메뉴 건너뛰기




Volumn 10, Issue 6, 2013, Pages

Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates

Author keywords

[No Author keywords available]

Indexed keywords

BRAIN COMPUTER INTERFACES (BCIS); CLASSIFICATION SYSTEM; FAILURE MODE ANALYSIS; IMPEDANCE MEASUREMENT; MEAN TIME TO FAILURE; MICROELECTRODE ARRAY; PEOPLE WITH DISABILITIES; RETROSPECTIVE ANALYSIS;

EID: 84889010832     PISSN: 17412560     EISSN: 17412552     Source Type: Journal    
DOI: 10.1088/1741-2560/10/6/066014     Document Type: Article
Times cited : (447)

References (40)
  • 1
    • 84857290728 scopus 로고    scopus 로고
    • Decoding 3D reach and grasp from hybrid signals in motor and premotor cortices: Spikes, multiunit activity, and local field potentials
    • 10.1152/jn.00781.2011
    • Bansal A K, Truccolo W, Vargas-Irwin C E and Donoghue J P 2012 Decoding 3D reach and grasp from hybrid signals in motor and premotor cortices: spikes, multiunit activity, and local field potentials J. Neurophysiol. 107 1337-55
    • (2012) J. Neurophysiol. , vol.107 , pp. 1337-1355
    • Bansal, A.K.1    Truccolo, W.2    Vargas-Irwin, C.E.3    Donoghue, J.P.4
  • 2
    • 23644450358 scopus 로고    scopus 로고
    • Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays
    • DOI 10.1016/j.expneurol.2005.04.020, PII S0014488605001457
    • Biran R, Martin D C and Tresco P A 2005 Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays Exp. Neurol. 195 115-26 (Pubitemid 41116819)
    • (2005) Experimental Neurology , vol.195 , Issue.1 , pp. 115-126
    • Biran, R.1    Martin, D.C.2    Tresco, P.A.3
  • 4
    • 84875823286 scopus 로고    scopus 로고
    • An implantable wireless neural interface for recording cortical circuit dynamics in moving primates
    • 10.1088/1741-2560/10/2/026010 1741-2552 026010
    • Borton D A, Yin M, Aceros J and Nurmikko A 2013 An implantable wireless neural interface for recording cortical circuit dynamics in moving primates J. Neural Eng. 10 026010
    • (2013) J. Neural Eng. , vol.10 , Issue.2
    • Borton, D.A.1    Yin, M.2    Aceros, J.3    Nurmikko, A.4
  • 5
    • 79959536375 scopus 로고    scopus 로고
    • Long-term stability of neural prosthetic control signals from silicon cortical arrays in rhesus macaque motor cortex
    • 10.1088/1741-2560/8/4/045005 1741-2552 045005
    • Chestek C A et al 2011 Long-term stability of neural prosthetic control signals from silicon cortical arrays in rhesus macaque motor cortex J. Neural Eng. 8 045005
    • (2011) J. Neural Eng. , vol.8 , Issue.4
    • Chestek, C.A.1
  • 6
    • 0000688812 scopus 로고
    • Histopathological changes produced by implanted electrodes in cat brains; Comparison with histopathological changes in human and experimental puncture wounds
    • 10.3171/jns.1957.14.3.0302 0022-3085
    • Collias J C and Manuelidis E E 1957 Histopathological changes produced by implanted electrodes in cat brains; comparison with histopathological changes in human and experimental puncture wounds J. Neurosurg. 14 302-28
    • (1957) J. Neurosurg. , vol.14 , pp. 302-328
    • Collias, J.C.1    Manuelidis, E.E.2
  • 7
    • 0026008251 scopus 로고
    • Aspects of silicone rubber as an encapsulant for neurological prostheses: Part 1. Osmosis
    • 10.1007/BF02446293 0140-0118
    • Donaldson P E 1991 Aspects of silicone rubber as an encapsulant for neurological prostheses: part 1. Osmosis Med. Biol. Eng. Comput. 29 34-9
    • (1991) Med. Biol. Eng. Comput. , vol.29 , pp. 34-39
    • Donaldson, P.E.1
  • 8
    • 0026882265 scopus 로고
    • Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
    • DOI 10.1109/10.141202
    • Edell D J, Toi V V, McNeil V M and Clark L D 1992 Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex IEEE Trans. Biomed. Eng. 39 635-43 (Pubitemid 23002705)
    • (1992) IEEE Transactions on Biomedical Engineering , vol.39 , Issue.6 , pp. 635-643
    • Edell, D.J.1    Vo Van Toi2    McNeil, V.M.3    Clark, L.D.4
  • 9
    • 33747807593 scopus 로고    scopus 로고
    • Long-term gliosis around chronically implanted platinum electrodes in the Rhesus macaque motor cortex
    • DOI 10.1016/j.neulet.2006.07.018, PII S0304394006006999
    • Griffith R W and Humphrey D R 2006 Long-term gliosis around chronically implanted platinum electrodes in the Rhesus macaque motor cortex Neurosci. Lett. 406 81-6 (Pubitemid 44278374)
    • (2006) Neuroscience Letters , vol.406 , Issue.1-2 , pp. 81-86
    • Griffith, R.W.1    Humphrey, D.R.2
  • 10
    • 77949497612 scopus 로고    scopus 로고
    • Characterization of parylene C as an encapsulation material for implanted neural prostheses
    • 1552-4973 B
    • Hassler C, von Metzen R P, Ruther P and Stieglitz T 2010 Characterization of parylene C as an encapsulation material for implanted neural prostheses J. Biomed. Mater. Res. B 93 266-74
    • (2010) J. Biomed. Mater. Res. , vol.93 , pp. 266-274
    • Hassler, C.1    Von Metzen, R.P.2    Ruther, P.3    Stieglitz, T.4
  • 12
    • 84861049949 scopus 로고    scopus 로고
    • Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
    • 10.1038/nature11076
    • Hochberg L R et al 2012 Reach and grasp by people with tetraplegia using a neurally controlled robotic arm Nature 485 372-5
    • (2012) Nature , vol.485 , pp. 372-375
    • Hochberg, L.R.1
  • 13
    • 0026735250 scopus 로고
    • A glass silicon composite intracortical electrode array
    • 10.1007/BF02368134
    • Jones K E, Campbell P K and Normann R A 1992 A glass silicon composite intracortical electrode array Ann. Biomed. Eng. 20 423-37
    • (1992) Ann. Biomed. Eng. , vol.20 , pp. 423-437
    • Jones, K.E.1    Campbell, P.K.2    Normann, R.A.3
  • 14
    • 59649105579 scopus 로고    scopus 로고
    • Neural control of computer cursor velocity by decoding motor cortical spiking activity in humans with tetraplegia
    • 10.1088/1741-2560/5/4/010 1741-2552 010
    • Kim S P, Simeral J D, Hochberg L R, Donoghue J P and Black M J 2008 Neural control of computer cursor velocity by decoding motor cortical spiking activity in humans with tetraplegia J. Neural Eng. 5 455-76
    • (2008) J. Neural Eng. , vol.5 , Issue.4 , pp. 455-476
    • Kim, S.P.1    Simeral, J.D.2    Hochberg, L.R.3    Donoghue, J.P.4    Black, M.J.5
  • 15
    • 28444485357 scopus 로고    scopus 로고
    • Biomechanical analysis of silicon microelectrode-induced strain in the brain
    • DOI 10.1088/1741-2560/2/4/003, PII S1741256005005392
    • Lee H, Bellamkonda R V, Sun W and Levenston M E 2005 Biomechanical analysis of silicon microelectrode-induced strain in the brain J. Neural Eng. 2 81-9 (Pubitemid 41740525)
    • (2005) Journal of Neural Engineering , vol.2 , Issue.4 , pp. 81-89
    • Lee, H.1    Bellamkonda, R.V.2    Sun, W.3    Levenston, M.E.4
  • 18
    • 0034655830 scopus 로고    scopus 로고
    • A technique to prevent dural adhesions to chronically implanted microelectrode arrays
    • DOI 10.1016/S0165-0270(00)00159-X, PII S016502700000159X
    • Maynard E M, Fernandez E and Normann R A 2000 A technique to prevent dural adhesions to chronically implanted microelectrode arrays J. Neurosci. Methods 97 93-101 (Pubitemid 30219450)
    • (2000) Journal of Neuroscience Methods , vol.97 , Issue.2 , pp. 93-101
    • Maynard, E.M.1    Fernandez, E.2    Normann, R.A.3
  • 20
    • 70449697992 scopus 로고    scopus 로고
    • Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration
    • 10.1088/1741-2560/6/5/056003 1741-2552 056003
    • McConnell G C, Rees H D, Levey A I, Gutekunst C-A, Gross R E and Bellamkonda R V 2009 Implanted neural electrodes cause chronic, local inflammation that is correlated with local neurodegeneration J. Neural Eng. 6 056003
    • (2009) J. Neural Eng. , vol.6 , Issue.5
    • McConnell, G.C.1    Rees, H.D.2    Levey, A.I.3    Gutekunst, C.-A.4    Gross, R.E.5    Bellamkonda, R.V.6
  • 21
    • 67650917111 scopus 로고    scopus 로고
    • In vivo electrical impedance spectroscopy of tissue reaction to microelectrode arrays
    • 10.1109/TBME.2009.2018457 0018-9294
    • Mercanzini A, Colin P, Bensadoun J C, Bertsch A and Renaud P 2009 In vivo electrical impedance spectroscopy of tissue reaction to microelectrode arrays IEEE Trans. Biomed. Eng. 56 1909-18
    • (2009) IEEE Trans. Biomed. Eng. , vol.56 , pp. 1909-1918
    • Mercanzini, A.1    Colin, P.2    Bensadoun, J.C.3    Bertsch, A.4    Renaud, P.5
  • 23
    • 79957713858 scopus 로고    scopus 로고
    • Corrosion of tungsten microelectrodes used in neural recording applications
    • 10.1016/j.jneumeth.2011.03.012 0165-0270
    • Patrick E, Orazem M E, Sanchez J C and Nishida T 2011 Corrosion of tungsten microelectrodes used in neural recording applications J. Neurosci. Methods 198 158-71
    • (2011) J. Neurosci. Methods , vol.198 , pp. 158-171
    • Patrick, E.1    Orazem, M.E.2    Sanchez, J.C.3    Nishida, T.4
  • 24
    • 26444445003 scopus 로고    scopus 로고
    • Response of brain tissue to chronically implanted neural electrodes
    • DOI 10.1016/j.jneumeth.2005.08.015, PII S0165027005002931
    • Polikov V S, Tresco P A and Reichert W M 2005 Response of brain tissue to chronically implanted neural electrodes J. Neurosci. Methods 148 1-18 (Pubitemid 41423453)
    • (2005) Journal of Neuroscience Methods , vol.148 , Issue.1 , pp. 1-18
    • Polikov, V.S.1    Tresco, P.A.2    Reichert, W.M.3
  • 25
    • 84879600609 scopus 로고    scopus 로고
    • The effect of resveratrol on neurodegeneration and blood brain barrier stability surrounding intracortical microelectrodes
    • 10.1016/j.biomaterials.2013.05.035 0142-9612
    • Potter K A, Buck A C, Self W K, Callanan M E, Sunil S and Capadona J R 2013 The effect of resveratrol on neurodegeneration and blood brain barrier stability surrounding intracortical microelectrodes Biomaterials 34 7001-15
    • (2013) Biomaterials , vol.34 , pp. 7001-7015
    • Potter, K.A.1    Buck, A.C.2    Self, W.K.3    Callanan, M.E.4    Sunil, S.5    Capadona, J.R.6
  • 26
    • 84859135990 scopus 로고    scopus 로고
    • Quantifying long-term microelectrode array functionality using chronic in vivo impedance testing
    • 10.1088/1741-2560/9/2/026028 1741-2552 026028
    • Prasad A and Sanchez J C 2012 Quantifying long-term microelectrode array functionality using chronic in vivo impedance testing J. Neural Eng. 9 026028
    • (2012) J. Neural Eng. , vol.9 , Issue.2
    • Prasad, A.1    Sanchez, J.C.2
  • 27
    • 0026637518 scopus 로고
    • A method for pneumatically inserting an array of penetrating electrodes into cortical tissue
    • 10.1007/BF02368133
    • Rousche P J and Normann R A 1992 A method for pneumatically inserting an array of penetrating electrodes into cortical tissue Ann. Biomed. Eng. 20 413-22
    • (1992) Ann. Biomed. Eng. , vol.20 , pp. 413-422
    • Rousche, P.J.1    Normann, R.A.2
  • 28
    • 0032125652 scopus 로고    scopus 로고
    • Chronic recording capability of the utah intracortical electrode array in cat sensory cortex
    • DOI 10.1016/S0165-0270(98)00031-4, PII S0165027098000314
    • Rousche P J and Normann R A 1998 Chronic recording capability of the Utah intracortical electrode array in cat sensory cortex J. Neurosci. Methods 82 1-15 (Pubitemid 28335467)
    • (1998) Journal of Neuroscience Methods , vol.82 , Issue.1 , pp. 1-15
    • Rousche, P.J.1    Normann, R.A.2
  • 32
    • 0017130723 scopus 로고
    • The ultrastructure of the sheath around chronically implanted electrodes in brain
    • 10.1007/BF01181577 0300-4864
    • Schultz R L and Willey T J 1976 The ultrastructure of the sheath around chronically implanted electrodes in brain J. Neurocytol. 5 621-42
    • (1976) J. Neurocytol. , vol.5 , pp. 621-642
    • Schultz, R.L.1    Willey, T.J.2
  • 33
    • 0034926852 scopus 로고    scopus 로고
    • The astrocyte/meningeal cell interface - A barrier to successful nerve regeneration?
    • DOI 10.1007/s004410100384
    • Shearer M C and Fawcett J W 2001 The astrocyte/meningeal cell interface - a barrier to successful nerve regeneration? Cell Tissue Res. 305 267-73 (Pubitemid 32681903)
    • (2001) Cell and Tissue Research , vol.305 , Issue.2 , pp. 267-273
    • Shearer, M.C.1    Fawcett, J.W.2
  • 38
    • 36949016404 scopus 로고    scopus 로고
    • Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants
    • DOI 10.1088/1741-2560/4/4/007, PII S174125600752611X
    • Williams J C, Hippensteel J A, Dilgen J, Shain W and Kipke D R 2007 Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants J. Neural Eng. 4 410-23 (Pubitemid 350242918)
    • (2007) Journal of Neural Engineering , vol.4 , Issue.4 , pp. 410-423
    • Williams, J.C.1    Hippensteel, J.A.2    Dilgen, J.3    Shain, W.4    Kipke, D.R.5
  • 39
    • 0023141992 scopus 로고
    • Tissue response to potential neuroprosthetic materials implanted subdurally
    • DOI 10.1016/0142-9612(87)90103-7
    • Yuen T G, Agnew W F and Bullara L A 1987 Tissue response to potential neuroprosthetic materials implanted subdurally Biomaterials 8 138-41 (Pubitemid 17032523)
    • (1987) Biomaterials , vol.8 , Issue.2 , pp. 138-141
    • Yuen, T.G.H.1    Agnew, W.F.2    Bullara, L.A.3
  • 40
    • 34247331898 scopus 로고    scopus 로고
    • Dexamethasone-coated neural probes elicit attenuated inflammatory response and neuronal loss compared to uncoated neural probes
    • DOI 10.1016/j.brainres.2007.02.024, PII S0006899307004003
    • Zhong Y and Bellamkonda R V 2007 Dexamethasone-coated neural probes elicit attenuated inflammatory response and neuronal loss compared to uncoated neural probes Brain Res. 1148 15-27 (Pubitemid 46628794)
    • (2007) Brain Research , vol.1148 , Issue.1 , pp. 15-27
    • Zhong, Y.1    Bellamkonda, R.V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.