메뉴 건너뛰기




Volumn 28, Issue 6, 2012, Pages 1567-1575

A novel iterative reconstruction algorithm allows reduced dose multidetector-row CT imaging of mechanical prosthetic heart valves

Author keywords

Artifacts; Computed tomography; Image noise; Iterative reconstruction; Prosthetic heart valve; Reconstruction algorithm

Indexed keywords

ALGORITHM; ARTICLE; ARTIFACT; CARBOMEDICS PROSTHETIC HEART VALVE; CARDIAC IMAGING; COMPUTED TOMOGRAPHY SCANNER; CONTROLLED STUDY; DIASTOLE; DOSIMETRY; ELECTROCARDIOGRAPHY; HEART VALVE PROSTHESIS; IMAGE QUALITY; IMAGE RECONSTRUCTION; ITERATIVE RECONSTRUCTION ALGORITHM; MULTIDETECTOR COMPUTED TOMOGRAPHY; RADIATION DOSE REDUCTION; SAINT JUDE HEART VALVE PROSTHESIS; SIGNAL NOISE RATIO; SYSTOLE;

EID: 84870477123     PISSN: 15695794     EISSN: 15730743     Source Type: Journal    
DOI: 10.1007/s10554-011-9954-7     Document Type: Article
Times cited : (29)

References (20)
  • 1
    • 62649154662 scopus 로고    scopus 로고
    • Correctness of multidetector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard
    • Tsai IC, Lin YK, Chang Y et al (2009) Correctness of multidetector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard. Eur Radiol 19:857-867
    • (2009) Eur Radiol , vol.19 , pp. 857-867
    • Tsai, I.C.1    Lin, Y.K.2    Chang, Y.3
  • 2
    • 70349498637 scopus 로고    scopus 로고
    • Comparison of multidetector-row computed tomography to echocardiography and fluoroscopy for evaluation of patients with mechanical prosthetic valve obstruction
    • Symersky P, Budde RP, de Mol BA et al (2009) Comparison of multidetector-row computed tomography to echocardiography and fluoroscopy for evaluation of patients with mechanical prosthetic valve obstruction. Am J Cardiol 104:1128-1134
    • (2009) Am J Cardiol , vol.104 , pp. 1128-1134
    • Symersky, P.1    Budde, R.P.2    De Mol, B.A.3
  • 4
    • 58549115527 scopus 로고    scopus 로고
    • Multislice computed tomography in infective endocarditis: Comparison with transesophageal echocardiography and intraoperative findings
    • Feuchtner GM, Stolzmann P, Dichtl W et al (2009) Multislice computed tomography in infective endocarditis: comparison with transesophageal echocardiography and intraoperative findings. J Am Coll Cardiol 53:436-444
    • (2009) J Am Coll Cardiol , vol.53 , pp. 436-444
    • Feuchtner, G.M.1    Stolzmann, P.2    Dichtl, W.3
  • 5
    • 79960966500 scopus 로고    scopus 로고
    • Diagnostic evaluation of left-sided prosthetic heart valve dysfunction
    • Habets J, Budde RP, Symersky P et al (2011) Diagnostic evaluation of left-sided prosthetic heart valve dysfunction. Nat Rev Cardiol 8:466-478
    • (2011) Nat Rev Cardiol , vol.8 , pp. 466-478
    • Habets, J.1    Budde, R.P.2    Symersky, P.3
  • 6
    • 79959379991 scopus 로고    scopus 로고
    • Prosthetic heart valve assessment with multidetector-row CT: Imaging characteristics of 91 valves in 83 patients
    • Habets J, Symersky P, van Herwerden LA et al (2011) Prosthetic heart valve assessment with multidetector-row CT: imaging characteristics of 91 valves in 83 patients. Eur Radiol 21:1390-1396
    • (2011) Eur Radiol , vol.21 , pp. 1390-1396
    • Habets, J.1    Symersky, P.2    Van Herwerden, L.A.3
  • 7
    • 77951585892 scopus 로고    scopus 로고
    • Evaluation of anatomic valve opening and leaflet morphology in aortic valve bioprosthesis by using multidetector CT: Comparison with transthoracic echocardiography
    • Chenot F, Montant P, Goffinet C et al (2010) Evaluation of anatomic valve opening and leaflet morphology in aortic valve bioprosthesis by using multidetector CT: comparison with transthoracic echocardiography. Radiology 255:377-385
    • (2010) Radiology , vol.255 , pp. 377-385
    • Chenot, F.1    Montant, P.2    Goffinet, C.3
  • 8
    • 79751531405 scopus 로고    scopus 로고
    • Computed tomography -old ideas and new technology
    • Fleischmann D, Boas FE (2011) Computed tomography -old ideas and new technology. Eur Radiol 21:510-517
    • (2011) Eur Radiol , vol.21 , pp. 510-517
    • Fleischmann, D.1    Boas, F.E.2
  • 9
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • Lange K, Carson R (1984)EMreconstruction algorithms for emission and transmission tomography. J Comput Assist Tomogr 8:306-316 (Pubitemid 14169679)
    • (1984) Journal of Computer Assisted Tomography , vol.8 , Issue.2 , pp. 306-316
    • Lange, K.1    Carson, R.2
  • 10
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • Shepp LA, Vardi Y (1982) Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imaging 1:113-122 (Pubitemid 13557763)
    • (1982) IEEE Transactions on Medical Imaging , vol.MI-1 , Issue.2 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 11
    • 77956832667 scopus 로고    scopus 로고
    • Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: The ERASIR study
    • Leipsic J, LaBounty TM, Heilbron B et al (2010) Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study. Am J Roentgenol 195:655-660
    • (2010) Am J Roentgenol , vol.195 , pp. 655-660
    • Leipsic, J.1    Labounty, T.M.2    Heilbron, B.3
  • 12
    • 77956825812 scopus 로고    scopus 로고
    • Adaptive statistical iterative reconstruction: Assessment of image noise and image quality in coronary CT angiography
    • Leipsic J, LaBounty TM, Heilbron B et al (2010) Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography. Am J Roentgenol 195:649-654
    • (2010) Am J Roentgenol , vol.195 , pp. 649-654
    • Leipsic, J.1    Labounty, T.M.2    Heilbron, B.3
  • 13
    • 79957734869 scopus 로고    scopus 로고
    • Multidetector-row computed tomography imaging characteristics of mechanical prosthetic valves
    • Symersky P, Budde RPJ, Prokop M et al (2011) Multidetector-row computed tomography imaging characteristics of mechanical prosthetic valves. J Heart Valve Dis 20:216-222
    • (2011) J Heart Valve Dis , vol.20 , pp. 216-222
    • Symersky, P.1    Budde, R.P.J.2    Prokop, M.3
  • 14
    • 0347576136 scopus 로고    scopus 로고
    • Radiation dose and image quality
    • Prokop M, GalanskiM(eds) Thieme, Stuttgart
    • Prokop M (2003) Radiation dose and image quality. In: Prokop M, GalanskiM(eds) Spiral and multislide computed tomography of the body. Thieme, Stuttgart, pp 143-144
    • (2003) Spiral and Multislide Computed Tomography of the Body , pp. 143-144
    • Prokop, M.1
  • 16
    • 79751538632 scopus 로고    scopus 로고
    • Evaluation of two iterative techniques for reducing metal artifacts in computed tomography
    • Boas FE, Fleischmann D (2011) Evaluation of two iterative techniques for reducing metal artifacts in computed tomography. Radiology 259:894-902
    • (2011) Radiology , vol.259 , pp. 894-902
    • Boas, F.E.1    Fleischmann, D.2
  • 17
    • 43449126798 scopus 로고    scopus 로고
    • Initial evaluation of coronary images from 320-detector row computed tomography
    • Rybicki FJ, Otero HJ, Steigner ML et al (2008) Initial evaluation of coronary images from 320-detector row computed tomography. Int J Cardiovasc Imaging 24:535-546
    • (2008) Int J Cardiovasc Imaging , vol.24 , pp. 535-546
    • Rybicki, F.J.1    Otero, H.J.2    Steigner, M.L.3
  • 18
    • 67849090536 scopus 로고    scopus 로고
    • Lowdose prospectively gated 256-slice coronary computed tomographic angiography
    • Weigold WG, Olsezewski ME, Walker MJ (2009) Lowdose prospectively gated 256-slice coronary computed tomographic angiography. Int J Cardiovasc Imaging 25:217-230
    • (2009) Int J Cardiovasc Imaging , vol.25 , pp. 217-230
    • Weigold, W.G.1    Olsezewski, M.E.2    Walker, M.J.3
  • 19
    • 76349094438 scopus 로고    scopus 로고
    • Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition
    • Achenbach S, Marwan M, Ropers D et al (2010) Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition. Eur Heart 31:340-346
    • (2010) Eur Heart , vol.31 , pp. 340-346
    • Achenbach, S.1    Marwan, M.2    Ropers, D.3
  • 20
    • 63449097524 scopus 로고    scopus 로고
    • High-pitch spiral acquisition: A new scan mode for coronary CT angiography
    • Achenbach S, Marwan M, Schepis T et al (2009) High-pitch spiral acquisition: a new scan mode for coronary CT angiography. J Cardiovasc Comput Tomogr 3:117-121
    • (2009) J Cardiovasc Comput Tomogr , vol.3 , pp. 117-121
    • Achenbach, S.1    Marwan, M.2    Schepis, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.