메뉴 건너뛰기




Volumn 51, Issue 1, 2010, Pages 335-343

Cirrus high-definition optical coherence tomography compared with stratus optical coherence tomography in glaucoma diagnosis

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; FEMALE; GLAUCOMA; HUMAN; IMAGE QUALITY; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; OPTICAL COHERENCE TOMOGRAPHY; OPTICAL RESOLUTION; PRIORITY JOURNAL; PROSPECTIVE STUDY; RECEIVER OPERATING CHARACTERISTIC; RETINA NERVE CELL; SENSITIVITY AND SPECIFICITY; AREA UNDER THE CURVE; COMPARATIVE STUDY; GONIOSCOPY; INSTRUMENTATION; INTRAOCULAR PRESSURE; METHODOLOGY; MIDDLE AGED; NERVE FIBER; OPEN ANGLE GLAUCOMA; OPTIC DISK; OPTIC NERVE DISEASE; PATHOLOGY; RETINA GANGLION CELL; STATISTICAL MODEL; VISUAL DISORDER; VISUAL FIELD;

EID: 75749124329     PISSN: 01460404     EISSN: 15525783     Source Type: Journal    
DOI: 10.1167/iovs.08-2988     Document Type: Article
Times cited : (73)

References (34)
  • 1
    • 0026254046 scopus 로고
    • Optical coherence tomography
    • Huang D, Swanson EA, Lin CP, et al. Optical coherence tomography. Science. 1991;254:1178-1181.
    • (1991) Science , vol.254 , pp. 1178-1181
    • Huang, D.1    Swanson, E.A.2    Lin, C.P.3
  • 3
    • 34748820739 scopus 로고    scopus 로고
    • American Academy of Ophthalmology; Ophthalmic Technology Assessment Committee Glaucoma Panel. Optic nerve head and retinal nerve fiber layer analysis: A report by the American Academy of Ophthalmology
    • Lin SC, Singh K, Jampel HD, et al. American Academy of Ophthalmology; Ophthalmic Technology Assessment Committee Glaucoma Panel. Optic nerve head and retinal nerve fiber layer analysis: a report by the American Academy of Ophthalmology. Ophthalmology. 2007;114:1937-1949.
    • (2007) Ophthalmology , vol.114 , pp. 1937-1949
    • Lin, S.C.1    Singh, K.2    Jampel, H.D.3
  • 5
    • 29544441195 scopus 로고    scopus 로고
    • Categorizing the stage of glaucoma from pre-diagnosis to end-stage disease
    • Mills RP, Budenz DL, Lee PP, et al. Categorizing the stage of glaucoma from pre-diagnosis to end-stage disease. Am J Ophthalmol. 2006;141:24-30.
    • (2006) Am J Ophthalmol , vol.141 , pp. 24-30
    • Mills, R.P.1    Budenz, D.L.2    Lee, P.P.3
  • 6
    • 0020524559 scopus 로고
    • A method of comparing the areas under receiver operating characteristic curves derived from the same cases
    • Hanley JA, McNeil BJ. A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology. 1983;148:839-843.
    • (1983) Radiology , vol.148 , pp. 839-843
    • Hanley, J.A.1    McNeil, B.J.2
  • 7
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 8
    • 84973587732 scopus 로고
    • A coefficient of agreement for nominal scales
    • Cohen J. A coefficient of agreement for nominal scales. Educ Psychol Meas. 1960;20:37-46.
    • (1960) Educ Psychol Meas , vol.20 , pp. 37-46
    • Cohen, J.1
  • 9
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159-174.
    • (1977) Biometrics , vol.33 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 10
    • 40049096480 scopus 로고    scopus 로고
    • New developments in optical coherence tomography for glaucoma
    • Chang R, Budenz DL. New developments in optical coherence tomography for glaucoma. Curr Opin Ophthalmol. 2008;19:127-135.
    • (2008) Curr Opin Ophthalmol , vol.19 , pp. 127-135
    • Chang, R.1    Budenz, D.L.2
  • 11
    • 0024402107 scopus 로고
    • Retinal ganglion cell atrophy correlated with automated perimetry in human eyes with glaucoma
    • Quigley HA, Dunkelberger GR, Green WR. Retinal ganglion cell atrophy correlated with automated perimetry in human eyes with glaucoma. Am J Ophthalmol. 1989;107:453-464.
    • (1989) Am J Ophthalmol , vol.107 , pp. 453-464
    • Quigley, H.A.1    Dunkelberger, G.R.2    Green, W.R.3
  • 12
    • 0026099038 scopus 로고
    • Clinically detectable nerve fiber layer atrophy precedes the onset of glaucomatous field loss
    • Sommer A, Katz J, Quigley HA, et al. Clinically detectable nerve fiber layer atrophy precedes the onset of glaucomatous field loss. Arch Ophthalmol. 1991;199:77-81.
    • (1991) Arch Ophthalmol , vol.199 , pp. 77-81
    • Sommer, A.1    Katz, J.2    Quigley, H.A.3
  • 13
    • 0034013821 scopus 로고    scopus 로고
    • Number of ganglion cells in glaucoma eyes compared with threshold visual field tests in the same persons. Invest
    • Kerrigan-Baumrind LA, Quigley HA, Pease ME, et al. Number of ganglion cells in glaucoma eyes compared with threshold visual field tests in the same persons. Invest. Ophthalmol Vis Sci. 2000;41:741-748.
    • (2000) Ophthalmol Vis Sci , vol.41 , pp. 741-748
    • Kerrigan-Baumrind, L.A.1    Quigley, H.A.2    Pease, M.E.3
  • 14
    • 33745416172 scopus 로고    scopus 로고
    • Dublin, CA: Carl Zeiss Meditec. 2002: PN 55648 REV. A 4/03, 1-1-1-3
    • Stratus OCT User Manual. Dublin, CA: Carl Zeiss Meditec. 2002: PN 55648 REV. A 4/03, 1-1-1-3.
    • Stratus OCT User Manual
  • 15
    • 33748103920 scopus 로고    scopus 로고
    • Discrimination between glaucomatous and nonglaucomatous eyes using quantitative imaging devices and subjective optic nerve head assessment
    • DeLeón-Ortega JE, Arthur SN, McGwin G, et al. Discrimination between glaucomatous and nonglaucomatous eyes using quantitative imaging devices and subjective optic nerve head assessment. Invest Ophthalmol Vis Sci. 2006;47:3374-3380.
    • (2006) Invest Ophthalmol Vis Sci , vol.47 , pp. 3374-3380
    • DeLeón-Ortega, J.E.1    Arthur, S.N.2    McGwin, G.3
  • 16
    • 34347338731 scopus 로고    scopus 로고
    • Retinal nerve fibre thickness measured with optical coherence tomography accurately detects confirmed glaucomatous damage
    • Hood DC, Harizman N, Kanadani FN, et al. Retinal nerve fibre thickness measured with optical coherence tomography accurately detects confirmed glaucomatous damage. Br J Ophthalmol. 2007;91:905-907.
    • (2007) Br J Ophthalmol , vol.91 , pp. 905-907
    • Hood, D.C.1    Harizman, N.2    Kanadani, F.N.3
  • 17
    • 11344261778 scopus 로고    scopus 로고
    • Sensitivity and specificity of the StratusOCT for perimetric glaucoma
    • Budenz DL, Michael A, Chang RT, et al. Sensitivity and specificity of the StratusOCT for perimetric glaucoma. Ophthalmology. 2005;112:3-9.
    • (2005) Ophthalmology , vol.112 , pp. 3-9
    • Budenz, D.L.1    Michael, A.2    Chang, R.T.3
  • 18
    • 33846313640 scopus 로고    scopus 로고
    • Usefulness of optical coherence tomography parameters of the optic disc and the retinal nerve fiber layer to differentiate glaucomatous, ocular hypertensive, and normal eyes
    • Anton A, Moreno-Montañes J, Blázquez F, et al. Usefulness of optical coherence tomography parameters of the optic disc and the retinal nerve fiber layer to differentiate glaucomatous, ocular hypertensive, and normal eyes. J Glaucoma. 2007;16:1-8.
    • (2007) J Glaucoma , vol.16 , pp. 1-8
    • Anton, A.1    Moreno-Montañes, J.2    Blázquez, F.3
  • 19
    • 53449092950 scopus 로고    scopus 로고
    • Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema
    • Forooghian F, Cukras C, Meyerle CB, et al. Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema. Invest Ophthalmol Vis Sci. 2008;49:4290-4296.
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , pp. 4290-4296
    • Forooghian, F.1    Cukras, C.2    Meyerle, C.B.3
  • 20
    • 43949121072 scopus 로고    scopus 로고
    • Spectral-domain Cirrus highdefinition optical coherence tomography is better than time-domain Stratus optical coherence tomography for evaluation of macular pathologic features in uveitis
    • Gupta V, Gupta P, Singh R, et al. Spectral-domain Cirrus highdefinition optical coherence tomography is better than time-domain Stratus optical coherence tomography for evaluation of macular pathologic features in uveitis. Am J Ophthalmol. 2008;145:1018-1022.
    • (2008) Am J Ophthalmol , vol.145 , pp. 1018-1022
    • Gupta, V.1    Gupta, P.2    Singh, R.3
  • 21
    • 38949189334 scopus 로고    scopus 로고
    • Automatic segmentation in three-dimensional analysis of fibrovascular pigment epithelial detachment using high-definition optical coherence tomography
    • Ahlers C, Simader C, Geitzenauer W, et al. Automatic segmentation in three-dimensional analysis of fibrovascular pigment epithelial detachment using high-definition optical coherence tomography. Br J Ophthalmol. 2008;92:197-203.
    • (2008) Br J Ophthalmol , vol.92 , pp. 197-203
    • Ahlers, C.1    Simader, C.2    Geitzenauer, W.3
  • 22
    • 34547201948 scopus 로고    scopus 로고
    • Factors associated with variability in retinal nerve fiber layer thickness measurements obtained by optical coherence tomography
    • Wu Z, Vazeen M, Varma R, et al. Factors associated with variability in retinal nerve fiber layer thickness measurements obtained by optical coherence tomography. Ophthalmology. 2007;114:1505-1512.
    • (2007) Ophthalmology , vol.114 , pp. 1505-1512
    • Wu, Z.1    Vazeen, M.2    Varma, R.3
  • 23
    • 36749103793 scopus 로고    scopus 로고
    • Effect of pupillary dilatation on glaucoma tomography assessments using optical coherence
    • Smith M, Frost A, Graham CM, et al. Effect of pupillary dilatation on glaucoma tomography assessments using optical coherence. Br J Ophthalmol. 2007;91:1686-1690.
    • (2007) Br J Ophthalmol , vol.91 , pp. 1686-1690
    • Smith, M.1    Frost, A.2    Graham, C.M.3
  • 24
    • 33746426603 scopus 로고    scopus 로고
    • Influence of pupil size and cataract on retinal nerve fiber layer thickness measurements by Stratus OCT
    • Savini G, Zanini M, Barboni P. Influence of pupil size and cataract on retinal nerve fiber layer thickness measurements by Stratus OCT. J Glaucoma. 2006;15:336-340.
    • (2006) J Glaucoma , vol.15 , pp. 336-340
    • Savini, G.1    Zanini, M.2    Barboni, P.3
  • 25
    • 31544437689 scopus 로고    scopus 로고
    • A new quality assessment parameter for optical coherence tomography
    • Stein DM, Ishikawa H, Hariprasad R, et al. A new quality assessment parameter for optical coherence tomography. Br J Ophthalmol. 2006;90:186-190.
    • (2006) Br J Ophthalmol , vol.90 , pp. 186-190
    • Stein, D.M.1    Ishikawa, H.2    Hariprasad, R.3
  • 26
    • 34247191582 scopus 로고    scopus 로고
    • A comparison of structural measurements using 2 Stratus optical coherence tomography instruments
    • Sehi M, Guaqueta DC, Feuer WJ, et al. A comparison of structural measurements using 2 Stratus optical coherence tomography instruments. J Glaucoma. 2007;16:287-292.
    • (2007) J Glaucoma , vol.16 , pp. 287-292
    • Sehi, M.1    Guaqueta, D.C.2    Feuer, W.J.3
  • 27
    • 33749008516 scopus 로고    scopus 로고
    • Comparação entre o polarímetro de varredura a laser, a tomografia de coerência óptica 1 e o Stratus-OCT na detecção da perda axonal da atrofia em banda do nervo óptico
    • Leal BC, Moura FC, Monteiro ML. Comparação entre o polarímetro de varredura a laser, a tomografia de coerência óptica 1 e o Stratus-OCT na detecção da perda axonal da atrofia em banda do nervo óptico. Arq Bras Oftalmol. 2006;69:531-537.
    • (2006) Arq Bras Oftalmol , vol.69 , pp. 531-537
    • Leal, B.C.1    Moura, F.C.2    Monteiro, M.L.3
  • 28
    • 18244389991 scopus 로고    scopus 로고
    • Comparability of retinal nerve fiber layer thickness measurements of optical coherence tomography instruments
    • Bourne RR, Medeiros FA, Bowd C, et al. Comparability of retinal nerve fiber layer thickness measurements of optical coherence tomography instruments. Invest Ophthalmol Vis Sci. 2005;46:1280-1285.
    • (2005) Invest Ophthalmol Vis Sci , vol.46 , pp. 1280-1285
    • Bourne, R.R.1    Medeiros, F.A.2    Bowd, C.3
  • 29
    • 0037375923 scopus 로고    scopus 로고
    • Evaluation of the glaucomatous damage on retinal nerve fiber layer thickness measured by optical coherence tomography
    • Kanamori A, Nakamura M, Escano MF, et al. Evaluation of the glaucomatous damage on retinal nerve fiber layer thickness measured by optical coherence tomography. Am J Ophthalmol. 2003;135:513-520.
    • (2003) Am J Ophthalmol , vol.135 , pp. 513-520
    • Kanamori, A.1    Nakamura, M.2    Escano, M.F.3
  • 30
    • 9144271384 scopus 로고    scopus 로고
    • Evaluation of scanning resolution on retinal nerve fiber layer measurement using optical coherence tomography in normal and glaucomatous eyes
    • Leung CK, Yung WH, Ng AC, et al. Evaluation of scanning resolution on retinal nerve fiber layer measurement using optical coherence tomography in normal and glaucomatous eyes. J Glaucoma. 2004;13:479-485.
    • (2004) J Glaucoma , vol.13 , pp. 479-485
    • Leung, C.K.1    Yung, W.H.2    Ng, A.C.3
  • 31
    • 17844402965 scopus 로고    scopus 로고
    • Refining clinical diagnosis with likelihood ratios
    • Grimes DA, Schulz KF. Refining clinical diagnosis with likelihood ratios. Lancet. 2005;365:1500-1505.
    • (2005) Lancet , vol.365 , pp. 1500-1505
    • Grimes, D.A.1    Schulz, K.F.2
  • 32
    • 36549057039 scopus 로고    scopus 로고
    • Diagnostic capability of optical coherence tomography (Stratus OCT 3) in early glaucoma
    • Parikh RS, Parikh S, Sekhar GC, et al. Diagnostic capability of optical coherence tomography (Stratus OCT 3) in early glaucoma. Ophthalmology. 2007;114:2238-2243.
    • (2007) Ophthalmology , vol.114 , pp. 2238-2243
    • Parikh, R.S.1    Parikh, S.2    Sekhar, G.C.3
  • 33
    • 34548713022 scopus 로고    scopus 로고
    • Comparison of diagnostic accuracy of Heidelberg Retina Tomograph II and Heidelberg Retina Tomograph 3 to discriminate glaucomatous and nonglaucomatous eyes
    • De León-Ortega JE, Sakata LM, Monheit BE, et al. Comparison of diagnostic accuracy of Heidelberg Retina Tomograph II and Heidelberg Retina Tomograph 3 to discriminate glaucomatous and nonglaucomatous eyes. Am J Ophthalmol. 2007;144:525-532.
    • (2007) Am J Ophthalmol , vol.144 , pp. 525-532
    • De León-Ortega, J.E.1    Sakata, L.M.2    Monheit, B.E.3
  • 34
    • 33846932611 scopus 로고    scopus 로고
    • The effects of study design and spectrum bias on the evaluation of diagnostic accuracy of confocal scanning laser ophthalmoscopy in glaucoma
    • Medeiros FA, Ng D, Zangwill LM, et al. The effects of study design and spectrum bias on the evaluation of diagnostic accuracy of confocal scanning laser ophthalmoscopy in glaucoma. Invest Ophthalmol Vis Sci. 2007;48:214-222.
    • (2007) Invest Ophthalmol Vis Sci , vol.48 , pp. 214-222
    • Medeiros, F.A.1    Ng, D.2    Zangwill, L.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.