메뉴 건너뛰기




Volumn 18, Issue 6, 2013, Pages 446-454

Microfluidic Platforms for Single-Cell Protein Analysis

Author keywords

droplet; heterogeneity; laminar flow; microfluidics; protein analysis; single cell

Indexed keywords

ANALYTICAL TOOL; HETEROGENEITY; MICROFLUIDIC PLATFORMS; MULTIPLE SAMPLES; PROTEIN ANALYSIS; SINGLE CELL PROTEINS; SINGLE CELLS; SINGLECELL ANALYSIS;

EID: 84887523416     PISSN: 22110682     EISSN: 22110690     Source Type: Journal    
DOI: 10.1177/2211068213494389     Document Type: Review
Times cited : (31)

References (82)
  • 1
    • 7444254365 scopus 로고    scopus 로고
    • Oscillations in NF-Kappa B Signaling Control the Dynamics of Gene Expression
    • Nelson D. E.,Ihekwaba A. E. C.,Elliott M., et al.Oscillations in NF-Kappa B Signaling Control the Dynamics of Gene Expression.Science. 2004;306:704-708.
    • (2004) Science , vol.306 , pp. 704-708
    • Nelson, D.E.1    Ihekwaba, A.E.C.2    Elliott, M.3
  • 2
    • 24944586285 scopus 로고    scopus 로고
    • Achieving Stability of Lipopolysaccharide- Induced NF-κB Activation
    • Covert M. W.,Leung T. H.,Gaston J. E., et al.Achieving Stability of Lipopolysaccharide- Induced NF-κB Activation.Science. 2005;309:1854-1857.
    • (2005) Science , vol.309 , pp. 1854-1857
    • Covert, M.W.1    Leung, T.H.2    Gaston, J.E.3
  • 3
    • 67349091738 scopus 로고    scopus 로고
    • The Ups and Downs of p53: Understanding Protein Dynamics in Single Cells
    • Batchelor E.,Loewer A.,Lahav G.The Ups and Downs of p53: Understanding Protein Dynamics in Single Cells.Nat. Rev. Cancer. 2009;9:371-377.
    • (2009) Nat. Rev. Cancer , vol.9 , pp. 371-377
    • Batchelor, E.1    Loewer, A.2    Lahav, G.3
  • 4
    • 33845348652 scopus 로고    scopus 로고
    • Dynamic Single-Cell Analysis for Quantitative Biology
    • Di Carlo D.,Lee L. P.Dynamic Single-Cell Analysis for Quantitative Biology.Anal. Chem. 2006;78:7918-7925.
    • (2006) Anal. Chem , vol.78 , pp. 7918-7925
    • Di Carlo, D.1    Lee, L.P.2
  • 5
    • 44349162752 scopus 로고    scopus 로고
    • Transcriptome-Wide Noise Controls Lineage Choice in Mammalian Progenitor Cells
    • Chang H. H.,Hemberg M.,Barahona M., et al.Transcriptome-Wide Noise Controls Lineage Choice in Mammalian Progenitor Cells.Nature. 2008;453:544-547.
    • (2008) Nature , vol.453 , pp. 544-547
    • Chang, H.H.1    Hemberg, M.2    Barahona, M.3
  • 7
    • 80855128111 scopus 로고    scopus 로고
    • The Quantitative Proteome of a Human Cell Line
    • Beck M.,Schmidt A.,Malmstroem J., et al.The Quantitative Proteome of a Human Cell Line.Mol. Syst. Biol. 2011;7:549.
    • (2011) Mol. Syst. Biol , vol.7 , pp. 549
    • Beck, M.1    Schmidt, A.2    Malmstroem, J.3
  • 8
    • 80052304187 scopus 로고    scopus 로고
    • Integrated Multifunctional Microfluidics for Automated Proteome Analyses
    • Osiri J. K.,Shadpour H.,Witek M. A., et al.Integrated Multifunctional Microfluidics for Automated Proteome Analyses.Top. Curr. Chem. 2011;304:261-294.
    • (2011) Top. Curr. Chem , vol.304 , pp. 261-294
    • Osiri, J.K.1    Shadpour, H.2    Witek, M.A.3
  • 9
    • 77957771797 scopus 로고    scopus 로고
    • Transient Protein-Protein Interactions: Structural, Functional, and Network Properties
    • Perkins J. R.,Diboun I.,Dessailly B. H., et al.Transient Protein-Protein Interactions: Structural, Functional, and Network Properties.Structure. 2010;18:1233-1243.
    • (2010) Structure , vol.18 , pp. 1233-1243
    • Perkins, J.R.1    Diboun, I.2    Dessailly, B.H.3
  • 10
    • 0023989715 scopus 로고
    • Fluorescence-Activated Cell Analysis and Sorting of Viable Mammalian-Cells Based on β-D-galactosidase Activity after Transduction of Escherichia-coli lacz
    • Nolan G. P.,Fiering S.,Nicolas J. F., et al.Fluorescence-Activated Cell Analysis and Sorting of Viable Mammalian-Cells Based on β-D-galactosidase Activity after Transduction of Escherichia-coli lacz.Proc. Natl. Acad. Sci. U. S. A. 1988;85:2603-2607.
    • (1988) Proc. Natl. Acad. Sci. U. S. A , vol.85 , pp. 2603-2607
    • Nolan, G.P.1    Fiering, S.2    Nicolas, J.F.3
  • 11
    • 0036173143 scopus 로고    scopus 로고
    • Simultaneous Measurement of Multiple Active Kinase States Using Polychromatic Flow Cytometry
    • Perez O. D.,Nolan G. P.Simultaneous Measurement of Multiple Active Kinase States Using Polychromatic Flow Cytometry.Nat. Biotechnol. 2002;20:155-162.
    • (2002) Nat. Biotechnol , vol.20 , pp. 155-162
    • Perez, O.D.1    Nolan, G.P.2
  • 12
    • 79955750055 scopus 로고    scopus 로고
    • Single-Cell Mass Cytometry of Differential Immune and Drug Responses across a Human Hematopoietic Continuum
    • Bendall S. C.,Simonds E. F.,Qiu P., et al.Single-Cell Mass Cytometry of Differential Immune and Drug Responses across a Human Hematopoietic Continuum.Science. 2011;332:687-696.
    • (2011) Science , vol.332 , pp. 687-696
    • Bendall, S.C.1    Simonds, E.F.2    Qiu, P.3
  • 13
    • 68849103521 scopus 로고    scopus 로고
    • Mass Cytometry: Technique for Real Time Single Cell Multitarget Immunoassay Based on Inductively Coupled Plasma Time-of-Flight Mass Spectrometry
    • Bandura D. R.,Baranov V. I.,Ornatsky O. I., et al.Mass Cytometry: Technique for Real Time Single Cell Multitarget Immunoassay Based on Inductively Coupled Plasma Time-of-Flight Mass Spectrometry.Anal. Chem. 2009;81:6813-6822.
    • (2009) Anal. Chem , vol.81 , pp. 6813-6822
    • Bandura, D.R.1    Baranov, V.I.2    Ornatsky, O.I.3
  • 14
    • 79958122357 scopus 로고    scopus 로고
    • A Clinical Microchip for Evaluation of Single Immune Cells Reveals High Functional Heterogeneity in Phenotypically Similar T Cells
    • Ma C.,Fan R.,Ahmad H., et al.A Clinical Microchip for Evaluation of Single Immune Cells Reveals High Functional Heterogeneity in Phenotypically Similar T Cells.Nat. Med. 2011;17:738-743.
    • (2011) Nat. Med , vol.17 , pp. 738-743
    • Ma, C.1    Fan, R.2    Ahmad, H.3
  • 15
    • 76149089209 scopus 로고    scopus 로고
    • Integrated Microfluidic Device for Automated Single Cell Analysis Using Electrophoretic Separation and Electrospray Ionization Mass Spectrometry
    • Mellors J. S.,Jorabchi K.,Smith L. M., et al.Integrated Microfluidic Device for Automated Single Cell Analysis Using Electrophoretic Separation and Electrospray Ionization Mass Spectrometry.Anal. Chem. 2010;82:967-973.
    • (2010) Anal. Chem , vol.82 , pp. 967-973
    • Mellors, J.S.1    Jorabchi, K.2    Smith, L.M.3
  • 16
    • 78149398098 scopus 로고    scopus 로고
    • High-Density Micro-Arrays for Mass Spectrometry
    • Urban P. L.,Jefimovs K.,Amantonico A., et al.High-Density Micro-Arrays for Mass Spectrometry.Lab Chip. 2010;10:3206-3209.
    • (2010) Lab Chip , vol.10 , pp. 3206-3209
    • Urban, P.L.1    Jefimovs, K.2    Amantonico, A.3
  • 17
    • 84872031599 scopus 로고    scopus 로고
    • Microfluidics for Manipulating Cells
    • Mu X.,Zheng W.,Sun J., et al.Microfluidics for Manipulating Cells.Small. 2013;9:9-21.
    • (2013) Small , vol.9 , pp. 9-21
    • Mu, X.1    Zheng, W.2    Sun, J.3
  • 18
    • 84856468378 scopus 로고    scopus 로고
    • Microfluidics for Single Cell Analysis
    • Yin H.,Marshall D.Microfluidics for Single Cell Analysis.Curr. Opin. Biotechnol. 2012;23:110-119.
    • (2012) Curr. Opin. Biotechnol , vol.23 , pp. 110-119
    • Yin, H.1    Marshall, D.2
  • 20
    • 84865285684 scopus 로고    scopus 로고
    • Microfluidic Technologies for Studying Synthetic Circuits
    • Lin B.,Levchenko A.Microfluidic Technologies for Studying Synthetic Circuits.Curr. Opin. Chem. Biol. 2012;16:307-317.
    • (2012) Curr. Opin. Chem. Biol , vol.16 , pp. 307-317
    • Lin, B.1    Levchenko, A.2
  • 21
    • 84870564281 scopus 로고    scopus 로고
    • Droplet Microfluidics-A Tool for Single-Cell Analysis
    • Joensson H. N.,Svahn H. A.Droplet Microfluidics-A Tool for Single-Cell Analysis.Angew. Chem. Int. Ed. 2012;51:12176-12192.
    • (2012) Angew. Chem. Int. Ed , vol.51 , pp. 12176-12192
    • Joensson, H.N.1    Svahn, H.A.2
  • 22
    • 84862212456 scopus 로고    scopus 로고
    • Droplet Microfluidics for High-Throughput Biological Assays
    • Guo M. T.,Rotem A.,Heyman J. A., et al.Droplet Microfluidics for High-Throughput Biological Assays.Lab Chip. 2012;12:2146-2155.
    • (2012) Lab Chip , vol.12 , pp. 2146-2155
    • Guo, M.T.1    Rotem, A.2    Heyman, J.A.3
  • 24
    • 24944498780 scopus 로고    scopus 로고
    • Microfluidics: Fluid Physics at the Nanoliter Scale
    • Squires T. M.,Quake S. R.Microfluidics: Fluid Physics at the Nanoliter Scale.Rev. Modern Phys. 2005;77:977-1026.
    • (2005) Rev. Modern Phys , vol.77 , pp. 977-1026
    • Squires, T.M.1    Quake, S.R.2
  • 25
    • 0037328133 scopus 로고    scopus 로고
    • Selective Chemical Treatment of Cellular Microdomains Using Multiple Laminar Streams
    • Takayama S.,Ostuni E.,LeDuc P., et al.Selective Chemical Treatment of Cellular Microdomains Using Multiple Laminar Streams.Chem. Biol. 2003;10:123-130.
    • (2003) Chem. Biol , vol.10 , pp. 123-130
    • Takayama, S.1    Ostuni, E.2    LeDuc, P.3
  • 26
    • 0035963375 scopus 로고    scopus 로고
    • Laminar Flows-Subcellular Positioning of Small Molecules
    • Takayama S.,Ostuni E.,LeDuc P., et al.Laminar Flows-Subcellular Positioning of Small Molecules.Nature. 2001;411:1016-1016.
    • (2001) Nature , vol.411 , pp. 1016
    • Takayama, S.1    Ostuni, E.2    LeDuc, P.3
  • 27
    • 0036696824 scopus 로고    scopus 로고
    • Lateral Propagation of EGF Signaling after Local Stimulation Is Dependent on Receptor Density
    • Sawano A.,Takayama S.,Matsuda M., et al.Lateral Propagation of EGF Signaling after Local Stimulation Is Dependent on Receptor Density.Dev. Cell. 2002;3:245-257.
    • (2002) Dev. Cell , vol.3 , pp. 245-257
    • Sawano, A.1    Takayama, S.2    Matsuda, M.3
  • 28
    • 0035866594 scopus 로고    scopus 로고
    • Generation of Gradients Having Complex Shapes Using Microfluidic Networks
    • Dertinger S. K. W.,Chiu D. T.,Jeon N. L., et al.Generation of Gradients Having Complex Shapes Using Microfluidic Networks.Anal. Chem. 2001;73:1240-1246.
    • (2001) Anal. Chem , vol.73 , pp. 1240-1246
    • Dertinger, S.K.W.1    Chiu, D.T.2    Jeon, N.L.3
  • 29
    • 3242664287 scopus 로고    scopus 로고
    • Dynamic Gene Expression Profiling Using a Microfabricated Living Cell Array
    • Thompson D. M.,King K. R.,Wieder K. J., et al.Dynamic Gene Expression Profiling Using a Microfabricated Living Cell Array.Anal. Chem. 2004;76:4098-4103.
    • (2004) Anal. Chem , vol.76 , pp. 4098-4103
    • Thompson, D.M.1    King, K.R.2    Wieder, K.J.3
  • 30
    • 38549084632 scopus 로고    scopus 로고
    • The Frequency Dependence of Osmo-Adaptation in Saccharomyces cerevisiae
    • Mettetal J. T.,Muzzey D.,Gomez-Uribe C., et al.The Frequency Dependence of Osmo-Adaptation in Saccharomyces cerevisiae.Science. 2008;319:482-484.
    • (2008) Science , vol.319 , pp. 482-484
    • Mettetal, J.T.1    Muzzey, D.2    Gomez-Uribe, C.3
  • 31
    • 84857766780 scopus 로고    scopus 로고
    • Diverse Sensitivity Thresholds in Dynamic Signaling Responses by Social Amoebae
    • Wang C. J.,Bergmann A.,Lin B., et al.Diverse Sensitivity Thresholds in Dynamic Signaling Responses by Social Amoebae.Sci. Signal. 2012;5:ra17.
    • (2012) Sci. Signal , vol.5
    • Wang, C.J.1    Bergmann, A.2    Lin, B.3
  • 33
    • 77954541844 scopus 로고    scopus 로고
    • Single-Cell NF-κB Dynamics Reveal Digital Activation and Analogue Information Processing
    • Tay S.,Hughey J. J.,Lee T. K., et al.Single-Cell NF-κB Dynamics Reveal Digital Activation and Analogue Information Processing.Nature. 2010;466:267-271.
    • (2010) Nature , vol.466 , pp. 267-271
    • Tay, S.1    Hughey, J.J.2    Lee, T.K.3
  • 34
    • 66149113216 scopus 로고    scopus 로고
    • Chemistry and Biology in Femtoliter and Picoliter Volume Droplets
    • Chiu D. T.,Lorenz R. M.Chemistry and Biology in Femtoliter and Picoliter Volume Droplets.Acc. Chem. Res. 2009;42:649-658.
    • (2009) Acc. Chem. Res , vol.42 , pp. 649-658
    • Chiu, D.T.1    Lorenz, R.M.2
  • 35
    • 38849155318 scopus 로고    scopus 로고
    • Droplet Microfluidics
    • Teh S.-Y.,Lin R.,Hung L.-H., et al.Droplet Microfluidics.Lab Chip. 2008;8:198-220.
    • (2008) Lab Chip , vol.8 , pp. 198-220
    • Teh, S.-Y.1    Lin, R.2    Hung, L.-H.3
  • 36
    • 84856748588 scopus 로고    scopus 로고
    • Teaching Single-Cell Digital Analysis Using Droplet-Based Microfluidics
    • Najah M.,Griffiths A. D.,Ryckelynck M.Teaching Single-Cell Digital Analysis Using Droplet-Based Microfluidics.Anal. Chem. 2012;84:1202-1209.
    • (2012) Anal. Chem , vol.84 , pp. 1202-1209
    • Najah, M.1    Griffiths, A.D.2    Ryckelynck, M.3
  • 37
    • 15444376608 scopus 로고    scopus 로고
    • Selective Encapsulation of Single Cells and Subcellular Organelles into Picoliter- and Femtoliter-Volume Droplets
    • He M. Y.,Edgar J. S.,Jeffries G. D. M., et al.Selective Encapsulation of Single Cells and Subcellular Organelles into Picoliter- and Femtoliter-Volume Droplets.Anal. Chem. 2005;77:1539-1544.
    • (2005) Anal. Chem , vol.77 , pp. 1539-1544
    • He, M.Y.1    Edgar, J.S.2    Jeffries, G.D.M.3
  • 38
    • 70149096883 scopus 로고    scopus 로고
    • Droplet Microfluidic Technology for Single-Cell High-Throughput Screening
    • Brouzes E.,Medkova M.,Savenelli N., et al.Droplet Microfluidic Technology for Single-Cell High-Throughput Screening.Proc. Natl. Acad. Sci. U. S. A. 2009;106:14195-14200.
    • (2009) Proc. Natl. Acad. Sci. U. S. A , vol.106 , pp. 14195-14200
    • Brouzes, E.1    Medkova, M.2    Savenelli, N.3
  • 39
    • 67649973848 scopus 로고    scopus 로고
    • Fluorescence-Activated Droplet Sorting (FADS): Efficient Microfluidic Cell Sorting Based on Enzymatic Activity
    • Baret J.-C.,Miller O. J.,Taly V., et al.Fluorescence-Activated Droplet Sorting (FADS): Efficient Microfluidic Cell Sorting Based on Enzymatic Activity.Lab Chip. 2009;9:1850-1858.
    • (2009) Lab Chip , vol.9 , pp. 1850-1858
    • Baret, J.-C.1    Miller, O.J.2    Taly, V.3
  • 40
    • 46149091744 scopus 로고    scopus 로고
    • Drop-Based Microfluidic Devices for Encapsulation of Single Cells
    • Koester S.,Angile F. E.,Duan H., et al.Drop-Based Microfluidic Devices for Encapsulation of Single Cells.Lab Chip. 2008;8:1110-1115.
    • (2008) Lab Chip , vol.8 , pp. 1110-1115
    • Koester, S.1    Angile, F.E.2    Duan, H.3
  • 41
    • 43149111583 scopus 로고    scopus 로고
    • Droplet-Based Microfluidic Platforms for the Encapsulation and Screening of Mammalian Cells and Multicellular Organisms
    • Clausell-Tormos J.,Lieber D.,Baret J.-C., et al.Droplet-Based Microfluidic Platforms for the Encapsulation and Screening of Mammalian Cells and Multicellular Organisms.Chem. Biol. 2008;15:427-437.
    • (2008) Chem. Biol , vol.15 , pp. 427-437
    • Clausell-Tormos, J.1    Lieber, D.2    Baret, J.-C.3
  • 42
    • 43949083044 scopus 로고    scopus 로고
    • Development of Quantitative Cell-Based Enzyme Assays in Microdroplets
    • Huebner A.,Olguin L. F.,Bratton D., et al.Development of Quantitative Cell-Based Enzyme Assays in Microdroplets.Anal. Chem. 2008;80:3890-3896.
    • (2008) Anal. Chem , vol.80 , pp. 3890-3896
    • Huebner, A.1    Olguin, L.F.2    Bratton, D.3
  • 43
    • 70349782198 scopus 로고    scopus 로고
    • Detection and Analysis of Low-Abundance Cell-Surface Biomarkers Using Enzymatic Amplification in Microfluidic Droplets
    • Joensson H. N.,Samuels M. L.,Brouzes E. R., et al.Detection and Analysis of Low-Abundance Cell-Surface Biomarkers Using Enzymatic Amplification in Microfluidic Droplets.Angew. Chem. Int. Ed. 2009;48:2518-2521.
    • (2009) Angew. Chem. Int. Ed , vol.48 , pp. 2518-2521
    • Joensson, H.N.1    Samuels, M.L.2    Brouzes, E.R.3
  • 44
    • 84859341988 scopus 로고    scopus 로고
    • A Practical Guide for the Fabrication of Microfluidic Devices Using Glass and Silicon
    • Iliescu C.,Taylor H.,Avram M., et al.A Practical Guide for the Fabrication of Microfluidic Devices Using Glass and Silicon.Biomicrofluidics. 2012;6:16505-1650516.
    • (2012) Biomicrofluidics , vol.6 , pp. 16505-1650516
    • Iliescu, C.1    Taylor, H.2    Avram, M.3
  • 45
    • 33751392855 scopus 로고    scopus 로고
    • Applications of Microfluidics in Chemical Biology
    • Weibel D. B.,Whitesides G. M.Applications of Microfluidics in Chemical Biology.Curr. Opin. Chem. Biol. 2006;10:584-591.
    • (2006) Curr. Opin. Chem. Biol , vol.10 , pp. 584-591
    • Weibel, D.B.1    Whitesides, G.M.2
  • 46
    • 77956328100 scopus 로고    scopus 로고
    • Programmable Diagnostic Devices Made from Paper and Tape
    • Martinez A. W.,Phillips S. T.,Nie Z., et al.Programmable Diagnostic Devices Made from Paper and Tape.Lab Chip. 2010;10:2499-2504.
    • (2010) Lab Chip , vol.10 , pp. 2499-2504
    • Martinez, A.W.1    Phillips, S.T.2    Nie, Z.3
  • 47
    • 77749333437 scopus 로고    scopus 로고
    • Soft Lithography for Micro- and Nanoscale Patterning
    • Qin D.,Xia Y.,Whitesides G. M.Soft Lithography for Micro- and Nanoscale Patterning.Nat. Protocols. 2010;5:491-502.
    • (2010) Nat. Protocols , vol.5 , pp. 491-502
    • Qin, D.1    Xia, Y.2    Whitesides, G.M.3
  • 49
    • 0347134477 scopus 로고    scopus 로고
    • Microfluidic Devices Fabricated in Poly(dimethylsiloxane) for Biological Studies
    • Sia S. K.,Whitesides G. M.Microfluidic Devices Fabricated in Poly(dimethylsiloxane) for Biological Studies.Electrophoresis. 2003;24:3563-3576.
    • (2003) Electrophoresis , vol.24 , pp. 3563-3576
    • Sia, S.K.1    Whitesides, G.M.2
  • 50
    • 0033988843 scopus 로고    scopus 로고
    • Fabrication of Microfluidic Systems in Poly(dimethylsiloxane)
    • McDonald J. C.,Duffy D. C.,Anderson J. R., et al.Fabrication of Microfluidic Systems in Poly(dimethylsiloxane).Electrophoresis. 2000;21:27-40.
    • (2000) Electrophoresis , vol.21 , pp. 27-40
    • McDonald, J.C.1    Duffy, D.C.2    Anderson, J.R.3
  • 51
    • 0035984039 scopus 로고    scopus 로고
    • Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
    • McDonald J. C.,Whitesides G. M.Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices.Acc. Chem. Res. 2002;35:491-499.
    • (2002) Acc. Chem. Res , vol.35 , pp. 491-499
    • McDonald, J.C.1    Whitesides, G.M.2
  • 52
    • 0032703889 scopus 로고    scopus 로고
    • Patterning Proteins and Cells Using Soft Lithography
    • Kane R. S.,Takayama S.,Ostuni E., et al.Patterning Proteins and Cells Using Soft Lithography.Biomaterials. 1999;20:2363-2376.
    • (1999) Biomaterials , vol.20 , pp. 2363-2376
    • Kane, R.S.1    Takayama, S.2    Ostuni, E.3
  • 53
    • 33846246380 scopus 로고    scopus 로고
    • PDMS Absorption of Small Molecules and Consequences in Microfluidic Applications
    • Toepke M. W.,Beebe D. J.PDMS Absorption of Small Molecules and Consequences in Microfluidic Applications.Lab Chip. 2006;6:1484-1486.
    • (2006) Lab Chip , vol.6 , pp. 1484-1486
    • Toepke, M.W.1    Beebe, D.J.2
  • 54
    • 33845782140 scopus 로고    scopus 로고
    • Solvent Resistant Microfluidic DNA Synthesizer
    • Huang Y. Y.,Castrataro P.,Lee C. C.;, et al.Solvent Resistant Microfluidic DNA Synthesizer.Lab Chip. 2007;7:24-26.
    • (2007) Lab Chip , vol.7 , pp. 24-26
    • Huang, Y.Y.1    Castrataro, P.2    Lee, C.C.3
  • 55
    • 4444367423 scopus 로고    scopus 로고
    • Chemical Cytometry on a Picoliter-Scale Integrated Microfluidic Chip
    • Wu H. K.,Wheeler A.,Zare R. N.Chemical Cytometry on a Picoliter-Scale Integrated Microfluidic Chip.Proc. Natl. Acad. Sci. U. S. A. 2004;101:12809-12813.
    • (2004) Proc. Natl. Acad. Sci. U. S. A , vol.101 , pp. 12809-12813
    • Wu, H.K.1    Wheeler, A.2    Zare, R.N.3
  • 56
    • 0037102392 scopus 로고    scopus 로고
    • A Microfabrication-Based Dynamic Array Cytometer
    • Voldman J.,Gray M. L.,Toner M., et al.A Microfabrication-Based Dynamic Array Cytometer.Anal. Chem. 2002;74:3984-3990.
    • (2002) Anal. Chem , vol.74 , pp. 3984-3990
    • Voldman, J.1    Gray, M.L.2    Toner, M.3
  • 57
    • 0037164801 scopus 로고    scopus 로고
    • Realization of Hollow SiO2 Micronozzles for Electrical Measurements on Living Cells
    • Lehnert T.,Gijs M. A. M.,Netzer R., et al.Realization of Hollow SiO2 Micronozzles for Electrical Measurements on Living Cells.Appl. Phys. Lett. 2002;81:5063-5065.
    • (2002) Appl. Phys. Lett , vol.81 , pp. 5063-5065
    • Lehnert, T.1    Gijs, M.A.M.2    Netzer, R.3
  • 59
    • 0035142860 scopus 로고    scopus 로고
    • High-Speed Separation System of Randomly Suspended Single Living Cells by Laser Trap and Dielectrophoresis
    • Arai F.,Ichikawa A.,Ogawa M., et al.High-Speed Separation System of Randomly Suspended Single Living Cells by Laser Trap and Dielectrophoresis.Electrophoresis. 2001;22:283-288.
    • (2001) Electrophoresis , vol.22 , pp. 283-288
    • Arai, F.1    Ichikawa, A.2    Ogawa, M.3
  • 60
    • 79952668680 scopus 로고    scopus 로고
    • A First Step Towards Practical Single Cell Proteomics: A Microfluidic Antibody Capture Chip with TIRF Detection
    • Salehi-Reyhani A.,Kaplinsky J.,Burgin E., et al.A First Step Towards Practical Single Cell Proteomics: A Microfluidic Antibody Capture Chip with TIRF Detection.Lab Chip. 2011;11:1256-1261.
    • (2011) Lab Chip , vol.11 , pp. 1256-1261
    • Salehi-Reyhani, A.1    Kaplinsky, J.2    Burgin, E.3
  • 61
    • 37549002543 scopus 로고    scopus 로고
    • Isolation of Rare Circulating Tumour Cells in Cancer Patients by Microchip Technology
    • Nagrath S.,Sequist L. V.,Maheswaran S., et al.Isolation of Rare Circulating Tumour Cells in Cancer Patients by Microchip Technology.Nature. 2007;450:1235-1230.
    • (2007) Nature , vol.450 , pp. 1230-1235
    • Nagrath, S.1    Sequist, L.V.2    Maheswaran, S.3
  • 62
    • 84864241585 scopus 로고    scopus 로고
    • Microfluidically-Unified Cell Culture, Sample Preparation, Imaging and Flow Cytometry for Measurement of Cell Signaling Pathways with Single Cell Resolution
    • Wu M.,Perroud T. D.,Srivastava N., et al.Microfluidically-Unified Cell Culture, Sample Preparation, Imaging and Flow Cytometry for Measurement of Cell Signaling Pathways with Single Cell Resolution.Lab Chip. 2012;12:2823-2831.
    • (2012) Lab Chip , vol.12 , pp. 2823-2831
    • Wu, M.1    Perroud, T.D.2    Srivastava, N.3
  • 63
    • 84875842721 scopus 로고    scopus 로고
    • Microfluidic Platforms for RNA Interference Screening of Virus-Host Interactions
    • Schudel B. R.,Harmon B.,Abhyankar V. V., et al.Microfluidic Platforms for RNA Interference Screening of Virus-Host Interactions.Lab Chip. 2013;13:811-817.
    • (2013) Lab Chip , vol.13 , pp. 811-817
    • Schudel, B.R.1    Harmon, B.2    Abhyankar, V.V.3
  • 64
    • 77955102352 scopus 로고    scopus 로고
    • Quantifying E-coli Proteome and Transcriptome with Single-Molecule Sensitivity in Single Cells
    • Taniguchi Y.,Choi P. J.,Li G.-W., et al.Quantifying E-coli Proteome and Transcriptome with Single-Molecule Sensitivity in Single Cells.Science. 2010;329:533-538.
    • (2010) Science , vol.329 , pp. 533-538
    • Taniguchi, Y.1    Choi, P.J.2    Li, G.-W.3
  • 65
    • 27244432019 scopus 로고    scopus 로고
    • Single Cell Manipulation, Analytics, and Label-Free Protein Detection in Microfluidic Devices for Systems Nanobiology
    • Hellmich W.,Pelargus C.,Leffhalm K., et al.Single Cell Manipulation, Analytics, and Label-Free Protein Detection in Microfluidic Devices for Systems Nanobiology.Electrophoresis. 2005;26:3689-3696.
    • (2005) Electrophoresis , vol.26 , pp. 3689-3696
    • Hellmich, W.1    Pelargus, C.2    Leffhalm, K.3
  • 66
    • 33846682918 scopus 로고    scopus 로고
    • Counting Low-Copy Number Proteins in a Single Cell
    • Huang B.,Wu H.,Bhaya D., et al.Counting Low-Copy Number Proteins in a Single Cell.Science. 2007;315:81-84.
    • (2007) Science , vol.315 , pp. 81-84
    • Huang, B.1    Wu, H.2    Bhaya, D.3
  • 67
    • 65649109549 scopus 로고    scopus 로고
    • Fully Integrated Microfluidic Platform Enabling Automated Phosphoprofiling of Macrophage Response
    • Srivastava N.,Brennan J. S.,Renzi R. F., et al.Fully Integrated Microfluidic Platform Enabling Automated Phosphoprofiling of Macrophage Response.Anal. Chem. 2009;81:3261-3269.
    • (2009) Anal. Chem , vol.81 , pp. 3261-3269
    • Srivastava, N.1    Brennan, J.S.2    Renzi, R.F.3
  • 68
    • 50049123323 scopus 로고    scopus 로고
    • Microfluidic-Based Cell Sorting of Francisella tularensis Infected Macrophages Using Optical Forces
    • Perroud T. D.,Kaiser J. N.,Sy J. C., et al.Microfluidic-Based Cell Sorting of Francisella tularensis Infected Macrophages Using Optical Forces.Anal. Chem. 2008;80:6365-6372.
    • (2008) Anal. Chem , vol.80 , pp. 6365-6372
    • Perroud, T.D.1    Kaiser, J.N.2    Sy, J.C.3
  • 69
    • 84863033996 scopus 로고    scopus 로고
    • Qualitative and Quantitative Analysis of Tumor Cell Metabolism via Stable Isotope Labeling Assisted Microfluidic Chip Electrospray Ionization Mass Spectrometry
    • Chen Q.,Wu J.,Zhang Y., et al.Qualitative and Quantitative Analysis of Tumor Cell Metabolism via Stable Isotope Labeling Assisted Microfluidic Chip Electrospray Ionization Mass Spectrometry.Anal. Chem. 2012;84:1695-1701.
    • (2012) Anal. Chem , vol.84 , pp. 1695-1701
    • Chen, Q.1    Wu, J.2    Zhang, Y.3
  • 70
    • 84860464109 scopus 로고    scopus 로고
    • Mass Spectrometry-Based Proteomics: Existing Capabilities and Future Directions
    • Angel T. E.,Aryal U. K.,Hengel S. M., et al.Mass Spectrometry-Based Proteomics: Existing Capabilities and Future Directions.Chem. Soc. Rev. 2012;41:3912-3928.
    • (2012) Chem. Soc. Rev , vol.41 , pp. 3912-3928
    • Angel, T.E.1    Aryal, U.K.2    Hengel, S.M.3
  • 71
    • 24044453695 scopus 로고    scopus 로고
    • A Microfluidic Chemostat for Experiments with Bacterial and Yeast Cells
    • Groisman A.,Lobo C.,Cho H. J., et al.A Microfluidic Chemostat for Experiments with Bacterial and Yeast Cells.Nat. Methods. 2005;2:685-689.
    • (2005) Nat. Methods , vol.2 , pp. 685-689
    • Groisman, A.1    Lobo, C.2    Cho, H.J.3
  • 72
    • 36448935709 scopus 로고    scopus 로고
    • Versatile, Fully Automated, Microfluidic Cell Culture System
    • Gomez-Sjoberg R.,Leyrat A. A.,Pirone D. M., et al.Versatile, Fully Automated, Microfluidic Cell Culture System.Anal. Chem. 2007;79:8557-8563.
    • (2007) Anal. Chem , vol.79 , pp. 8557-8563
    • Gomez-Sjoberg, R.1    Leyrat, A.A.2    Pirone, D.M.3
  • 73
    • 77955359943 scopus 로고    scopus 로고
    • A Microfluidic Platform for Systems Pathology: Multiparameter Single-Cell Signaling Measurements of Clinical Brain Tumor Specimens
    • Sun J.,Masterman-Smith M. D.,Graham N. A., et al.A Microfluidic Platform for Systems Pathology: Multiparameter Single-Cell Signaling Measurements of Clinical Brain Tumor Specimens.Cancer Res. 2010;70:6128-6138.
    • (2010) Cancer Res , vol.70 , pp. 6128-6138
    • Sun, J.1    Masterman-Smith, M.D.2    Graham, N.A.3
  • 74
    • 59649102718 scopus 로고    scopus 로고
    • Isotropically Etched Radial Micropore for Cell Concentration, Immobilization, and Picodroplet Generation
    • Perroud T. D.,Meagher R. J.,Kanouff M. P., et al.Isotropically Etched Radial Micropore for Cell Concentration, Immobilization, and Picodroplet Generation.Lab Chip. 2009;9:507-515.
    • (2009) Lab Chip , vol.9 , pp. 507-515
    • Perroud, T.D.1    Meagher, R.J.2    Kanouff, M.P.3
  • 75
    • 84875445708 scopus 로고    scopus 로고
    • Single-Cell Measurements of IgE-Mediated FcepsilonRI Signaling Using an Integrated Microfluidic Platform
    • Liu Y.,Barua D.,Liu P., et al.Single-Cell Measurements of IgE-Mediated FcepsilonRI Signaling Using an Integrated Microfluidic Platform.PLoS One. 2013;8:e60159-e60159.
    • (2013) PLoS One , vol.8
    • Liu, Y.1    Barua, D.2    Liu, P.3
  • 76
    • 57449087445 scopus 로고    scopus 로고
    • Single-Cell Chemical Lysis Method for Analyses of Intracellular Molecules Using an Array of Picoliter-Scale Microwells
    • Sasuga Y.,Iwasawa T.,Terada K., et al.Single-Cell Chemical Lysis Method for Analyses of Intracellular Molecules Using an Array of Picoliter-Scale Microwells.Anal. Chem. 2008;80:9141-9149.
    • (2008) Anal. Chem , vol.80 , pp. 9141-9149
    • Sasuga, Y.1    Iwasawa, T.2    Terada, K.3
  • 77
    • 6044250292 scopus 로고    scopus 로고
    • Single-Cell Chemical Lysis in Picoliter-Scale Closed Volumes Using a Microfabricated Device
    • Irimia D.,Tompkins R. G.,Toner M.Single-Cell Chemical Lysis in Picoliter-Scale Closed Volumes Using a Microfabricated Device.Anal. Chem. 2004;76:6137-6143.
    • (2004) Anal. Chem , vol.76 , pp. 6137-6143
    • Irimia, D.1    Tompkins, R.G.2    Toner, M.3
  • 78
    • 0242385640 scopus 로고    scopus 로고
    • Microfluidic Devices for the High-Throughput Chemical Analysis of Cells
    • McClain M. A.,Culbertson C. T.,Jacobson S. C., et al.Microfluidic Devices for the High-Throughput Chemical Analysis of Cells.Anal. Chem. 2003;75:5646-5655.
    • (2003) Anal. Chem , vol.75 , pp. 5646-5655
    • McClain, M.A.1    Culbertson, C.T.2    Jacobson, S.C.3
  • 79
    • 4444314970 scopus 로고    scopus 로고
    • Microfabricated System for Parallel Single-Cell Capillary Electrophoresis
    • Munce N. R.,Li J. Z.,Herman P. R., et al.Microfabricated System for Parallel Single-Cell Capillary Electrophoresis.Anal. Chem. 2004;76:4983-4989.
    • (2004) Anal. Chem , vol.76 , pp. 4983-4989
    • Munce, N.R.1    Li, J.Z.2    Herman, P.R.3
  • 80
    • 40049097268 scopus 로고    scopus 로고
    • Examination of Laser Microbeam Cell Lysis in a PDMS Microfluidic Channel Using Time-Resolved Imaging
    • Quinto-Su P. A.,Lai H.-H.,Yoon H. H., et al.Examination of Laser Microbeam Cell Lysis in a PDMS Microfluidic Channel Using Time-Resolved Imaging.Lab Chip. 2008;8:408-414.
    • (2008) Lab Chip , vol.8 , pp. 408-414
    • Quinto-Su, P.A.1    Lai, H.-H.2    Yoon, H.H.3
  • 81
    • 79952636514 scopus 로고    scopus 로고
    • Continuous Analysis of Dye-Loaded, Single Cells on a Microfluidic Chip
    • Phillips K. S.,Lai H. H.,Johnson E., et al.Continuous Analysis of Dye-Loaded, Single Cells on a Microfluidic Chip.Lab Chip. 2011;11:1333-1341.
    • (2011) Lab Chip , vol.11 , pp. 1333-1341
    • Phillips, K.S.1    Lai, H.H.2    Johnson, E.3
  • 82
    • 77952738607 scopus 로고    scopus 로고
    • Quantification of Taurine and Amino Acids in Mice Single Fibrosarcoma Cell by Microchip Electrophoresis Coupled with Chemiluminescence Detection
    • Ye F.,Huang Y.,Xu Q.;, et al.Quantification of Taurine and Amino Acids in Mice Single Fibrosarcoma Cell by Microchip Electrophoresis Coupled with Chemiluminescence Detection.Electrophoresis. 2010;31:1630-1636.
    • (2010) Electrophoresis , vol.31 , pp. 1630-1636
    • Ye, F.1    Huang, Y.2    Xu, Q.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.