메뉴 건너뛰기




Volumn 76, Issue 3, 2013, Pages 170-174

Sensitivity and specificity of machine learning classifiers for glaucoma diagnosis using spectral domain oct and standard automated perimetry

Author keywords

Diagnostic techniques; Glaucoma diagnosis; Ophthalmological classification; Optical coherence instrumentation; Sensitivity and specificity; Tomography

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL INTELLIGENCE; CASE CONTROL STUDY; CHI SQUARE DISTRIBUTION; CROSS-SECTIONAL STUDY; EQUIPMENT; EVALUATION STUDY; FEMALE; GLAUCOMA; HUMAN; MALE; METHODOLOGY; MIDDLE AGED; OPTICAL COHERENCE TOMOGRAPHY; PERIMETRY; RECEIVER OPERATING CHARACTERISTIC; REFERENCE VALUE; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; VERY ELDERLY; VISUAL FIELD;

EID: 84883735736     PISSN: 00042749     EISSN: 16782925     Source Type: Journal    
DOI: 10.1590/S0004-27492013000300008     Document Type: Article
Times cited : (51)

References (29)
  • 2
    • 0036269833 scopus 로고    scopus 로고
    • The Ocular Hypertension Treatment Study: a randomized trial determines that topical ocular hypotensive medication delays or prevents the onset of primary open-angle glaucoma
    • Discussion 829-30
    • Kass MA, Heuer DK, Higginbotham EJ, Johnson CA, Keltner JL, Miller JP, et al. The Ocular Hypertension Treatment Study: a randomized trial determines that topical ocular hypotensive medication delays or prevents the onset of primary open-angle glaucoma. Arch Ophthalmol. 2002;120(6):701-13, discussion 829-30.
    • (2002) Arch Ophthalmol. , vol.120 , Issue.6 , pp. 701-713
    • Kass, M.A.1    Heuer, D.K.2    Higginbotham, E.J.3    Johnson, C.A.4    Keltner, J.L.5    Miller, J.P.6
  • 5
    • 0029068398 scopus 로고
    • Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography
    • Schuman JS, Hee MR, Puliafito CA, Wong C, Pedut-Kloizman T, Lin CP, et al. Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography. Arch Ophthalmol. 1995;113(5):586-96.
    • (1995) Arch Ophthalmol. , vol.113 , Issue.5 , pp. 586-596
    • Schuman, J.S.1    Hee, M.R.2    Puliafito, C.A.3    Wong, C.4    Pedut-Kloizman, T.5    Lin, C.P.6
  • 7
    • 0034943558 scopus 로고    scopus 로고
    • Discriminating between normal and glaucomatous eyes using the Heidelberg Retina Tomograph, GDx Nerve Fiber Analyzer, and Optical Coherence Tomograph
    • Zangwill LM, Bowd C, Berry CC, Williams J, Blumenthal EZ, Sánchez-Galeana CA, et al. Discriminating between normal and glaucomatous eyes using the Heidelberg Retina Tomograph, GDx Nerve Fiber Analyzer, and Optical Coherence Tomograph. Arch Ophthalmol. 2001;119(7):985-93.
    • (2001) Arch Ophthalmol. , vol.119 , Issue.7 , pp. 985-993
    • Zangwill, L.M.1    Bowd, C.2    Berry, C.C.3    Williams, J.4    Blumenthal, E.Z.5    Sánchez-Galeana, C.A.6
  • 8
    • 0037228869 scopus 로고    scopus 로고
    • Optical coherence tomography measurement of macular and nerve fiber layer thickness in normal and glaucomatous eyes
    • Guedes V, Schuman JS, Hertzmark E, Wollstein G, Correnti A, Mancini R, et al. Optical coherence tomography measurement of macular and nerve fiber layer thickness in normal and glaucomatous eyes. Ophthalmology. 2003;110(1):177-89.
    • (2003) Ophthalmology. , vol.110 , Issue.1 , pp. 177-189
    • Guedes, V.1    Schuman, J.S.2    Hertzmark, E.3    Wollstein, G.4    Correnti, A.5    Mancini, R.6
  • 9
    • 70649094280 scopus 로고    scopus 로고
    • Sensitivity and specificity of time-domain versus spectral-domain optical coherence tomography in diagnosing early to moderate glaucoma
    • Chang RT, Knight OJ, Feuer WJ, Budenz DL. Sensitivity and specificity of time-domain versus spectral-domain optical coherence tomography in diagnosing early to moderate glaucoma. Ophthalmology. 2009;116(12):2294-9.
    • (2009) Ophthalmology. , vol.116 , Issue.12 , pp. 2294-2299
    • Chang, R.T.1    Knight, O.J.2    Feuer, W.J.3    Budenz, D.L.4
  • 10
    • 77449084640 scopus 로고    scopus 로고
    • Comparison of Cirrus OCT and Stratus OCT on the ability to detect localized retinal nerve fiber layer defects in preperimetric glaucoma
    • Jeoung JK, Park KH. Comparison of Cirrus OCT and Stratus OCT on the ability to detect localized retinal nerve fiber layer defects in preperimetric glaucoma. Invest Ophthalmol Vis Sci. 2010;51(2):938-45.
    • (2010) Invest Ophthalmol Vis Sci. , vol.51 , Issue.2 , pp. 938-945
    • Jeoung, J.K.1    Park, K.H.2
  • 11
    • 73349089982 scopus 로고    scopus 로고
    • Comparison of glaucoma diagnostic Capabilities of Cirrus HD and Stratus optical coherence tomography
    • Park SB, Sung KR, Kang SY, Kim KR, Kook MS. Comparison of glaucoma diagnostic Capabilities of Cirrus HD and Stratus optical coherence tomography. Arch Ophthalmol. 2009;127(12):1603-9.
    • (2009) Arch Ophthalmol. , vol.127 , Issue.12 , pp. 1603-1609
    • Park, S.B.1    Sung, K.R.2    Kang, S.Y.3    Kim, K.R.4    Kook, M.S.5
  • 12
    • 75749124329 scopus 로고    scopus 로고
    • Cirrus high-definition optical coherence tomography compared with Stratus optical coherence tomography in glaucoma diagnosis
    • Moreno-Montañés J, Olmo N, Alvarez A, García N, Zarranz-Ventura J. Cirrus high-definition optical coherence tomography compared with Stratus optical coherence tomography in glaucoma diagnosis. Invest Ophthalmol Vis Sci. 2010;51(1):335-43.
    • (2010) Invest Ophthalmol Vis Sci. , vol.51 , Issue.1 , pp. 335-343
    • Moreno-Montañés, J.1    Olmo, N.2    Alvarez, A.3    García, N.4    Zarranz-Ventura, J.5
  • 13
    • 67649311848 scopus 로고    scopus 로고
    • Comparison of retinal nerve fiber layer measurements using time domain and spectral domain optical coherent tomography
    • Knight OJ, Chang RT, Feuer WJ, Budenz DL. Comparison of retinal nerve fiber layer measurements using time domain and spectral domain optical coherent tomography. Ophthalmology. 2009;116(7):1271-7.
    • (2009) Ophthalmology. , vol.116 , Issue.7 , pp. 1271-1277
    • Knight, O.J.1    Chang, R.T.2    Feuer, W.J.3    Budenz, D.L.4
  • 14
    • 33846321243 scopus 로고    scopus 로고
    • Trained artificial neural network for glaucoma diagnosis using visual field data: a comparison with conventional algorithms
    • Bizios D, Heijl A, Bengtsson B. Trained artificial neural network for glaucoma diagnosis using visual field data: a comparison with conventional algorithms. J Glaucoma. 2007; 16(1):20-8.
    • (2007) J Glaucoma. , vol.16 , Issue.1 , pp. 20-28
    • Bizios, D.1    Heijl, A.2    Bengtsson, B.3
  • 16
    • 18244383805 scopus 로고    scopus 로고
    • Relevance vector machine and support vector machine classifier analysis of scanning laser polarimetry retinal nerve fiber layer measurements
    • Bowd C, Medeiros FA, Zhang Z, Zangwill LM, Hao J, Lee TW, el al. Relevance vector machine and support vector machine classifier analysis of scanning laser polarimetry retinal nerve fiber layer measurements. Invest Ophthalmol Vis Sci. 2005;46(4):1322-9.
    • (2005) Invest Ophthalmol Vis Sci. , vol.46 , Issue.4 , pp. 1322-1329
    • Bowd, C.1    Medeiros, F.A.2    Zhang, Z.3    Zangwill, L.M.4    Hao, J.5    Lee, T.W.6    el, al.7
  • 17
    • 76149109733 scopus 로고    scopus 로고
    • Machine learning classifiers for glaucoma diagnosis based on classification of retinal nerve fibre layer thickness parameters measured by Stratus OCT
    • Bizios D, Heijl A, Hougaard JL, Bengtsson B. Machine learning classifiers for glaucoma diagnosis based on classification of retinal nerve fibre layer thickness parameters measured by Stratus OCT. Acta Ophthalmol. 2010;88(1):44-52.
    • (2010) Acta Ophthalmol. , vol.88 , Issue.1 , pp. 44-52
    • Bizios, D.1    Heijl, A.2    Hougaard, J.L.3    Bengtsson, B.4
  • 19
    • 41949089226 scopus 로고    scopus 로고
    • Bayesian machine learning classifiers for combining structural and functional measurements to classify healthy and glaucomatous eyes
    • Bowd C, Hao J, Tavares IM, Medeiros FA, Zangwill LM, Lee TW, et al. Bayesian machine learning classifiers for combining structural and functional measurements to classify healthy and glaucomatous eyes. Invest Ophthalmol Vis Sci. 2008;49(3):945-53.
    • (2008) Invest Ophthalmol Vis Sci. , vol.49 , Issue.3 , pp. 945-953
    • Bowd, C.1    Hao, J.2    Tavares, I.M.3    Medeiros, F.A.4    Zangwill, L.M.5    Lee, T.W.6
  • 20
    • 38849145748 scopus 로고    scopus 로고
    • Comparison of classifiers applied to confocal scanning laser ophthalmoscopy data
    • Adler W, Peters A, Lausen B. Comparison of classifiers applied to confocal scanning laser ophthalmoscopy data. Methods Inf Med. 2008;47(1):38-46.
    • (2008) Methods Inf Med. , vol.47 , Issue.1 , pp. 38-46
    • Adler, W.1    Peters, A.2    Lausen, B.3
  • 21
    • 38549104188 scopus 로고    scopus 로고
    • Assessing visual field clustering schemes using machine learning classifiers in standard perimetry
    • Boden C, Chan K, Sample PA, Hao J, Lee TW, Zangwill LM, et al. Assessing visual field clustering schemes using machine learning classifiers in standard perimetry. Invest Ophthalmol Vis Sci. 2007;48(12):5582-90.
    • (2007) Invest Ophthalmol Vis Sci. , vol.48 , Issue.12 , pp. 5582-5590
    • Boden, C.1    Chan, K.2    Sample, P.A.3    Hao, J.4    Lee, T.W.5    Zangwill, L.M.6
  • 22
    • 33746459739 scopus 로고    scopus 로고
    • Improving glaucoma diagnosis by the combination of perimetry and HRT measurements
    • Mardin CY, Peters A, Horn F, Jünemann AG, Lausen B. Improving glaucoma diagnosis by the combination of perimetry and HRT measurements. J Glaucoma. 2006; 15(4):299-305.
    • (2006) J Glaucoma. , vol.15 , Issue.4 , pp. 299-305
    • Mardin, C.Y.1    Peters, A.2    Horn, F.3    Jünemann, A.G.4    Lausen, B.5
  • 23
    • 33644673457 scopus 로고    scopus 로고
    • Development and comparison of automated classifiers for glaucoma diagnosis using Stratus optical coherence tomography
    • Huang ML, Chen HY. Development and comparison of automated classifiers for glaucoma diagnosis using Stratus optical coherence tomography. Invest Ophthalmol Vis Sci. 2005;46(11):4121-9.
    • (2005) Invest Ophthalmol Vis Sci. , vol.46 , Issue.11 , pp. 4121-4129
    • Huang, M.L.1    Chen, H.Y.2
  • 24
    • 4344713313 scopus 로고    scopus 로고
    • Heidelberg retina tomograph measurements of the optic disc and parapapillary retina for detecting glaucoma analyzed by machine learning classifiers
    • Zangwill LM, Chan K, Bowd C, Hao J, Lee TW, Weinreb RN, et al. Heidelberg retina tomograph measurements of the optic disc and parapapillary retina for detecting glaucoma analyzed by machine learning classifiers. Invest Ophthalmol Vis Sci. 2004; 45(9):3144-51.
    • (2004) Invest Ophthalmol Vis Sci. , vol.45 , Issue.9 , pp. 3144-3151
    • Zangwill, L.M.1    Chan, K.2    Bowd, C.3    Hao, J.4    Lee, T.W.5    Weinreb, R.N.6
  • 25
    • 84883693397 scopus 로고    scopus 로고
    • Sensitivity and specificity of machine learning classifiers and spectral domain OCT for the diagnosis of glaucoma
    • 2012 Jun 15:0. [Epub ahead of print]
    • Vidotti VG, Costa VP, Silva FR, Resende GM, Cremasco F, Dias M, et al. Sensitivity and specificity of machine learning classifiers and spectral domain OCT for the diagnosis of glaucoma. Eur J Ophthalmol. 2012 Jun 15:0. [Epub ahead of print]
    • Eur J Ophthalmol
    • Vidotti, V.G.1    Costa, V.P.2    Silva, F.R.3    Resende, G.M.4    Cremasco, F.5    Dias, M.6
  • 26
    • 0035036066 scopus 로고    scopus 로고
    • Discrimination between normal and glaucomatous eyes with visual field and scanning laser polarimetry measurements
    • Erratum in Br J Ophthalmol. 2002;86(6):707
    • Lauande-Pimentel R, Carvalho RA, Oliveira HC, Gonçalves DC, Silva LM, Costa VP. Discrimination between normal and glaucomatous eyes with visual field and scanning laser polarimetry measurements. Br J Ophthalmology. 2001;85(5):586-91. Erratum in Br J Ophthalmol. 2002;86(6):707.
    • (2001) Br J Ophthalmology. , vol.85 , Issue.5 , pp. 586-591
    • Lauande-Pimentel, R.1    Carvalho, R.A.2    Oliveira, H.C.3    Gonçalves, D.C.4    Silva, L.M.5    Costa, V.P.6
  • 27
    • 33747873588 scopus 로고    scopus 로고
    • Combining structural and functional testing for detection of glaucoma
    • Comment in Ophthalmology. 2007;114(7):1414. Ophthalmology. 2006;113(9):1479-80
    • Shah NN, Bowd C, Medeiros FA, Weinreb RN, Sample PA, Hoffmann EM, et al. Combining structural and functional testing for detection of glaucoma. Ophthalmology. 2006;113(9):1593-602. Comment in Ophthalmology. 2007;114(7):1414. Ophthalmology. 2006;113(9):1479-80.
    • (2006) Ophthalmology. , vol.113 , Issue.9 , pp. 1593-1602
    • Shah, N.N.1    Bowd, C.2    Medeiros, F.A.3    Weinreb, R.N.4    Sample, P.A.5    Hoffmann, E.M.6
  • 28
    • 79952048463 scopus 로고    scopus 로고
    • Combining functional and structural tests improves the diagnostic accuracy of relevance vector machine classifiers
    • Racette L, Chiou CY, Hao J, Bowd C, Goldbaum MH, Zangwill LM, et al. Combining functional and structural tests improves the diagnostic accuracy of relevance vector machine classifiers. J Glaucoma. 2010;19(3):167-75.
    • (2010) J Glaucoma. , vol.19 , Issue.3 , pp. 167-175
    • Racette, L.1    Chiou, C.Y.2    Hao, J.3    Bowd, C.4    Goldbaum, M.H.5    Zangwill, L.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.