메뉴 건너뛰기




Volumn 28, Issue 5, 2004, Pages 467-475

The power-law mathematical model for blood damage prediction: Analytical developments and physical inconsistencies

Author keywords

Blood trauma prediction; Hemolysis; Mathematical model; Red blood cell damage; Shear stress

Indexed keywords

ARTIFICIAL HEART; BLOOD VESSELS; CELLS; DAMAGE DETECTION; SHEAR FLOW; SHEAR STRESS;

EID: 2542462454     PISSN: 0160564X     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2004.00015.x     Document Type: Article
Times cited : (109)

References (35)
  • 2
    • 0021685904 scopus 로고
    • Human red blood cell hemolysis in a turbulent shear flow, contribution of Reynolds shear stresses
    • Sallam AM, Hwang NHC. Human red blood cell hemolysis in a turbulent shear flow, contribution of Reynolds shear stresses. Biorheology 1984;21:783-97.
    • (1984) Biorheology , vol.21 , pp. 783-797
    • Sallam, A.M.1    Hwang, N.H.C.2
  • 3
    • 0033213797 scopus 로고    scopus 로고
    • A discussion on the threshold limit for hemolysis related to Reynolds shear stress
    • Grigioni M, Daniele C, D'Avenio G, Barbaro V. A discussion on the threshold limit for hemolysis related to Reynolds shear stress. J Biomech 1999;32:1107-12.
    • (1999) J Biomech , vol.32 , pp. 1107-1112
    • Grigioni, M.1    Daniele, C.2    D'Avenio, G.3    Barbaro, V.4
  • 4
    • 0034879360 scopus 로고    scopus 로고
    • A re-evaluation and discussion on the threshold limit for hemolysis in a turbulent shear flow
    • Lu PC, Lai HC, Liu JS. A re-evaluation and discussion on the threshold limit for hemolysis in a turbulent shear flow. J Biomech 2001;34:1361-4.
    • (2001) J Biomech , vol.34 , pp. 1361-1364
    • Lu, P.C.1    Lai, H.C.2    Liu, J.S.3
  • 5
    • 0029331399 scopus 로고
    • Mechanically induced blood trauma: Are the relevant questions already solved, or is it still an important field to be investigated?
    • Schima H, Wieselthaler G. Mechanically induced blood trauma: are the relevant questions already solved, or is it still an important field to be investigated? Artif Organs 1995;19:563-4.
    • (1995) Artif Organs , vol.19 , pp. 563-564
    • Schima, H.1    Wieselthaler, G.2
  • 6
    • 0035985028 scopus 로고    scopus 로고
    • Numerical calculation of hemolysis levels in peripheral hemodialysis cannulas
    • De Wachter D, Verdonck P. Numerical calculation of hemolysis levels in peripheral hemodialysis cannulas. Artif Organs 2002;26:576-82.
    • (2002) Artif Organs , vol.26 , pp. 576-582
    • De Wachter, D.1    Verdonck, P.2
  • 7
    • 0016446510 scopus 로고
    • Deformation and fragmentation of human RBC in turbulent shear flow
    • Sutera SP, Mehriardj MH. Deformation and fragmentation of human RBC in turbulent shear flow. Biophys J 1975;15:1-10.
    • (1975) Biophys J , vol.15 , pp. 1-10
    • Sutera, S.P.1    Mehriardj, M.H.2
  • 8
    • 0000198669 scopus 로고    scopus 로고
    • Recent findings on flow induced blood damage: Critical shear stresses and exposure times obtained with a high shear Couette-system
    • Paul R, Schügner F, Reul H, Rau G. Recent findings on flow induced blood damage: critical shear stresses and exposure times obtained with a high shear Couette-system. Artif Organs 1999;23:680.
    • (1999) Artif Organs , vol.23 , pp. 680
    • Paul, R.1    Schügner, F.2    Reul, H.3    Rau, G.4
  • 9
    • 0014966213 scopus 로고
    • Hemolysis near an ultrasonically pulsating gas bubble
    • Rooney JA. Hemolysis near an ultrasonically pulsating gas bubble. Science 1970;169:869-71.
    • (1970) Science , vol.169 , pp. 869-871
    • Rooney, J.A.1
  • 11
    • 2542474374 scopus 로고
    • Thesis. University of Minnesota Minneapolis
    • Keshavian JMS. Thesis. University of Minnesota Minneapolis, 1970.
    • (1970)
    • Keshavian, J.M.S.1
  • 12
    • 2242427354 scopus 로고
    • Hemolysis at prosthetic surfaces
    • Hair MR, ed. New York: Marcel Dekker
    • Blackshear PL. Hemolysis at prosthetic surfaces. In: Hair MR, ed. Chemistry of Biosurfaces, New York: Marcel Dekker, 1972;523-62.
    • (1972) Chemistry of Biosurfaces , pp. 523-562
    • Blackshear, P.L.1
  • 13
    • 0003309626 scopus 로고
    • Mechanical hemolysis in flowing blood
    • Fung YC, ed. Englewood Cliffs, NJ: Prentice Hall Inc
    • Blackshear PL. Mechanical hemolysis in flowing blood. In: Fung YC, ed. Biomechanics. Its Foundation and Objectives. Englewood Cliffs, NJ: Prentice Hall Inc, 1972;501.
    • (1972) Biomechanics. Its Foundation and Objectives , pp. 501
    • Blackshear, P.L.1
  • 15
    • 0001416195 scopus 로고
    • Hemolysis near a transversely oscillating wire
    • Williams AR, Hughes DE, Nyborg WL. Hemolysis near a transversely oscillating wire. Science 1970;169:871-3.
    • (1970) Science , vol.169 , pp. 871-873
    • Williams, A.R.1    Hughes, D.E.2    Nyborg, W.L.3
  • 18
    • 2542480982 scopus 로고
    • Thesis. University of Minnesota Minneapolis
    • Steinbach JMS. Thesis. University of Minnesota Minneapolis, 1970.
    • (1970)
    • Steinbach, J.M.S.1
  • 20
    • 0034791973 scopus 로고    scopus 로고
    • Pulsatile flow studies of a porcine bioprosthetic aortic valve in vitro: PIV measurements and shear-induced blood damage
    • Lim WL, Chew YT, Chew TC, Low HT. Pulsatile flow studies of a porcine bioprosthetic aortic valve in vitro: PIV measurements and shear-induced blood damage. J Biomech 2001;34:1417-27.
    • (2001) J Biomech , vol.34 , pp. 1417-1427
    • Lim, W.L.1    Chew, Y.T.2    Chew, T.C.3    Low, H.T.4
  • 22
    • 0025082325 scopus 로고
    • Estimation of shear stress related blood damage in heart valve prostheses. In vitro comparison of 25 aortic valves
    • Giersiepen M, Wurzinger LJ, Opitz R, Reul H. Estimation of shear stress related blood damage in heart valve prostheses. in vitro comparison of 25 aortic valves. Int J Artif Organs 1990;13:300-6.
    • (1990) Int J Artif Organs , vol.13 , pp. 300-306
    • Giersiepen, M.1    Wurzinger, L.J.2    Opitz, R.3    Reul, H.4
  • 23
    • 0013307473 scopus 로고
    • Wall shear measurements at rigid and flexible boundaries as criterion for the design of cardiovascular prostheses
    • Berlin: Westkreuz-Druckerei
    • Tillmann W, Waschmann M. Wall shear measurements at rigid and flexible boundaries as criterion for the design of cardiovascular prostheses. Proceedings of the European Society for Artificial Organs. Berlin: Westkreuz-Druckerei, 1978.
    • (1978) Proceedings of the European Society for Artificial Organs
    • Tillmann, W.1    Waschmann, M.2
  • 25
    • 0036046291 scopus 로고    scopus 로고
    • Numerical investigation of the effect of blade geometry on blood trauma in a centrifugal blood pump
    • Chan WK, Wong YW, Ding Y, Chua LP, Yu SC. Numerical investigation of the effect of blade geometry on blood trauma in a centrifugal blood pump. Artif Organs 2002;26:785-93.
    • (2002) Artif Organs , vol.26 , pp. 785-793
    • Chan, W.K.1    Wong, Y.W.2    Ding, Y.3    Chua, L.P.4    Yu, S.C.5
  • 26
    • 0029090222 scopus 로고
    • Model for a general mechanical blood damage prediction
    • Bludszuweit C. Model for a general mechanical blood damage prediction. Artif Organs 1995;19:583-9.
    • (1995) Artif Organs , vol.19 , pp. 583-589
    • Bludszuweit, C.1
  • 27
    • 0036262522 scopus 로고    scopus 로고
    • In vitro evaluation of hemolysis and sublethal blood trauma in a novel subcutaneous vascular access system for hemodialysis
    • Kameneva MV, Marad PF, Brugger JM, Repko BM, Wang JH, Moran J, Borovetz HS. In vitro evaluation of hemolysis and sublethal blood trauma in a novel subcutaneous vascular access system for hemodialysis. ASAIO J 2002;48:34-8.
    • (2002) ASAIO J , vol.48 , pp. 34-38
    • Kameneva, M.V.1    Marad, P.F.2    Brugger, J.M.3    Repko, B.M.4    Wang, J.H.5    Moran, J.6    Borovetz, H.S.7
  • 28
    • 0034000468 scopus 로고    scopus 로고
    • Velocities, shear stresses and blood damage potential of the leakage jets of the Medtronic Parallel bileaflet valve
    • Zimmer R, Steegers A, Paul R, Affeld K, Reul H. Velocities, shear stresses and blood damage potential of the leakage jets of the Medtronic Parallel bileaflet valve. Int J Artif Organs 2000;23:41-8.
    • (2000) Int J Artif Organs , vol.23 , pp. 41-48
    • Zimmer, R.1    Steegers, A.2    Paul, R.3    Affeld, K.4    Reul, H.5
  • 30
    • 0034838318 scopus 로고    scopus 로고
    • Computational fluid dynamics as a development tool for rotary blood pumps
    • Burgreen GW, Antaki JF, Wu ZJ, Holmes AJ. Computational fluid dynamics as a development tool for rotary blood pumps. Artif Organs 2001;25:336-40.
    • (2001) Artif Organs , vol.25 , pp. 336-340
    • Burgreen, G.W.1    Antaki, J.F.2    Wu, Z.J.3    Holmes, A.J.4
  • 31
    • 0034837086 scopus 로고    scopus 로고
    • Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics
    • Apel J, Paul R, Klaus S, Siess T, Reul H. Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics. Artif Organs 2001;25:341-7.
    • (2001) Artif Organs , vol.25 , pp. 341-347
    • Apel, J.1    Paul, R.2    Klaus, S.3    Siess, T.4    Reul, H.5
  • 34
    • 0016741588 scopus 로고
    • Applications of a theoretical model for haemolysis in shear flow
    • Richardson E. Applications of a theoretical model for haemolysis in shear flow. Biorheology 1975;12:27-37.
    • (1975) Biorheology , vol.12 , pp. 27-37
    • Richardson, E.1
  • 35
    • 0027230918 scopus 로고
    • Mechanical blood traumatization by tubing and throttles in in vitro pump tests, experimental results and implications for hemolysis theory
    • Schima H, Muller MR, Tsangaris S, et al. Mechanical blood traumatization by tubing and throttles in in vitro pump tests, experimental results and implications for hemolysis theory. Artif Organs 1993;17:164-70.
    • (1993) Artif Organs , vol.17 , pp. 164-170
    • Schima, H.1    Muller, M.R.2    Tsangaris, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.