based on enzymatic reaction for uric acid determination
    • Yu J., Wang S., Ge L., Ge S. A novel chemiluminescence paper microfluidic biosensor based on enzymatic reaction for uric acid determination. Biosens Bioelectron 2011, 26:3284-3289.
    • (2011) Biosens Bioelectron , vol.26 , pp. 3284-3289
    • Yu, J.1    Wang, S.2    Ge, L.3    Ge, S.4
  • 34
    • 77749302316 scopus 로고    scopus 로고
    • Lab-on-paper with dual electrochemical/colorimetric detection for simultaneous determination of gold and iron
    • Apilux A., Dungchai W., Siangproh W., Praphairaksit N., Henry C.S., Chailapakul O. Lab-on-paper with dual electrochemical/colorimetric detection for simultaneous determination of gold and iron. Anal Chem 2010, 82:1727-1732.
    • (2010) Anal Chem , vol.82 , pp. 1727-1732
    • Apilux, A.1    Dungchai, W.2    Siangproh, W.3    Praphairaksit, N.4    Henry, C.S.5    Chailapakul, O.6
  • 35
    • 43949138608 scopus 로고    scopus 로고
    • Simple telemedicine for developing regions: camera phones and paper-based microfluidic devices for real-time, off-site diagnosis
    • Martinez A.W., Phillips S.T., Carrilho E., Thomas S.W., Sindi H., Whitesides G.M. Simple telemedicine for developing regions: camera phones and paper-based microfluidic devices for real-time, off-site diagnosis. Anal Chem 2008, 80:3699-3707.
    • (2008) Anal Chem , vol.80 , pp. 3699-3707
    • Martinez, A.W.1    Phillips, S.T.2    Carrilho, E.3    Thomas, S.W.4    Sindi, H.5    Whitesides, G.M.6
  • 37
    • 79952658974 scopus 로고    scopus 로고
    • Microfluidic paper-based chemiluminescence biosensor for simultaneous determination of glucose and uric acid
    • Yu J., Ge L., Huang J., Wang S., Ge S. Microfluidic paper-based chemiluminescence biosensor for simultaneous determination of glucose and uric acid. Lab Chip 2011, 11:1286-1291.
    • (2011) Lab Chip , vol.11 , pp. 1286-1291
    • Yu, J.1    Ge, L.2    Huang, J.3    Wang, S.4    Ge, S.5
  • 38
    • 4344562115 scopus 로고    scopus 로고
    • Electrochemiluminescence (ecl)
    • Richter M.M. Electrochemiluminescence (ecl). Chem Rev 2004, 104:3003-3036.
    • (2004) Chem Rev , vol.104 , pp. 3003-3036
    • Richter, M.M.1
  • 39
    • 78049279337 scopus 로고    scopus 로고
    • Integration of paper-based microfluidic devices with commercial electrochemical readers
    • Nie Z., Deiss F., Liu X., Akbulut O., Whitesides G.M. Integration of paper-based microfluidic devices with commercial electrochemical readers. Lab Chip 2010, 10:3163-3169.
    • (2010) Lab Chip , vol.10 , pp. 3163-3169
    • Nie, Z.1    Deiss, F.2    Liu, X.3    Akbulut, O.4    Whitesides, G.M.5
  • 40
    • 33748762791 scopus 로고    scopus 로고
    • Multiplex measurement of seven tumor markers using an electrochemical protein chip
    • Wilson M.S., Nie W. Multiplex measurement of seven tumor markers using an electrochemical protein chip. Anal Chem 2006, 78:6476-6483.
    • (2006) Anal Chem , vol.78 , pp. 6476-6483
    • Wilson, M.S.1    Nie, W.2
  • 41
    • 33749479326 scopus 로고    scopus 로고
    • Military Medical Science Press, Beijing
    • Li TX Modern clinical immunoassay 2001, Military Medical Science Press, Beijing, pp. 178-209.
    • (2001) Li TX Modern clinical immunoassay , pp. 178-209
  • 44
    • 80051675524 scopus 로고    scopus 로고
    • Streptavidin-functionalized silver-nanoparticle-enriched carbon nanotube tag for ultrasensitive multiplexed detection of tumor markers
    • Lai G., Wu J., Ju H., Yan F. Streptavidin-functionalized silver-nanoparticle-enriched carbon nanotube tag for ultrasensitive multiplexed detection of tumor markers. Adv Funct Mater 2011, 21:2938-2943.
    • (2011) Adv Funct Mater , vol.21 , pp. 2938-2943
    • Lai, G.1    Wu, J.2    Ju, H.3    Yan, F.4
  • 45
    • 0034709433 scopus 로고    scopus 로고
    • Electrogenerated chemiluminescence from derivatives of aluminum quinolate and quinacridones: Cross-reactions with triarylamines lead to singlet emission through triplet-triplet annihilation pathways
    • Gross E.M., Anderson J.D., Slaterbeck A.F., Thayumanavan S., Barlow S., Zhang Y., et al. Electrogenerated chemiluminescence from derivatives of aluminum quinolate and quinacridones: Cross-reactions with triarylamines lead to singlet emission through triplet-triplet annihilation pathways. J Am Chem Soc 2000, 122:4972-4979.
    • (2000) J Am Chem Soc , vol.122 , pp. 4972-4979
    • Gross, E.M.1    Anderson, J.D.2    Slaterbeck, A.F.3    Thayumanavan, S.4    Barlow, S.5    Zhang, Y.6
  • 46
    • 1542404812 scopus 로고    scopus 로고
    • Microfluidic enzyme immunosensors with immobilised protein A and G using chemiluminescence detection
    • Yakovleva J., Davidsson R., Bengtsson M., Laurell T., Emnéus J. Microfluidic enzyme immunosensors with immobilised protein A and G using chemiluminescence detection. Biosens Bioelectron 2003, 19:21-34.
    • (2003) Biosens Bioelectron , vol.19 , pp. 21-34
    • Yakovleva, J.1    Davidsson, R.2    Bengtsson, M.3    Laurell, T.4    Emnéus, J.5
  • 47
    • 0036646094 scopus 로고    scopus 로고
    • Microfluidic enzyme immunoassay using silicon microchip with immobilized antibodies and chemiluminescence detection
    • Yakovleva J., Davidsson R., Lobanova A., Bengtsson M., Eremin S., Laurell T., et al. Microfluidic enzyme immunoassay using silicon microchip with immobilized antibodies and chemiluminescence detection. Anal Chem 2002, 74:2994-3004.
    • (2002) Anal Chem , vol.74 , pp. 2994-3004
    • Yakovleva, J.1    Davidsson, R.2    Lobanova, A.3    Bengtsson, M.4    Eremin, S.5    Laurell, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.