메뉴 건너뛰기




Volumn 68, Issue 11, 2013, Pages

Iterative reconstruction and individualized automatic tube current selection reduce radiation dose while maintaining image quality in 320-multidetector computed tomography coronary angiography

Author keywords

[No Author keywords available]

Indexed keywords

GLYCERYL TRINITRATE; METOPROLOL; VERAPAMIL;

EID: 84885021379     PISSN: 00099260     EISSN: 1365229X     Source Type: Journal    
DOI: 10.1016/j.crad.2013.05.098     Document Type: Article
Times cited : (29)

References (29)
  • 1
    • 57149121037 scopus 로고    scopus 로고
    • Diagnostic performance of coronary angiography by 64-row CT
    • J.M. Miller, C.E. Rochitte, and M. Dewey Diagnostic performance of coronary angiography by 64-row CT N Engl J Med 359 2008 2324 2336
    • (2008) N Engl J Med , vol.359 , pp. 2324-2336
    • Miller, J.M.1    Rochitte, C.E.2    Dewey, M.3
  • 2
    • 34447558140 scopus 로고    scopus 로고
    • Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography
    • A.J. Einstein, M.J. Henzlova, and S. Rajagopalan Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography JAMA 298 2007 317 323
    • (2007) JAMA , vol.298 , pp. 317-323
    • Einstein, A.J.1    Henzlova, M.J.2    Rajagopalan, S.3
  • 3
    • 69349096036 scopus 로고    scopus 로고
    • Exposure to low-dose ionizing radiation from medical imaging procedures
    • R. Fazel, H.M. Krumholz, and Y. Wang Exposure to low-dose ionizing radiation from medical imaging procedures N Engl J Med 361 2009 849 857
    • (2009) N Engl J Med , vol.361 , pp. 849-857
    • Fazel, R.1    Krumholz, H.M.2    Wang, Y.3
  • 4
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • D.J. Brenner, and E.J. Hall Computed tomography - an increasing source of radiation exposure N Engl J Med 357 2007 2277 2284
    • (2007) N Engl J Med , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 5
    • 67049116139 scopus 로고    scopus 로고
    • Radiation dose from cardiac computed tomography before and after implementation of radiation dose-reduction techniques
    • G.L. Raff, K.M. Chinnaiyan, and D. Share Radiation dose from cardiac computed tomography before and after implementation of radiation dose-reduction techniques JAMA 301 2009 2340 2348
    • (2009) JAMA , vol.301 , pp. 2340-2348
    • Raff, G.L.1    Chinnaiyan, K.M.2    Share, D.3
  • 6
    • 78649323300 scopus 로고    scopus 로고
    • Effect of a standardized quality-improvement protocol on radiation dose in coronary computed tomographic angiography
    • T.M. Labounty, J.P. Earls, and J. Leipsic Effect of a standardized quality-improvement protocol on radiation dose in coronary computed tomographic angiography Am J Cardiol 106 2010 1663 1667
    • (2010) Am J Cardiol , vol.106 , pp. 1663-1667
    • Labounty, T.M.1    Earls, J.P.2    Leipsic, J.3
  • 7
    • 56349098754 scopus 로고    scopus 로고
    • Radiation dose of cardiac dual-source CT: The effect of tailoring the protocol to patient-specific parameters
    • H. Alkadhi, P. Stolzmann, and H. Scheffel Radiation dose of cardiac dual-source CT: the effect of tailoring the protocol to patient-specific parameters Eur J Radiol 68 2008 385 391
    • (2008) Eur J Radiol , vol.68 , pp. 385-391
    • Alkadhi, H.1    Stolzmann, P.2    Scheffel, H.3
  • 8
    • 84867022029 scopus 로고    scopus 로고
    • Reduction of radiation exposure and improvement of image quality with BMI-adapted prospective cardiac computed tomography and iterative reconstruction
    • W. Hosch, W. Stiller, and D. Mueller Reduction of radiation exposure and improvement of image quality with BMI-adapted prospective cardiac computed tomography and iterative reconstruction Eur J Radiol 81 2011 3568 3576
    • (2011) Eur J Radiol , vol.81 , pp. 3568-3576
    • Hosch, W.1    Stiller, W.2    Mueller, D.3
  • 9
    • 78650561034 scopus 로고    scopus 로고
    • Radiation dose optimisation in dynamic volume CT of the heart: Tube current adaptation based on anterior-posterior chest diameter
    • P. Rogalla, J. Blobel, and S. Kandel Radiation dose optimisation in dynamic volume CT of the heart: tube current adaptation based on anterior-posterior chest diameter Int J Cardiovasc Imaging 26 2010 933 940
    • (2010) Int J Cardiovasc Imaging , vol.26 , pp. 933-940
    • Rogalla, P.1    Blobel, J.2    Kandel, S.3
  • 10
    • 82455194984 scopus 로고    scopus 로고
    • The influence of chest wall tissue composition in determining image noise during cardiac CT
    • N.S. Paul, H. Kashani, and D. Odedra The influence of chest wall tissue composition in determining image noise during cardiac CT AJR Am J Roentgenol 197 2011 1328 1334
    • (2011) AJR Am J Roentgenol , vol.197 , pp. 1328-1334
    • Paul, N.S.1    Kashani, H.2    Odedra, D.3
  • 11
    • 80052175729 scopus 로고    scopus 로고
    • Individualized tube current selection for 64-row cardiac CTA based on analysis of the scout view
    • J. Gao, J. Li, and J. Earls Individualized tube current selection for 64-row cardiac CTA based on analysis of the scout view Eur J Radiol 79 2010 266 271
    • (2010) Eur J Radiol , vol.79 , pp. 266-271
    • Gao, J.1    Li, J.2    Earls, J.3
  • 12
    • 85027936411 scopus 로고    scopus 로고
    • Individually adapted coronary 64-slice CT angiography based on precontrast attenuation values, using different kVp and tube current settings: Evaluation of image quality
    • F. Paul J- Individually adapted coronary 64-slice CT angiography based on precontrast attenuation values, using different kVp and tube current settings: evaluation of image quality Int J Cardiovasc Imaging 27 2011 53 59
    • (2011) Int J Cardiovasc Imaging , vol.27 , pp. 53-59
    • Paul - J, F.1
  • 13
    • 34548174433 scopus 로고    scopus 로고
    • Use of automatic exposure control in multislice computed tomography of the coronaries: Comparison of 16-slice and 64-slice scanner data with conventional coronary angiography
    • A. Deetjen, S. Möllmann, and G. Conradi Use of automatic exposure control in multislice computed tomography of the coronaries: comparison of 16-slice and 64-slice scanner data with conventional coronary angiography Heart 93 2007 1040 1043
    • (2007) Heart , vol.93 , pp. 1040-1043
    • Deetjen, A.1    Möllmann, S.2    Conradi, G.3
  • 14
    • 84856605802 scopus 로고    scopus 로고
    • CT image quality improvement using Adaptive Iterative Dose Reduction with wide-volume acquisition on 320-detector CT
    • A. Gervaise, B. Osemont, and S. Lecocq CT image quality improvement using Adaptive Iterative Dose Reduction with wide-volume acquisition on 320-detector CT Eur Radiol 22 2012 295 301
    • (2012) Eur Radiol , vol.22 , pp. 295-301
    • Gervaise, A.1    Osemont, B.2    Lecocq, S.3
  • 15
    • 79959738631 scopus 로고    scopus 로고
    • Image quality in reduced-dose coronary CT angiography
    • N.V. Gagarina, R. Irwan, and G. Gordina Image quality in reduced-dose coronary CT angiography Acad Radiol 18 2011 984 990
    • (2011) Acad Radiol , vol.18 , pp. 984-990
    • Gagarina, N.V.1    Irwan, R.2    Gordina, G.3
  • 16
    • 77953866167 scopus 로고    scopus 로고
    • Computing effective dose in cardiac CT
    • W. Huda, S. Tipnis, and A. Sterzik Computing effective dose in cardiac CT Phys Med Biol 55 2010 3675 3684
    • (2010) Phys Med Biol , vol.55 , pp. 3675-3684
    • Huda, W.1    Tipnis, S.2    Sterzik, A.3
  • 17
    • 84863724413 scopus 로고    scopus 로고
    • The effect of adaptive iterative dose reduction on image quality in 320-detector row CT coronary angiography
    • F. Tatsugami, M. Matsuki, and G. Nakai The effect of adaptive iterative dose reduction on image quality in 320-detector row CT coronary angiography Br J Radiol 85 2012 e378 e382
    • (2012) Br J Radiol , vol.85
    • Tatsugami, F.1    Matsuki, M.2    Nakai, G.3
  • 18
    • 80054984676 scopus 로고    scopus 로고
    • Iterative reconstruction in image space (IRIS) in cardiac computed tomography: Initial experience
    • M.S. Bittencourt, B. Schmidt, and M. Seltmann Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience Int J Cardiovasc Imaging 27 2010 1081 1087
    • (2010) Int J Cardiovasc Imaging , vol.27 , pp. 1081-1087
    • Bittencourt, M.S.1    Schmidt, B.2    Seltmann, M.3
  • 19
    • 77956825812 scopus 로고    scopus 로고
    • Adaptive statistical iterative reconstruction: Assessment of image noise and image quality in coronary CT angiography
    • J. Leipsic, T.M. Labounty, and B. Heilbron Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography AJR Am J Roentgenol 195 2010 649 654
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 649-654
    • Leipsic, J.1    Labounty, T.M.2    Heilbron, B.3
  • 20
    • 84866987989 scopus 로고    scopus 로고
    • Image quality and radiation dose of low dose coronary CT angiography in obese patients: Sinogram affirmed iterative reconstruction versus filtered back projection
    • R. Wang, U.J. Schoepf, and R. Wu Image quality and radiation dose of low dose coronary CT angiography in obese patients: sinogram affirmed iterative reconstruction versus filtered back projection Eur J Radiol 81 2012 3141 3145
    • (2012) Eur J Radiol , vol.81 , pp. 3141-3145
    • Wang, R.1    Schoepf, U.J.2    Wu, R.3
  • 21
    • 84870459922 scopus 로고    scopus 로고
    • Iterative reconstruction of dual-source coronary CT angiography: Assessment of image quality and radiation dose
    • E.-A. Park, W. Lee, and K.W. Kim Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose Int J Cardiovasc Imaging 28 2011 1775 1786
    • (2011) Int J Cardiovasc Imaging , vol.28 , pp. 1775-1786
    • Park, E.-A.1    Lee, W.2    Kim, K.W.3
  • 22
    • 77956832667 scopus 로고    scopus 로고
    • Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: The ERASIR study
    • J. Leipsic, T.M. Labounty, and B. Heilbron Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study Am J Roentgenol 195 2010 655 660
    • (2010) Am J Roentgenol , vol.195 , pp. 655-660
    • Leipsic, J.1    Labounty, T.M.2    Heilbron, B.3
  • 23
    • 84860319410 scopus 로고    scopus 로고
    • A hybrid iterative reconstruction algorithm that improves the image quality of low-tube-voltage coronary CT angiography
    • S. Oda, D. Utsunomiya, and Y. Funama A hybrid iterative reconstruction algorithm that improves the image quality of low-tube-voltage coronary CT angiography AJR Am J Roentgenol 198 2012 1126 1131
    • (2012) AJR Am J Roentgenol , vol.198 , pp. 1126-1131
    • Oda, S.1    Utsunomiya, D.2    Funama, Y.3
  • 24
    • 79960799961 scopus 로고    scopus 로고
    • Evaluation of heavily calcified vessels with coronary CT angiography: Comparison of iterative and filtered back projection
    • M. Renker, J.W. Nance, and U.J. Schoepf Evaluation of heavily calcified vessels with coronary CT angiography: comparison of iterative and filtered back projection Radiology 260 2011 390 399
    • (2011) Radiology , vol.260 , pp. 390-399
    • Renker, M.1    Nance, J.W.2    Schoepf, U.J.3
  • 25
    • 84871322405 scopus 로고    scopus 로고
    • CT evaluation of coronary artery stents with iterative image reconstruction: Improvements in image quality and potential for radiation dose reduction
    • U. Ebersberger, F. Tricarico, and U.J. Schoepf CT evaluation of coronary artery stents with iterative image reconstruction: improvements in image quality and potential for radiation dose reduction Eur Radiol 31 2012 125 132
    • (2012) Eur Radiol , vol.31 , pp. 125-132
    • Ebersberger, U.1    Tricarico, F.2    Schoepf, U.J.3
  • 26
    • 84870477123 scopus 로고    scopus 로고
    • A novel iterative reconstruction algorithm allows reduced dose multidetector-row CT imaging of mechanical prosthetic heart valves
    • J. Habets, P. Symersky, and B.A. de Mol A novel iterative reconstruction algorithm allows reduced dose multidetector-row CT imaging of mechanical prosthetic heart valves Int J Cardiovasc Imaging 28 2011 1567 1575
    • (2011) Int J Cardiovasc Imaging , vol.28 , pp. 1567-1575
    • Habets, J.1    Symersky, P.2    De Mol, B.A.3
  • 27
    • 69649098260 scopus 로고    scopus 로고
    • Evaluation of attenuation-based tube current control in coronary artery calcium scoring on prospective ECG-triggered 64-detector CT
    • J. Horiguchi, N. Matsuura, and H. Yamamoto Evaluation of attenuation-based tube current control in coronary artery calcium scoring on prospective ECG-triggered 64-detector CT Acad Radiol 16 2009 1231 1240
    • (2009) Acad Radiol , vol.16 , pp. 1231-1240
    • Horiguchi, J.1    Matsuura, N.2    Yamamoto, H.3
  • 28
    • 74749099540 scopus 로고    scopus 로고
    • Patient characteristics as predictors of image quality and diagnostic accuracy of MDCT compared with conventional coronary angiography for detecting coronary artery stenoses: CORE-64 Multicenter International Trial
    • M. Dewey, A.L. Vavere, and A. Arbab-Zadeh Patient characteristics as predictors of image quality and diagnostic accuracy of MDCT compared with conventional coronary angiography for detecting coronary artery stenoses: CORE-64 Multicenter International Trial Am J Roentgenol 194 2010 93 102
    • (2010) Am J Roentgenol , vol.194 , pp. 93-102
    • Dewey, M.1    Vavere, A.L.2    Arbab-Zadeh, A.3
  • 29
    • 41049108031 scopus 로고    scopus 로고
    • Is there a gender difference in noninvasive coronary imaging? Multislice computed tomography for noninvasive detection of coronary stenoses
    • M. Dewey, W. Rutsch, and B. Hamm Is there a gender difference in noninvasive coronary imaging? Multislice computed tomography for noninvasive detection of coronary stenoses BMC Cardiovasc Disord 8 2008 2
    • (2008) BMC Cardiovasc Disord , vol.8 , pp. 2
    • Dewey, M.1    Rutsch, W.2    Hamm, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.