메뉴 건너뛰기




Volumn 28, Issue 7, 2012, Pages 1775-1786

Iterative reconstruction of dual-source coronary CT angiography: Assessment of image quality and radiation dose

Author keywords

Cardiac CT; Coronary angiography; Dual source CT; Iterative reconstruction; Radiation dose

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; CARDIAC IMAGING; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONTROLLED STUDY; DOSIMETRY; FEMALE; FILTERED BACK PROJECTION; HUMAN; IMAGE ANALYSIS; IMAGE DISPLAY; IMAGE QUALITY; IMAGE RECONSTRUCTION; IMAGING AND DISPLAY; INTERMETHOD COMPARISON; ITERATIVE RECONSTRUCTION IN IMAGE SPACE; MAJOR CLINICAL STUDY; MALE; RADIATION DOSE; SIGNAL NOISE RATIO;

EID: 84870459922     PISSN: 15695794     EISSN: 15730743     Source Type: Journal    
DOI: 10.1007/s10554-011-0004-2     Document Type: Article
Times cited : (44)

References (35)
  • 1
    • 0032603548 scopus 로고    scopus 로고
    • Dose reduction in CT by on-line tube current control: Principles and validation on phantoms and cadavers
    • Kalender WA, Wolf H, Suess C, Gies M, Greess H, Bautz WA (1999) Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers. Eur Radiol 9:323-328.
    • (1999) Eur Radiol , vol.9 , pp. 323-328
    • Kalender, W.A.1    Wolf, H.2    Suess, C.3    Gies, M.4    Greess, H.5    Bautz, W.A.6
  • 4
    • 1642389455 scopus 로고    scopus 로고
    • Low-kilovoltage multi-detector row chest CT in adults: Feasibility and effect on image quality and iodine dose
    • DOI 10.1148/radiol.2311030191
    • Sigal-Cinqualbre AB, Hennequin R, Abada HT, Chen X, Paul JF (2004) Low-kilovoltage multi-detector row chest CT in adults: feasibility and effect on image quality and iodine dose. Radiology 231:169-174. (Pubitemid 38375425)
    • (2004) Radiology , vol.231 , Issue.1 , pp. 169-174
    • Sigal-Cinqualbre, A.B.1    Hennequin, R.2    Abada, H.T.3    Chen, X.4    Paul, J.-F.5
  • 5
    • 33745546975 scopus 로고    scopus 로고
    • MDCT of the coronary arteries: Feasibility of low-dose CT with ECG-pulsed tube current modulation to reduce radiation dose
    • DOI 10.2214/AJR.05.0216
    • Abada HT, Larchez C, Daoud B, Sigal-Cinqualbre A, Paul JF (2006) MDCT of the coronary arteries: feasibility of lowdose CT with ECG-pulsed tube current modulation to reduce radiation dose. AJR Am J Roentgenol 186:S387- S390. (Pubitemid 46105409)
    • (2006) American Journal of Roentgenology , vol.186 , Issue.6 SUPPL. A
    • Abada, H.T.1    Larchez, C.2    Daoud, B.3    Sigal-Cinqualbre, A.4    Paul, J.-F.5
  • 7
    • 35348977748 scopus 로고    scopus 로고
    • Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: Prospective randomized study
    • DOI 10.1148/radiol.2452061919
    • Heyer CM, Mohr PS, Lemburg SP, Peters SA, Nicolas V (2007) Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: prospective randomized study. Radiology 245:577-583. (Pubitemid 47612541)
    • (2007) Radiology , vol.245 , Issue.2 , pp. 577-583
    • Heyer, C.M.1    Mohr, P.S.2    Lemburg, S.P.3    Peters, S.A.4    Nicolas, V.5
  • 8
    • 66849138266 scopus 로고    scopus 로고
    • The image quality and radiation dose of 100-kVp versus 120-kVp ECG-gated 16-slice CT coronary angiography
    • Park EA, Lee W, Kang JH, Yin YH, Chung JW, Park JH (2009) The image quality and radiation dose of 100-kVp versus 120-kVp ECG-gated 16-slice CT coronary angiography. Korean J Radiol 10:235-243.
    • (2009) Korean J Radiol , vol.10 , pp. 235-243
    • Park, E.A.1    Lee, W.2    Kang, J.H.3    Yin, Y.H.4    Chung, J.W.5    Park, J.H.6
  • 13
    • 49049116757 scopus 로고    scopus 로고
    • Prospective versus retrospective ECG gating for 64-detector CT of the coronary arteries: Comparison of image quality and patient radiation dose
    • Shuman WP, Branch KR, May JM, Mitsumori LM, Lockhart DW, Dubinsky TJ, Warren BH, Caldwell JH (2008) Prospective versus retrospective ECG gating for 64-detector CT of the coronary arteries: comparison of image quality and patient radiation dose. Radiology 248:431-437.
    • (2008) Radiology , vol.248 , pp. 431-437
    • Shuman, W.P.1    Branch, K.R.2    May, J.M.3    Mitsumori, L.M.4    Lockhart, D.W.5    Dubinsky, T.J.6    Warren, B.H.7    Caldwell, J.H.8
  • 15
    • 77956490090 scopus 로고    scopus 로고
    • Adaptive statistical iterative reconstruction technique for pulmonary CT image quality of the cadaveric lung on standard- and reduced-dose CT
    • Yanagawa M, Honda O, Yoshida S, Kikuyama A, Inoue A, Sumikawa H, Koyama M, Tomiyama N (2010) Adaptive statistical iterative reconstruction technique for pulmonary CT image quality of the cadaveric lung on standard- and reduced-dose CT. Acad Radiol 17:1259-1266.
    • (2010) Acad Radiol , vol.17 , pp. 1259-1266
    • Yanagawa, M.1    Honda, O.2    Yoshida, S.3    Kikuyama, A.4    Inoue, A.5    Sumikawa, H.6    Koyama, M.7    Tomiyama, N.8
  • 16
    • 77954708865 scopus 로고    scopus 로고
    • Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: A pilot study
    • Flicek KT, Hara AK, Silva AC, Wu Q, Peter MB, Johnson CD (2010) Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: a pilot study. AJR Am J Roentgenol 195:126-131.
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 126-131
    • Flicek, K.T.1    Hara, A.K.2    Silva, A.C.3    Wu, Q.4    Peter, M.B.5    Johnson, C.D.6
  • 21
    • 77956841482 scopus 로고    scopus 로고
    • Abdominal CT: Comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients
    • Sagara Y, Hara AK, Pavlicek W, Silva AC, Paden RG, Wu Q (2010) Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients. AJR Am J Roentgenol 195:713-719.
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 713-719
    • Sagara, Y.1    Hara, A.K.2    Pavlicek, W.3    Silva, A.C.4    Paden, R.G.5    Wu, Q.6
  • 22
    • 36249014925 scopus 로고    scopus 로고
    • Effectiveness of dual-source CT coronary angiography for the evaluation of coronary artery disease in patients with atrial fibrillation: Initial experience
    • DOI 10.1148/radiol.2453070094
    • Oncel D, Oncel G, Tastan A (2007) Effectiveness of dualsource CT coronary angiography for the evaluation of coronary artery disease in patients with atrial fibrillation: initial experience. Radiology 245:703-711. (Pubitemid 350127340)
    • (2007) Radiology , vol.245 , Issue.3 , pp. 703-711
    • Oncel, D.1    Oncel, G.2    Tastan, A.3
  • 23
    • 33645749654 scopus 로고    scopus 로고
    • Radiation dose estimates from cardiac multislice computed tomography in daily practice: Impact of different scanning protocols on effective dose estimates
    • DOI 10.1161/CIRCULATIONAHA.105.602490, PII 0000301720060314000008
    • Hausleiter J, Meyer T, Hadamitzky M, Huber E, Zankl M, Martinoff S, Kastrati A, Schomig A (2006) Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation 113:1305-1310. (Pubitemid 43739452)
    • (2006) Circulation , vol.113 , Issue.10 , pp. 1305-1310
    • Hausleiter, J.1    Meyer, T.2    Hadamitzky, M.3    Huber, E.4    Zankl, M.5    Martinoff, S.6    Kastrati, A.7    Schomig, A.8
  • 25
    • 77957358643 scopus 로고    scopus 로고
    • Multisection CT protocols: Sex- and age-specific conversion factors used to determine effective dose from dose-length product
    • Deak PD, Smal Y, Kalender WA (2010) Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product. Radiology 257:158-166.
    • (2010) Radiology , vol.257 , pp. 158-166
    • Deak, P.D.1    Smal, Y.2    Kalender, W.A.3
  • 26
    • 84855310125 scopus 로고    scopus 로고
    • CT radiation dose optimization and estimation: An update for radiologists
    • in press
    • Goo HW (2012) CT radiation dose optimization and estimation: an update for radiologists. Korean J Radiol 13:1-12 (in press).
    • (2012) Korean J Radiol , vol.13 , pp. 1-12
    • Goo, H.W.1
  • 28
    • 79751531405 scopus 로고    scopus 로고
    • Computed tomography- old ideas and new technology
    • Fleischmann D, Boas FE (2011) Computed tomography- old ideas and new technology. Eur Radiol 21:510-517.
    • (2011) Eur Radiol , vol.21 , pp. 510-517
    • Fleischmann, D.1    Boas, F.E.2
  • 29
    • 82955239374 scopus 로고    scopus 로고
    • CT iterative reconstruction in image space: A phantom study
    • Epub ahead of print
    • Ghetti C, Ortenzia O, Serreli G (2011) CT iterative reconstruction in image space: a phantom study. Phys Med (Epub ahead of print).
    • (2011) Phys Med
    • Ghetti, C.1    Ortenzia, O.2    Serreli, G.3
  • 30
    • 79959960464 scopus 로고    scopus 로고
    • Dose reduction in abdominal computed tomography: Intraindividual comparison of image quality of full-dose standard and half-dose iterative reconstructions with dual-source computed tomography
    • May MS, Wust W, Brand M, Stahl C, Allmendinger T, Schmidt B, Uder M, Lell MM (2011) Dose reduction in abdominal computed tomography: intraindividual comparison of image quality of full-dose standard and half-dose iterative reconstructions with dual-source computed tomography. Invest Radiol 46:465-470.
    • (2011) Invest Radiol , vol.46 , pp. 465-470
    • May, M.S.1    Wust, W.2    Brand, M.3    Stahl, C.4    Allmendinger, T.5    Schmidt, B.6    Uder, M.7    Lell, M.M.8
  • 31
    • 79751526184 scopus 로고    scopus 로고
    • Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): Image quality of low-dose CT examinations in 80 patients
    • Pontana F, Duhamel A, Pagniez J, Flohr T, Faivre JB, Hachulla AL, Remy J, Remy-Jardin M (2011) Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients. Eur Radiol 21:636-643.
    • (2011) Eur Radiol , vol.21 , pp. 636-643
    • Pontana, F.1    Duhamel, A.2    Pagniez, J.3    Flohr, T.4    Faivre, J.B.5    Hachulla, A.L.6    Remy, J.7    Remy-Jardin, M.8
  • 32
    • 79751534189 scopus 로고    scopus 로고
    • Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): Evaluation of image noise reduction in 32 patients
    • Pontana F, Pagniez J, Flohr T, Faivre JB, Duhamel A, Remy J, Remy-Jardin M (2011) Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): Evaluation of image noise reduction in 32 patients. Eur Radiol 21:627-635.
    • (2011) Eur Radiol , vol.21 , pp. 627-635
    • Pontana, F.1    Pagniez, J.2    Flohr, T.3    Faivre, J.B.4    Duhamel, A.5    Remy, J.6    Remy-Jardin, M.7
  • 35
    • 79960687077 scopus 로고    scopus 로고
    • Iterative reconstruction algorithm for abdominal multidetector CT at different tube voltages: Assessment of diagnostic accuracy, image quality, and radiation dose in a phantom study
    • Schindera ST, Diedrichsen L, Muller HC, Rusch O, Marin D, Schmidt B, Raupach R, Vock P, Szucs-Farkas Z (2011) Iterative reconstruction algorithm for abdominal multidetector CT at different tube voltages: assessment of diagnostic accuracy, image quality, and radiation dose in a phantom study. Radiology 260:454-462.
    • (2011) Radiology , vol.260 , pp. 454-462
    • Schindera, S.T.1    Diedrichsen, L.2    Muller, H.C.3    Rusch, O.4    Marin, D.5    Schmidt, B.6    Raupach, R.7    Vock, P.8    Szucs-Farkas, Z.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.