메뉴 건너뛰기




Volumn 57, Issue 6, 2009, Pages 715-721

"free-hand" technique for thoracolumbar pedicle screw instrumentation: Critical appraisal of current "state-of-Art"

Author keywords

Free hand technique; Pedicle anatomy; Pedicle screw instrumentation; Posterior spinal fixation; Thoracolumbar fractures

Indexed keywords

COMPUTER ASSISTED TOMOGRAPHY; ELECTRONEUROLOGY; FLUOROSCOPY; HUMAN; LUMBOSACRAL SPINE; NEUROIMAGING; NEURONAVIGATION; OSTEOTOMY; PEDICLE SCREW; REVIEW; SPINE STABILIZATION; SURGICAL TECHNIQUE; THORACIC SPINAL CORD; THORACOLUMBAR SPINE;

EID: 77249148879     PISSN: 00283886     EISSN: 19984022     Source Type: Journal    
DOI: 10.4103/0028-3886.59465     Document Type: Review
Times cited : (37)

References (32)
  • 1
    • 0022551914 scopus 로고
    • Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates
    • Roy-Camille R, Sailant G, Mazel C. Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates. Orthop Clin North Am 1986;17:147-159 (Pubitemid 16047443)
    • (1986) Orthopedic Clinics of North America , vol.17 , Issue.1 , pp. 147-159
    • Roy-Camille, R.1    Saillant, G.2    Mazel, Ch.3
  • 3
    • 33645299534 scopus 로고    scopus 로고
    • Posterior thoracic segmental pedicle screw instrumentation: Evolving methods of safe and effective placement
    • Zeiller SC, Lee J, Lim M, Vaccaro AR. Posterior thoracic segmental pedicle screw instrumentation: Evolving methods of safe and effective placement. Neurol India 2005;53:458-465
    • (2005) Neurol India , vol.53 , pp. 458-465
    • Zeiller, S.C.1    Lee, J.2    Lim, M.3    Vaccaro, A.R.4
  • 4
    • 33847083437 scopus 로고    scopus 로고
    • A prospective randomized study of unilateral versus bilateral instrumented posterolateral lumbar fusion in degenerative spondylolisthesis
    • Fernández-Fairen M, Sala P, Ramírez H, Gil J. A prospective randomized study of unilateral versus bilateral instrumented posterolateral lumbar fusion in degenerative spondylolisthesis. Spine 2007;32:395-401.
    • (2007) Spine , vol.32 , pp. 395-401
    • Fernández-Fairen, M.1    Sala, P.2    Ramírez, H.3    Gil, J.4
  • 6
    • 37149002401 scopus 로고    scopus 로고
    • Pedicle screw fixation against burst fracture of thoracolumbar vertebrae
    • Lü FX, Huang Y, Zhang Q, Shi FL, Zhao DS, Hu Q. Pedicle screw fixation against burst fracture of thoracolumbar vertebrae. Chin J Traumatol 2007;10:349-352
    • (2007) Chin J Traumatol , vol.10 , pp. 349-352
    • Lü, F.X.1    Huang, Y.2    Zhang, Q.3    Shi, F.L.4    Zhao, D.S.5    Hu, Q.6
  • 7
    • 0031413907 scopus 로고    scopus 로고
    • Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis
    • Liljenqvist UR, Halm HF, Link TM. Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis. Spine 1997;22:2239-2245
    • (1997) Spine , vol.22 , pp. 2239-2245
    • Liljenqvist, U.R.1    Halm, H.F.2    Link, T.M.3
  • 8
    • 0034466194 scopus 로고    scopus 로고
    • Safety and efficacy of pedicle screw placement for adult spinal deformity with a pedicle-probing conventional anatomic technique
    • Boachie-Adjei O, Girardi FP, Bansal M, Rawlins BA. Safety and efficacy of pedicle screw placement for adult spinal deformity with a pedicle-probing conventional anatomic technique. J Spinal Disord 2000;13:496-500.
    • (2000) J Spinal Disord , vol.13 , pp. 496-500
    • Boachie-Adjei, O.1    Girardi, F.P.2    Bansal, M.3    Rawlins, B.A.4
  • 9
    • 0032920802 scopus 로고    scopus 로고
    • Estudo morfométrico do pedículo das vértebras torácicas e lombares
    • Defino HLA, Mauad Filho J. Estudo morfométrico do pedículo das vértebras torácicas e lombares. Rev Bras Ortop 1999;34:97-108.
    • (1999) Rev Bras Ortop , vol.34 , pp. 97-108
    • Defino, H.L.A.1    Mauad Filho, J.2
  • 10
    • 0033555322 scopus 로고    scopus 로고
    • Pedicle instrumentation in the thoracic spine. A morphometric and cadaveric study for placement of screws
    • Cinotti G, Gumina S, Ripani M, Postacchini F. Pedicle instrumentation in the thoracic spine. A morphometric and cadaveric study for placement of screws. Spine 1999;24:114-119
    • (1999) Spine , vol.24 , pp. 114-119
    • Cinotti, G.1    Gumina, S.2    Ripani, M.3    Postacchini, F.4
  • 11
    • 0031417450 scopus 로고    scopus 로고
    • Anatomic relations of the thoracic pedicle to the adjacent neural structures
    • Ebraheim NA, Jabaly G, Xu R, Yeasting RA. Anatomic relations of the thoracic pedicle to the adjacent neural structures. Spine 1997;22:1553-1556
    • (1997) Spine , vol.22 , pp. 1553-1556
    • Ebraheim, N.A.1    Jabaly, G.2    Xu, R.3    Yeasting, R.A.4
  • 13
    • 0023790873 scopus 로고
    • Spinal pedicle fixation: Reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement
    • Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S. Spinal pedicle fixation: Reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 1988;13:1012-1018
    • (1988) Spine , vol.13 , pp. 1012-1018
    • Weinstein, J.N.1    Spratt, K.F.2    Spengler, D.3    Brick, C.4    Reid, S.5
  • 14
    • 0030022014 scopus 로고    scopus 로고
    • Internal architecture of the thoracic pedicle. An anatomic study
    • Kothe R, O'Holleran JD, Liu W, Panjabi MM. Internal architecture of the thoracic pedicle. An anatomic study. Spine 1996;21:264-270
    • (1996) Spine , vol.21 , pp. 264-270
    • Kothe, R.1    O'Holleran, J.D.2    Liu, W.3    Panjabi, M.M.4
  • 15
    • 0742269914 scopus 로고    scopus 로고
    • Free hand pedicle screw placement in the thoracic spine: Is it safe?
    • Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew KD. Free hand pedicle screw placement in the thoracic spine: Is it safe? Spine 2004;29:333-342
    • (2004) Spine , vol.29 , pp. 333-342
    • Kim, Y.J.1    Lenke, L.G.2    Bridwell, K.H.3    Cho, Y.S.4    Riew, K.D.5
  • 16
    • 52649105308 scopus 로고    scopus 로고
    • Ideal entry point for the thoracic pedicle screw during the free hand technique
    • Chung KJ, Suh SH, Desai S, Song HR. Ideal entry point for the thoracic pedicle screw during the free hand technique. Int Orthop 2008;32:657-665
    • (2008) Int Orthop , vol.32 , pp. 657-665
    • Chung, K.J.1    Suh, S.H.2    Desai, S.3    Song, H.R.4
  • 18
    • 0031439898 scopus 로고    scopus 로고
    • Reliability of pedicle screw assessment utilizing plain radiographs versus CT reconstruction
    • Berlemann U, Heine P, Müller U, Stoupis C, Schwarzenbach O. Reliability of pedicle screw assessment utilizing plain radiographs versus CT reconstruction. Eur Spine J 1997;6:406-410
    • (1997) Eur Spine J , vol.6 , pp. 406-410
    • Berlemann, U.1    Heine, P.2    Müller, U.3    Stoupis, C.4    Schwarzenbach, O.5
  • 19
    • 0029044493 scopus 로고
    • Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography
    • Farber GL, Place HM, Mazur RA, Jones DE, Damiano TR. Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography. Spine 1995;20:1494-1499
    • (1995) Spine , vol.20 , pp. 1494-1499
    • Farber, G.L.1    Place, H.M.2    Mazur, R.A.3    Jones, D.E.4    Damiano, T.R.5
  • 20
    • 0031431918 scopus 로고    scopus 로고
    • Accuracy of using computed tomography to identify pedicle screw placement in cadaveric human lumbar spine
    • Yoo JU, Ghanayem A, Petersilge C, Lewin J. Accuracy of using computed tomography to identify pedicle screw placement in cadaveric human lumbar spine. Spine 1997;22:2688-2691
    • (1997) Spine , vol.22 , pp. 2688-2691
    • Yoo, J.U.1    Ghanayem, A.2    Petersilge, C.3    Lewin, J.4
  • 22
    • 0032076473 scopus 로고    scopus 로고
    • Anatomic considerations of pedicle screw placement in the thoracic spine: Roy-Camille technique versus open-lamina technique
    • Xu R, Ebraheim NA, Ou Y, Yeasting RA. Anatomic considerations of pedicle screw placement in the thoracic spine: Roy-Camille technique versus open-lamina technique. Spine 1998;23:1065-1068
    • (1998) Spine , vol.23 , pp. 1065-1068
    • Xu, R.1    Ebraheim, N.A.2    Ou, Y.3    Yeasting, R.A.4
  • 23
    • 0025267440 scopus 로고
    • Accuracy of pedicular screw placement in vivo
    • Gertzbein SD, Robbins SE. Accuracy of pedicular screw placement in vivo. Spine 1990;15: 11-15
    • (1990) Spine , vol.15 , pp. 11-15
    • Gertzbein, S.D.1    Robbins, S.E.2
  • 25
    • 33745788417 scopus 로고    scopus 로고
    • Accuracy of pedicle screw placement for lumbar fusion using anatomic landmarks versus open laminectomy: A comparison of two surgical techniques in cadaveric specimens
    • Karim A, Mukherjee D, Gonzalez-Cruz J, Ogden A, Smith D, Nanda A. Accuracy of pedicle screw placement for lumbar fusion using anatomic landmarks versus open laminectomy: A comparison of two surgical techniques in cadaveric specimens. Neurosurgery 2006;59:13-19
    • (2006) Neurosurgery , vol.59 , pp. 13-19
    • Karim, A.1    Mukherjee, D.2    Gonzalez-Cruz, J.3    Ogden, A.4    Smith, D.5    Nanda, A.6
  • 26
    • 0028292402 scopus 로고
    • Pedicle screw fixation in the spine
    • Mulholland RC. Pedicle screw fixation in the spine. J Bone Joint Surg Br 1994;76:517-519
    • (1994) J Bone Joint Surg Br , vol.76 , pp. 517-519
    • Mulholland, R.C.1
  • 27
    • 0037227158 scopus 로고    scopus 로고
    • Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries: Technique and short-term complications
    • Carbone JJ, Tortolani PJ, Quartararo LG. Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries: Technique and short-term complications. Spine 2003;28:91-97
    • (2003) Spine , vol.28 , pp. 91-97
    • Carbone, J.J.1    Tortolani, P.J.2    Quartararo, L.G.3
  • 28
    • 0030611301 scopus 로고    scopus 로고
    • Computer-assisted orthopedic surgery. From pedicle screw insertion to further applications
    • Berlemann U, Langlotz F, Langlotz U, Nolte LP. Computer-assisted orthopedic surgery. From pedicle screw insertion to further applications. Orthopade 1997;26:463-469
    • (1997) Orthopade , vol.26 , pp. 463-469
    • Berlemann, U.1    Langlotz, F.2    Langlotz, U.3    Nolte, L.P.4
  • 30
    • 0037397647 scopus 로고    scopus 로고
    • Computer-assisted orthopaedic surgery: Do we need CAOS?
    • Sikorski JM, Chauhan S. Computer-assisted orthopaedic surgery: Do we need CAOS? J Bone Joint Surg Br 2003;85:319-323
    • (2003) J Bone Joint Surg Br , vol.85 , pp. 319-323
    • Sikorski, J.M.1    Chauhan, S.2
  • 32
    • 43049106488 scopus 로고    scopus 로고
    • Free-hand pedicle screw placement during revision spinal surgery: Analysis of 552 screws
    • Kim YW, Lenke LG, Kim YJ, Bridwell KH, Kim YB, Watanabe K, et al. Free-hand pedicle screw placement during revision spinal surgery: Analysis of 552 screws. Spine 2008;10:1141-1148
    • (2008) Spine , vol.10 , pp. 1141-1148
    • Kim, Y.W.1    Lenke, L.G.2    Kim, Y.J.3    Bridwell, K.H.4    Kim, Y.B.5    Watanabe, K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.