메뉴 건너뛰기




Volumn 7, Issue 3, 2001, Pages 204-211

Central venous oxygen saturation monitoring in the critically ill patient

Author keywords

[No Author keywords available]

Indexed keywords

ARTERY CATHETERIZATION; CRITICAL ILLNESS; HEMODYNAMIC MONITORING; HUMAN; HYPOXEMIA; MORTALITY; MULTIPLE ORGAN FAILURE; RESUSCITATION; REVIEW; VENOUS OXYGEN TENSION;

EID: 0034977389     PISSN: 10705295     EISSN: None     Source Type: Journal    
DOI: 10.1097/00075198-200106000-00011     Document Type: Review
Times cited : (201)

References (71)
  • 3
  • 4
    • 0028144351 scopus 로고
    • Multiple organ failure syndrome in the 1990s: Systemic inflammatory response and organ dysfunction
    • (1994) JAMA , vol.271 , pp. 226-233
    • Beal, A.L.1    Cerra, F.B.2
  • 8
    • 0022521932 scopus 로고
    • Continuous venous oximetry in surgical patients
    • (1986) Ann Surg , vol.203 , pp. 329-333
    • Nelson, L.D.1
  • 15
    • 0021735922 scopus 로고
    • Continuous monitoring of mixed venous oxygen saturation in hemodynamically unstable patients
    • (1984) Chest , vol.86 , pp. 753-756
    • Birman, H.1    Haq, A.2    Hew, E.3
  • 19
    • 0028158498 scopus 로고
    • Patterns of oxygen transport in trauma and their relationship to outcome
    • (1994) Am J Emerg Med , vol.12 , pp. 107-112
    • Rady, M.Y.1
  • 21
    • 0022596943 scopus 로고
    • Continuous monitoring of mixed venous oxygen saturation during aortofemoral bypass grafting
    • (1986) Am Surg , vol.52 , pp. 114-115
    • Norwood, S.H.1    Nelson, L.D.2
  • 46
    • 0028059615 scopus 로고
    • Usefulness of central venous oxygen saturation monitoring during cardiopulmonary resuscitation: A comparative case study with end-tidal carbon dioxide monitoring
    • (1994) Intensive Care Med , vol.20 , pp. 450-451
    • Nakazawa, K.1    Hikawa, Y.2    Saitoh, Y.3
  • 49
    • 0027960552 scopus 로고
    • The effect of the total cumulative epinephrine dose administered during human CPR on hemodynamic, oxygen transport, and utilization variables in the postresuscitation period
    • (1994) Chest , vol.106 , pp. 1499-1507
    • Rivers, E.P.1    Wortsman, J.2    Rady, M.Y.3
  • 50
    • 0034675376 scopus 로고    scopus 로고
    • Accuracy of the advanced trauma life support guidelines for predicting systolic blood pressure using carotid, femoral, and radial pulses: Observational study
    • (2000) BMJ , vol.321 , pp. 673-674
    • Deakin, C.D.1    Low, J.L.2
  • 55
    • 0022647472 scopus 로고
    • Value of continuous monitoring of mixed venous blood oxygen saturation in the management of critically ill patients
    • (1986) Crit Care Med , vol.14 , pp. 132-134
    • Boutros, A.R.1    Lee, C.2
  • 61
    • 0032196504 scopus 로고    scopus 로고
    • Utility of clinical parameters of tissue oxygenation in a quantitative model of irreversible hemorrhagic shock
    • (1998) Shock , vol.10 , pp. 343-346
    • Shah, N.S.1    Kelly, E.2    Billiar, T.R.3
  • 64
    • 0026656421 scopus 로고
    • Influence of cardiac output on the correlation between mixed venous and central venous oxygen saturation
    • (1992) Br J Anaesth , vol.69 , pp. 409-410
    • Berridge, J.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.