메뉴 건너뛰기




Volumn 24, Issue 1, 2014, Pages 81-97

Surgical navigation in urology: European perspective

Author keywords

3D computed tomography; attitude tracking; electromagnetic tracking; endoscopic tracking; marker based navigation; optical tracking; virtual reality

Indexed keywords

ACCELEROMETER; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED EMISSION TOMOGRAPHY; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; DA VINCI TELEMANIPULATOR; ELECTROMAGNETIC FIELD; ENDOSCOPIC SURGERY; ESOPHAGUS RESECTION; EUROPE; EXTRACORPOREAL LITHOTRIPSY; FEASIBILITY STUDY; FLUOROSCOPY; HUMAN; IN VIVO STUDY; INTRAOPERATIVE PERIOD; KIDNEY BIOPSY; KIDNEY COLLECTING TUBULE; KIDNEY TUMOR; LAPAROSCOPIC RADICAL PROSTATECTOMY; LAPAROSCOPIC SURGERY; MEDICAL SOCIETY; MINIMALLY INVASIVE SURGERY; MULTIDETECTOR COMPUTED TOMOGRAPHY; NONHUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; OPTICAL TRACKING SYSTEM; PARTIAL NEPHRECTOMY; PERCUTANEOUS NEPHROLITHOTOMY; PRIORITY JOURNAL; PROSTATECTOMY; RADIATION EXPOSURE; REVIEW; ROBOTICS; SENSOR; SURGICAL ANATOMY; SURGICAL EQUIPMENT; SURGICAL TECHNOLOGY; TRANSRECTAL ULTRASONOGRAPHY; TREATMENT PLANNING; TROCAR; ULTRASOUND; URETER CATHETER; UROLOGIC SURGERY; UTERINE MANIPULATOR; VIRTUAL REALITY;

EID: 84889883319     PISSN: 09630643     EISSN: 14736586     Source Type: Journal    
DOI: 10.1097/MOU.0000000000000014     Document Type: Review
Times cited : (35)

References (52)
  • 1
    • 42249091045 scopus 로고    scopus 로고
    • Navigation in endoscopic soft tissue surgery - perspectives and limitations
    • Baumhauer M, Feuerstein M, Meinzer HP, Rassweiler J. Navigation in endoscopic soft tissue surgery - perspectives and limitations. J Endourol 2008; 22:751-776.
    • (2008) J Endourol , vol.22 , pp. 751-776
    • Baumhauer, M.1    Feuerstein, M.2    Meinzer, H.P.3    Rassweiler, J.4
  • 3
    • 0020027749 scopus 로고
    • First clinical experience with extracorporeally induced destruction of kidney stones by shock waves
    • Chaussy C, Schmiedt E, Jocham D, et al. First clinical experience with extracorporeally induced destruction of kidney stones by shock waves. J Urol 1982; 127:417-420.
    • (1982) J Urol , vol.127 , pp. 417-420
    • Chaussy, C.1    Schmiedt, E.2    Jocham, D.3
  • 4
    • 0022364290 scopus 로고
    • Extracorporeal shock wave lithotripsy: One-year experience with the Dornier lithotripter
    • Fuchs G, Miller K, Rassweiler J, Eisenberger F. Extracorporeal shock wave lithotripsy: One-year experience with the Dornier lithotripter. Eur Urol 1985; 11:145-149.
    • (1985) Eur Urol , vol.11 , pp. 145-149
    • Fuchs, G.1    Miller, K.2    Rassweiler, J.3    Eisenberger, F.4
  • 8
    • 79953243281 scopus 로고    scopus 로고
    • Shock wave technology and application: An update
    • Rassweiler JJ, Knoll T, Kö hrmann KU, et al. Shock wave technology and application: An update. Eur Urol 2011; 59:784-796.
    • (2011) Eur Urol , Issue.59 , pp. 784-796
    • Rassweiler, J.J.1    Knoll, T.2    Köhrmann, K.U.3
  • 10
    • 0022506859 scopus 로고
    • Multimodal treatment (extracorporeal shock wave lithotripsy and endourology) of complicated renal stone disease
    • Rassweiler J, Gumpinger R, Miller K, et al. Multimodal treatment (extracorporeal shock wave lithotripsy and endourology) of complicated renal stone disease. Eur Urol 1986; 12:294-304.
    • (1986) Eur Urol , vol.12 , pp. 294-304
    • Rassweiler, J.1    Gumpinger, R.2    Miller, K.3
  • 11
    • 70350736702 scopus 로고    scopus 로고
    • Ultrasonography-guided punctures - with and without puncture guide
    • Desai M. Ultrasonography-guided punctures - with and without puncture guide. J Endourol 2009; 23:1641-1643.
    • (2009) J Endourol , vol.23 , pp. 1641-1643
    • Desai, M.1
  • 12
    • 0036393465 scopus 로고    scopus 로고
    • Robotic percutaneous access to the kidney: Comparison with standard manual access
    • Su LM, Stoianovici D, Jarrett TW, et al. Robotic percutaneous access to the kidney: Comparison with standard manual access. J Endourol 2002; 16:471- 475.
    • (2002) J Endourol , vol.16 , pp. 471-475
    • Su, L.M.1    Stoianovici, D.2    Jarrett, T.W.3
  • 13
    • 56349090891 scopus 로고    scopus 로고
    • Electromagnetic field-based navigation for percutaneous procedures on C-arm CT: Experimental evaluation and clinical application
    • Meyer BC, Peter O, Nagel M, et al. Electromagnetic field-based navigation for percutaneous procedures on C-arm CT: Experimental evaluation and clinical application. Eur Radiol 2008; 18:2855-2864.
    • (2008) Eur Radiol , vol.18 , pp. 2855-2864
    • Meyer, B.C.1    Peter, O.2    Nagel, M.3
  • 14
    • 84856386071 scopus 로고    scopus 로고
    • IPAD-assisted percutaneous access to the kidney using marker-based navigation: Initial clinical experience
    • Rassweiler JJ, Müller M, Fangerau M, et al. iPAD-assisted percutaneous access to the kidney using marker-based navigation: Initial clinical experience. Eur Urol 2011; 61:628-631.
    • (2011) Eur Urol , Issue.61 , pp. 628-631
    • Rassweiler, J.J.1    Müller, M.2    Fangerau, M.3
  • 15
    • 84880249524 scopus 로고    scopus 로고
    • Mobile augmented reality for computer-assisted percutaneous nephrolithotomy
    • Müller M, Rassweiler M-C, Klein J, et al. Mobile augmented reality for computer-assisted percutaneous nephrolithotomy. Int J Comput Assist Radiol Surg 2013; 8:663-675.
    • (2013) Int J Comput Assist Radiol Surg , Issue.8 , pp. 663-675
    • Müller, M.1    Rassweiler, M.-C.2    Klein, J.3
  • 16
    • 79954445584 scopus 로고    scopus 로고
    • Navigated renal access using electromagnetic tracking: An initial experience
    • Huber J, Wegner I, Meinzer HP, et al. Navigated renal access using electromagnetic tracking: An initial experience. Surg Endosc 2011; 25:1307-1312.
    • (2011) Surg Endosc , Issue.25 , pp. 1307-1312
    • Huber, J.1    Wegner, I.2    Meinzer, H.P.3
  • 17
    • 84888646369 scopus 로고    scopus 로고
    • Collecting system percutaneous access using real-time tracking sensors: First pig model in vivo experience
    • Rodrigues PL, Vilaça JL, Oliveira C, et al. Collecting system percutaneous access using real-time tracking sensors: First pig model in vivo experience. J Urol 2013; 190:1932-1937.
    • (2013) J Urol , vol.190 , pp. 1932-1937
    • Rodrigues, P.L.1    Vilaça, J.L.2    Oliveira, C.3
  • 18
    • 84884812172 scopus 로고    scopus 로고
    • Laser-guided percutaneous kidney access with the Uro Dyna-CT: First experience of three-dimensional puncture planning with an ex vivo model
    • Ritter M, Rassweiler MC, Häcker A, Michel MS. Laser-guided percutaneous kidney access with the Uro Dyna-CT: First experience of three-dimensional puncture planning with an ex vivo model. World J Urol 2013; 31:1147-1151.
    • (2013) World J Urol , Issue.31 , pp. 1147-1151
    • Ritter, M.1    Rassweiler, M.C.2    Häcker, A.3    Michel, M.S.4
  • 19
    • 84884815420 scopus 로고    scopus 로고
    • Influence of endourological devices on 3D reconstruction image quality using Uro-Dyna-CT
    • Epub ahead of print]
    • Rassweiler MC, Ritter M, Michel MS, Häcker A. Influence of endourological devices on 3D reconstruction image quality using Uro-Dyna-CT. World J Urol 2013; 31:1291-1295. [Epub ahead of print]
    • (2013) World J Urol , Issue.31 , pp. 1291-1295
    • Rassweiler, M.C.1    Ritter, M.2    Michel, M.S.3    Häcker, A.4
  • 20
    • 0024420310 scopus 로고
    • Ultrasound-guided implantation techniques in treatment of prostate cancer
    • Carter SS, Torp-Pedersen ST, Holm HH. Ultrasound-guided implantation techniques in treatment of prostate cancer. Urol Clin North Am 1989; 16:751-762.
    • (1989) Urol Clin North Am , vol.16 , pp. 751-762
    • Carter, S.S.1    Torp-Pedersen, S.T.2    Holm, H.H.3
  • 21
    • 79958297192 scopus 로고    scopus 로고
    • Optimal freeze cycle length for renal cryotherapy
    • Young JL, Khanifar E, Narula N, et al. Optimal freeze cycle length for renal cryotherapy. J Urol 2011; 186:238-288.
    • (2011) J Urol , Issue.186 , pp. 238-288
    • Young, J.L.1    Khanifar, E.2    Narula, N.3
  • 22
    • 0343527969 scopus 로고    scopus 로고
    • High-intensive focused ultrasound in localized prostate cancer
    • Chaussy CG, Thüroff S. High-intensive focused ultrasound in localized prostate cancer. J Endourol 2000; 14:293-299.
    • (2000) J Endourol , vol.14 , pp. 293-299
    • Chaussy, C.G.1    Thüroff, S.2
  • 23
    • 65249148498 scopus 로고    scopus 로고
    • Image-fusion, augmented reality and predictive surgical navigation
    • Ukimura O, Gill IS. Image-fusion, augmented reality and predictive surgical navigation. Urol Clin North Am 2009; 36:115-123.
    • (2009) Urol Clin North Am , vol.36 , pp. 115-123
    • Ukimura, O.1    Gill, I.S.2
  • 25
    • 33745519433 scopus 로고    scopus 로고
    • The MISTELS program to measure technical skill in laparoscopic surgery: Evidence for reliability
    • Vassiliou M, Ghitulescu G, Feldman L. The MISTELS program to measure technical skill in laparoscopic surgery: Evidence for reliability. Surg Endosc 2006; 20:744-777.
    • (2006) Surg Endosc , vol.20 , pp. 744-777
    • Vassiliou, M.1    Ghitulescu, G.2    Feldman, L.3
  • 26
    • 33644587243 scopus 로고    scopus 로고
    • Real-time transrectal ultrasound guidance during nerve-sparing laparoscopic radical prostatectomy impact on surgical margins
    • Ukimura O, Magi-Galluzzi C, Gill IS. Real-time transrectal ultrasound guidance during nerve-sparing laparoscopic radical prostatectomy. Impact on surgical margins. J Urol 2006; 175:1304-1308.
    • (2006) J Urol , vol.175 , pp. 1304-1308
    • Ukimura, O.1    Magi-Galluzzi, C.2    Gill, I.S.3
  • 27
    • 67649882324 scopus 로고    scopus 로고
    • The role of imaging and navigation for natural orifice translumenal endoscopic surgery
    • Rassweiler J, Baumhauer M, Weickert U, et al. The role of imaging and navigation for natural orifice translumenal endoscopic surgery. J Endourol 2009; 23:793-802.
    • (2009) J Endourol , vol.23 , pp. 793-802
    • Rassweiler, J.1    Baumhauer, M.2    Weickert, U.3
  • 28
    • 77956928357 scopus 로고    scopus 로고
    • In-vitro evaluation of a soft tissue navigation system for laparoscopic prostatectomy
    • Teber D, Simpfendö rfer T, Guven S, et al. In-vitro evaluation of a soft tissue navigation system for laparoscopic prostatectomy. J Endourol 2010; 24:1487-1491.
    • (2010) J Endourol , Issue.24 , pp. 1487-1491
    • Teber, D.1    Simpfendörfer, T.2    Guven, S.3
  • 29
    • 65249090265 scopus 로고    scopus 로고
    • Intraoperative tissue characterization and imaging
    • Parekattil S, Yeung LL, Su LM. Intraoperative tissue characterization and imaging. Urol Clin North Am 2009; 36:213-221.
    • (2009) Urol Clin North Am , vol.36 , pp. 213-221
    • Parekattil, S.1    Yeung, L.L.2    Su, L.M.3
  • 30
    • 67649450461 scopus 로고    scopus 로고
    • Augmented reality: A new tool to improve surgical accuracy during laparoscopic partial nephrectomy? Preliminary in vitro and in vivo results
    • Teber D, Guven S, Simpfendö rfer T, et al. Augmented reality: A new tool to improve surgical accuracy during laparoscopic partial nephrectomy? Preliminary in vitro and in vivo results. Eur Urol 2009; 56:332-338.
    • (2009) Eur Urol , vol.56 , pp. 332-338
    • Teber, D.1    Guven, S.2    Simpfendörfer, T.3
  • 31
    • 82455198712 scopus 로고    scopus 로고
    • Augmented reality visualization during laparoscopic radical prostatectomy
    • Simpfendö rfer T, Baumhauer M, Müller M, et al. Augmented reality visualization during laparoscopic radical prostatectomy. J Endourol 2011; 25:1841- 1845.
    • (2011) J Endourol , vol.25 , pp. 1841-1845
    • Simpfendörfer, T.1    Baumhauer, M.2    Müller, M.3
  • 32
    • 84889887814 scopus 로고    scopus 로고
    • Attitude tracking device for improving precision of ultrasound-guided percutaneous procedures
    • SUPPL Abstract no. VP-04-08
    • Petrut B, Hogea M, Schitcu V. Attitude tracking device for improving precision of ultrasound-guided percutaneous procedures. J Endourol) 2012; (Suppl.); Abstract no. VP-04-08.
    • (2012) J Endourol
    • Petrut, B.1    Hogea, M.2    Schitcu, V.3
  • 33
    • 84874197839 scopus 로고    scopus 로고
    • Magnetic tracking in the operating room using the da Vinci telemanipulator is feasible
    • Kenngott HG, Wegner L, Neuhaus J, et al. Magnetic tracking in the operating room using the da Vinci telemanipulator is feasible. J Robot Surg 2013; 7:59- 64.
    • (2013) J Robot Surg , Issue.7 , pp. 59-64
    • Kenngott, H.G.1    Wegner, L.2    Neuhaus, J.3
  • 34
    • 47549114256 scopus 로고    scopus 로고
    • Development of a navigation system for minimally invasive esophagectomy
    • Kenngott HG, Neuhaus J, Müller-Stich BP, et al. Development of a navigation system for minimally invasive esophagectomy. Surg Endosc 2008; 22:1858- 1865.
    • (2008) Surg Endosc , vol.22 , pp. 1858-1865
    • Kenngott, H.G.1    Neuhaus, J.2    Müller-Stich, B.P.3
  • 35
    • 84885187948 scopus 로고    scopus 로고
    • Navigation system for minimally invasive esophagectomy: Experimental study in a porcine model
    • Nickel F, Kenngott H, Neuhaus J, et al. Navigation system for minimally invasive esophagectomy: Experimental study in a porcine model. Surg Endosc 2013; 27:3663-3670.
    • (2013) Surg Endosc , Issue.27 , pp. 3663-3670
    • Nickel, F.1    Kenngott, H.2    Neuhaus, J.3
  • 38
    • 33847769306 scopus 로고    scopus 로고
    • Update: Toward image-guided robotic surgery: Determining the intrinsic accuracy of the daVinci-S robot
    • Kwartowitz DM, Herrell SD, Galloway RL. Update: Toward image-guided robotic surgery: Determining the intrinsic accuracy of the daVinci-S robot. Int J Comput Assist Radiol Surg 2007; 1:301-304.
    • (2007) Int J Comput Assist Radiol Surg , vol.1 , pp. 301-304
    • Kwartowitz, D.M.1    Herrell, S.D.2    Galloway, R.L.3
  • 39
    • 58149185081 scopus 로고    scopus 로고
    • Toward image-guided robotic surgery: System validation
    • discussion 789-790
    • Herrell SD, Kwartowitz DM, Milhoua PM, Galloway RL. Toward image-guided robotic surgery: System validation. J Urol 2009; 181:783-789; discussion 789-790.
    • (2009) J Urol , vol.181 , pp. 783-789
    • Herrell, S.D.1    Kwartowitz, D.M.2    Milhoua, P.M.3    Galloway, R.L.4
  • 41
    • 82255179470 scopus 로고    scopus 로고
    • Three-dimensional reconstruction of renovascular- tumor anatomy to facilitate zero-ischemia partial nephrectomy
    • Ukimura O, Nakamoto M, Gill IS. Three-dimensional reconstruction of renovascular- tumor anatomy to facilitate zero-ischemia partial nephrectomy. Eur Urol 2012; 61:211-217.
    • (2012) Eur Urol , Issue.61 , pp. 211-217
    • Ukimura, O.1    Nakamoto, M.2    Gill, I.S.3
  • 42
    • 27744562508 scopus 로고    scopus 로고
    • Application of soft tissue modelling to image-guided surgery
    • Carter TJ, Sermesant M, Cash DM, et al. Application of soft tissue modelling to image-guided surgery. Med Eng Phys 2005; 27:893-909.
    • (2005) Med Eng Phys , vol.27 , pp. 893-909
    • Carter, T.J.1    Sermesant, M.2    Cash, D.M.3
  • 43
    • 84873110295 scopus 로고    scopus 로고
    • Long-term oncological outcomes after laparoscopic radical prostatectomy
    • Hruza M, Bermejo JL, Flinsbach B, et al. Long-term oncological outcomes after laparoscopic radical prostatectomy. BJU Int 2013; 111:271-280.
    • (2013) BJU Int , Issue.111 , pp. 271-280
    • Hruza, M.1    Bermejo, J.L.2    Flinsbach, B.3
  • 44
    • 84866054912 scopus 로고    scopus 로고
    • Technology advances for prostate biopsy and needle therapies
    • Stoianovici D. Technology advances for prostate biopsy and needle therapies. J Urol 2012; 188:1074-1075.
    • (2012) J Urol , Issue.188 , pp. 1074-1075
    • Stoianovici, D.1
  • 45
    • 84877903485 scopus 로고    scopus 로고
    • Ultrasound probe and needle guide calibration for robotic ultrasound scanning and needle targeting
    • Kim C, Chang D, Petrisor D, et al. Ultrasound probe and needle guide calibration for robotic ultrasound scanning and needle targeting. IEEE Trans Biomed Eng 2013; 60:1728-1734.
    • (2013) IEEE Trans Biomed Eng , Issue.60 , pp. 1728-1734
    • Kim, C.1    Chang, D.2    Petrisor, D.3
  • 46
    • 84872331738 scopus 로고    scopus 로고
    • Bipolar versus multipolar radiofrequency (RF) ablation for the treatment of renal cell carcinoma: Differences in technical and clinical parameters
    • Sommer CM, Lemm G, Hohenstein E, et al. Bipolar versus multipolar radiofrequency (RF) ablation for the treatment of renal cell carcinoma: Differences in technical and clinical parameters. Int J Hyperthermia 2013; 29:21-29.
    • (2013) Int J Hyperthermia , Issue.29 , pp. 21-29
    • Sommer, C.M.1    Lemm, G.2    Hohenstein, E.3
  • 47
    • 84868546092 scopus 로고    scopus 로고
    • Ultrasound elastography as a tool for imaging guidance during prostatectomy: Initial experience
    • Fleming IN, Kut C, Macura K, et al. Ultrasound elastography as a tool for imaging guidance during prostatectomy: Initial experience. Med Sci Monit 2012; 18:CR635-CR642.
    • (2012) Med Sci Monit , vol.18
    • Fleming, I.N.1    Kut, C.2    Macura, K.3
  • 48
    • 70349741099 scopus 로고    scopus 로고
    • Transrectal ultrasound navigation during minilaparotomy retropubic radical prostatectomy: Impact on positive margin rates and prediction of earlier return to continence
    • Okihara K, Kamoi K, Kanazawa M, et al. Transrectal ultrasound navigation during minilaparotomy retropubic radical prostatectomy: Impact on positive margin rates and prediction of earlier return to continence. Int J Urol 2009; 16:820-825.
    • (2009) Int J Urol , vol.16 , pp. 820-825
    • Okihara, K.1    Kamoi, K.2    Kanazawa, M.3
  • 49
    • 84878820566 scopus 로고    scopus 로고
    • Efficacy of DynaCT for surgical navigation during complex laparoscopic surgery: An initial experience
    • Nozaki T, Fujiuchi Y, Komiya A, Fuse H. Efficacy of DynaCT for surgical navigation during complex laparoscopic surgery: An initial experience. Surg Endosc 2013; 27:903-909.
    • (2013) Surg Endosc , Issue.27 , pp. 903-909
    • Nozaki, T.1    Fujiuchi, Y.2    Komiya, A.3    Fuse, H.4
  • 50
    • 77957556483 scopus 로고    scopus 로고
    • Complications in 2200 consecutive laparoscopic radical prostatectomies: Standardised evaluation and analysis of learning curves
    • Hruza M, Weiss HO, Pini G, et al. Complications in 2200 consecutive laparoscopic radical prostatectomies: Standardised evaluation and analysis of learning curves. Eur Urol 2010; 58:733-741.
    • (2010) Eur Urol , Issue.58 , pp. 733-741
    • Hruza, M.1    Weiss, H.O.2    Pini, G.3
  • 51
    • 70349487695 scopus 로고    scopus 로고
    • Prevention and management of ureteral injuiries during laparoscopic radical prostatectomy: The Heilbronn experience and a review of the literature
    • Teber D, Gö zen AS, Cresswell J, et al. Prevention and management of ureteral injuiries during laparoscopic radical prostatectomy: The Heilbronn experience and a review of the literature. World J Urol 2009; 27:613-618.
    • (2009) World J Urol , vol.27 , pp. 613-618
    • Teber, D.1    Gözen, A.S.2    Cresswell, J.3
  • 52
    • 34247246320 scopus 로고    scopus 로고
    • Mechanical simulators for training for laparoscopic surgery in urology
    • Rassweiler J, Klein J, Teber D, et al. Mechanical simulators for training for laparoscopic surgery in urology. J Endourol 2007; 21:252-262.
    • (2007) J Endourol , vol.21 , pp. 252-262
    • Rassweiler, J.1    Klein, J.2    Teber, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.