-
1
-
-
0015233325
-
Experimental study of aluminium in surgery of hip
-
Boutin P,. Experimental study of aluminium in surgery of hip. Presse Med 1971; 79: 639.
-
(1971)
Presse Med
, vol.79
, pp. 639
-
-
Boutin, P.1
-
2
-
-
0033256670
-
The Otto Aufranc Award. Wear and lubrication of metal-on-metal hip implants
-
Chan FW, Bobyn JD, Medley JB, Krygier JJ, Tanzer M,. The Otto Aufranc Award. Wear and lubrication of metal-on-metal hip implants. Clin Orthop Relat Res 1999: 10-24.
-
(1999)
Clin Orthop Relat Res
, pp. 10-24
-
-
Chan, F.W.1
Bobyn, J.D.2
Medley, J.B.3
Krygier, J.J.4
Tanzer, M.5
-
3
-
-
0033641059
-
Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements
-
Clarke I, Good V, Williams P, Schroeder D, Anissian L, Stark A, Oonishi H, Schuldies J, Gustafson G,. Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements. Proc Inst Mech Eng [H] 2000; 214: 331-347.
-
(2000)
Proc Inst Mech Eng [H]
, vol.214
, pp. 331-347
-
-
Clarke, I.1
Good, V.2
Williams, P.3
Schroeder, D.4
Anissian, L.5
Stark, A.6
Oonishi, H.7
Schuldies, J.8
Gustafson, G.9
-
4
-
-
0036116447
-
Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses
-
Endo M, Tipper JL, Barton DC, Stone MH, Ingham E, Fisher J,. Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses. Proc Inst Mech Eng [H] 2002; 216: 111-122.
-
(2002)
Proc Inst Mech Eng [H]
, vol.216
, pp. 111-122
-
-
Endo, M.1
Tipper, J.L.2
Barton, D.C.3
Stone, M.H.4
Ingham, E.5
Fisher, J.6
-
5
-
-
34247623494
-
-
Volume. Wiley Subscription Services, Inc., A Wiley Company;
-
Brockett C, Williams S, Jin Z, Isaac G, Fisher J,. Friction of Total Hip Replacements With Different Bearings and Loading Conditions, Volume 81B. Wiley Subscription Services, Inc., A Wiley Company; 2007. pp 508-515.
-
(2007)
Friction of Total Hip Replacements with Different Bearings and Loading Conditions
, vol.81 B
, pp. 508-515
-
-
Brockett, C.1
Williams, S.2
Jin, Z.3
Isaac, G.4
Fisher, J.5
-
6
-
-
0029902177
-
Ceramic femoral head fractures in total hip arthroplasty
-
Fritsch EW, Gleitz M,. Ceramic femoral head fractures in total hip arthroplasty. Clin Orthop Relat Res 1996; 328: 129-136.
-
(1996)
Clin Orthop Relat Res
, vol.328
, pp. 129-136
-
-
Fritsch, E.W.1
Gleitz, M.2
-
7
-
-
0041419860
-
Ceramic acetabular liner fracture in THA with a ceramic sandwich cup
-
Hasegawa M, Sudo A, Hirata H, Uchida A,. Ceramic acetabular liner fracture in THA with a ceramic sandwich cup. Arthroplasty 2003; 18: 658-661.
-
(2003)
Arthroplasty
, vol.18
, pp. 658-661
-
-
Hasegawa, M.1
Sudo, A.2
Hirata, H.3
Uchida, A.4
-
8
-
-
0017462028
-
Reactions of the articular capsule to wear products of artificial joint prostheses
-
Willert HG,. Reactions of the articular capsule to wear products of artificial joint prostheses. J Biomed Mater Res 1977; 11: 157-164.
-
(1977)
J Biomed Mater Res
, vol.11
, pp. 157-164
-
-
Willert, H.G.1
-
9
-
-
11844293972
-
Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study
-
Willert HG, Buchhorn GH, Fayyazi A, Flury R, Windler M, Koster G, Lohmann CH,. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am 2005; 87: 28-36.
-
(2005)
J Bone Joint Surg Am
, vol.87
, pp. 28-36
-
-
Willert, H.G.1
Buchhorn, G.H.2
Fayyazi, A.3
Flury, R.4
Windler, M.5
Koster, G.6
Lohmann, C.H.7
-
10
-
-
47549111326
-
Pseudotumours associated with metal-onmetal hip resurfacings
-
Pandit H, Glyn-Jones S, McLardy-Smith P, Gundle R, Whitwell D, Gibbons CLM, Ostlere S, Athanasou N, Gill HS, Murray DW,. Pseudotumours associated with metal-onmetal hip resurfacings. J Bone Joint Surg Br 2008; 90B: 847-851.
-
(2008)
J Bone Joint Surg Br
, vol.90 B
, pp. 847-851
-
-
Pandit, H.1
Glyn-Jones, S.2
McLardy-Smith, P.3
Gundle, R.4
Whitwell, D.5
Gibbons, C.L.M.6
Ostlere, S.7
Athanasou, N.8
Gill, H.S.9
Murray, D.W.10
-
11
-
-
0000242627
-
Ex vivo and in vitro analysis of the alumina/alumina bearing system for hip joint prostheses
-
Refior HJ, Plitz W, Walter A,. Ex vivo and in vitro analysis of the alumina/alumina bearing system for hip joint prostheses. Bioceramics 1997; 10: 127-130.
-
(1997)
Bioceramics
, vol.10
, pp. 127-130
-
-
Refior, H.J.1
Plitz, W.2
Walter, A.3
-
12
-
-
0032881955
-
Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses
-
Nevelos JE, Ingham E, Doyle C, Fisher J, Nevelos AB,. Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses. Biomaterials 1999; 20: 1833-1840.
-
(1999)
Biomaterials
, vol.20
, pp. 1833-1840
-
-
Nevelos, J.E.1
Ingham, E.2
Doyle, C.3
Fisher, J.4
Nevelos, A.B.5
-
13
-
-
0033814067
-
Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns
-
Nevelos J, Ingham E, Doyle C, Streicher R, Nevelos A, Walter W, Fisher J,. Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns. J Arthroplasty 2000; 15: 793-795.
-
(2000)
J Arthroplasty
, vol.15
, pp. 793-795
-
-
Nevelos, J.1
Ingham, E.2
Doyle, C.3
Streicher, R.4
Nevelos, A.5
Walter, W.6
Fisher, J.7
-
14
-
-
0034981637
-
Comparative analysis of two different types of alumina-alumina hip prosthesis retrieved for aseptic loosening
-
Nevelos JE, Prudhommeaux F, Hamadouche M, Doyle C, Ingham E, Meunier A, Nevelos AB, Sedel L, Fisher J,. Comparative analysis of two different types of alumina-alumina hip prosthesis retrieved for aseptic loosening. J Bone Joint Surg Br 2001; 83: 598-603.
-
(2001)
J Bone Joint Surg Br
, vol.83
, pp. 598-603
-
-
Nevelos, J.E.1
Prudhommeaux, F.2
Hamadouche, M.3
Doyle, C.4
Ingham, E.5
Meunier, A.6
Nevelos, A.B.7
Sedel, L.8
Fisher, J.9
-
15
-
-
0035482516
-
Characterisation of wear debris from UHMWPE on zirconia ceramic, metal-on-metal and alumina ceramic-on-ceramic hip prostheses generated in a physiological anatomical hip joint simulator
-
Tipper JL, Firkins PJ, Besong AA, Barbour PSM, Nevelos J, Stone MH, Ingham E, Fisher J,. Characterisation of wear debris from UHMWPE on zirconia ceramic, metal-on-metal and alumina ceramic-on-ceramic hip prostheses generated in a physiological anatomical hip joint simulator. Wear 2001; 250: 120-128.
-
(2001)
Wear
, vol.250
, pp. 120-128
-
-
Tipper, J.L.1
Firkins, P.J.2
Besong, A.A.3
Barbour, P.S.M.4
Nevelos, J.5
Stone, M.H.6
Ingham, E.7
Fisher, J.8
-
16
-
-
0035989711
-
Alumina-alumina artificial hip joints. Part I: A histological analysis and characterisation of wear debris by laser capture microdissection of tissues retrieved at revision
-
Hatton A, Nevelos JE, Nevelos AA, Banks RE, Fisher J, Ingham E,. Alumina-alumina artificial hip joints. Part I: A histological analysis and characterisation of wear debris by laser capture microdissection of tissues retrieved at revision. Biomaterials 2002; 23: 3429-3440.
-
(2002)
Biomaterials
, vol.23
, pp. 3429-3440
-
-
Hatton, A.1
Nevelos, J.E.2
Nevelos, A.A.3
Banks, R.E.4
Fisher, J.5
Ingham, E.6
-
17
-
-
0035989715
-
Alumina-alumina artificial hip joints. Part II: Characterisation of the wear debris from in vitro hip joint simulations
-
Tipper JL, Hatton A, Nevelos JE, Ingham E, Doyle C, Streicher R, Nevelos AB, Fisher J,. Alumina-alumina artificial hip joints. Part II: Characterisation of the wear debris from in vitro hip joint simulations. Biomaterials 2002; 23: 3441-3448.
-
(2002)
Biomaterials
, vol.23
, pp. 3441-3448
-
-
Tipper, J.L.1
Hatton, A.2
Nevelos, J.E.3
Ingham, E.4
Doyle, C.5
Streicher, R.6
Nevelos, A.B.7
Fisher, J.8
-
18
-
-
0346035850
-
Effects of clinically relevant alumina ceramic wear particles on TNF-alpha production by human peripheral blood mononuclear phagocytes
-
Hatton A, Nevelos JE, Matthews JB, Fisher J, Ingham E,. Effects of clinically relevant alumina ceramic wear particles on TNF-alpha production by human peripheral blood mononuclear phagocytes. Biomaterials 2003; 24: 1193-1204.
-
(2003)
Biomaterials
, vol.24
, pp. 1193-1204
-
-
Hatton, A.1
Nevelos, J.E.2
Matthews, J.B.3
Fisher, J.4
Ingham, E.5
-
19
-
-
84856773147
-
Nine years follow-up of 100 ceramic-on-ceramic total hip arthroplasty
-
Chevillotte C, Pibarot V, Carret J-P, Bejui-Hugues J, Guyen O,. Nine years follow-up of 100 ceramic-on-ceramic total hip arthroplasty. Int Orthop 2010: 1-6.
-
(2010)
Int Orthop
, pp. 1-6
-
-
Chevillotte, C.1
Pibarot, V.2
Carret, J.-P.3
Bejui-Hugues, J.4
Guyen, O.5
-
20
-
-
36849075129
-
Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty
-
Lusty PJ, Tai CC, Sew-Hoy RP, Walter WL, Walter WK, Zicat BA,. Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty. J Bone Joint Surg Am 2007; 89A: 2676-2683.
-
(2007)
J Bone Joint Surg Am
, vol.89 A
, pp. 2676-2683
-
-
Lusty, P.J.1
Tai, C.C.2
Sew-Hoy, R.P.3
Walter, W.L.4
Walter, W.K.5
Zicat, B.A.6
-
21
-
-
78549292127
-
Cementless total hip arthroplasty with ceramic-on-ceramic bearing in patients younger than 45 years with femoral-head osteonecrosis
-
Kim Y-H, Choi Y, Kim J-S,. Cementless total hip arthroplasty with ceramic-on-ceramic bearing in patients younger than 45 years with femoral-head osteonecrosis. Int Orthop 2010; 34: 1123-1127.
-
(2010)
Int Orthop
, vol.34
, pp. 1123-1127
-
-
Kim, Y.-H.1
Choi, Y.2
Kim, J.-S.3
-
22
-
-
0035114433
-
The influence of acetabular cup angle on the wear of "bIOLOX Forte" alumina ceramic bearing couples in a hip joint simulator
-
Nevelos JE, Ingham E, Doyle C, Nevelos AB, Fisher J,. The influence of acetabular cup angle on the wear of "BIOLOX Forte" alumina ceramic bearing couples in a hip joint simulator. J Mater Sci Mater Med 2001; 12: 141-144.
-
(2001)
J Mater Sci Mater Med
, vol.12
, pp. 141-144
-
-
Nevelos, J.E.1
Ingham, E.2
Doyle, C.3
Nevelos, A.B.4
Fisher, J.5
-
24
-
-
0035680629
-
Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions
-
Stewart T, Tipper J, Streicher R, Ingham E, Fisher J,. Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions. J Mater Sci Mater Med 2001; 12: 1053-1056.
-
(2001)
J Mater Sci Mater Med
, vol.12
, pp. 1053-1056
-
-
Stewart, T.1
Tipper, J.2
Streicher, R.3
Ingham, E.4
Fisher, J.5
-
25
-
-
69249208803
-
High cup angle and microseparation increase the wear of hip surface replacements
-
Leslie IJ, Williams S, Isaac G, Ingham E, Fisher J,. High cup angle and microseparation increase the wear of hip surface replacements. Clin Orthop Relat Res 2009; 467: 2259-2265.
-
(2009)
Clin Orthop Relat Res
, vol.467
, pp. 2259-2265
-
-
Leslie, I.J.1
Williams, S.2
Isaac, G.3
Ingham, E.4
Fisher, J.5
-
26
-
-
0035882726
-
Wear of HIPed and non-HIPed alumina-alumina hip joints under standard and severe simulator testing conditions
-
Nevelos JE, Ingham E, Doyle C, Nevelos AB, Fisher J,. Wear of HIPed and non-HIPed alumina-alumina hip joints under standard and severe simulator testing conditions. Biomaterials 2001; 22: 2191-2197.
-
(2001)
Biomaterials
, vol.22
, pp. 2191-2197
-
-
Nevelos, J.E.1
Ingham, E.2
Doyle, C.3
Nevelos, A.B.4
Fisher, J.5
-
27
-
-
0030627862
-
Frictional heating of bearing materials tested in a hip joint wear simulator
-
Lu Z, McKellop H,. Frictional heating of bearing materials tested in a hip joint wear simulator. Proc Inst Mech Eng [H] 1997; 211: 101-108.
-
(1997)
Proc Inst Mech Eng [H]
, vol.211
, pp. 101-108
-
-
Lu, Z.1
McKellop, H.2
-
28
-
-
0032886208
-
Poor eight-year survival of cemented zirconia-polyethylene total hip replacements
-
Allain J, Le Mouel S, Goutallier D, Voisin MC,. Poor eight-year survival of cemented zirconia-polyethylene total hip replacements. J Bone Joint Surg Br 1999; 81-B: 835-842.
-
(1999)
J Bone Joint Surg Br
, vol.81
, pp. 835-842
-
-
Allain, J.1
Le Mouel, S.2
Goutallier, D.3
Voisin, M.C.4
-
29
-
-
0141535277
-
Severe wear and fracture of zirconia heads against alumina inserts in hip simulator studies with microseparation
-
Stewart TD, Tipper JL, Insley G, Streicher RM, Ingham E, Fisher J,. Severe wear and fracture of zirconia heads against alumina inserts in hip simulator studies with microseparation. J Arthroplasty 2003; 18: 726-734.
-
(2003)
J Arthroplasty
, vol.18
, pp. 726-734
-
-
Stewart, T.D.1
Tipper, J.L.2
Insley, G.3
Streicher, R.M.4
Ingham, E.5
Fisher, J.6
-
30
-
-
34249112497
-
Investigations of the mechanical properties of an alumina toughened zirconia ceramic for an application in joint prostheses
-
Begand S, Oberbach T, Glien W,. Investigations of the mechanical properties of an alumina toughened zirconia ceramic for an application in joint prostheses. Bioceramics 2005; 284-286: 1019-1022.
-
(2005)
Bioceramics
, vol.284-286
, pp. 1019-1022
-
-
Begand, S.1
Oberbach, T.2
Glien, W.3
-
31
-
-
33645359192
-
Tribological behaviour of an alumina toughened zirconia ceramic for an application in joint prostheses
-
(Pts 1 and 2)
-
Begand S, Oberbach T, Glien W,. Tribological behaviour of an alumina toughened zirconia ceramic for an application in joint prostheses. Bioceramics 2006; 309-311 (Pts 1 and 2): 1261-1264.
-
(2006)
Bioceramics
, vol.309-311
, pp. 1261-1264
-
-
Begand, S.1
Oberbach, T.2
Glien, W.3
-
32
-
-
33846329438
-
Characteristic properties of a new dispersion ceramic
-
Begand S, Oberbach T, Glien W,. Characteristic properties of a new dispersion ceramic. Bioceramics 2007; 330-332: 1207-1210.
-
(2007)
Bioceramics
, vol.330-332
, pp. 1207-1210
-
-
Begand, S.1
Oberbach, T.2
Glien, W.3
-
33
-
-
33846275810
-
Luxation test of different ceramic on ceramic couplings
-
Oberbach T, Begand S, Glien W, Kaddick C,. Luxation test of different ceramic on ceramic couplings. Bioceramics 2007; 330-332: 1235-1238.
-
(2007)
Bioceramics
, vol.330-332
, pp. 1235-1238
-
-
Oberbach, T.1
Begand, S.2
Glien, W.3
Kaddick, C.4
-
34
-
-
0345168992
-
Long-term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparation
-
Stewart TD, Tipper JL, Insley G, Streicher RM, Ingham E, Fisher J,. Long-term wear of ceramic matrix composite materials for hip prostheses under severe swing phase microseparation. J Biomed Mater Res part B 2003; 66: 567-573.
-
(2003)
J Biomed Mater Res Part B
, vol.66
, pp. 567-573
-
-
Stewart, T.D.1
Tipper, J.L.2
Insley, G.3
Streicher, R.M.4
Ingham, E.5
Fisher, J.6
-
35
-
-
2442507670
-
Stripe wear rates in alumina THR - Comparison of microseparation simulator study with retrieved implants
-
Manaka M, Clarke IC, Yamamoto K, Shishido T, Gustafson A, Imakiire A,. Stripe wear rates in alumina THR-Comparison of microseparation simulator study with retrieved implants. J Biomed Mater Res B Appl Biomater 2004; 69B: 149-157.
-
(2004)
J Biomed Mater Res B Appl Biomater
, vol.69 B
, pp. 149-157
-
-
Manaka, M.1
Clarke, I.C.2
Yamamoto, K.3
Shishido, T.4
Gustafson, A.5
Imakiire, A.6
-
36
-
-
84886585202
-
Effect of Head Size on Wear in Metal-on-Metal Bearings in THRs under Steep Cup Inclination Angle and Adverse Edge Loading and Microseparation Conditions
-
Al-Hajjar M, Williams S, Fisher J, Jennings LM,. Effect of Head Size on Wear in Metal-on-Metal Bearings in THRs under Steep Cup Inclination Angle and Adverse Edge Loading and Microseparation Conditions. Long Beach, California, USA; 2011.
-
Long Beach, California, USA; 2011
-
-
Al-Hajjar, M.1
Williams, S.2
Fisher, J.3
Jennings, L.M.4
-
37
-
-
55849087920
-
Clicking and squeaking: In vivo correlation of sound and separation for different bearing surfaces
-
Glaser D, Komistek RD, Cates HE, Mahfouz MR,. Clicking and squeaking: in vivo correlation of sound and separation for different bearing surfaces. J Bone Joint Surg Am 2008; 90 (Suppl 4): 112-120.
-
(2008)
J Bone Joint Surg Am
, vol.90
, Issue.SUPPL. 4
, pp. 112-120
-
-
Glaser, D.1
Komistek, R.D.2
Cates, H.E.3
Mahfouz, M.R.4
-
38
-
-
79960628879
-
Bioengineering reasons for the failure of metal-on-metal hip prostheses: An engineer's perspective
-
Fisher J,. Bioengineering reasons for the failure of metal-on-metal hip prostheses: an engineer's perspective. J Bone Joint Surg Br 2011; 93: 1001.
-
(2011)
J Bone Joint Surg Br
, vol.93
, pp. 1001
-
-
Fisher, J.1
-
39
-
-
0036054006
-
Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements
-
Mak MM, Besong AA, Jin ZM, Fisher J,. Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements. Proc Inst Mech Eng [H] 2002; 216: 403-408.
-
(2002)
Proc Inst Mech Eng [H]
, vol.216
, pp. 403-408
-
-
Mak, M.M.1
Besong, A.A.2
Jin, Z.M.3
Fisher, J.4
-
40
-
-
0347596747
-
Assessment of wear in extensively irradiated UHMWPE cups in simulator studies
-
Oonishi H, Clarke IC, Yamamoto K, Masaoka T, Fujisawa A, Masuda S,. Assessment of wear in extensively irradiated UHMWPE cups in simulator studies. J Biomed Mater Res A 2004; 68A: 52-60.
-
(2004)
J Biomed Mater Res A
, vol.68 A
, pp. 52-60
-
-
Oonishi, H.1
Clarke, I.C.2
Yamamoto, K.3
Masaoka, T.4
Fujisawa, A.5
Masuda, S.6
-
41
-
-
33947375583
-
Wear and biological activity of highly crosslinked polyethylene in the hip under low serum protein concentrations
-
Galvin AL, Tipper IL, Jennings LM, Stone MH, Jin ZM, Ingham E, Fisher J,. Wear and biological activity of highly crosslinked polyethylene in the hip under low serum protein concentrations. Proc Inst Mech Eng [H] 2007; 221(H1): 1-10.
-
(2007)
Proc Inst Mech Eng [H]
, vol.2211
, pp. 1-10
-
-
Galvin, A.L.1
Tipper, I.L.2
Jennings, L.M.3
Stone, M.H.4
Jin, Z.M.5
Ingham, E.6
Fisher, J.7
|