메뉴 건너뛰기




Volumn 41, Issue 6, 2013, Pages 1279-1296

Evaluation of shear-induced platelet activation models under constant and dynamic shear stress loading conditions relevant to devices

Author keywords

Blood damage models; Blood flow; Cardiovascular devices; Damage accumulation; Platelet activation; Platelet sensitization

Indexed keywords

BLOOD DAMAGE; BLOOD FLOW; CARDIOVASCULAR DEVICES; DAMAGE ACCUMULATION; PLATELET ACTIVATION;

EID: 84886731300     PISSN: 00906964     EISSN: 15739686     Source Type: Journal    
DOI: 10.1007/s10439-013-0758-x     Document Type: Article
Times cited : (103)

References (38)
  • 1
    • 34548183335 scopus 로고    scopus 로고
    • Flow-induced platelet activation and damage accumulation in a mechanical heart valve: Numerical studies
    • 17725695 10.1111/j.1525-1594.2007.00446.x
    • Alemu, Y., and D. Bluestein. Flow-induced platelet activation and damage accumulation in a mechanical heart valve: numerical studies. Artif. Organs. 31:677-688, 2007.
    • (2007) Artif. Organs. , vol.31 , pp. 677-688
    • Alemu, Y.1    Bluestein, D.2
  • 2
    • 77956393128 scopus 로고    scopus 로고
    • Design optimization of a mechanical heart valve for reducing valve thrombogenicity-A case study with ATS valve
    • 20613492 10.1097/MAT.0b013e3181e65bf9
    • Alemu, Y., G. Girdhar, M. Xenos, J. Sheriff, J. Jesty, S. Einav, and D. Bluestein. Design optimization of a mechanical heart valve for reducing valve thrombogenicity-a case study with ATS valve. ASAIO J. 56:389-396, 2010.
    • (2010) ASAIO J. , vol.56 , pp. 389-396
    • Alemu, Y.1    Girdhar, G.2    Xenos, M.3    Sheriff, J.4    Jesty, J.5    Einav, S.6    Bluestein, D.7
  • 4
    • 33646562178 scopus 로고    scopus 로고
    • Towards optimization of the thrombogenic potential of blood recirculating cardiovascular devices using modeling approaches
    • 16681446 10.1586/17434440.3.3.267
    • Bluestein, D. Towards optimization of the thrombogenic potential of blood recirculating cardiovascular devices using modeling approaches. Expert Rev. Med. Devices 3:267-270, 2006.
    • (2006) Expert Rev. Med. Devices , vol.3 , pp. 267-270
    • Bluestein, D.1
  • 5
    • 77952011205 scopus 로고    scopus 로고
    • Towards non-thrombogenic performance of blood recirculating devices
    • 20131098 10.1007/s10439-010-9905-9 1:STN:280:DC%2BC3c7ptVektg%3D%3D
    • Bluestein, D., K. B. Chandran, and K. B. Manning. Towards non-thrombogenic performance of blood recirculating devices. Ann. Biomed. Eng. 38:1236-1256, 2010.
    • (2010) Ann. Biomed. Eng. , vol.38 , pp. 1236-1256
    • Bluestein, D.1    Chandran, K.B.2    Manning, K.B.3
  • 6
    • 0031105449 scopus 로고    scopus 로고
    • Fluid mechanics of arterial stenosis: Relationship to the development of mural thrombus
    • 9084839 10.1007/BF02648048 1:STN:280:DyaK2s3jvFWmsw%3D%3D
    • Bluestein, D., L. Niu, R. T. Schoephoerster, and M. K. Dewanjee. Fluid mechanics of arterial stenosis: relationship to the development of mural thrombus. Ann. Biomed. Eng. 25:344-356, 1997.
    • (1997) Ann. Biomed. Eng. , vol.25 , pp. 344-356
    • Bluestein, D.1    Niu, L.2    Schoephoerster, R.T.3    Dewanjee, M.K.4
  • 7
    • 48949098859 scopus 로고    scopus 로고
    • 2008 focused update incorporated into the ACC/AHA 2006 guidelines for the management of patients with valvular heart disease
    • A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to revise the 1998 guidelines for the management of patients with valvular heart disease). Endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons
    • Bonow, R. O., B. A. Carabello, K. Chatterjee, A. C. de Leon, Jr., D. P. Faxon, M. D. Freed, W. H. Gaasch, B. W. Lytle, R. A. Nishimura, P. T. O'Gara, R. A. O'Rourke, C. M. Otto, P. M. Shah, and J. S. Shanewise. 2008 focused update incorporated into the ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to revise the 1998 guidelines for the management of patients with valvular heart disease). Endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons. J. Am. Coll. Cardiol. 52:e1-142, 2008.
    • (2008) J. Am. Coll. Cardiol. , vol.52
    • Bonow, R.O.1    Carabello, B.A.2    Chatterjee, K.3    De Leon, Jr.A.C.4    Faxon, D.P.5    Freed, M.D.6    Gaasch, W.H.7    Lytle, B.W.8    Nishimura, R.A.9    O'Gara, P.T.10    O'Rourke, R.A.11    Otto, C.M.12    Shah, P.M.13    Shanewise, J.S.14
  • 8
    • 0038498530 scopus 로고
    • Potential for platelet stimulation in critically stenosed carotid and coronary arteries
    • Boreda, R., R. S. Fatemi, and S. E. Rittgers. Potential for platelet stimulation in critically stenosed carotid and coronary arteries. J. Vasc. Invest. 1:26-37, 1995.
    • (1995) J. Vasc. Invest. , vol.1 , pp. 26-37
    • Boreda, R.1    Fatemi, R.S.2    Rittgers, S.E.3
  • 9
    • 0041916071 scopus 로고    scopus 로고
    • A new scoring system to determine thromboembolic risk after heart valve replacement
    • Butchart, E. G., A. Ionescu, N. Payne, J. Giddings, G. L. Grunkemeier, and A. G. Fraser. A new scoring system to determine thromboembolic risk after heart valve replacement. Circulation 108(Suppl 1):II68-II74, 2003.
    • (2003) Circulation , vol.108 , Issue.SUPPL. 1
    • Butchart, E.G.1    Ionescu, A.2    Payne, N.3    Giddings, J.4    Grunkemeier, G.L.5    Fraser, A.G.6
  • 10
    • 0024151165 scopus 로고
    • Anticoagulation variability between centres: Implications for comparative prosthetic valve assessment
    • 3272209 10.1016/S1010-7940(88)80002-2 1:STN:280:DyaK3c7ms1Omsg%3D%3D
    • Butchart, E. G., P. A. Lewis, E. N. Kulatilake, and I. M. Breckenridge. Anticoagulation variability between centres: implications for comparative prosthetic valve assessment. Eur. J. Cardiothorac. Surg. 2:72-81, 1988.
    • (1988) Eur. J. Cardiothorac. Surg. , vol.2 , pp. 72-81
    • Butchart, E.G.1    Lewis, P.A.2    Kulatilake, E.N.3    Breckenridge, I.M.4
  • 11
    • 55149124203 scopus 로고    scopus 로고
    • Past, present, and future of long-term mechanical cardiac support in adults
    • 10.1111/j.1540-8191.2007.00498.x
    • Christiansen, S., A. Klocke, and R. Autschbach. Past, present, and future of long-term mechanical cardiac support in adults. J. Cardiac Surg. 23:664-676, 2008.
    • (2008) J. Cardiac Surg. , vol.23 , pp. 664-676
    • Christiansen, S.1    Klocke, A.2    Autschbach, R.3
  • 12
    • 34548191456 scopus 로고    scopus 로고
    • Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model
    • 17655477 10.1115/1.2746378
    • Dumont, K., J. Vierendeels, R. Kaminsky, G. van Nooten, P. Verdonck, and D. Bluestein. Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model. J. Biomech. Eng. 129:558-565, 2007.
    • (2007) J. Biomech. Eng. , vol.129 , pp. 558-565
    • Dumont, K.1    Vierendeels, J.2    Kaminsky, R.3    Van Nooten, G.4    Verdonck, P.5    Bluestein, D.6
  • 13
    • 33750598352 scopus 로고    scopus 로고
    • Performance comparison of neural network training algorithms in modeling of bimodal drug delivery
    • 16959449 10.1016/j.ijpharm.2006.07.056 1:CAS:528:DC%2BD28XhtFKhsLfI
    • Ghaffari, A., H. Abdollahi, M. R. Khoshayand, I. S. Bozchalooi, A. Dadgar, and M. Rafiee-Tehrani. Performance comparison of neural network training algorithms in modeling of bimodal drug delivery. Int. J. Pharm. 327:126-138, 2006.
    • (2006) Int. J. Pharm. , vol.327 , pp. 126-138
    • Ghaffari, A.1    Abdollahi, H.2    Khoshayand, M.R.3    Bozchalooi, I.S.4    Dadgar, A.5    Rafiee-Tehrani, M.6
  • 14
    • 0025082325 scopus 로고
    • Estimation of shear stress-related blood damage in heart valve prostheses-in vitro comparison of 25 aortic valves
    • 2365485 1:STN:280:DyaK3czgslaqsg%3D%3D
    • Giersiepen, M., L. J. Wurzinger, R. Opitz, and H. Reul. Estimation of shear stress-related blood damage in heart valve prostheses-in vitro comparison of 25 aortic valves. Int. J. Artif. Organs. 13:300-306, 1990.
    • (1990) Int. J. Artif. Organs. , vol.13 , pp. 300-306
    • Giersiepen, M.1    Wurzinger, L.J.2    Opitz, R.3    Reul, H.4
  • 15
    • 2542439910 scopus 로고    scopus 로고
    • Numerical estimation of blood damage in artificial organs
    • 15113346 10.1111/j.1525-1594.2004.07265.x
    • Goubergrits, L., and K. Affeld. Numerical estimation of blood damage in artificial organs. Artif. Organs. 28:499-507, 2004.
    • (2004) Artif. Organs. , vol.28 , pp. 499-507
    • Goubergrits, L.1    Affeld, K.2
  • 16
    • 2542462454 scopus 로고    scopus 로고
    • The power-law mathematical model for blood damage prediction: Analytical developments and physical inconsistencies
    • 15113341 10.1111/j.1525-1594.2004.00015.x
    • Grigioni, M., C. Daniele, U. Morbiducci, G. D'Avenio, G. Di Benedetto, and V. Barbaro. The power-law mathematical model for blood damage prediction: analytical developments and physical inconsistencies. Artif. Organs. 28:467-475, 2004.
    • (2004) Artif. Organs. , vol.28 , pp. 467-475
    • Grigioni, M.1    Daniele, C.2    Morbiducci, U.3    D'Avenio, G.4    Di Benedetto, G.5    Barbaro, V.6
  • 17
    • 28344456033 scopus 로고    scopus 로고
    • A novel formulation for blood trauma prediction by a modified power-law mathematical model
    • 16283225 10.1007/s10237-005-0005-y
    • Grigioni, M., U. Morbiducci, G. D'Avenio, G. D. Benedetto, and C. D. Gaudio. A novel formulation for blood trauma prediction by a modified power-law mathematical model. Biomech. Model. Mechanobiol. 4:249-260, 2005.
    • (2005) Biomech. Model. Mechanobiol. , vol.4 , pp. 249-260
    • Grigioni, M.1    Morbiducci, U.2    D'Avenio, G.3    Benedetto, G.D.4    Gaudio, C.D.5
  • 18
    • 0001960147 scopus 로고
    • Studies on the mechanisms of shear-induced platelet activation
    • A. Hartmann W. Kuschinsky (eds) Springer Heidelberg 10.1007/978-3-642- 71787-1-8
    • Hellums, J. D., D. M. Peterson, N. A. Stathopoulos, and J. Moake. Studies on the mechanisms of shear-induced platelet activation. In: Cerebral Ischemia and Hemorheology, edited by A. Hartmann, and W. Kuschinsky. Heidelberg: Springer, 1987, pp. 80-89.
    • (1987) Cerebral Ischemia and Hemorheology , pp. 80-89
    • Hellums, J.D.1    Peterson, D.M.2    Stathopoulos, N.A.3    Moake, J.4
  • 19
    • 0033566160 scopus 로고    scopus 로고
    • Acetylated prothrombin as a substrate in the measurement of the procoagulant activity of platelets: Elimination of the feedback activation of platelets by thrombin
    • 10405294 10.1006/abio.1999.4148 1:CAS:528:DyaK1MXktlygtL0%3D
    • Jesty, J., and D. Bluestein. Acetylated prothrombin as a substrate in the measurement of the procoagulant activity of platelets: elimination of the feedback activation of platelets by thrombin. Anal. Biochem. 272:64-70, 1999.
    • (1999) Anal. Biochem. , vol.272 , pp. 64-70
    • Jesty, J.1    Bluestein, D.2
  • 21
    • 0000873069 scopus 로고
    • A method for the solution of certain non-linear problems in least squares
    • Levenberg, K. A method for the solution of certain non-linear problems in least squares. Q. Appl. Math. 2:164-168, 1944.
    • (1944) Q. Appl. Math. , vol.2 , pp. 164-168
    • Levenberg, K.1
  • 22
    • 0000169232 scopus 로고
    • An algorithm for least-squares estimation of nonlinear parameters
    • 10.1137/0111030
    • Marquardt, D. An algorithm for least-squares estimation of nonlinear parameters. SIAM J. Appl. Math. 11:431-441, 1963.
    • (1963) SIAM J. Appl. Math. , vol.11 , pp. 431-441
    • Marquardt, D.1
  • 23
    • 68149161782 scopus 로고    scopus 로고
    • Blood damage safety of prosthetic heart valves. Shear-induced platelet activation and local flow dynamics: A fluid-structure interaction approach
    • 19524927 10.1016/j.jbiomech.2009.05.014
    • Morbiducci, U., R. Ponzini, M. Nobili, D. Massai, F. M. Montevecchi, D. Bluestein, and A. Redaelli. Blood damage safety of prosthetic heart valves. Shear-induced platelet activation and local flow dynamics: a fluid-structure interaction approach. J. Biomech. 42:1952-1960, 2009.
    • (2009) J. Biomech. , vol.42 , pp. 1952-1960
    • Morbiducci, U.1    Ponzini, R.2    Nobili, M.3    Massai, D.4    Montevecchi, F.M.5    Bluestein, D.6    Redaelli, A.7
  • 24
    • 28044461957 scopus 로고    scopus 로고
    • Genetic algorithms for parameter estimation in mathematical modeling of glucose metabolism
    • 16310011 10.1016/j.compbiomed.2004.07.005 1:CAS:528:DC%2BD2MXht1Ght7jE
    • Morbiducci, U., A. Tura, and M. Grigioni. Genetic algorithms for parameter estimation in mathematical modeling of glucose metabolism. Comput. Biol. Med. 35:862-874, 2005.
    • (2005) Comput. Biol. Med. , vol.35 , pp. 862-874
    • Morbiducci, U.1    Tura, A.2    Grigioni, M.3
  • 25
    • 38349187878 scopus 로고    scopus 로고
    • Platelet activation due to hemodynamic shear stresses: Damage accumulation model and comparison to in vitro measurements
    • 18204318 10.1097/MAT.0b013e31815d6898
    • Nobili, M., J. Sheriff, U. Morbiducci, A. Redaelli, and D. Bluestein. Platelet activation due to hemodynamic shear stresses: damage accumulation model and comparison to in vitro measurements. ASAIO J. 54:64-72, 2008.
    • (2008) ASAIO J. , vol.54 , pp. 64-72
    • Nobili, M.1    Sheriff, J.2    Morbiducci, U.3    Redaelli, A.4    Bluestein, D.5
  • 26
    • 0025954833 scopus 로고
    • The effects of elongational stress exposure on the activation and aggregation of blood platelets
    • Purvis, N. B., Jr., and T. D. Giorgio. The effects of elongational stress exposure on the activation and aggregation of blood platelets. Biorheology 28:355-367, 1991.
    • (1991) Biorheology , vol.28 , pp. 355-367
    • Purvis Jr., N.B.1    Giorgio, T.D.2
  • 27
    • 0018378290 scopus 로고
    • Shear-induced activation of platelets
    • 422576 10.1016/0021-9290(79)90150-7 1:STN:280:DyaE1M7jtVCluw%3D%3D
    • Ramstack, J. M., L. Zuckerman, and L. F. Mockros. Shear-induced activation of platelets. J. Biomech. 12:113-125, 1979.
    • (1979) J. Biomech. , vol.12 , pp. 113-125
    • Ramstack, J.M.1    Zuckerman, L.2    Mockros, L.F.3
  • 28
    • 33745086957 scopus 로고    scopus 로고
    • The extent of platelet activation under shear depends on platelet count: Differential expression of anionic phospholipid and factor Va
    • 16772736 10.1159/000093104 1:CAS:528:DC%2BD28XlsFOmsLw%3D
    • Schulz-Heik, K., J. Ramachandran, D. Bluestein, and J. Jesty. The extent of platelet activation under shear depends on platelet count: differential expression of anionic phospholipid and factor Va. Pathophysiol. Haemost. Thromb. 34:255-262, 2005.
    • (2005) Pathophysiol. Haemost. Thromb. , vol.34 , pp. 255-262
    • Schulz-Heik, K.1    Ramachandran, J.2    Bluestein, D.3    Jesty, J.4
  • 29
    • 77952011415 scopus 로고    scopus 로고
    • High-shear stress sensitizes platelets to subsequent low-shear conditions
    • 20135353 10.1007/s10439-010-9936-2
    • Sheriff, J., D. Bluestein, G. Girdhar, and J. Jesty. High-shear stress sensitizes platelets to subsequent low-shear conditions. Ann. Biomed. Eng. 38:1442-1450, 2010.
    • (2010) Ann. Biomed. Eng. , vol.38 , pp. 1442-1450
    • Sheriff, J.1    Bluestein, D.2    Girdhar, G.3    Jesty, J.4
  • 30
    • 78149280982 scopus 로고    scopus 로고
    • Numerical investigation of the performance of three hinge designs of bileaflet mechanical heart valves
    • 20571852 10.1007/s10439-010-0086-3
    • Simon, H. A., L. Ge, F. Sotiropoulos, and A. P. Yoganathan. Numerical investigation of the performance of three hinge designs of bileaflet mechanical heart valves. Ann. Biomed. Eng. 38:3295-3310, 2010.
    • (2010) Ann. Biomed. Eng. , vol.38 , pp. 3295-3310
    • Simon, H.A.1    Ge, L.2    Sotiropoulos, F.3    Yoganathan, A.P.4
  • 31
    • 0016446510 scopus 로고
    • Deformation and fragmentation of human red blood cells in turbulent shear flow
    • 1174639 10.1016/S0006-3495(75)85787-0 1:STN:280:DyaE28%2FhvFeluw%3D%3D
    • Sutera, S. P., and M. H. Mehrjardi. Deformation and fragmentation of human red blood cells in turbulent shear flow. Biophys. J. 15:1-10, 1975.
    • (1975) Biophys. J. , vol.15 , pp. 1-10
    • Sutera, S.P.1    Mehrjardi, M.H.2
  • 32
    • 0242321184 scopus 로고    scopus 로고
    • Path-dependent hemodynamics of the stenosed carotid bifurcation
    • 14582608 10.1114/1.1603257
    • Tambasco, M., and D. A. Steinman. Path-dependent hemodynamics of the stenosed carotid bifurcation. Ann. Biomed. Eng. 31:1054-1065, 2003.
    • (2003) Ann. Biomed. Eng. , vol.31 , pp. 1054-1065
    • Tambasco, M.1    Steinman, D.A.2
  • 33
    • 79951553780 scopus 로고    scopus 로고
    • Numerical investigation of the effects of channel geometry on platelet activation and blood damage
    • 20976558 10.1007/s10439-010-0184-2
    • Wu, J., B. M. Yun, A. M. Fallon, S. R. Hanson, C. K. Aidun, and A. P. Yoganathan. Numerical investigation of the effects of channel geometry on platelet activation and blood damage. Ann. Biomed. Eng. 39:897-910, 2010.
    • (2010) Ann. Biomed. Eng. , vol.39 , pp. 897-910
    • Wu, J.1    Yun, B.M.2    Fallon, A.M.3    Hanson, S.R.4    Aidun, C.K.5    Yoganathan, A.P.6
  • 34
    • 0022214273 scopus 로고
    • Platelet and coagulation parameters following millisecond exposure to laminar shear stress
    • 2934855 1:STN:280:DyaL28%2FpslKhsA%3D%3D
    • Wurzinger, L. J., R. Opitz, P. Blasberg, and H. Schmid-Schonbein. Platelet and coagulation parameters following millisecond exposure to laminar shear stress. Thromb. Haemost. 54:381-386, 1985.
    • (1985) Thromb. Haemost. , vol.54 , pp. 381-386
    • Wurzinger, L.J.1    Opitz, R.2    Blasberg, P.3    Schmid-Schonbein, H.4
  • 35
    • 77955560669 scopus 로고    scopus 로고
    • Device Thrombogenicity Emulator (DTE)-design optimization methodology for cardiovascular devices: A study in two bileaflet MHV designs
    • 20483411 10.1016/j.jbiomech.2010.04.020
    • Xenos, M., G. Girdhar, Y. Alemu, J. Jesty, M. Slepian, S. Einav, and D. Bluestein. Device Thrombogenicity Emulator (DTE)-design optimization methodology for cardiovascular devices: a study in two bileaflet MHV designs. J. Biomech. 43:2400-2409, 2010.
    • (2010) J. Biomech. , vol.43 , pp. 2400-2409
    • Xenos, M.1    Girdhar, G.2    Alemu, Y.3    Jesty, J.4    Slepian, M.5    Einav, S.6    Bluestein, D.7
  • 36
    • 0029091501 scopus 로고
    • A mathematical model for shear-induced hemolysis
    • 8572955 10.1111/j.1525-1594.1995.tb02384.x 1:STN:280:DyaK287ntV2lsA%3D%3D
    • Yeleswarapu, K. K., J. F. Antaki, M. V. Kameneva, and K. R. Rajagopal. A mathematical model for shear-induced hemolysis. Artif. Organs. 19:576-582, 1995.
    • (1995) Artif. Organs. , vol.19 , pp. 576-582
    • Yeleswarapu, K.K.1    Antaki, J.F.2    Kameneva, M.V.3    Rajagopal, K.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.