메뉴 건너뛰기




Volumn 64, Issue 4, 2009, Pages 378-382

Comparison of central venous oxygen saturation and mixed venous oxygen saturation during liver transplantation

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BLOOD SAMPLING; CENTRAL VENOUS CATHETER; CENTRAL VENOUS CATHETERIZATION; CLINICAL ARTICLE; COMPARATIVE STUDY; CONTROLLED STUDY; FEMALE; HEMODYNAMICS; HUMAN; LIVER DISEASE; LIVER TRANSPLANTATION; MALE; OXYGEN SATURATION; VENOUS OXYGEN TENSION; BLOOD; METHODOLOGY; MIDDLE AGED; PEROPERATIVE CARE; PROSPECTIVE STUDY; REPRODUCIBILITY; SWAN GANZ CATHETER;

EID: 64149104953     PISSN: 00032409     EISSN: 13652044     Source Type: Journal    
DOI: 10.1111/j.1365-2044.2008.05793.x     Document Type: Article
Times cited : (33)

References (21)
  • 1
    • 0020571420 scopus 로고
    • Mixed venous oxygen saturation. Its role in the assessment of the critically ill patient
    • Kandel G, Aberman A. Mixed venous oxygen saturation. Its role in the assessment of the critically ill patient. Archives of Internal Medicine 1983; 143: 1400-1402
    • (1983) Archives of Internal Medicine , vol.143 , pp. 1400-1402
    • Kandel, G.1    Aberman, A.2
  • 2
    • 0020073376 scopus 로고
    • Tissue oxygenation in clinical medicine: An historical review
    • Miller MJ. Tissue oxygenation in clinical medicine: an historical review. Anesthesia & Analgesia 1982; 61: 527-535
    • (1982) Anesthesia & Analgesia , vol.61 , pp. 527-535
    • Miller, M.J.1
  • 3
    • 20644443911 scopus 로고    scopus 로고
    • The value of venous oximetry
    • DOI 10.1097/01.ccx.0000158092.64795.cf
    • Reinhart K, Bloos F. The value of venous oximetry. Current Opinion in Critical Care 2005; 11: 259-263 (Pubitemid 40835101)
    • (2005) Current Opinion in Critical Care , vol.11 , Issue.3 , pp. 259-263
    • Reinhart, K.1    Bloos, F.2
  • 4
    • 0031904641 scopus 로고    scopus 로고
    • Importance of the sampling site for measurement of mixed venous oxygen saturation in shock
    • Edwards JD, Mayall RM. Importance of the sampling site for measurement of mixed venous oxygen saturation in shock. Critical Care Medicine 1998; 26: 1356-1360 (Pubitemid 28384635)
    • (1998) Critical Care Medicine , vol.26 , Issue.8 , pp. 1356-1360
    • Edwards, J.D.1    Mayall, R.M.2
  • 5
    • 0026720548 scopus 로고
    • Monitoring of central venous oxygen saturation versus mixed venous oxygen saturation in critically ill patients
    • Martin C, Auffray JP, Badetti C, Perrin G, Papazian L, Gouin F. Monitoring of central venous oxygen saturation versus mixed venous oxygen saturation in critically ill patients. Intensive Care Medicine 1992; 18: 101-104
    • (1992) Intensive Care Medicine , vol.18 , pp. 101-104
    • Martin, C.1    Auffray, J.P.2    Badetti, C.3    Perrin, G.4    Papazian, L.5    Gouin, F.6
  • 6
    • 0027170740 scopus 로고
    • Influence of cardiac output on the correlation between mixed venous and central venous oxygen saturation [2]
    • Rigg JD, Nightingale PN, Faragher EB. Influence of cardiac output on the correlation between mixed venous and central venous oxygen saturation. British Journal of Anaesthesia 1993; 71: 459. (Pubitemid 23268900)
    • (1993) British Journal of Anaesthesia , vol.71 , Issue.3 , pp. 459
    • Rigg, J.D.1    Nightingale, P.N.2    Faragher, E.B.3    Berridge, J.C.4
  • 7
    • 23044442783 scopus 로고    scopus 로고
    • Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions
    • DOI 10.1097/00000542-200508000-00007
    • Dueck MH, Klimek M, Appenrodt S, Weigand C, Boerner U. Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions. Anesthesiology 2005; 103: 249-257 (Pubitemid 41076721)
    • (2005) Anesthesiology , vol.103 , Issue.2 , pp. 249-257
    • Dueck, M.H.1    Klimek, M.2    Appenrodt, S.3    Weigand, C.4    Boerner, U.5
  • 8
    • 0034167186 scopus 로고    scopus 로고
    • Bleeding problems in liver surgery and liver transplantation
    • Bechstein WO, Neuhaus P. [Bleeding problems in liver surgery and liver transplantation]. Chirurg 2000; 71: 363-368
    • (2000) Chirurg , vol.71 , pp. 363-368
    • Bechstein, W.O.1    Neuhaus, P.2
  • 9
    • 13144279329 scopus 로고    scopus 로고
    • Veno-venous bypass versus no bypass in orthotopic liver transplantation: Hemodynamic, metabolic, and renal data
    • Rossi G, Langer M, Maggi U, et al. Veno-venous bypass versus no bypass in orthotopic liver transplantation: hemodynamic, metabolic, and renal data. Transplantation Proceedings 1998; 30: 1871-1873.
    • (1998) Transplantation Proceedings , vol.30 , pp. 1871-1873
    • Rossi, G.1    Langer, M.2    Maggi, U.3
  • 10
    • 0028086298 scopus 로고
    • Reactive oxygen metabolites and reperfusion injury: Aberrant triggering of reticuloendothelial function
    • DOI 10.1016/S0140-6736(94)92276-4
    • Bulkley GB. Reactive oxygen metabolites and reperfusion injury: aberrant triggering of reticuloendothelial function. Lancet 1994; 344: 934-936 (Pubitemid 24295884)
    • (1994) Lancet , vol.344 , Issue.8927 , pp. 934-936
    • Bulkley, G.B.1
  • 11
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310 (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 12
    • 0024337859 scopus 로고
    • Comparison of central-venous to mixed-venous oxygen saturation during changes in oxygen supply/demand
    • Reinhart K, Rudolph T, Bredle DL, Hannemann L, Cain SM. Comparison of central-venous to mixed-venous oxygen saturation during changes in oxygen supply/demand. Chest 1989; 95: 1216-1221 (Pubitemid 19160143)
    • (1989) Chest , vol.95 , Issue.6 , pp. 1216-1221
    • Reinhart, K.1    Rudolph, T.2    Bredle, D.L.3    Hannemann, L.4    Cain, S.M.5
  • 13
    • 0031889126 scopus 로고    scopus 로고
    • Central and mixed venous blood oxygen correlate well during acute normovolemic hemodilution in anesthetized pigs
    • Schou H, Perez de Sa V, Larsson A. Central and mixed venous blood oxygen correlate well during acute normovolemic hemodilution in anesthetized pigs. Acta Anaesthesiologica Scandinavica 1998; 42: 172-177 (Pubitemid 28067880)
    • (1998) Acta Anaesthesiologica Scandinavica , vol.42 , Issue.2 , pp. 172-177
    • Schou, H.1    Perez De Sa, V.2    Larsson, A.3
  • 14
    • 4143058000 scopus 로고    scopus 로고
    • Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill
    • Reinhart K, Kuhn HJ, Hartog C, Bredle DL. Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill. Intensive Care Medicine 2004; 30: 1572-1578 (Pubitemid 39094958)
    • (2004) Intensive Care Medicine , vol.30 , Issue.8 , pp. 1572-1578
    • Reinhart, K.1    Kuhn, H.-J.2    Hartog, C.3    Bredle, D.L.4
  • 15
    • 0014555452 scopus 로고
    • Critical assessment of use of central venous oxygen saturation as a mirror of mixed venous oxygen in severely ill cardiac patients
    • Scheinman MM, Brown MA, Rapaport E. Critical assessment of use of central venous oxygen saturation as a mirror of mixed venous oxygen in severely ill cardiac patients. Circulation 1969; 40: 165-172
    • (1969) Circulation , vol.40 , pp. 165-172
    • Scheinman, M.M.1    Brown, M.A.2    Rapaport, E.3
  • 16
    • 0021735922 scopus 로고
    • Continuous monitoring of mixed venous oxygen saturation in hemodynamically unstable patients
    • Birman H, Haq A, Hew E, Aberman A. Continuous monitoring of mixed venous oxygen saturation in hemodynamically unstable patients. Chest 1984; 86: 753-756 (Pubitemid 15217652)
    • (1984) Chest , vol.86 , Issue.5 , pp. 753-756
    • Birman, H.1    Haq, A.2    Hew, E.3    Aberman, A.4
  • 17
    • 0025139615 scopus 로고
    • Measurement of gas exchange in anesthesia and during resuscitation: Principles and applications
    • Viale JP, Annat G, Delafosse B, Bouffard Y, Tissot S, Motin J. Measurement of gas exchange in anesthesia and during resuscitation: principles and applications. Agressologie 1990; 31: 62-63
    • (1990) Agressologie , vol.31 , pp. 62-63
    • Viale, J.P.1    Annat, G.2    Delafosse, B.3    Bouffard, Y.4    Tissot, S.5    Motin, J.6
  • 18
    • 0019971287 scopus 로고
    • Clinical evaluation of a new fiberoptic catheter oximeter during cardiac surgery
    • Waller JL, Kaplan JA, Bauman DI, Craver JM. Clinical evaluation of a new fiberoptic catheter oximeter during cardiac surgery. Anesthesia & Analgesia 1982; 61: 676-679 (Pubitemid 12047163)
    • (1982) Anesthesia and Analgesia , vol.61 , Issue.8 , pp. 676-679
    • Waller, J.L.1    Kaplan, J.A.2    Bauman, D.I.3    Craver, J.M.4
  • 19
    • 10444279213 scopus 로고    scopus 로고
    • Lack of equivalence between central and mixed venous oxygen saturation
    • DOI 10.1378/chest.126.6.1891
    • Chawla LS, Zia H, Gutierrez G, Katz NM, Seneff MG, Shah M. Lack of equivalence between central and mixed venous oxygen saturation. Chest 2004; 126: 1891-1896. (Pubitemid 39643995)
    • (2004) Chest , vol.126 , Issue.6 , pp. 1891-1896
    • Chawla, L.S.1    Zia, H.2    Gutierrez, G.3    Katz, N.M.4    Seneff, M.G.5    Shah, M.6
  • 21
    • 0036223888 scopus 로고    scopus 로고
    • Does mixed venous oxygen saturation reflect the changes in cardiac output during liver transplantation?
    • Acosta F, Sansano T, Palenciano CG, et al. Does mixed venous oxygen saturation reflect the changes in cardiac output during liver transplantation? Transplantation Proceedings 2002; 34: 277.
    • (2002) Transplantation Proceedings , vol.34 , pp. 277
    • Acosta, F.1    Sansano, T.2    Palenciano, C.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.