-
1
-
-
23644441508
-
Three-dimensional growth of differentiating MC3T3-E1 preosteoblasts on porous titanium scaffolds
-
St-Pierre, J.P., Gauthier, M., Lefebvre, L.P., and Tabrizian, M. Three-dimensional growth of differentiating MC3T3-E1 preosteoblasts on porous titanium scaffolds. Biomaterials 26, 7319, 2005.
-
(2005)
Biomaterials
, vol.26
, pp. 7319
-
-
St-Pierre, J.P.1
Gauthier, M.2
Lefebvre, L.P.3
Tabrizian, M.4
-
2
-
-
34249691898
-
Mechanical properties of open-pore titanium foam
-
Imwinkelried, T. Mechanical properties of open-pore titanium foam. J Biomed Mater Res A 81, 964, 2007.
-
(2007)
J Biomed Mater Res A
, vol.81
, pp. 964
-
-
Imwinkelried, T.1
-
3
-
-
33744947282
-
Experimental and clinical performance of porous tantalum in orthopedic surgery
-
Levine, B.R., Sporer, S., Poggie, R.A., Della Valle, C.J., and Jacobs, J.J. Experimental and clinical performance of porous tantalum in orthopedic surgery. Biomaterials 27, 4671, 2006.
-
(2006)
Biomaterials
, vol.27
, pp. 4671
-
-
Levine, B.R.1
Sporer, S.2
Poggie, R.A.3
Della Valle, C.J.4
Jacobs, J.J.5
-
4
-
-
77955933775
-
Characterization of the deformation behavior of intermediate porosity interconnected Ti foams using micro-computed tomography and direct finite element modeling
-
Singh, R., Lee, P.D., Lindley, T.C., Kohlhauser, C., Hellmich, C., Bram, M., et al. Characterization of the deformation behavior of intermediate porosity interconnected Ti foams using micro-computed tomography and direct finite element modeling. Acta Biomater 6, 2342, 2010.
-
(2010)
Acta Biomater
, vol.6
, pp. 2342
-
-
Singh, R.1
Lee, P.D.2
Lindley, T.C.3
Kohlhauser, C.4
Hellmich, C.5
Bram, M.6
-
5
-
-
44549083121
-
Porous NiTi for bone implants: A review
-
Bansiddhi, A., Sargeant, T.D., Stupp, S.I., and Dunand, D.C. Porous NiTi for bone implants: a review. Acta Biomater 4, 773, 2008.
-
(2008)
Acta Biomater
, vol.4
, pp. 773
-
-
Bansiddhi, A.1
Sargeant, T.D.2
Stupp, S.I.3
Dunand, D.C.4
-
6
-
-
0034347635
-
Processing of metal foams-challenges and opportunities
-
Kö rner, C., and Singer, R.F. Processing of metal foams-challenges and opportunities. Adv Eng Mater 2, 159, 2000.
-
(2000)
Adv Eng Mater
, vol.2
, pp. 159
-
-
Körner, C.1
Singer, R.F.2
-
7
-
-
79953841925
-
Osteoinduction of porous Ti implants with a channel structure fabricated by selective laser melting
-
Fukuda, A., Takemoto, M., Saito, T., Fujibayashi, S., Neo, M., Pattanayak, D.K., et al. Osteoinduction of porous Ti implants with a channel structure fabricated by selective laser melting. Acta Biomater 7, 2327, 2011.
-
(2011)
Acta Biomater
, vol.7
, pp. 2327
-
-
Fukuda, A.1
Takemoto, M.2
Saito, T.3
Fujibayashi, S.4
Neo, M.5
Pattanayak, D.K.6
-
8
-
-
74749105352
-
Selective laser melting: A unit cell approach for the manufacture of porous, titanium, bone in-growth constructs, suitable for orthopedic applications. II. Randomized structures
-
Mullen, L., Stamp, R.C., Fox, P., Jones, E., Ngo, C., and Sutcliffe, C.J. Selective laser melting: a unit cell approach for the manufacture of porous, titanium, bone in-growth constructs, suitable for orthopedic applications. II. Randomized structures. J Biomed Mater Res B Appl Biomater 92, 178, 2010.
-
(2010)
J Biomed Mater Res B Appl Biomater
, vol.92
, pp. 178
-
-
Mullen, L.1
Stamp, R.C.2
Fox, P.3
Jones, E.4
Ngo, C.5
Sutcliffe, C.J.6
-
9
-
-
55249116312
-
Microstructure and mechanical behavior of Ti-6Al-4V produced by rapid-layer manufacturing, for biomedical applications
-
Murr, L.E., Quinones, S.A., Gaytan, S.M., Lopez, M.I., Rodela, A., Martinez, E.Y., et al. Microstructure and mechanical behavior of Ti-6Al-4V produced by rapid-layer manufacturing, for biomedical applications. J Mech Behav Biomed Mater 2, 20, 2009.
-
(2009)
J Mech Behav Biomed Mater
, vol.2
, pp. 20
-
-
Murr, L.E.1
Quinones, S.A.2
Gaytan, S.M.3
Lopez, M.I.4
Rodela, A.5
Martinez, E.Y.6
-
10
-
-
67649841597
-
Rapid prototyping: Porous titanium alloy scaffolds produced by selective laser melting for bone tissue engineering
-
Warnke, P.H., Douglas, T., Wollny, P., Sherry, E., Steiner, M., Galonska, S., et al. Rapid prototyping: porous titanium alloy scaffolds produced by selective laser melting for bone tissue engineering. Tissue Eng Part C Methods 15, 115, 2009.
-
(2009)
Tissue Eng Part C Methods
, vol.15
, pp. 115
-
-
Warnke, P.H.1
Douglas, T.2
Wollny, P.3
Sherry, E.4
Steiner, M.5
Galonska, S.6
-
11
-
-
84889792897
-
Fundamental studies on the influence of process parameters on the properties of SLM parts
-
Meier, H., and Haberland, C. Fundamental studies on the influence of process parameters on the properties of SLM parts. Materialwissenschaft und Werkstofftechnik 93, 665, 2008.
-
(2008)
Materialwissenschaft und Werkstofftechnik
, vol.93
, pp. 665
-
-
Meier, H.1
Haberland, C.2
-
12
-
-
0036005924
-
Slow and continuous application of human recombinant bone morphogenetic protein via biodegradable poly (lactide-co-glycolide) foamspheres
-
Weber, F.E., Eyrich, G., Gratz, K.W., Maly, F.E., and Sailer, H.F. Slow and continuous application of human recombinant bone morphogenetic protein via biodegradable poly (lactide-co-glycolide) foamspheres. Int J Oral Maxillofac Surg 31, 60, 2002.
-
(2002)
Int J Oral Maxillofac Surg
, vol.31
, pp. 60
-
-
Weber, F.E.1
Eyrich, G.2
Gratz, K.W.3
Maly, F.E.4
Sailer, H.F.5
-
13
-
-
29144454890
-
Porous Ti6Al4V scaffolds directly fabricated by 3D fibre deposition technique: Effect of nozzle diameter
-
Li, J.P., de Wijn, J.R., van Blitterswijk, C.A., and de Groot, K. Porous Ti6Al4V scaffolds directly fabricated by 3D fibre deposition technique: effect of nozzle diameter. J Mater Sci Mater Med 16, 1159, 2005.
-
(2005)
J Mater Sci Mater Med
, vol.16
, pp. 1159
-
-
Li, J.P.1
De Wijn, J.R.2
Van Blitterswijk, C.A.3
De Groot, K.4
-
14
-
-
33646527333
-
Osteoblast-like cells are sensitive to submicron-scale surface structure
-
Zhao, G., Zinger, O., Schwartz, Z., Wieland, M., Landolt, D., and Boyan, B.D. Osteoblast-like cells are sensitive to submicron-scale surface structure. Clin Oral Implants Res 17, 258, 2006.
-
(2006)
Clin Oral Implants Res
, vol.17
, pp. 258
-
-
Zhao, G.1
Zinger, O.2
Schwartz, Z.3
Wieland, M.4
Landolt, D.5
Boyan, B.D.6
-
15
-
-
33947591669
-
Requirement for both micron-and submicron scale structure for synergistic responses of osteoblasts to substrate surface energy and topography
-
Zhao, G., Raines, A.L., Wieland, M., Schwartz, Z., and Boyan, B.D. Requirement for both micron-and submicron scale structure for synergistic responses of osteoblasts to substrate surface energy and topography. Biomaterials 28, 2821, 2007.
-
(2007)
Biomaterials
, vol.28
, pp. 2821
-
-
Zhao, G.1
Raines, A.L.2
Wieland, M.3
Schwartz, Z.4
Boyan, B.D.5
-
16
-
-
84860443214
-
Rapid manufacturing of individual Ti-6AI-4V bone implants
-
Schumacher, R., de Wild, M., Fabbri, S., Yildiz, A., and Schkommodau, E. Rapid manufacturing of individual Ti-6AI-4V bone implants. Eur Cell Mater 17, 22, 2009.
-
(2009)
Eur Cell Mater
, vol.17
, pp. 22
-
-
Schumacher, R.1
De Wild, M.2
Fabbri, S.3
Yildiz, A.4
Schkommodau, E.5
-
18
-
-
0345722833
-
-
Berlin: Springer
-
Brunette, D.M., Tengvall, P., and Textor, M. Titanium in Medicine: Material Science, Surface Science, Engineering, Biological Response and Medical Applications. Berlin: Springer, 2001.
-
(2001)
Titanium in Medicine: Material Science, Surface Science, Engineering, Biological Response and Medical Applications
-
-
Brunette, D.M.1
Tengvall, P.2
Textor, M.3
-
19
-
-
33745934441
-
Biomechanical evaluation of the interfacial strength of a chemically modified sandblasted and acidetched titanium surface
-
Ferguson, S.J., Broggini,N.,Wieland, M., deWild, M.,Rupp, F., Geis-Gerstorfer, J., et al. Biomechanical evaluation of the interfacial strength of a chemically modified sandblasted and acidetched titanium surface. J Biomed Mater Res A 78, 291, 2006.
-
(2006)
J Biomed Mater Res A
, vol.78
, pp. 291
-
-
Ferguson, S.J.1
Broggini, N.2
Wieland, M.3
Dewild, M.4
Rupp, F.5
Geis-Gerstorfer, J.6
-
20
-
-
0033140230
-
Implant surfaces and interface processes
-
Kasemo, B., and Gold, J. Implant surfaces and interface processes. Adv Dent Res 13, 8, 1999.
-
(1999)
Adv Dent Res
, vol.13
, pp. 8
-
-
Kasemo, B.1
Gold, J.2
-
21
-
-
33645096659
-
Enhancing surface free energy and hydrophilicity through chemical modification of microstructured titanium implant surfaces
-
Rupp, F., Scheideler, L., Olshanska, N., de Wild, M., Wieland, M., and Geis-Gerstorfer, J. Enhancing surface free energy and hydrophilicity through chemical modification of microstructured titanium implant surfaces. J Biomed Mater Res A 76, 323, 2006.
-
(2006)
J Biomed Mater Res A
, vol.76
, pp. 323
-
-
Rupp, F.1
Scheideler, L.2
Olshanska, N.3
De Wild, M.4
Wieland, M.5
Geis-Gerstorfer, J.6
-
22
-
-
57449114754
-
Fabrication of TiO2-coated epoxy replicas with identical dual-type surface topographies used in cell culture assays
-
Schuler, M., Kunzler, T.P., de Wild, M., Sprecher, C.M., Trentin, D., Brunette, D.M., et al. Fabrication of TiO2-coated epoxy replicas with identical dual-type surface topographies used in cell culture assays. J Biomed Mater Res A 88, 12, 2009.
-
(2009)
J Biomed Mater Res A
, vol.88
, pp. 12
-
-
Schuler, M.1
Kunzler, T.P.2
De Wild, M.3
Sprecher, C.M.4
Trentin, D.5
Brunette, D.M.6
-
23
-
-
0030246956
-
Surface roughness modulates the local production of growth factors and cytokines by osteoblast-like MG-63 cells
-
Kieswetter, K., Schwartz, Z., Hummert, T.W., Cochran, D.L., Simpson, J., Dean, D.D., et al. Surface roughness modulates the local production of growth factors and cytokines by osteoblast-like MG-63 cells. J Biomed Mater Res 32, 55, 1996.
-
(1996)
J Biomed Mater Res
, vol.32
, pp. 55
-
-
Kieswetter, K.1
Schwartz, Z.2
Hummert, T.W.3
Cochran, D.L.4
Simpson, J.5
Dean, D.D.6
-
24
-
-
0142088695
-
Early loading of nonsubmerged titanium implants with a sandblasted and acid-etched (SLA) surface: 3-year results of a prospective study in partially edentulous patients
-
Bornstein, M.M., Lussi, A., Schmid, B., Belser, U.C., and Buser, D. Early loading of nonsubmerged titanium implants with a sandblasted and acid-etched (SLA) surface: 3-year results of a prospective study in partially edentulous patients. Int J Oral Maxillofac Implants 18, 659, 2003.
-
(2003)
Int J Oral Maxillofac Implants
, vol.18
, pp. 659
-
-
Bornstein, M.M.1
Lussi, A.2
Schmid, B.3
Belser, U.C.4
Buser, D.5
-
25
-
-
4143063995
-
Enhanced bone apposition to a chemically modified SLA titanium surface
-
Buser, D., Broggini, N., Wieland, M., Schenk, R.K., Denzer, A.J., Cochran, D.L., et al. Enhanced bone apposition to a chemically modified SLA titanium surface. J Dent Res 83, 529, 2004.
-
(2004)
J Dent Res
, vol.83
, pp. 529
-
-
Buser, D.1
Broggini, N.2
Wieland, M.3
Schenk, R.K.4
Denzer, A.J.5
Cochran, D.L.6
-
26
-
-
84856713436
-
Surface modification and invitro investigation of generatively produced implants
-
de Wild, M., Maier, K., Schneider, M., Tschumi, S., and Schumacher, R., Albrecht, H. Surface modification and invitro investigation of generatively produced implants. BIOmaterialien 11, 157, 2010.
-
(2010)
BIOmaterialien
, vol.11
, pp. 157
-
-
De Wild, M.1
Maier, K.2
Schneider, M.3
Tschumi, S.4
Schumacher, R.5
Albrecht, H.6
-
27
-
-
79953711414
-
Bone regeneration in the presence of a synthetic hydroxyapatite/silica oxide-based and a xenogenic hydroxyapatite-based bone substitute material
-
Kruse, A., Jung, R.E., Nicholls, F., Zwahlen, R.A., Hammerle, C.H., and Weber, F.E. Bone regeneration in the presence of a synthetic hydroxyapatite/silica oxide-based and a xenogenic hydroxyapatite-based bone substitute material. Clin Oral Implants Res 22, 506, 2011.
-
(2011)
Clin Oral Implants Res
, vol.22
, pp. 506
-
-
Kruse, A.1
Jung, R.E.2
Nicholls, F.3
Zwahlen, R.A.4
Hammerle, C.H.5
Weber, F.E.6
-
28
-
-
84862844579
-
Effect of cerium chloride application on fibroblast and osteoblast proliferation and differentiation
-
Schmidlin, P.R., Tchouboukov, A., Wegehaupt, F.J., and Weber, F.E. Effect of cerium chloride application on fibroblast and osteoblast proliferation and differentiation. Arch Oral Biol 57, 892, 2012.
-
(2012)
Arch Oral Biol
, vol.57
, pp. 892
-
-
Schmidlin, P.R.1
Tchouboukov, A.2
Wegehaupt, F.J.3
Weber, F.E.4
-
29
-
-
0032886563
-
Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial
-
Bobyn, J.D., Stackpool, G.J., Hacking, S.A., Tanzer, M., and Krygier, J.J. Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial. J Bone Joint Surg Br 81B, 907, 1999.
-
(1999)
J Bone Joint Surg Br
, vol.81 B
, pp. 907
-
-
Bobyn, J.D.1
Stackpool, G.J.2
Hacking, S.A.3
Tanzer, M.4
Krygier, J.J.5
-
30
-
-
35948993000
-
Evaluation of a novel biphasic calcium phosphate in standardized bone defects: A histologic and histomorphometric study in the mandibles of minipigs
-
Jensen, S.S., Yeo, A., Dard, M., Hunziker, E., Schenk, R., and Buser, D. Evaluation of a novel biphasic calcium phosphate in standardized bone defects: a histologic and histomorphometric study in the mandibles of minipigs. Clin Oral Implants Res 18, 752, 2007.
-
(2007)
Clin Oral Implants Res
, vol.18
, pp. 752
-
-
Jensen, S.S.1
Yeo, A.2
Dard, M.3
Hunziker, E.4
Schenk, R.5
Buser, D.6
-
31
-
-
34547348159
-
Bone response inside free-form fabricated macroporous hydroxyapatite scaffolds with and without an open microporosity
-
Malmstrom, J., Adolfsson, E., Arvidsson, A., and Thomsen, P. Bone response inside free-form fabricated macroporous hydroxyapatite scaffolds with and without an open microporosity. Clin Implant Dent Relat Res 9, 79, 2007.
-
(2007)
Clin Implant Dent Relat Res
, vol.9
, pp. 79
-
-
Malmstrom, J.1
Adolfsson, E.2
Arvidsson, A.3
Thomsen, P.4
-
33
-
-
67349188044
-
In vivo and in vitro evaluation of flexible, cottonwool-like nanocomposites as bone substitute material for complex defects
-
Schneider, O.D., Weber, F., Brunner, T.J., Loher, S., Ehrbar, M., Schmidlin, P.R., et al. In vivo and in vitro evaluation of flexible, cottonwool-like nanocomposites as bone substitute material for complex defects. Acta Biomater 5, 1775, 2009.
-
(2009)
Acta Biomater
, vol.5
, pp. 1775
-
-
Schneider, O.D.1
Weber, F.2
Brunner, T.J.3
Loher, S.4
Ehrbar, M.5
Schmidlin, P.R.6
-
34
-
-
84872665177
-
Evaluation of moldable, in situ hardening calcium phosphate bone graft substitutes
-
Schmidlin, P.R., Nicholls, F., Kruse, A., Zwahlen, R.A., and Weber, F.E. Evaluation of moldable, in situ hardening calcium phosphate bone graft substitutes. Clin Oral Implants Res 24, 149, 2013.
-
(2013)
Clin Oral Implants Res
, vol.24
, pp. 149
-
-
Schmidlin, P.R.1
Nicholls, F.2
Kruse, A.3
Zwahlen, R.A.4
Weber, F.E.5
-
35
-
-
68549092607
-
Effects of titanium surface topography on bone integration: A systematic review
-
Wennerberg, A., and Albrektsson, T. Effects of titanium surface topography on bone integration: a systematic review. Clin Oral Implants Res 20 Suppl 4, 172, 2009.
-
(2009)
Clin Oral Implants Res
, vol.20
, Issue.SUPPL.. 4
, pp. 172
-
-
Wennerberg, A.1
Albrektsson, T.2
-
36
-
-
77950688690
-
On implant surfaces: A review of current knowledge and opinions
-
Wennerberg, A., and Albrektsson, T. On implant surfaces: a review of current knowledge and opinions. Int J Oral Maxillofac Implants 25, 63, 2010.
-
(2010)
Int J Oral Maxillofac Implants
, vol.25
, pp. 63
-
-
Wennerberg, A.1
Albrektsson, T.2
-
37
-
-
67650786995
-
Electron beam-melted, free-form-fabricated titanium alloy implants: Material surface characterization and early bone response in rabbits
-
Thomsen, P., Malmstrom, J., Emanuelsson, L., Rene, M., and Snis, A. Electron beam-melted, free-form-fabricated titanium alloy implants: Material surface characterization and early bone response in rabbits. J Biomed Mater Res B Appl Biomater 90, 35, 2009.
-
(2009)
J Biomed Mater Res B Appl Biomater
, vol.90
, pp. 35
-
-
Thomsen, P.1
Malmstrom, J.2
Emanuelsson, L.3
Rene, M.4
Snis, A.5
-
38
-
-
79251639042
-
Bioactive Ti metal analogous to human cancellous bone: Fabrication by selective laser melting and chemical treatments
-
Pattanayak, D.K., Fukuda, A., Matsushita, T., Takemoto, M., Fujibayashi, S., Sasaki, K., et al. Bioactive Ti metal analogous to human cancellous bone: Fabrication by selective laser melting and chemical treatments. Acta Biomater 7, 1398, 2011.
-
(2011)
Acta Biomater
, vol.7
, pp. 1398
-
-
Pattanayak, D.K.1
Fukuda, A.2
Matsushita, T.3
Takemoto, M.4
Fujibayashi, S.5
Sasaki, K.6
|