Volumn 200, Issue , 2013, Pages 2-10

Magnetostrictive resonators as sensors and actuators

Author keywords

Actuator; Biosensor; Magnetostriction; Microcantilever; Resonator

Indexed keywords

ACTUATORS; ANTIBODIES; BIOSENSORS; CHEMICAL DETECTION; COMPOSITE MICROMECHANICS; ESCHERICHIA COLI; MAGNETOSTRICTION; MAGNETOSTRICTIVE DEVICES; NATURAL FREQUENCIES; RESONATORS;

EID: 84885378370     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2012.12.013     Document Type: Article
Times cited : (78)

References (50)
  • 4
    • 0020734314 scopus 로고
    • Thermal expansion coefficient and young's modulus of hydrogenated fcc fe-ni invar alloys
    • S. Harada, Thermal-expansion coefficient and youngs modulus of hydrogenated fcc Fe-Ni invar-alloys, Journal of the Physical Society of Japan 52 (1983) 1306-1310. (Pubitemid 13575596)
    • (1983) Journal of the Physical Society of Japan , vol.52 , Issue.4 , pp. 1306-1310
    • Harada Shuzi1
  • 8
    • 0031211589 scopus 로고    scopus 로고
    • Actuators, transducers and motors based on giant magnetostrictive materials
    • PII S0925838897000704
    • F. Claeyssen, N. Lhermet, R. LeLetty, P. Bouchilloux, Actuators, transducers and motors based on giant magnetostrictive materials, Journal of Alloys and Compounds 258 (1997) 61-73. (Pubitemid 127377428)
    • (1997) Journal of Alloys and Compounds , vol.258 , Issue.1-2 , pp. 61-73
    • Claeyssen, F.1    Lhermet, N.2    Le Letty, R.L.3    Bouchilloux, P.4
  • 12
    • 23444451895 scopus 로고    scopus 로고
    • Sensing of liquid level at micron resolution using self-excited millimeter-sized PZT-cantilever
    • DOI 10.1016/j.sna.2005.05.012, PII S0924424705003444
    • G. A. Campbell, R. Mutharasan, Sensing of liquid level at micron resolution using self-excited millimeter-sized PZT-cantilever, Sensors and Actuators A: Physical 122 (2) (2005) 326-334. (Pubitemid 41107380)
    • (2005) Sensors and Actuators, A: Physical , vol.122 , Issue.2 , pp. 326-334
    • Campbell, G.A.1    Mutharasan, R.2
  • 14
    • 0035888391 scopus 로고    scopus 로고
    • Micromechanical cantilever-based biosensors
    • DOI 10.1016/S0925-4005(01)00856-5, PII S0925400501008565
    • R. Raiteri, M. Grattarola, H. J. Butt, P. Skladal, Micromechanical cantilever-based biosensors, Sensors and Actuators B: Chemical 79 (2-3) (2001) 115-126. (Pubitemid 32866876)
    • (2001) Sensors and Actuators, B: Chemical , vol.79 , Issue.2-3 , pp. 115-126
    • Raiteri, R.1    Grattarola, M.2    Butt, H.-J.3    Skladal, P.4
  • 15
    • 33646170643 scopus 로고    scopus 로고
    • Applications of smart materials in the development of high performance biosensors
    • Z.-Y. Cheng, Applications of smart materials in the development of high performance biosensors, Materials Research Society Symposia Proceedings 888(2006), 185-195.
    • (2006) Materials Research Society Symposia Proceedings , vol.888 , pp. 185-195
    • Cheng, Z.-Y.1
  • 16
    • 62649085615 scopus 로고    scopus 로고
    • Novel magnetostrictive microcantilever and magnetostrictive nanobars for high performance biological detection
    • Z.-Y. Cheng, S. Q. Li, K. W. Zhang, L. L. Fu, B. A. Chin, Novel magnetostrictive microcantilever and magnetostrictive nanobars for high performance biological detection, Advances in Science and Technology 54 (2008) 19-28.
    • (2008) Advances in Science and Technology , vol.54 , pp. 19-28
    • Cheng, Z.-Y.1    Li, S.Q.2    Zhang, K.W.3    Fu, L.L.4    Chin, B.A.5
  • 18
    • 0033622670 scopus 로고    scopus 로고
    • Remote query magnetostrictive viscosity sensor
    • DOI 10.1016/S0924-4247(99)00288-5
    • P. G. Stoyanov, C. A. Grimes, A remote query magnetostrictive viscosity sensor, Sensors and Actuators A: Physical 80 (2000) 8-14. (Pubitemid 30556993)
    • (2000) Sensors and Actuators, A: Physical , vol.80 , Issue.1 , pp. 8-14
    • Stoyanov, P.G.1    Grimes, C.A.2
  • 19
    • 0035306473 scopus 로고    scopus 로고
    • Acoustic wave technology sensors
    • DOI 10.1109/22.915466, PII S0018948001029052, Microwave Acoustic Devices for Wireless Communications and Sensing
    • B. Drafts, Acoustic wave technology sensors, IEEE Transactions on Microwave Theory and Techniques 49 (2001) 795-802. (Pubitemid 32426381)
    • (2001) IEEE Transactions on Microwave Theory and Techniques , vol.49 , Issue.4 , pp. 795-802
    • Drafts, B.1
  • 20
    • 85126151667 scopus 로고    scopus 로고
    • Surface generated acoustic wave biosensors for the detection of pathogens: A review
    • R. G. María-Isabel, M. I. Carmen, M. B. Angel, A. V. Antonio, Surface generated acoustic wave biosensors for the detection of pathogens: a review, Sensors 9(2009), 5740-5769.
    • (2009) Sensors , vol.9 , pp. 5740-5769
    • María-Isabel, R.G.1    Carmen, M.I.2    Angel, M.B.3    Antonio, A.V.4
  • 21
    • 32944455240 scopus 로고    scopus 로고
    • Biosensor based on magnetostrictive microcantilever
    • S. Li, L. Orona, Z. Li, Z.-Y. Cheng, Biosensor based on magnetostrictive microcantilever, Applied Physics Letters 88 (7) (2006) 073507.
    • (2006) Applied Physics Letters , vol.88 , Issue.7 , pp. 073507
    • Li, S.1    Orona, L.2    Li, Z.3    Cheng, Z.-Y.4
  • 22
    • 3843119792 scopus 로고    scopus 로고
    • Cantilevertransducers as a platform for chemical and biological sensors
    • N. V. Lavrik, M. J. Sepaniak, P. G. Datskos, Cantilevertransducers as a platform for chemical and biological sensors, Review of Scientific Instruments 75 (7) (2004) 2229-2253.
    • (2004) Review of Scientific Instruments , vol.75 , Issue.7 , pp. 2229-2253
    • Lavrik, N.V.1    Sepaniak, M.J.2    Datskos, P.G.3
  • 23
    • 14844362642 scopus 로고    scopus 로고
    • Cantilever-based biosensors
    • DOI 10.1007/s00216-004-2694-y
    • C. Ziegler, Cantilever-based biosensors, Analytical and Bioanalytical Chemistry 379 (7-8) (2004) 946-959. (Pubitemid 40877526)
    • (2004) Analytical and Bioanalytical Chemistry , vol.379 , Issue.7-8 , pp. 946-959
    • Ziegler, C.1
  • 24
    • 62649145485 scopus 로고    scopus 로고
    • Resonance behavior of magnetostrictive micro/milli-cantilever and its application as a biosensor
    • S. Q. Li, L. L. Fu, J. M. Barbaree, Z.-Y. Cheng, Resonance behavior of magnetostrictive micro/milli-cantilever and its application as a biosensor, Sensors and Actuators B: Chemical 137 (2009) 692-699.
    • (2009) Sensors and Actuators B: Chemical , vol.137 , pp. 692-699
    • Li, S.Q.1    Fu, L.L.2    Barbaree, J.M.3    Cheng, Z.-Y.4
  • 25
    • 36849066165 scopus 로고    scopus 로고
    • Magnetostrictive microcantilever as an advanced transducer for biosensors
    • L. Fu, S. Li, K. Zhang, I.-H. Chen, V. A. Petrenko, Z.-Y. Cheng, Magnetostrictive microcantilever as an advanced transducer for biosensors, Sensor 7 (2007) 2929-2941.
    • (2007) Sensor , vol.7 , pp. 2929-2941
    • Fu, L.1    Li, S.2    Zhang, K.3    Chen, I.-H.4    Petrenko, V.A.5    Cheng, Z.-Y.6
  • 26
    • 1942542409 scopus 로고    scopus 로고
    • Attogram detection using nanoelectromechanical oscillators
    • B. Ilic, H. G. Craighead, Attogram detection using nanoelectromechanical oscillators, Journal of Applied Physics 95 (7) (2004) 3694-3703.
    • (2004) Journal of Applied Physics , vol.95 , Issue.7 , pp. 3694-3703
    • Ilic, B.1    Craighead, H.G.2
  • 27
    • 0036470714 scopus 로고    scopus 로고
    • Effect of length, width, and mode on the mass detection sensitivity of piezoelectric unimorph cantilevers
    • J. W. Yi, W. Y. Shih, W. H. Shih, Effect of length, width, and mode on the mass detection sensitivity of piezoelectric unimorph cantilevers, Journal of Applied Physics 91 (2002) 1680-1686.
    • (2002) Journal of Applied Physics , vol.91 , pp. 1680-1686
    • Yi, J.W.1    Shih, W.Y.2    Shih, W.H.3
  • 28
    • 34247612361 scopus 로고    scopus 로고
    • Weighing of biomolecules, single cells and single nanoparticles in fluid
    • DOI 10.1038/nature05741, PII NATURE05741
    • T. P. Burg, M. Godin, S. M. Knudsen, W. J. Shen, G. Carlson, J. S. Foster, KenBabcock, S. R. Manalis, Weighing of biomolecules, single cells and single nanoparticles in fluid, Nature 446 (2007) 1066-1069. (Pubitemid 46676057)
    • (2007) Nature , vol.446 , Issue.7139 , pp. 1066-1069
    • Burg, T.P.1    Godin, M.2    Knudsen, S.M.3    Shen, W.4    Carlson, G.5    Foster, J.S.6    Babcock, K.7    Manalis, S.R.8
  • 29
    • 79957745780 scopus 로고    scopus 로고
    • Detection of bacillus anthracis spores using phage-immobilized magnetostrictive milli/micro cantilevers
    • L. L. Fu, S. Q. Li, K. W. Zhang, I.-H. Chen, J. M. Barbaree, A. X. Zhang, Z.-Y. Cheng, Detection of bacillus anthracis spores using phage-immobilized magnetostrictive milli/micro cantilevers, IEEE Sensors Journal 11 (8) (2011) 1684-1691.
    • (2011) IEEE Sensors Journal , vol.11 , Issue.8 , pp. 1684-1691
    • Fu, L.L.1    Li, S.Q.2    Zhang, K.W.3    Chen, I.-H.4    Barbaree, J.M.5    Zhang, A.X.6    Cheng, Z.-Y.7
  • 34
    • 42949118701 scopus 로고    scopus 로고
    • A wireless, remote-query sensor for real-time detection of Escherichia coli O157:H7 concentrations
    • DOI 10.1016/j.snb.2007.12.036, PII S092540050701009X
    • S. J. Huang, P. F. Pang, X. L. Xiao, L. W. He, QY. Cai, C. A. Grimes, A wireless remote-query sensor for real-time detection of Escherichia coli O157:H7 concentrations, Sensors and Actuators B: Chemical 131 (2008) 489-495. (Pubitemid 351609351)
    • (2008) Sensors and Actuators, B: Chemical , vol.131 , Issue.2 , pp. 489-495
    • Huang, S.1    Pang, P.2    Xiao, X.3    He, L.4    Cai, Q.5    Grimes, C.A.6
  • 39
    • 77953649106 scopus 로고    scopus 로고
    • Nonuniform mass detection using magnetostrictive biosensors operating under multiple harmonic resonance modes
    • S. Q. Li, Z.-Y. Cheng, Nonuniform mass detection using magnetostrictive biosensors operating under multiple harmonic resonance modes, Journal of Applied Physics 107 (2010) 114514.
    • (2010) Journal of Applied Physics , vol.107 , pp. 114514
    • Li, S.Q.1    Cheng, Z.-Y.2
  • 40
    • 34249871080 scopus 로고    scopus 로고
    • Correction for longitudinal mode vibration in thin slender beams
    • C. Liang, S. Morshed, B. C. Prorok, Correction for longitudinal mode vibration in thin slender beams, Applied Physics Letters 90 (2007) 221912.
    • (2007) Applied Physics Letters , vol.90 , pp. 221912
    • Liang, C.1    Morshed, S.2    Prorok, B.C.3
  • 42
    • 38749121322 scopus 로고    scopus 로고
    • Landscape phage as a molecular recognition interface for detection devices
    • DOI 10.1016/j.mejo.2006.11.007, PII S0026269206002618
    • V. A. Petrenko, Landscape phage as a molecular recognition interface for detection devices: review, Microelectronics Journal 39 (2) (2008) 202-207. (Pubitemid 351175676)
    • (2008) Microelectronics Journal , vol.39 , Issue.2 , pp. 202-207
    • Petrenko, V.A.1
  • 43
    • 18144396893 scopus 로고    scopus 로고
    • Detection limits for nanoscale biosensors
    • DOI 10.1021/nl050298x
    • P. E. Sheehan, L. J. Whitman, Detection limits for nanoscale biosensors, Nano Letters 5 (2005) 803-807. (Pubitemid 40609764)
    • (2005) Nano Letters , vol.5 , Issue.4 , pp. 803-807
    • Sheehan, P.E.1    Whitman, L.J.2
  • 47
    • 16644395628 scopus 로고    scopus 로고
    • Design and development of a new piezoelectric linear Inchworm
    • DOI 10.1016/j.mechatronics.2005.02.002, PII S0957415805000309
    • J. Lia, R. Sedaghatia, J. Dargahia, D. Waechter, Design and development of a new piezoelectric linear inchworm actuator, Mechatronics 15 (6) (2005) 651-681. (Pubitemid 40480048)
    • (2005) Mechatronics , vol.15 , Issue.6 , pp. 651-681
    • Li, J.1    Sedaghati, R.2    Dargahi, J.3    Waechter, D.4
  • 48
    • 0031097944 scopus 로고    scopus 로고
    • Developing a linear piezomotor with nanometer resolution and high stiffness
    • PII S1083443597022102
    • B. Zhang, Z. Zhu, Developing a linear piezomotor with nanometer resolution and high stiffness, IEEE/ASME Transactions on Mechatronics 2 (1997) 22-29. (Pubitemid 127772321)
    • (1997) IEEE/ASME Transactions on Mechatronics , vol.2 , Issue.1 , pp. 22-29
    • Zhang, B.1    Zhu, Z.2
  • 49
    • 0036761368 scopus 로고    scopus 로고
    • Design, fabrication, and performance of a flextensional transducer based on electrostrictive poly (vinylidene fluoride-trifluoroethylene) copolymer
    • Z.-Y. Cheng, T.-B. Xu, Q. M. Zhang, R. Mayer, J. Hughes, Design, fabrication, and performance of a flextensional transducer based on electrostrictive poly (vinylidene fluoride-trifluoroethylene) copolymer, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control 49 (9) (2002) 1312-1320.
    • (2002) IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control , vol.49 , Issue.9 , pp. 1312-1320
    • Cheng, Z.-Y.1    Xu, T.-B.2    Zhang, Q.M.3    Mayer, R.4    Hughes, J.5
  • 50
    • 79956024294 scopus 로고    scopus 로고
    • High-performance micromachined unimorph actuators based on electrostrictive poly (vinylidene fluoride-trifluoroethylene) copolymer
    • T.-B. Xu, Z.-Y. Cheng, Q. M. Zhang, High-performance micromachined unimorph actuators based on electrostrictive poly (vinylidene fluoride-trifluoroethylene) copolymer, Applied Physics Letters 80 (2002) 1082-1084.
    • (2002) Applied Physics Letters , vol.80 , pp. 1082-1084
    • Xu, T.-B.1    Cheng, Z.-Y.2    Zhang, Q.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.