메뉴 건너뛰기




Volumn 19, Issue 5, 2013, Pages 644-647

The O-arm revolution in spine surgery

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER ASSISTED TOMOGRAPHY; COST EFFECTIVENESS ANALYSIS; DECOMPRESSION SURGERY; FLUOROSCOPY; HIP OSTEOTOMY; HUMAN; IMAGING SYSTEM; LETTER; NUCLEAR MAGNETIC RESONANCE IMAGING; O ARM IMAGING SYSTEM; OUTCOME ASSESSMENT; PEDICLE SCREW; SPINE SURGERY; SURGICAL TECHNIQUE; WOUND CARE; BONE SCREW; COMPUTER ASSISTED SURGERY; FEMALE; LUMBAR VERTEBRA; MALE; NEURONAVIGATION; PELVIS; PROCEDURES; SPINE FUSION; SURGERY; UTILIZATION; VERTEBRA; METHODOLOGY; NOTE; UTILIZATION REVIEW;

EID: 84884470358     PISSN: 15475654     EISSN: 15475646     Source Type: Journal    
DOI: 10.3171/2013.5.SPINE13474     Document Type: Letter
Times cited : (16)

References (27)
  • 2
    • 0015855085 scopus 로고
    • Computerized transverse axial scanning of the brain
    • Ambrose J: Computerized transverse axial scanning of the brain. Proc R Soc Med 66:833-834, 1973.
    • (1973) Proc R Soc Med , vol.66 , pp. 833-834
    • Ambrose, J.1
  • 3
    • 84873717659 scopus 로고    scopus 로고
    • O-Arm-based image guidance in minimally invasive spine surgery: Technical note
    • Baaj AA, Beckman J, Smith DA: O-Arm-based image guidance in minimally invasive spine surgery: Technical note. Clin Neurol Neurosurg 115:342-345, 2013.
    • (2013) Clin Neurol Neurosurg , vol.115 , pp. 342-345
    • Baaj, A.A.1    Beckman, J.2    Smith, D.A.3
  • 4
    • 0029403019 scopus 로고
    • Inferring microstructural features and the physiological state of tissues from diffusion-weighted images
    • Basser PJ: Inferring microstructural features and the physiological state of tissues from diffusion-weighted images. NMR Biomed 8:333-344, 1995.
    • (1995) NMR Biomed , vol.8 , pp. 333-344
    • Basser, P.J.1
  • 6
    • 80455150078 scopus 로고    scopus 로고
    • Spinal navigation: Standard preoperative versus intraoperative computed tomography data set acquisition for computer-guidance system: Radiological and clinical study in 100 consecutive patients
    • Costa F, Cardia A, Ortolina A, Fabio G, Zerbi A, Fornari M: Spinal navigation: standard preoperative versus intraoperative computed tomography data set acquisition for computer-guidance system: radiological and clinical study in 100 consecutive patients. Spine (Phila Pa 1976) 36:2094-2098, 2011.
    • (2011) Spine (Phila Pa 1976) , vol.36 , pp. 2094-2098
    • Costa, F.1    Cardia, A.2    Ortolina, A.3    Fabio, G.4    Zerbi, A.5    Fornari, M.6
  • 7
    • 84879778235 scopus 로고    scopus 로고
    • Minimally invasive posterior cervical microforaminotomy in the lower cervical spine and C-T junction assisted by O-arm-based navigation
    • Curto DD, Kim JS, Lee SH: Minimally invasive posterior cervical microforaminotomy in the lower cervical spine and C-T junction assisted by O-arm-based navigation. Comput Aided Surg 18:76-83, 2013.
    • (2013) Comput Aided Surg , vol.18 , pp. 76-83
    • Curto, D.D.1    Kim, J.S.2    Lee, S.H.3
  • 8
    • 0015232094 scopus 로고
    • Tumor detection by nuclear magnetic resonance
    • Damadian R: Tumor detection by nuclear magnetic resonance. Science 171:1151-1153, 1971.
    • (1971) Science , vol.171 , pp. 1151-1153
    • Damadian, R.1
  • 9
    • 0000505920 scopus 로고
    • Roentgenography of the brain after the injection of air into the spinal canal
    • Dandy WE: Roentgenography of the brain after the injection of air into the spinal canal. Ann Surg 70:397-403, 1919.
    • (1919) Ann Surg , vol.70 , pp. 397-403
    • Dandy, W.E.1
  • 10
    • 85052610253 scopus 로고    scopus 로고
    • Application of microscope integrated indocyanine green video-angiography during microneurosurgical treatment of intracranial aneurysms: A review
    • Dashti R, Laakso A, Niemelä M, Porras M, Celik O, Navratil O, et al: Application of microscope integrated indocyanine green video-angiography during microneurosurgical treatment of intracranial aneurysms: A review. Acta Neurochir Suppl 107:107-109, 2010.
    • (2010) Acta Neurochir Suppl , vol.107 , pp. 107-109
    • Dashti, R.1    Laakso, A.2    Niemelä, M.3    Porras, M.4    Celik, O.5    Navratil, O.6
  • 11
    • 67449168359 scopus 로고    scopus 로고
    • Intraoperative angiography should be standard in cerebral aneurysm surgery
    • Friedman JA, Kumar R: Intraoperative angiography should be standard in cerebral aneurysm surgery. BMC Surg 9:7, 2009.
    • (2009) BMC Surg , vol.9 , pp. 7
    • Friedman, J.A.1    Kumar, R.2
  • 12
    • 80655147972 scopus 로고    scopus 로고
    • Intraoperative, full-rotation, three-dimensional image (O-arm)-based navigation system for cervical pedicle screw insertion
    • Clinical article
    • Ishikawa Y, Kanemura T, Yoshida G, Matsumoto A, Ito Z, Taushi R, et al: Intraoperative, full-rotation, three-dimensional image (O-arm)-based navigation system for cervical pedicle screw insertion. Clinical article. J Neurosurg Spine 15:472-478, 2011.
    • (2011) J Neurosurg Spine , vol.15 , pp. 472-478
    • Ishikawa, Y.1    Kanemura, T.2    Yoshida, G.3    Matsumoto, A.4    Ito, Z.5    Taushi, R.6
  • 13
    • 84884476403 scopus 로고    scopus 로고
    • Combined S-1 and S-2 sacral alar-iliac screws as a salvage technique for pelvic fixation after pseudarthrosis and lumbosacropelvic instability
    • Technical note
    • Mattei TA, Fassett DR: Combined S-1 and S-2 sacral alar-iliac screws as a salvage technique for pelvic fixation after pseudarthrosis and lumbosacropelvic instability. Technical note. J Neurosurg Spine 19:321-330, 2013.
    • (2013) J Neurosurg Spine , vol.19 , pp. 321-330
    • Mattei, T.A.1    Fassett, D.R.2
  • 14
    • 84878410146 scopus 로고    scopus 로고
    • Low-profile pelvic fixation with sacral alar-iliac screws
    • Mattei TA, Fassett DR: Low-profile pelvic fixation with sacral alar-iliac screws. Acta Neurochir (Wien) 155:293-297, 2013.
    • (2013) Acta Neurochir (Wien) , vol.155 , pp. 293-297
    • Mattei, T.A.1    Fassett, D.R.2
  • 15
    • 77249148879 scopus 로고    scopus 로고
    • Free-hand technique for thoracolumbar pedicle screw instrumentation: Critical appraisal of current state-of-art
    • Mattei TA, Meneses MS, Milano JB, Ramina R: "Free-hand" technique for thoracolumbar pedicle screw instrumentation: critical appraisal of current "state-of-art." Neurol India 57: 715-721, 2009.
    • (2009) Neurol India , vol.57 , pp. 715-721
    • Mattei, T.A.1    Meneses, M.S.2    Milano, J.B.3    Ramina, R.4
  • 16
    • 79958839833 scopus 로고    scopus 로고
    • Accuracy of free-hand technique for instrumentation of thoracolumbar spine
    • Letter
    • Mattei TA, Milano JB: Accuracy of "free-hand technique" for instrumentation of thoracolumbar spine. Neurosurgery 69: E265-E267, 2011 (Letter).
    • (2011) Neurosurgery , vol.69
    • Mattei, T.A.1    Milano, J.B.2
  • 17
    • 49749199774 scopus 로고
    • Extradural haematoma: Observation on 125 cases
    • McKissock W, Taylor JC, Bloom WH, Till K: Extradural haematoma: observation on 125 cases. Lancet 2:167-172, 1960.
    • (1960) Lancet , vol.2 , pp. 167-172
    • Mckissock, W.1    Taylor, J.C.2    Bloom, W.H.3    Till, K.4
  • 18
    • 84877737565 scopus 로고    scopus 로고
    • Placement of thoracic transvertebral pedicle screws using 3D image guidance
    • Technical note
    • Nottmeier EW, Pirris SM: Placement of thoracic transvertebral pedicle screws using 3D image guidance. Technical note. J Neurosurg Spine 18:479-483, 2013.
    • (2013) J Neurosurg Spine , vol.18 , pp. 479-483
    • Nottmeier, E.W.1    Pirris, S.M.2
  • 21
    • 19544368795 scopus 로고    scopus 로고
    • Evaluation of intra-operative ultrasound imaging in brain tumor resection: A prospective study
    • DOI 10.1179/016164105X40039
    • Renner C, Lindner D, Schneider JP, Meixensberger J: Evaluation of intra-operative ultrasound imaging in brain tumor resection: A prospective study. Neurol Res 27:351-357, 2005. (Pubitemid 40734693)
    • (2005) Neurological Research , vol.27 , Issue.4 , pp. 351-357
    • Renner, C.1    Lindner, D.2    Schneider, J.P.3    Meixensberger, J.4
  • 23
    • 84863092226 scopus 로고    scopus 로고
    • Intra-operative cone-beam CT (O-arm) and stereotactic navigation in acute spinal trauma surgery
    • Schouten R, Lee R, Boyd M, Paquette S, Dvorak M, Kwon BK, et al: Intra-operative cone-beam CT (O-arm) and stereotactic navigation in acute spinal trauma surgery. J Clin Neurosci 19:1137-1143, 2012.
    • (2012) J Clin Neurosci , vol.19 , pp. 1137-1143
    • Schouten, R.1    Lee, R.2    Boyd, M.3    Paquette, S.4    Dvorak, M.5    Kwon, B.K.6
  • 24
    • 84937163478 scopus 로고    scopus 로고
    • Prospective comparison study between the fluoroscopy guided and navigation coupled with o-arm® guided pedicle screw placement in the thoracic and lumbosacral spines
    • epub ahead of print
    • Shin MH, Hur JW, Ryu KS, Park CK: Prospective comparison study between the fluoroscopy guided and navigation coupled with O-arm® Guided pedicle screw placement in the thoracic and lumbosacral spines. J Spinal Disord Tech [epub ahead of print], 2013.
    • (2013) J Spinal Disord Tech
    • Shin, M.H.1    Hur, J.W.2    Ryu, K.S.3    Park, C.K.4
  • 25
    • 80052604137 scopus 로고    scopus 로고
    • Computer tomography assessment of pedicle screw placement in lumbar and sacral spine: Comparison between free-hand and O-arm based navigation techniques
    • Silbermann J, Riese F, Allam Y, Reichert T, Koeppert H, Gutberlet M: Computer tomography assessment of pedicle screw placement in lumbar and sacral spine: comparison between free-hand and O-arm based navigation techniques. Eur Spine J 20:875-881, 2011.
    • (2011) Eur Spine J , vol.20 , pp. 875-881
    • Silbermann, J.1    Riese, F.2    Allam, Y.3    Reichert, T.4    Koeppert, H.5    Gutberlet, M.6
  • 26
    • 84870956561 scopus 로고    scopus 로고
    • A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the o-arm imaging system and stealthstation navigation
    • Van de Kelft E, Costa F, Van der Planken D, Schils F: A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation Navigation. Spine (Phila Pa 1976) 37:E1580-E1587, 2012.
    • (2012) Spine (Phila Pa 1976) , vol.37
    • Van De Kelft, E.1    Costa, F.2    Van Der Planken, D.3    Schils, F.4
  • 27
    • 84874114851 scopus 로고    scopus 로고
    • Comparison of cranial facet joint violation rates between open and percutaneous pedicle screw placement using intraoperative 3-D CT (O-arm) computer navigation
    • Yson SC, Sembrano JN, Sanders PC, Santos ER, Ledonio CG, Polly DW Jr: Comparison of cranial facet joint violation rates between open and percutaneous pedicle screw placement using intraoperative 3-D CT (O-arm) computer navigation. Spine (Phila Pa 1976) 38:E251-E258, 2013.
    • (2013) Spine (Phila Pa 1976) , vol.38
    • Yson, S.C.1    Sembrano, J.N.2    Sanders, P.C.3    Santos, E.R.4    Ledonio, C.G.5    Polly Jr., D.W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.