Volumn 79, Issue 2, 2011, Pages 266-271

Individualized tube current selection for 64-row cardiac CTA based on analysis of the scout view

Author keywords

Consistent image quality; Coronary CT angiography; Dose reduction; Individualized scan protocol; Protocol optimization

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONTROLLED STUDY; CORONARY ARTERY OBSTRUCTION; CORONARY COMPUTED TOMOGRAPHIC ANGIOGRAPHY; DIAGNOSTIC ACCURACY; FEMALE; HUMAN; IMAGE QUALITY; MAJOR CLINICAL STUDY; MALE; MATHEMATICAL ANALYSIS; PREDICTIVE VALUE; PRIORITY JOURNAL; RADIATION DOSE; SENSITIVITY AND SPECIFICITY;

EID: 80052175729     PISSN: 0720048X     EISSN: 18727727     Source Type: Journal    
DOI: 10.1016/j.ejrad.2010.04.026     Document Type: Article
Times cited : (11)

References (19)
  • 1
    • 0013092827 scopus 로고    scopus 로고
    • Non-uniform phase coded image reconstruction for cardiac CT
    • J. Hsieh, T. Pan, K.C. Acharya, Y. Shen, and M. Woodford Non-uniform phase coded image reconstruction for cardiac CT Radiology 213 1999 401
    • (1999) Radiology , vol.213 , pp. 401
    • Hsieh, J.1    Pan, T.2    Acharya, K.C.3    Shen, Y.4    Woodford, M.5
  • 2
    • 0034117652 scopus 로고    scopus 로고
    • High temporal resolution for multislice helical computed tomography
    • DOI 10.1118/1.598951
    • K. Taguchi, and H. Anno High temporal resolution for multislice helical computed tomography Med Phys 27 2000 861 872 (Pubitemid 30349994)
    • (2000) Medical Physics , vol.27 , Issue.5 , pp. 861-872
    • Taguchi, K.1    Anno, H.2
  • 3
    • 2542596891 scopus 로고    scopus 로고
    • Pitfalls, artifacts, and remedies in multi-detector row CT coronary angiography
    • H.S. Choi, B.W. Choi, K.O. Choe, D. Choi, K.J. Yoo, and J. Kim Pitfalls, artifacts, and remedies in multi-detector row CT coronary angiography Radiographics 24 2004 787 800 (Pubitemid 38703244)
    • (2004) Radiographics , vol.24 , Issue.3 , pp. 787-800
    • Choi, H.S.1    Choi, B.W.2    Choe, K.O.3    Choi, D.4    Yoo, K.-J.5    Kim, M.-I.6    Kim, J.7
  • 4
    • 33750547401 scopus 로고    scopus 로고
    • Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography
    • DOI 10.1118/1.2361078
    • J. Hsieh, J. Londt, M. Vass, J. Li, X. Tang, and D. Okerlund Step-and-shoot data acquisition and reconstruction for cardiac X-ray computed tomography Med Phys 33 2006 4236 4248 (Pubitemid 44673113)
    • (2006) Medical Physics , vol.33 , Issue.11 , pp. 4236-4248
    • Hsieh, J.1    Londt, J.2    Vass, M.3    Li, J.4    Tang, X.5    Okerlund, D.6
  • 5
    • 36249002355 scopus 로고    scopus 로고
    • Radiation dose from contemporary cardiothoracic multidetector CT protocols with an anthropomorphic female phantom: Implications for cancer induction
    • DOI 10.1148/radiol.2453062046
    • L.M. Hurwitz, R.E. Reiman, and T.T. Yoshizumi Radiation dose from contemporary cardiothoracic multidetector CT protocols with an anthropomorphic female phantom: implications for cancer induction Radiology 245 3 2007 742 750 (Pubitemid 350127344)
    • (2007) Radiology , vol.245 , Issue.3 , pp. 742-750
    • Hurwitz, L.M.1    Reiman, R.E.2    Yoshizumi, T.T.3    Goodman, P.C.4    Toncheva, G.5    Nguyen, G.6    Lowry, C.7
  • 6
    • 33645562681 scopus 로고    scopus 로고
    • CT dose reduction and dose management tools: Overview of available options
    • DOI 10.1148/rg.262055138
    • C. McCollough, M. Bruesewitz, and J. Kofler Jr. CT dose reduction and dose management tools: overview of available options RadioGraphics 26 2006 503 512 (Pubitemid 43515321)
    • (2006) Radiographics , vol.26 , Issue.2 , pp. 503-512
    • McCollough, C.H.1    Bruesewitz, M.R.2    Kofler Jr., J.M.3
  • 7
    • 35148828118 scopus 로고    scopus 로고
    • Dose reduction for CT coronary artery imaging using a special bowtie
    • J. Li, K. Mohr, and D. Okerlund Dose reduction for CT coronary artery imaging using a special bowtie Med Phys 31 2004 1841
    • (2004) Med Phys , vol.31 , pp. 1841
    • Li, J.1    Mohr, K.2    Okerlund, D.3
  • 9
    • 0036580665 scopus 로고    scopus 로고
    • Multislice helical CT of the heart with retrospective ECG gating: Reduction of radiation exposure by ECG-controlled tube current modulation
    • DOI 10.1007/s00330-001-1278-x
    • T.F. Jakobs, C.R. Becker, B. Ohnesorge, T. Flohr, C. Suess, and U.J. Schoepf Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation Eur Radiol 12 2002 1081 1086 (Pubitemid 36940173)
    • (2002) European Radiology , vol.12 , Issue.5 , pp. 1081-1086
    • Jakobs, T.F.1    Becker, C.R.2    Ohnesorge, B.3    Flohr, T.4    Suess, C.5    Schoepf, U.J.6    Reiser, M.F.7
  • 10
    • 40949165279 scopus 로고    scopus 로고
    • Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose
    • J.P. Earls, E.L. Berman, B.A. Urban, C.A. Curry, J.L. Lane, R.S. Jennings, C.C. McCulloch, J. Hsieh, and J.H. Londt Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose Radiology 246 3 2008 742 753
    • (2008) Radiology , vol.246 , Issue.3 , pp. 742-753
    • Earls, J.P.1    Berman, E.L.2    Urban, B.A.3    Curry, C.A.4    Lane, J.L.5    Jennings, R.S.6    McCulloch, C.C.7    Hsieh, J.8    Londt, J.H.9
  • 11
    • 33645830709 scopus 로고    scopus 로고
    • Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis
    • DOI 10.2214/AJR.04.1513
    • S. Rizzo, M. Kalra, and B. Schmidt Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis Am J Roentgenol 186 2006 673 679 (Pubitemid 46100252)
    • (2006) American Journal of Roentgenology , vol.186 , Issue.3 , pp. 673-679
    • Rizzo, S.1    Kalra, M.2    Schmidt, B.3    Dalal, T.4    Suess, C.5    Flohr, T.6    Blake, M.7    Saini, S.8
  • 15
    • 34347226381 scopus 로고    scopus 로고
    • Uniform image quality achieved by tube current modulation using SD of attenuation in coronary CT angiography
    • G. Hur, S. Hong, and S. Kim Uniform image quality achieved by tube current modulation using SD of attenuation in coronary CT angiography Am J Roentgenol 189 2007 188 198
    • (2007) Am J Roentgenol , vol.189 , pp. 188-198
    • Hur, G.1    Hong, S.2    Kim, S.3
  • 16
    • 0023427667 scopus 로고
    • Guidelines for coronary angiography. A report of the American College of Cardiology/American Heart Association Task Force on Assessment of diagnostics and therapeutic Cardiovascular Procedures (Subcommittee on Coronary Angiography)
    • Guidelines for coronary angiography. A report of the American College of Cardiology/American Heart Association Task Force on Assessment of diagnostics and therapeutic Cardiovascular Procedures (Subcommittee on Coronary Angiography). J Am Coll Cardiol 1987; 10(4): 935-950.
    • (1987) J Am Coll Cardiol , vol.10 , Issue.4 , pp. 935-950
  • 17
    • 67849090531 scopus 로고    scopus 로고
    • Options for reducing patient radiation dose with cardiovascular computed tomography
    • S. Halliburton Options for reducing patient radiation dose with cardiovascular computed tomography Int J Cardiovasc Imaging 25 2009 153 164
    • (2009) Int J Cardiovasc Imaging , vol.25 , pp. 153-164
    • Halliburton, S.1
  • 18
    • 67049116139 scopus 로고    scopus 로고
    • Radiation dose from cardiac computed tomography before and after implementation of radiation dose-reduction techniques
    • G.L. Raff, K.M. Chinnaiyan, D.A. Share, T.Y. Goraya, E.A. Kazerooni, M. Mauro, R.E. Gentry, and A. Abidov Radiation dose from cardiac computed tomography before and after implementation of radiation dose-reduction techniques JAMA 301 22 2009 2340 2348
    • (2009) JAMA , vol.301 , Issue.22 , pp. 2340-2348
    • Raff, G.L.1    Chinnaiyan, K.M.2    Share, D.A.3    Goraya, T.Y.4    Kazerooni, E.A.5    Mauro, M.6    Gentry, R.E.7    Abidov, A.8
  • 19
    • 44949221326 scopus 로고    scopus 로고
    • Effect of dose-reduced scan protocols on cardiac coronary image quality with 64-row MDCT: A cardiac phantom study
    • DOI 10.1016/j.ejrad.2007.07.008, PII S0720048X07003646
    • X. Fei, X. Du, P. Li, J. Liao, Y. Shen, and K. Li Effect of dose-reduced scan protocols on cardiac coronary image quality with 64-row MDCT: a cardiac phantom study Eur J Radiol 67 2008 85 91 (Pubitemid 351818232)
    • (2008) European Journal of Radiology , vol.67 , Issue.1 , pp. 85-91
    • Fei, X.1    Du, X.2    Li, P.3    Liao, J.4    Shen, Y.5    Li, K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.