메뉴 건너뛰기




Volumn 191, Issue , 2014, Pages 813-820

A disposable dry film photoresist-based microcapillary immunosensor chip for rapid detection of Epstein-Barr virus infection

Author keywords

Biofunctionalization; Dry film photoresist; Electrochemical immunosensor; Epstein Barr virus; Microfluidics

Indexed keywords

AMPEROMETRIC DETECTION; BIOFUNCTIONALIZATION; DRY-FILM PHOTORESISTS; ELECTROCHEMICAL IMMUNOSENSORS; ENGINEERING PRINCIPLES; EPSTEIN-BARR VIRUS; MICROFLUIDIC ASSAYS; WAFER-LEVEL PRODUCTION;

EID: 84887834650     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2013.10.019     Document Type: Article
Times cited : (22)

References (37)
  • 1
    • 33747117373 scopus 로고    scopus 로고
    • The origins and the future of microfluidics
    • DOI 10.1038/nature05058, PII NATURE05058
    • G.M. Whitesides The origins and the future of microfluidics Nature 442 2006 368 373 (Pubitemid 44264779)
    • (2006) Nature , vol.442 , Issue.7101 , pp. 368-373
    • Whitesides, G.M.1
  • 2
    • 33747086959 scopus 로고    scopus 로고
    • Microfluidic diagnostic technologies for global public health
    • DOI 10.1038/nature05064, PII NATURE05064
    • P. Yager, T. Edwards, E. Fu, K. Helton, K. Nelson, and M.R. Tam Microfluidic diagnostic technologies for global public health Nature 442 2006 412 418 (Pubitemid 44264785)
    • (2006) Nature , vol.442 , Issue.7101 , pp. 412-418
    • Yager, P.1    Edwards, T.2    Fu, E.3    Helton, K.4    Nelson, K.5    Tam, M.R.6    Weigl, B.H.7
  • 3
    • 79957610323 scopus 로고    scopus 로고
    • Microfabrication of biomedical lab-on-chip devices. A review
    • A.T. Giannitsis Microfabrication of biomedical lab-on-chip devices. A review Est. J. Eng. 17 2011 109 139
    • (2011) Est. J. Eng. , vol.17 , pp. 109-139
    • Giannitsis, A.T.1
  • 4
    • 59349110470 scopus 로고    scopus 로고
    • Comparison of the analytical performance of electrophoresis microchannels fabricated in PDMS, glass, and polyester-toner
    • W.K.T. Coltro, S.M. Lunte, and E. Carrilho Comparison of the analytical performance of electrophoresis microchannels fabricated in PDMS, glass, and polyester-toner Electrophoresis 29 2008 4928 4937
    • (2008) Electrophoresis , vol.29 , pp. 4928-4937
    • Coltro, W.K.T.1    Lunte, S.M.2    Carrilho, E.3
  • 5
    • 34249675900 scopus 로고    scopus 로고
    • SU-8: A photoresist for high-aspect-ratio and 3D submicron lithography
    • A. Del Campo, and C. Greiner SU-8: a photoresist for high-aspect-ratio and 3D submicron lithography J. Micromech. Microeng. 17 2007 R81
    • (2007) J. Micromech. Microeng. , vol.17 , pp. 81
    • Del Campo, A.1    Greiner, C.2
  • 6
    • 73449143825 scopus 로고    scopus 로고
    • Recent developments in PDMS surface modification for microfluidic devices
    • J. Zhou, A.V. Ellis, and N.H. Voelcker Recent developments in PDMS surface modification for microfluidic devices Electrophoresis 31 2010 2 16
    • (2010) Electrophoresis , vol.31 , pp. 2-16
    • Zhou, J.1    Ellis, A.V.2    Voelcker, N.H.3
  • 9
    • 77951115594 scopus 로고    scopus 로고
    • Amperometric micro-immunosensor for rapid substance-P quantification in biological fluids
    • J. Horak, B. Enderle, H. Bakirci, and G.A. Urban Amperometric micro-immunosensor for rapid substance-P quantification in biological fluids IEEE Sens. 2009 1878 1880
    • (2009) IEEE Sens. , pp. 1878-1880
    • Horak, J.1    Enderle, B.2    Bakirci, H.3    Urban, G.A.4
  • 10
    • 71549165122 scopus 로고    scopus 로고
    • Amperometric monitoring of the neuropeptide substance-P level in biological fluids
    • J. Horak, B. Enderle, H. Bakirci, and G.A. Urban Amperometric monitoring of the neuropeptide substance-P level in biological fluids Proc. Chem. 1 2009 1275 1278
    • (2009) Proc. Chem. , vol.1 , pp. 1275-1278
    • Horak, J.1    Enderle, B.2    Bakirci, H.3    Urban, G.A.4
  • 12
    • 34047151768 scopus 로고    scopus 로고
    • Fabrication of a flexible and disposable microreactor using a dry film photoresist
    • Y. Tsai, S. Yang, H. Lee, H. Jen, and Y. Hsieh Fabrication of a flexible and disposable microreactor using a dry film photoresist J. Chin. Chem. Soc. 53 2006 683
    • (2006) J. Chin. Chem. Soc. , vol.53 , pp. 683
    • Tsai, Y.1    Yang, S.2    Lee, H.3    Jen, H.4    Hsieh, Y.5
  • 14
    • 41549137931 scopus 로고    scopus 로고
    • Electrochemical biosensors-sensor principles and architectures
    • D. Grieshaber, R. MacKenzie, J. Voeroes, and E. Reimhult Electrochemical biosensors-sensor principles and architectures Sensors 8 2008 1400 1458
    • (2008) Sensors , vol.8 , pp. 1400-1458
    • Grieshaber, D.1    Mackenzie, R.2    Voeroes, J.3    Reimhult, E.4
  • 15
    • 3843082947 scopus 로고    scopus 로고
    • Routine Epstein-Barr virus diagnostics from the laboratory perspective: Still challenging after 35 years
    • DOI 10.1128/JCM.42.8.3381-3387.2004
    • R.D. Hess Routine Epstein-Barr virus diagnostics from the laboratory perspective: still challenging after 35 years J. Clin. Microbiol. 42 2004 3381 3387 (Pubitemid 39045655)
    • (2004) Journal of Clinical Microbiology , vol.42 , Issue.8 , pp. 3381-3387
    • Hess, R.D.1
  • 16
    • 19544391620 scopus 로고    scopus 로고
    • Epstein-Barr virus infectious mononucleosis
    • M.H. Ebell Epstein-Barr virus infectious mononucleosis Am. Fam. Physician 70 2004 1279 1292
    • (2004) Am. Fam. Physician , vol.70 , pp. 1279-1292
    • Ebell, M.H.1
  • 17
    • 51649124724 scopus 로고    scopus 로고
    • Evaluation of a multiplex flow immunoassay for detection of Epstein-Barr virus-specific antibodies
    • M. Binnicker, D. Jespersen, J. Harring, L. Rollins, and E. Beito Evaluation of a multiplex flow immunoassay for detection of Epstein-Barr virus-specific antibodies Clin. Vaccine Immunol. 15 2008 1410 1413
    • (2008) Clin. Vaccine Immunol. , vol.15 , pp. 1410-1413
    • Binnicker, M.1    Jespersen, D.2    Harring, J.3    Rollins, L.4    Beito, E.5
  • 18
    • 84878931327 scopus 로고    scopus 로고
    • Serological diagnosis of Epstein-Barr virus infection: Problems and solutions
    • M. De Paschale, and P. Clerici Serological diagnosis of Epstein-Barr virus infection: problems and solutions World J. Virol. 1 2012 31 43
    • (2012) World J. Virol. , vol.1 , pp. 31-43
    • De Paschale, M.1    Clerici, P.2
  • 19
    • 79952553854 scopus 로고    scopus 로고
    • Evaluation of four commercial systems for the diagnosis of Epstein-Barr virus primary infections
    • F. de Ory, M.E. Guisasola, J.C. Sanz, and I. García-Bermejo Evaluation of four commercial systems for the diagnosis of Epstein-Barr virus primary infections Clin. Vaccine Immunol. 18 2011 444 448
    • (2011) Clin. Vaccine Immunol. , vol.18 , pp. 444-448
    • De Ory, F.1    Guisasola, M.E.2    Sanz, J.C.3    García-Bermejo, I.4
  • 21
    • 33947610744 scopus 로고    scopus 로고
    • Target delivery in a microfluidic immunosensor
    • DOI 10.1016/j.bios.2006.12.017, PII S0956566306006075
    • J.P. Golden, T.M. Floyd-Smith, D.R. Mott, and F.S. Ligler Target delivery in a microfluidic immunosensor Biosens. Bioelectron. 22 2007 2763 2767 (Pubitemid 46484274)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.11 , pp. 2763-2767
    • Golden, J.P.1    Floyd-Smith, T.M.2    Mott, D.R.3    Ligler, F.S.4
  • 22
    • 0028372590 scopus 로고
    • A novel immunosensor for herpes viruses
    • B. Koenig, and M. Graetzel A novel immunosensor for herpes viruses Anal. Chem. 66 1994 341 344
    • (1994) Anal. Chem. , vol.66 , pp. 341-344
    • Koenig, B.1    Graetzel, M.2
  • 23
    • 65549158260 scopus 로고    scopus 로고
    • Elaboration of optical immunosensors based on the surface plasmon resonance for detecting specific antibodies and antigens of Epstein-Barr virus and human adenovirus
    • N. Nesterova, L. Nosach, S. Zagorodnya, O. Povnitsa, P. Boltovets, and G. Baranova Elaboration of optical immunosensors based on the surface plasmon resonance for detecting specific antibodies and antigens of Epstein-Barr virus and human adenovirus Microbiol. Z. 70 2008 67
    • (2008) Microbiol. Z. , vol.70 , pp. 67
    • Nesterova, N.1    Nosach, L.2    Zagorodnya, S.3    Povnitsa, O.4    Boltovets, P.5    Baranova, G.6
  • 24
    • 33845439562 scopus 로고    scopus 로고
    • Surface plasmon resonance biosensor for direct detection of antibody against Epstein-Barr virus
    • DOI 10.1016/j.bios.2006.04.021, PII S0956566306002260
    • H. Vaisocherová, K. Mrkvová, M. Piliarik, P. Jinoch, M. Šteinbachová, and J. Homola Surface plasmon resonance biosensor for direct detection of antibody against Epstein-Barr virus Biosens. Bioelectron. 22 2007 1020 1026 (Pubitemid 44894890)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.6 , pp. 1020-1026
    • Vaisocherova, H.1    Mrkvova, K.2    Piliarik, M.3    Jinoch, P.4    Steinbachova, M.5    Homola, J.6
  • 25
    • 68249138761 scopus 로고    scopus 로고
    • A full-wafer fabrication process for glass microfluidic chips with integrated electroplated electrodes by direct bonding of dry film resist
    • P. Vulto, T. Huesgen, B. Albrecht, and G. Urban A full-wafer fabrication process for glass microfluidic chips with integrated electroplated electrodes by direct bonding of dry film resist J. Micromech. Microeng. 19 2009 077001
    • (2009) J. Micromech. Microeng. , vol.19 , pp. 077001
    • Vulto, P.1    Huesgen, T.2    Albrecht, B.3    Urban, G.4
  • 26
    • 80052222352 scopus 로고    scopus 로고
    • High-resolution permanent photoresist laminate TMMF for sealed microfluidic structures in biological applications
    • N. Wangler, L. Gutzweiler, K. Kalkandjiev, C. Müller, F. Mayenfels, and H. Reinecke High-resolution permanent photoresist laminate TMMF for sealed microfluidic structures in biological applications J. Micromech. Microeng. 21 2011 095009
    • (2011) J. Micromech. Microeng. , vol.21 , pp. 095009
    • Wangler, N.1    Gutzweiler, L.2    Kalkandjiev, K.3    Müller, C.4    Mayenfels, F.5    Reinecke, H.6
  • 27
    • 14644427845 scopus 로고    scopus 로고
    • Principles of microfluidic actuation by modulation of surface stresses
    • DOI 10.1146/annurev.fluid.36.050802.122052
    • A.A. Darhuber, and S.M. Troian Principles of microfluidic actuation by modulation of surface stresses Annu. Rev. Fluid Mech. 37 2005 425 455 (Pubitemid 40318127)
    • (2005) Annual Review of Fluid Mechanics , vol.37 , pp. 425-455
    • Darhuber, A.A.1    Troian, S.M.2
  • 28
    • 0035971844 scopus 로고    scopus 로고
    • Hydrophobic valves of plasma deposited octafluorocyclobutane in DRIE channels
    • DOI 10.1016/S0925-4005(00)00675-4, PII S0925400500006754
    • H. Andersson, W. Van Der Wijngaart, P. Griss, F. Niklaus, and G. Stemme Hydrophobic valves of plasma deposited octafluorocyclobutane in DRIE channels Sens. Actuators B 75 2001 136 141 (Pubitemid 32408937)
    • (2001) Sensors and Actuators, B: Chemical , vol.75 , Issue.1-2 , pp. 136-141
    • Andersson, H.1    Van Der Wijngaart, W.2    Griss, P.3    Niklaus, F.4    Stemme, G.5
  • 29
    • 29344451451 scopus 로고    scopus 로고
    • Mass transport and surface reactions in microfluidic systems
    • DOI 10.1016/j.ces.2005.06.024, PII S000925090500566X
    • T. Gervais, and K.F. Jensen Mass transport and surface reactions in microfluidic systems Chem. Eng. Sci. 61 2006 1102 1121 (Pubitemid 43005244)
    • (2006) Chemical Engineering Science , vol.61 , Issue.4 , pp. 1102-1121
    • Gervais, T.1    Jensen, K.F.2
  • 30
    • 84894884418 scopus 로고
    • The surface/volume ratio in solid phase assays
    • P. Esser The surface/volume ratio in solid phase assays Thermo Scientific Nunc Bull. 10b 1991 1 5
    • (1991) Thermo Scientific Nunc Bull. , vol.10 B , pp. 1-5
    • Esser, P.1
  • 31
    • 20944444560 scopus 로고    scopus 로고
    • Modeling and optimization of high-sensitivity, low-volume microfluidic-based surface immunoassays
    • DOI 10.1007/s10544-005-1587-y
    • M. Zimmermann, E. Delamarche, M. Wolf, and P. Hunziker Modeling and optimization of high-sensitivity, low-volume microfluidic-based surface immunoassays Biomed. Microdev. 7 2005 99 110 (Pubitemid 40867905)
    • (2005) Biomedical Microdevices , vol.7 , Issue.2 , pp. 99-110
    • Zimmermann, M.1    Delamarche, E.2    Wolf, M.3    Hunziker, P.4
  • 33
    • 0029181831 scopus 로고
    • Mechanism of amide formation by carbodiimide for bioconjugation in aqueous media
    • N. Nakajima, and Y. Ikada Mechanism of amide formation by carbodiimide for bioconjugation in aqueous media Bioconjug. Chem. 6 1995 123 130
    • (1995) Bioconjug. Chem. , vol.6 , pp. 123-130
    • Nakajima, N.1    Ikada, Y.2
  • 34
    • 74249117126 scopus 로고    scopus 로고
    • Semiquantitative study of the EDC/NHS activation of acid terminal groups at modified porous silicon surfaces
    • S. Sam, L. Touahir, J. Salvador Andresa, P. Allongue, J.N. Chazalviel, and A. Gouget-Laemmel Semiquantitative study of the EDC/NHS activation of acid terminal groups at modified porous silicon surfaces Langmuir 26 2009 809 814
    • (2009) Langmuir , vol.26 , pp. 809-814
    • Sam, S.1    Touahir, L.2    Salvador Andresa, J.3    Allongue, P.4    Chazalviel, J.N.5    Gouget-Laemmel, A.6
  • 36
    • 80053305470 scopus 로고    scopus 로고
    • Different EDC/NHS activation mechanisms between PAA and PMAA brushes and the following amidation reactions
    • C. Wang, Q. Yan, H.B. Liu, X.H. Zhou, and S.J. Xiao Different EDC/NHS activation mechanisms between PAA and PMAA brushes and the following amidation reactions Langmuir 27 2011 12058 12068
    • (2011) Langmuir , vol.27 , pp. 12058-12068
    • Wang, C.1    Yan, Q.2    Liu, H.B.3    Zhou, X.H.4    Xiao, S.J.5
  • 37
    • 40449109054 scopus 로고    scopus 로고
    • Electrochemical glucose biosensors
    • DOI 10.1021/cr068123a
    • J. Wang Electrochemical glucose biosensors Chem. Rev. 108 2008 814 825 (Pubitemid 351344456)
    • (2008) Chemical Reviews , vol.108 , Issue.2 , pp. 814-825
    • Wang, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.