메뉴 건너뛰기




Volumn 4, Issue 3, 2009, Pages 281-286

Towards image guided robotic surgery: Multi-arm tracking through hybrid localization

Author keywords

Image guided surgery; Physical space localization; Robotic assisted surgery; Tracking

Indexed keywords

ACCURACY; ANALYTICAL ERROR; ARTICLE; CALIBRATION; COMPUTER ASSISTED SURGERY; ENDOSCOPY; IMAGE PROCESSING; MEDICAL INFORMATION; PRIORITY JOURNAL; ROBOTICS;

EID: 70349747046     PISSN: 18616410     EISSN: 18616429     Source Type: Journal    
DOI: 10.1007/s11548-009-0294-1     Document Type: Article
Times cited : (31)

References (16)
  • 2
    • 85103590248 scopus 로고
    • A kinematic notation for lower-pair mechanisms based on matrices
    • Denavit J, Hartenberg R (1955) A kinematic notation for lower-pair mechanisms based on matrices. Trans ASME J Appl Mech 23:215-221
    • (1955) Trans ASME J Appl Mech , vol.23 , pp. 215-221
    • Denavit, J.1    Hartenberg, R.2
  • 4
    • 0035437717 scopus 로고    scopus 로고
    • The distribution of target registration error in rigid-body point-based registration
    • Fitzpatrick JM, West JB (2001) The distribution of target registration error in rigid-body point-based registration. IEEE Trans Med Imaging 20(9): 917-927
    • (2001) IEEE Trans Med Imaging , vol.20 , Issue.9 , pp. 917-927
    • Fitzpatrick, J.M.1    West, J.B.2
  • 6
    • 0043175141 scopus 로고    scopus 로고
    • Accuracy assessment protocols for electromagnetic tracking systems
    • Frantz DD, Wiles AD, Leis SE, Kirsch SR (2003) Accuracy assessment protocols for electromagnetic tracking systems. Phys Med Biol 48(14):2241-2251
    • (2003) Phys Med Biol , vol.48 , Issue.14 , pp. 2241-2251
    • Frantz, D.D.1    Wiles, A.D.2    Leis, S.E.3    Kirsch, S.R.4
  • 7
    • 51649120145 scopus 로고    scopus 로고
    • A constrained optimization approach to virtual fixtures for multi-handed tasks
    • In: ICRA 2008 doi: 10.1109/ROBOT.2008.4543730
    • Kapoor A, Taylor R (2008) A constrained optimization approach to virtual fixtures for multi-handed tasks. In: IEEE international conference on robotics and automation. ICRA 2008, pp 3401-3406. doi: 10.1109/ ROBOT.2008.4543730
    • (2008) IEEE International Conference on Robotics and Automation , pp. 3401-3406
    • Kapoor, A.1    Taylor, R.2
  • 8
    • 4944224825 scopus 로고    scopus 로고
    • The paky, hermes, aesop, zeus, and da vinci robotic systems
    • Kim HL, Schulam P (2004) The paky, hermes, aesop, zeus, and da vinci robotic systems. Urol Clin North Am 31(4):659-669
    • (2004) Urol Clin North Am , vol.31 , Issue.4 , pp. 659-669
    • Kim, H.L.1    Schulam, P.2
  • 9
    • 63449118082 scopus 로고    scopus 로고
    • Determining the presence of bias error using statistical methods
    • Kwartowitz D, Galloway R, Shiavi R (2009) Determining the presence of bias error using statistical methods. IEEE Trans Inf Technol Biomed 13(1):1-4
    • (2009) IEEE Trans Inf Technol Biomed , vol.13 , Issue.1 , pp. 1-4
    • Kwartowitz, D.1    Galloway, R.2    Shiavi, R.3
  • 10
    • 33847769306 scopus 로고    scopus 로고
    • Update: Toward image-guided robotic surgery: Determining the intrinsic accuracy of the davinci-s robot
    • Kwartowitz D, Herrell S, Galloway R (2007) Update: Toward image-guided robotic surgery: Determining the intrinsic accuracy of the davinci-s robot. Int J Comput Assist Radiol Surg 1(5):301-304
    • (2007) Int J Comput Assist Radiol Surg , vol.1 , Issue.5 , pp. 301-304
    • Kwartowitz, D.1    Herrell, S.2    Galloway, R.3
  • 11
    • 33751416148 scopus 로고    scopus 로고
    • Toward image-guided robotic surgery: Determining intrinsic accuracy of the da vinci robot
    • Kwartowitz DM, Herrell SD, Galloway RL (2006) Toward image-guided robotic surgery: Determining intrinsic accuracy of the da vinci robot. Int J Comput Assist Radiol Surg 1(3):157-165
    • (2006) Int J Comput Assist Radiol Surg , vol.1 , Issue.3 , pp. 157-165
    • Kwartowitz, D.M.1    Herrell, S.D.2    Galloway, R.L.3
  • 12
    • 44949229333 scopus 로고    scopus 로고
    • Importance of surgical margins in the management of renal cell carcinoma
    • 308-317 doi: 10.1038/ncpuro1121
    • Lam JS, Bergman J, Breda A, Schulam PG (2008) Importance of surgical margins in the management of renal cell carcinoma. Nat Clin Pract Urol 5(6):308-317, 1743-4270. doi: 10.1038/ncpuro1121
    • (2008) Nat Clin Pract Urol , vol.5 , Issue.6 , pp. 1743-4270
    • Lam, J.S.1    Bergman, J.2    Breda, A.3    Schulam, P.G.4
  • 13
    • 0018535593 scopus 로고
    • Accuracy of a two-sensor sonic digitizer
    • doi: 10.1118/1.594618. URL
    • Rosen II, Lane RG, Kelsey CA (1979) Accuracy of a two-sensor sonic digitizer. Med PhHs 6(6):536-538. doi: 10.1118/1.594618. URL: http://link.aip.org/link/?MPH/6/536/1
    • (1979) Med Phys , vol.6 , Issue.6 , pp. 536-538
    • Rosen, I.I.1    Lane, R.G.2    Kelsey, C.A.3
  • 15
    • 0035999421 scopus 로고    scopus 로고
    • Quantitative analysis of factors affecting intraoperative precision and stability of optoelectronic and electromagnetic tracking systems
    • Wagner A, Schicho K, Birkfellner W, Figl M, Seemann R, Konig F, Kainberger F, Ewers R (2002) Quantitative analysis of factors affecting intraoperative precision and stability of optoelectronic and electromagnetic tracking systems. Med Phys 29(5):905-912
    • (2002) Med Phys , vol.29 , Issue.5 , pp. 905-912
    • Wagner, A.1    Schicho, K.2    Birkfellner, W.3    Figl, M.4    Seemann, R.5    Konig, F.6    Kainberger, F.7    Ewers, R.8
  • 16
    • 5644267915 scopus 로고    scopus 로고
    • Accuracy assessment and interpretation for optical tracking systems
    • In: SPIE, San Diego
    • Wiles A, Thompson D, Frantz D (2004) Accuracy assessment and interpretation for optical tracking systems. In: SPIE: Medical Imaging. SPIE, San Diego
    • (2004) SPIE: Medical Imaging
    • Wiles, A.1    Thompson, D.2    Frantz, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.