메뉴 건너뛰기




Volumn 45, Issue 9, 2013, Pages 3209-3213

Perfusion defatting at subnormothermic temperatures in steatotic rat livers

Author keywords

[No Author keywords available]

Indexed keywords

OXYGEN; TRIACYLGLYCEROL; VERY LOW DENSITY LIPOPROTEIN;

EID: 84887053135     PISSN: 00411345     EISSN: 18732623     Source Type: Journal    
DOI: 10.1016/j.transproceed.2013.05.005     Document Type: Article
Times cited : (44)

References (20)
  • 1
    • 63449140685 scopus 로고    scopus 로고
    • Trends in organ donation and transplantation in the United States, 1998-2007
    • R.A. Wolfe, R.M. Merion, and E.C. Roys Trends in organ donation and transplantation in the United States, 1998-2007 Am J Transplant 9 4 pt 2 2009 869 878
    • (2009) Am J Transplant , vol.9 , Issue.4 PART 2 , pp. 869-878
    • Wolfe, R.A.1    Merion, R.M.2    Roys, E.C.3
  • 2
    • 58249084969 scopus 로고    scopus 로고
    • Report of the Paris consensus meeting on expanded criteria donors in liver transplantation
    • F. Durand, J.F. Renz, and B. Alkofer Report of the Paris consensus meeting on expanded criteria donors in liver transplantation Liver Transpl 14 12 2008 1694 1707
    • (2008) Liver Transpl , vol.14 , Issue.12 , pp. 1694-1707
    • Durand, F.1    Renz, J.F.2    Alkofer, B.3
  • 3
    • 63449117990 scopus 로고    scopus 로고
    • Liver and intestine transplantation in the United States 1998-2007
    • C.L. Berg, D.E. Steffick, and E.B. Edwards Liver and intestine transplantation in the United States 1998-2007 Am J Transplant 9 4 pt 2 2009 907 931
    • (2009) Am J Transplant , vol.9 , Issue.4 PART 2 , pp. 907-931
    • Berg, C.L.1    Steffick, D.E.2    Edwards, E.B.3
  • 4
    • 70350539112 scopus 로고    scopus 로고
    • Preconditioning, organ preservation, and postconditioning to prevent ischemia-reperfusion injury to the liver
    • O. de Rougemont, K. Lehmann, and P.A. Clavien Preconditioning, organ preservation, and postconditioning to prevent ischemia-reperfusion injury to the liver Liver Transpl 15 2009 1172 1182
    • (2009) Liver Transpl , vol.15 , pp. 1172-1182
    • De Rougemont, O.1    Lehmann, K.2    Clavien, P.A.3
  • 5
    • 79961062068 scopus 로고    scopus 로고
    • Hepatic steatosis and normothermic perfusion-preliminary experiments in a porcine model
    • R.W. Jamieson, M. Zilvetti, and D. Roy Hepatic steatosis and normothermic perfusion-preliminary experiments in a porcine model Transplantation 92 3 2011 289 295
    • (2011) Transplantation , vol.92 , Issue.3 , pp. 289-295
    • Jamieson, R.W.1    Zilvetti, M.2    Roy, D.3
  • 6
    • 64049110277 scopus 로고    scopus 로고
    • Subnormothermic machine perfusion protects steatotic livers against preservation injury: A potential for donor pool increase?
    • M. Vairetti, A. Ferrigno, and F. Carlucci Subnormothermic machine perfusion protects steatotic livers against preservation injury: a potential for donor pool increase? Liver Transpl 15 1 2009 20 29
    • (2009) Liver Transpl , vol.15 , Issue.1 , pp. 20-29
    • Vairetti, M.1    Ferrigno, A.2    Carlucci, F.3
  • 7
    • 84859744334 scopus 로고    scopus 로고
    • Decreased apoptosis in fatty livers submitted to subnormothermic machine-perfusion respect to cold storage
    • E. Boncompagni, E. Gini, and A. Ferrigno Decreased apoptosis in fatty livers submitted to subnormothermic machine-perfusion respect to cold storage Eur J Histochem 55 4 2011 e40
    • (2011) Eur J Histochem , vol.55 , Issue.4 , pp. 40
    • Boncompagni, E.1    Gini, E.2    Ferrigno, A.3
  • 8
    • 34247261587 scopus 로고    scopus 로고
    • Preservation of steatotic livers: A comparison between cold storage and machine perfusion preservation
    • M. Bessems, B.M. Doorschodt, and J.L. Kolkert Preservation of steatotic livers: a comparison between cold storage and machine perfusion preservation Liver Transpl 13 4 2007 497 504
    • (2007) Liver Transpl , vol.13 , Issue.4 , pp. 497-504
    • Bessems, M.1    Doorschodt, B.M.2    Kolkert, J.L.3
  • 9
    • 77952274609 scopus 로고    scopus 로고
    • Machine perfusion of the liver: Past, present and future
    • D. Monbaliu, and J. Brassil Machine perfusion of the liver: past, present and future Curr Opin Organ Transplant 15 2 2010 160 166
    • (2010) Curr Opin Organ Transplant , vol.15 , Issue.2 , pp. 160-166
    • Monbaliu, D.1    Brassil, J.2
  • 10
    • 68249087183 scopus 로고    scopus 로고
    • Normothermic perfusion: A new paradigm for organ preservation
    • J. Brockmann, S. Reddy, and C. Coussios Normothermic perfusion: a new paradigm for organ preservation Ann Surg 259 1 2009 1 6
    • (2009) Ann Surg , vol.259 , Issue.1 , pp. 1-6
    • Brockmann, J.1    Reddy, S.2    Coussios, C.3
  • 11
    • 81855166935 scopus 로고    scopus 로고
    • Superior preservation of DCD livers with continuous normothermic perfusion
    • C. Fondevila, A.J. Hessheimer, and M.H. Masthuis Superior preservation of DCD livers with continuous normothermic perfusion Ann Surg 254 6 2011 1000 1007
    • (2011) Ann Surg , vol.254 , Issue.6 , pp. 1000-1007
    • Fondevila, C.1    Hessheimer, A.J.2    Masthuis, M.H.3
  • 12
    • 68249104194 scopus 로고    scopus 로고
    • Metabolic preconditioning of donor organs: Defatting fatty livers by normothermic perfusion ex vivo
    • D. Nagrath, H. Xu, and Y. Tanimura Metabolic preconditioning of donor organs: defatting fatty livers by normothermic perfusion ex vivo Metab Eng 11 4-5 2009 274 283
    • (2009) Metab Eng , vol.11 , Issue.45 , pp. 274-283
    • Nagrath, D.1    Xu, H.2    Tanimura, Y.3
  • 13
    • 84864027010 scopus 로고    scopus 로고
    • Addressing the liver organ donor shortage with ex vivo organ perfusion
    • 279-98
    • M. Izamis, T. Berendsen, and K. Uygun Addressing the liver organ donor shortage with ex vivo organ perfusion J Healthcare Engineer 3 2012 279-98
    • (2012) J Healthcare Engineer , vol.3
    • Izamis, M.1    Berendsen, T.2    Uygun, K.3
  • 14
    • 79952186588 scopus 로고    scopus 로고
    • Machine perfusion at 20 C reduces preservation damage to livers from non-heart beating donors
    • A. Ferrigno, V. Rizzo, and E. Boncompagni Machine perfusion at 20 C reduces preservation damage to livers from non-heart beating donors Cryobiology 62 2 2011 152 158
    • (2011) Cryobiology , vol.62 , Issue.2 , pp. 152-158
    • Ferrigno, A.1    Rizzo, V.2    Boncompagni, E.3
  • 15
    • 84860321534 scopus 로고    scopus 로고
    • Subnormothermic machine perfusion at both 20C and 30C recovers ischemic rat livers for successful transplantation
    • H. Tolboom, M.L. Izamis, and N. Sharma Subnormothermic machine perfusion at both 20C and 30C recovers ischemic rat livers for successful transplantation J Surg Res 175 1 2012 149 156
    • (2012) J Surg Res , vol.175 , Issue.1 , pp. 149-156
    • Tolboom, H.1    Izamis, M.L.2    Sharma, N.3
  • 16
    • 84880824965 scopus 로고    scopus 로고
    • A simplified subnormothermic machine perfusion model restores ischemically damaged liver grafts in a rat model of orthotopic liver transplantation
    • T. Berendsen, B. Bruinsma, and J.W. Lee A simplified subnormothermic machine perfusion model restores ischemically damaged liver grafts in a rat model of orthotopic liver transplantation Transplant Res 1 1 2012 6
    • (2012) Transplant Res , vol.1 , Issue.1 , pp. 6
    • Berendsen, T.1    Bruinsma, B.2    Lee, J.W.3
  • 17
    • 0036091453 scopus 로고    scopus 로고
    • Hepatotic steatosis and its relationship to transplantation
    • C.J. Imber, S.D. St Peter, and A. Handa Hepatotic steatosis and its relationship to transplantation Liver Transpl 8 5 2002 415 423
    • (2002) Liver Transpl , vol.8 , Issue.5 , pp. 415-423
    • Imber, C.J.1    St Peter, S.D.2    Handa, A.3
  • 18
    • 3442893625 scopus 로고    scopus 로고
    • Impairment of hepatic microcirculation in fatty liver
    • S. Ijaz, W. Yang, and M.C. Winslet Impairment of hepatic microcirculation in fatty liver Microcirculation 10 6 2003 447 456
    • (2003) Microcirculation , vol.10 , Issue.6 , pp. 447-456
    • Ijaz, S.1    Yang, W.2    Winslet, M.C.3
  • 19
    • 80053327103 scopus 로고    scopus 로고
    • The prognostic value of renal resistance during hypothermic machine perfusion of deceased donor kidneys
    • I. Jochmans, C. Moers, and J.M. Smits The prognostic value of renal resistance during hypothermic machine perfusion of deceased donor kidneys Am J Transplant 11 10 2011 2214 2220
    • (2011) Am J Transplant , vol.11 , Issue.10 , pp. 2214-2220
    • Jochmans, I.1    Moers, C.2    Smits, J.M.3
  • 20
    • 0027440496 scopus 로고
    • Isolated perfusion of rat livers: Effect of temperature on O2 consumption, enzyme release, energy store, and morphology
    • S. Fujita, I. Hamamoto, and K. Nakamura Isolated perfusion of rat livers: effect of temperature on O2 consumption, enzyme release, energy store, and morphology Nippon Geka Hokan 62 1993 58 70
    • (1993) Nippon Geka Hokan , vol.62 , pp. 58-70
    • Fujita, S.1    Hamamoto, I.2    Nakamura, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.