메뉴 건너뛰기




Volumn 18, Issue 5, 2013, Pages 245-250

Central venous oxygen saturation: Analysis, clinical use and effects on mortality

Author keywords

Advanced patient assessment; Clinical guidelines; Haemodynamic monitoring; Intensive care nursing; Resuscitation; Sepsis and shock

Indexed keywords

ADVANCED PATIENT ASSESSMENT; ARTICLE; CLINICAL GUIDELINES; CRITICAL ILLNESS; HAEMODYNAMIC MONITORING; HEART OUTPUT; HUMAN; INTENSIVE CARE; INTENSIVE CARE NURSING; MORTALITY; NURSE ATTITUDE; NURSING; OXIMETRY; OXYGEN CONSUMPTION; RESUSCITATION; SEPSIS AND SHOCK;

EID: 84882887001     PISSN: 13621017     EISSN: 14785153     Source Type: Journal    
DOI: 10.1111/nicc.12028     Document Type: Article
Times cited : (12)

References (28)
  • 1
    • 33847276628 scopus 로고    scopus 로고
    • Incidence of low central venous oxygen saturation during unplanned admissions in a multidisciplinary intensive care unit: an observational study
    • Bracht H, Hänggi M, Jeker B, Wegmüller N, Porta F, Tüller D, Takala J, Jakob SM. (2007). Incidence of low central venous oxygen saturation during unplanned admissions in a multidisciplinary intensive care unit: an observational study. Critical Care; 11: 1-8.
    • (2007) Critical Care , vol.11 , pp. 1-8
    • Bracht, H.1    Hänggi, M.2    Jeker, B.3    Wegmüller, N.4    Porta, F.5    Tüller, D.6    Takala, J.7    Jakob, S.M.8
  • 2
    • 10444279213 scopus 로고    scopus 로고
    • Lack of equivalence between central and mixed venous oxygen saturation
    • Chawla LS, Zia H, Gutierrez G, Katz NM, Seneff MG, Shah M. (2004). Lack of equivalence between central and mixed venous oxygen saturation. Chest; 126: 1891-1896.
    • (2004) Chest , vol.126 , pp. 1891-1896
    • Chawla, L.S.1    Zia, H.2    Gutierrez, G.3    Katz, N.M.4    Seneff, M.G.5    Shah, M.6
  • 3
    • 77954745367 scopus 로고    scopus 로고
    • Femoral-based central venous oxygen saturation is not a reliable substitute for subclavian/internal-jugular based central venous oxygen saturation in patients who are critically ill
    • Davidson DL, Chawla LS, Selassie L, Jones EM, McHone KC, Vota AR, Junker C, Sateri S, Seneff MG. (2010). Femoral-based central venous oxygen saturation is not a reliable substitute for subclavian/internal-jugular based central venous oxygen saturation in patients who are critically ill. Chest; 138: 76-83.
    • (2010) Chest , vol.138 , pp. 76-83
    • Davidson, D.L.1    Chawla, L.S.2    Selassie, L.3    Jones, E.M.4    McHone, K.C.5    Vota, A.R.6    Junker, C.7    Sateri, S.8    Seneff, M.G.9
  • 5
    • 23044442783 scopus 로고    scopus 로고
    • Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions
    • Dueck MH, Klimek M, Appenrodt S, Weigand C, Boerner U. (2005). Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions. Anesthesiology; 103: 249-257.
    • (2005) Anesthesiology , vol.103 , pp. 249-257
    • Dueck, M.H.1    Klimek, M.2    Appenrodt, S.3    Weigand, C.4    Boerner, U.5
  • 6
    • 64149104953 scopus 로고    scopus 로고
    • Comparison of central venous oxygen saturation and mixed venous oxygen saturation during liver transplantation
    • El Masry A, Mukhtar AM, El Sherbeny AM, Fathy M, El-Meteini M. (2009). Comparison of central venous oxygen saturation and mixed venous oxygen saturation during liver transplantation. Anaesthesia; 64: 378-382.
    • (2009) Anaesthesia , vol.64 , pp. 378-382
    • El Masry, A.1    Mukhtar, A.M.2    El Sherbeny, A.M.3    Fathy, M.4    El-Meteini, M.5
  • 7
    • 84865118824 scopus 로고    scopus 로고
    • Central venous oxygen saturation in septic shock: a marker of cardiac output, microvascular shunting and/or dysoxia?
    • Haase N, Perner A. (2011). Central venous oxygen saturation in septic shock: a marker of cardiac output, microvascular shunting and/or dysoxia? Critical Care; 15: 184-186.
    • (2011) Critical Care , vol.15 , pp. 184-186
    • Haase, N.1    Perner, A.2
  • 9
  • 10
    • 68049112610 scopus 로고    scopus 로고
    • Venous oxygen saturation and lactate gradient from superior vena cava to pulmonary artery in patients with septic shock
    • Kopterides P, Bonovas S, Mavrou I, Kostadima E, Zakynthinos E, Armaganidis A. (2009). Venous oxygen saturation and lactate gradient from superior vena cava to pulmonary artery in patients with septic shock. Shock; 31: 561-567.
    • (2009) Shock , vol.31 , pp. 561-567
    • Kopterides, P.1    Bonovas, S.2    Mavrou, I.3    Kostadima, E.4    Zakynthinos, E.5    Armaganidis, A.6
  • 14
    • 77951175618 scopus 로고    scopus 로고
    • Optimising hemodynamic support in septic shock using central venous and mixed venous oxygen saturation
    • Maddirala S, Khan A. (2010). Optimising hemodynamic support in septic shock using central venous and mixed venous oxygen saturation. Critical Care Clinics; 26: 323-333.
    • (2010) Critical Care Clinics , vol.26 , pp. 323-333
    • Maddirala, S.1    Khan, A.2
  • 16
    • 78751649210 scopus 로고    scopus 로고
    • Low and supranormal central venous oxygen saturation and markers of tissue hypoxia in cardiac surgery patients: a prospective observational study
    • Perz S, Uhlig T, Kohl M, Bredle DL, Reinhart K, Bauer M, Kortgen A. (2011). Low and supranormal central venous oxygen saturation and markers of tissue hypoxia in cardiac surgery patients: a prospective observational study. Intensive Care Medicine; 37: 52-59.
    • (2011) Intensive Care Medicine , vol.37 , pp. 52-59
    • Perz, S.1    Uhlig, T.2    Kohl, M.3    Bredle, D.L.4    Reinhart, K.5    Bauer, M.6    Kortgen, A.7
  • 19
    • 4143058000 scopus 로고    scopus 로고
    • Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill
    • Reinhart K, Kuhn H-J, Hartog C, Bredle DL. (2004). Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill. Intensive Care Medicine; 30: 1572-1578.
    • (2004) Intensive Care Medicine , vol.30 , pp. 1572-1578
    • Reinhart, K.1    Kuhn, H.-J.2    Hartog, C.3    Bredle, D.L.4
  • 21
    • 0034977389 scopus 로고    scopus 로고
    • Central venous oxygen saturation monitoring in the critically ill patient
    • Rivers EP, Ander DS, Powell D. (2001b). Central venous oxygen saturation monitoring in the critically ill patient. Current Opinion in Critical Care; 7: 204-221.
    • (2001) Current Opinion in Critical Care , vol.7 , pp. 204-221
    • Rivers, E.P.1    Ander, D.S.2    Powell, D.3
  • 22
    • 37549020378 scopus 로고    scopus 로고
    • International guidelines for management of severe sepsis and septic shock
    • Surviving Sepsis Campaign
    • Surviving Sepsis Campaign. (2008). International guidelines for management of severe sepsis and septic shock. Critical Care Medicine; 36: 296-327.
    • (2008) Critical Care Medicine , vol.36 , pp. 296-327
  • 23
    • 84882846479 scopus 로고    scopus 로고
    • Society of Critical Care Medicine.Surviving Sepsis Bundle: Bundle Element 5, internet]. Surviving Sepsis Campaign.(accessed 04/09/12).
    • Society of Critical Care Medicine. 2012. Surviving Sepsis Bundle: Bundle Element 5, [internet]. Surviving Sepsis Campaign. http://www.survivingsepsis.org/Bundles/Individual_Changes/Pages/maintaincentralsvo2.aspx (accessed 04/09/12).
    • (2012)
  • 25
    • 79960684724 scopus 로고    scopus 로고
    • High central venous oxygen saturation in the latter stages of septic shock is associated with increased mortality
    • Textoris J, Fouché L, Wiramus S, Antonini F, Tho S, Martin C, Leone M. (2011). "High central venous oxygen saturation in the latter stages of septic shock is associated with increased mortality", Critical Care, 15, 176-182.
    • (2011) Critical Care , vol.15 , pp. 176-182
    • Textoris, J.1    Fouché, L.2    Wiramus, S.3    Antonini, F.4    Tho, S.5    Martin, C.6    Leone, M.7
  • 26
    • 33747601081 scopus 로고    scopus 로고
    • Mixed venous oxygen saturation cannot be estimated by central venous oxygen saturation in septic shock
    • Varpula M, Karlsson S, Ruokonen E, Pettila V. (2006). Mixed venous oxygen saturation cannot be estimated by central venous oxygen saturation in septic shock. Intensive Care Medicine; 32: 1336-1343.
    • (2006) Intensive Care Medicine , vol.32 , pp. 1336-1343
    • Varpula, M.1    Karlsson, S.2    Ruokonen, E.3    Pettila, V.4
  • 27
    • 0038137438 scopus 로고    scopus 로고
    • Central venous catheter tip position: a continuing controversy
    • Vesely TM. (2003). Central venous catheter tip position: a continuing controversy. Journal of Vascular and Interventional Radiology; 14: 527-534.
    • (2003) Journal of Vascular and Interventional Radiology , vol.14 , pp. 527-534
    • Vesely, T.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.