메뉴 건너뛰기




Volumn 36, Issue 24, 2011, Pages 2094-2098

Spinal navigation: Standard preoperative versus intraoperative computed tomography data set acquisition for computer-guidance system: Radiological and clinical study in 100 consecutive patients

Author keywords

accuracy; imageguided surgery; pedicle screw; safety; spinal fixation; spinal navigation system

Indexed keywords

ADULT; AGED; ARTICLE; COMPUTER ASSISTED RADIOGRAPHY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; FEMALE; FLUOROSCOPY; HUMAN; INTRAOPERATIVE PERIOD; LUMBAR DEGENERATIVE SPONDYLOLISTHESIS; MAJOR CLINICAL STUDY; MALE; PEDICLE SCREW; PREOPERATIVE PERIOD; PRIORITY JOURNAL; SPONDYLOLISTHESIS;

EID: 80455150078     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/BRS.0b013e318201129d     Document Type: Article
Times cited : (97)

References (29)
  • 1
    • 80455131760 scopus 로고    scopus 로고
    • Transpedicular screw fixations
    • Kim H, ed Philadelphia, PA Saunders Elsevier
    • Zhang HY , Kim DH . Transpedicular screw fi xations . In: Kim H , ed. Transpedicular Screw Fixations. Philadelphia, PA: Saunders Elsevier , 2006 ; 239-45
    • (2006) Transpedicular Screw Fixations , pp. 239-45
    • Zhang, H.Y.1    Kim, D.H.2
  • 2
    • 0742269914 scopus 로고    scopus 로고
    • Free Hand Pedicle Screw Placement in the Thoracic Spine: Is it Safe
    • DOI 10.1097/01.BRS.0000109983.12113.9B
    • Kim YJ , Lenke LG , Bridwell KH , et al. Free hand pedicle screw placement in the thoracic spine: is it safe ? Spine 2004 ; 29 : 333-42 (Pubitemid 38155737)
    • (2004) Spine , vol.29 , Issue.3 , pp. 333-342
    • Kim, Y.J.1    Lenke, L.G.2    Bridwell, K.H.3    Cho, Y.S.4    Riew, K.D.5
  • 3
    • 33846683025 scopus 로고    scopus 로고
    • Pedicle screw placement accuracy: A meta-analysis
    • DOI 10.1097/01.brs.0000254048.79024.8b, PII 0000763220070201000022
    • Kosmopoulos V , Schizas C . Pedicle screw placement accuracy: a meta-analysis . Spine 2007 ; 3 : E111-20 (Pubitemid 46197463)
    • (2007) Spine , vol.32 , Issue.3
    • Kosmopoulos, V.1    Schizas, C.2
  • 4
    • 0029893644 scopus 로고    scopus 로고
    • Accuracy of pedicle screw placement in lumbar vertebrae
    • DOI 10.1097/00007632-199606010-00008
    • Castro WH , Halm H , Jerosch J , et al. Accuracy of pedicle screw placement in lumbar vertebrae . Spine 1996 ; 21 : 1320-4 (Pubitemid 26169507)
    • (1996) Spine , vol.21 , Issue.11 , pp. 1320-1324
    • Castro, W.H.M.1    Halm, H.2    Jerosch, J.3    Malms, J.4    Steinbeck, J.5    Blasius, S.6
  • 6
  • 7
    • 0029044493 scopus 로고
    • Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography
    • Farber GL , Place HM , Mazur RA , et al. Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography . Spine 1995 ; 20 : 1494-99
    • (1995) Spine , vol.20 , pp. 1494-99
    • Farber, G.L.1    Place, H.M.2    Mazur, R.A.3
  • 8
    • 0025267440 scopus 로고
    • Accuracy of pedicular screw placement in vivo
    • Gertzbein SD , Robbins SE . Accuracy of pedicular screw placement in vivo . Spine 1990 ; 15 : 11-4 (Pubitemid 20102491)
    • (1990) Spine , vol.15 , Issue.1 , pp. 11-14
    • Gertzbein, S.D.1    Robbins, S.E.2
  • 11
    • 0035260780 scopus 로고    scopus 로고
    • Lumbar pedicle: Surgical anatomic evaluation and relationships
    • Attar A , Ugur HC , Uz A , et al. Lumbar pedicle: surgical anatomic evaluation and relationships . Eur Spine J 2001 ; 10 : 10-5
    • (2001) Eur Spine J , vol.10 , pp. 10-5
    • Attar, A.1    Ugur, H.C.2    Uz, A.3
  • 13
    • 0026445667 scopus 로고
    • Anatomic and technical considerations of pedicle screw fi xation
    • Weinstein JN , Rydevik BL , Rauschning W . Anatomic and technical considerations of pedicle screw fi xation . Clin Orthop Relat Res 1992 ; 284 : 34-46
    • (1992) Clin Orthop Relat Res , vol.284 , pp. 34-46
    • Weinstein, J.N.1    Rydevik, B.L.2    Rauschning, W.3
  • 14
    • 0030926450 scopus 로고    scopus 로고
    • Improved accuracy of pedicle screw insertion with computer-assisted surgery
    • Laine T , Schlenzka D , Mäitalo K , et al. Improved accuracy of pedicle screw insertion with computer-assisted surgery . Spine 1997 ; 22 : 1254-8
    • (1997) Spine , vol.22 , pp. 1254-8
    • Laine, T.1    Schlenzka, D.2    Mäitalo, K.3
  • 15
    • 68349104323 scopus 로고    scopus 로고
    • Image-guided pedicle screw insertion accuracy: A meta-analysis
    • Tian NF , Xu HZ . Image-guided pedicle screw insertion accuracy: a meta-analysis . Int Orthop 2009 ; 33 : 895-903
    • (2009) Int Orthop , vol.33 , pp. 895-903
    • Tian, N.F.1    Xu, H.Z.2
  • 17
    • 0042568676 scopus 로고    scopus 로고
    • Intraoperative spinal navigation
    • Holly LT , Foley KT . Intraoperative spinal navigation . Spine 2003 ; 15S : S54-61 (Pubitemid 36959584)
    • (2003) Spine , vol.28 , Issue.SUPPL.
    • Holly, L.T.1    Foley, K.T.2
  • 18
    • 0025267440 scopus 로고
    • Accuracy of pedicular screw placement in vivo
    • Gertzbein SD , Robbins SE . Accuracy of pedicular screw placement in vivo . Spine 1990 ; 15 : 11-4 (Pubitemid 20102491)
    • (1990) Spine , vol.15 , Issue.1 , pp. 11-14
    • Gertzbein, S.D.1    Robbins, S.E.2
  • 19
    • 46149126169 scopus 로고    scopus 로고
    • Pedicle screw insertion: Computed tomography versus fl uoroscopic image guidance
    • Fu TS , Wong CB , Tsai TT , et al. Pedicle screw insertion: computed tomography versus fl uoroscopic image guidance . Int Orthop 2008 ; 32 : 517-21
    • (2008) Int Orthop , vol.32 , pp. 517-21
    • Fu, T.S.1    Wong, C.B.2    Tsai, T.T.3
  • 20
    • 0034491195 scopus 로고    scopus 로고
    • Computer-assisted fluoroscopic targeting system for pedicle screw insertion
    • Choi WW , Green BA , Levi AD . Computer-assisted fl uoroscopic targeting system for pedicle screw insertion . Neurosurgery 2000 ; 47 : 872-8 (Pubitemid 32103663)
    • (2000) Neurosurgery , vol.47 , Issue.4 , pp. 872-878
    • Choi, W.W.1    Green, B.A.2    Levi, A.D.O.3
  • 21
    • 67651149876 scopus 로고    scopus 로고
    • Intraoperative computed tomography with integrated navigation system in a multidisciplinary operating suite
    • discussion 239-40
    • Uhl E , Zausinger S , Morhard D , et al. Intraoperative computed tomography with integrated navigation system in a multidisciplinary operating suite . Neurosurgery 2009 ; 64 : 231-9;discussion 239-40
    • (2009) Neurosurgery , vol.64 , pp. 231-239
    • Uhl, E.1    Zausinger, S.2    Morhard, D.3
  • 22
    • 58149291992 scopus 로고    scopus 로고
    • Comparison of radiation exposure in lumbar pedicle screw placement with fl uoroscopy vs computer-assisted image guidance with intraoperative threedimensional imaging
    • Smith HE , Welsch MD , Sasso RC , et al. Comparison of radiation exposure in lumbar pedicle screw placement with fl uoroscopy vs computer-assisted image guidance with intraoperative threedimensional imaging . J Spinal Cord Med 2008 ; 31 : 532-7
    • (2008) J Spinal Cord Med , vol.31 , pp. 532-7
    • Smith, H.E.1    Welsch, M.D.2    Sasso, R.C.3
  • 23
    • 33749519625 scopus 로고    scopus 로고
    • Radiation exposure during pedicle screw placement in adolescent idiopathic scoliosis: Is fluoroscopy safe?
    • DOI 10.1097/01.brs.0000238675.91612.2f, PII 0000763220061001000019
    • Ul Haque M , Shuffl ebarger HL , OBrien M , et al. Radiation exposure during pedicle screw placement in adolescent idiopathic scoliosis: is fl uoroscopy safe? Spine 2006 ; 31 : 2516-20 (Pubitemid 44527037)
    • (2006) Spine , vol.31 , Issue.21 , pp. 2516-2520
    • Ul Haque, M.1    Shufflebarger, H.L.2    O'Brien, M.3    Macagno, A.4
  • 24
    • 0034667336 scopus 로고    scopus 로고
    • Radiation exposure to the spine surgeon during fl uoroscopically assisted pedicle screw insertion
    • Rampersaud YR , Foley KT , Shen AC , et al. Radiation exposure to the spine surgeon during fl uoroscopically assisted pedicle screw insertion . Spine 2000 ; 25 : 2637-45
    • (2000) Spine , vol.25 , pp. 2637-45
    • Rampersaud, Y.R.1    Foley, K.T.2    Shen, A.C.3
  • 25
    • 0033562611 scopus 로고    scopus 로고
    • Radiation dose for pedicle screw insertion: Fluoroscopic method versus computer-assisted surgery
    • DOI 10.1097/00007632-199905150-00009
    • Slomczykowski M , Mini R , Schneeberger P , et al. Radiation dose for pedicle screw insertion: fl uoroscopic method versus computerassisted surgery . Spine 1999 ; 24 : 975-83 (Pubitemid 29222617)
    • (1999) Spine , vol.24 , Issue.10 , pp. 975-983
    • Slomczykowski, M.1    Roberto, M.2    Schneeberger, P.3    Ozdoba, C.4    Vock, P.5
  • 26
    • 0343526789 scopus 로고    scopus 로고
    • Radiation exposure during fluoroscopically assisted pedicle screw insertion in the lumbar spine
    • DOI 10.1097/00007632-200006150-00013
    • Jones DP , Robertson PA , Lunt B , et al. Radiation exposure during fl uoroscopically assisted pedicle screw insertion in the lumbar spine . Spine 2000 ; 25 : 1538-41 (Pubitemid 30418468)
    • (2000) Spine , vol.25 , Issue.12 , pp. 1538-1541
    • Gwynne Jones, D.P.1    Robertson, P.A.2    Lunt, B.3    Jackson, S.A.4
  • 27
    • 80455126500 scopus 로고    scopus 로고
    • O-arm.. Medtronic Navigation, Inc . Document Nr 2008 ; BI-700-00027-042 Rev: 1
    • O-arm. Dosimetry Report Summary . Medtronic Navigation, Inc . Document Nr 2008 ; BI-700-00027-042 Rev: 1
    • Dosimetry Report Summary
  • 28
    • 0030228293 scopus 로고    scopus 로고
    • Radiation skin injuries from fl uoroscopy
    • Shope B . Radiation skin injuries from fl uoroscopy . Radiographics 1996 ; 16 : 1195-9
    • (1996) Radiographics , vol.16 , pp. 1195-9
    • Shope, B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.