메뉴 건너뛰기




Volumn 126, Issue 6, 2004, Pages 1891-1896

Lack of equivalence between central and mixed venous oxygen saturation

Author keywords

Central venous oxygenation; Coronary sinus; Mixed venous oxygenation; Monitoring; Myocardial metabolism; Oxygen consumption; Oxygen delivery; Pulmonary artery catheter; Resuscitation

Indexed keywords

HEMOGLOBIN;

EID: 10444279213     PISSN: 00123692     EISSN: None     Source Type: Journal    
DOI: 10.1378/chest.126.6.1891     Document Type: Article
Times cited : (156)

References (24)
  • 1
    • 0032434106 scopus 로고    scopus 로고
    • Continuous recordings of mixed venous oxygen saturation during weaning from mechanical ventilation and the ramifications thereof
    • Jubran A, Mathru M, Dries D, et al. Continuous recordings of mixed venous oxygen saturation during weaning from mechanical ventilation and the ramifications thereof. Am J Respir Crit Care Med 1998; 158:1763-1769
    • (1998) Am J Respir Crit Care Med , vol.158 , pp. 1763-1769
    • Jubran, A.1    Mathru, M.2    Dries, D.3
  • 2
    • 0027955258 scopus 로고
    • Relationship between oxygen uptake and mixed venous oxygen saturation in the immediate postoperative period
    • Viale JP, Annat G, Lehot JJ, et al. Relationship between oxygen uptake and mixed venous oxygen saturation in the immediate postoperative period. Anesthesiology 1994; 80:278-283
    • (1994) Anesthesiology , vol.80 , pp. 278-283
    • Viale, J.P.1    Annat, G.2    Lehot, J.J.3
  • 3
    • 0022443467 scopus 로고
    • Continuous monitoring of mixed venous oxygen saturation in septic shock
    • Heiselman D, Jones J, Cannon L. Continuous monitoring of mixed venous oxygen saturation in septic shock. J Clin Monit 1986; 2:237-245
    • (1986) J Clin Monit , vol.2 , pp. 237-245
    • Heiselman, D.1    Jones, J.2    Cannon, L.3
  • 4
    • 0014555452 scopus 로고
    • Critical assessment of use of central venous oxygen saturation as a mirror of mixed venous oxygen in severely ill cardiac patients
    • Schienman MM, Brown MA, Rapaport E. Critical assessment of use of central venous oxygen saturation as a mirror of mixed venous oxygen in severely ill cardiac patients. Circulation 1969; 40:165-172
    • (1969) Circulation , vol.40 , pp. 165-172
    • Schienman, M.M.1    Brown, M.A.2    Rapaport, E.3
  • 6
    • 0343674564 scopus 로고    scopus 로고
    • A prospective randomized study of goal-oriented hemodynamic therapy in cardiac surgical patients
    • Polenen P, Ruokonen E, Hippelainen M, et al. A prospective randomized study of goal-oriented hemodynamic therapy in cardiac surgical patients. Anesth Analg 2000; 90:1052-1059
    • (2000) Anesth Analg , vol.90 , pp. 1052-1059
    • Polenen, P.1    Ruokonen, E.2    Hippelainen, M.3
  • 7
    • 0036715711 scopus 로고    scopus 로고
    • Complications of invasive monitoring
    • Bowdle TA. Complications of invasive monitoring. Anesthesiol Clin North America 2002; 20:571-588
    • (2002) Anesthesiol Clin North America , vol.20 , pp. 571-588
    • Bowdle, T.A.1
  • 8
    • 0035829842 scopus 로고    scopus 로고
    • Early goal-directed therapy in the treatment of severe sepsis and septic shock
    • Rivers E, Nguyen B, Havstad S, et al. Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 2001; 345:1368-1377
    • (2001) N Engl J Med , vol.345 , pp. 1368-1377
    • Rivers, E.1    Nguyen, B.2    Havstad, S.3
  • 9
    • 0018976210 scopus 로고
    • The lack of effect of variable blood withdrawal rates on the measurement of mixed venous oxygen saturation
    • Mihm F, Feeley TW, Rosenthal M, et al. The lack of effect of variable blood withdrawal rates on the measurement of mixed venous oxygen saturation. Chest 1980; 78:452-455
    • (1980) Chest , vol.78 , pp. 452-455
    • Mihm, F.1    Feeley, T.W.2    Rosenthal, M.3
  • 11
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman D. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.2
  • 12
    • 0034977389 scopus 로고    scopus 로고
    • Central venous oxygen saturation monitoring in the critically ill patient
    • Rivers EP, Ander DS, Powell D. Central venous oxygen saturation monitoring in the critically ill patient. Curr Opin Crit Care 2001; 7:204-211
    • (2001) Curr Opin Crit Care , vol.7 , pp. 204-211
    • Rivers, E.P.1    Ander, D.S.2    Powell, D.3
  • 13
    • 0027026684 scopus 로고
    • Does central venous oxygen saturation reflect continuous monitoring of mixed venous oxygen saturation?
    • Vincent J-L. Does central venous oxygen saturation reflect continuous monitoring of mixed venous oxygen saturation? Intensive Care Med 1992; 18:386-387
    • (1992) Intensive Care Med , vol.18 , pp. 386-387
    • Vincent, J.-L.1
  • 14
    • 0024337859 scopus 로고
    • Comparison of central-venous to mixed-venous oxygen saturation during changes in oxygen supply/demand
    • Reinhart K, Rudolph T, Bredle DL, et al. Comparison of central-venous to mixed-venous oxygen saturation during changes in oxygen supply/demand. Chest 1989; 95:1216-1221
    • (1989) Chest , vol.95 , pp. 1216-1221
    • Reinhart, K.1    Rudolph, T.2    Bredle, D.L.3
  • 15
    • 0031889126 scopus 로고    scopus 로고
    • Central and mixed venous blood oxygen correlate well during acute normovolemic hemodilution in anesthetized pigs
    • Schou H, Perez de Sa V, Larsson A. Central and mixed venous blood oxygen correlate well during acute normovolemic hemodilution in anesthetized pigs. Acta Anaesthesiol Scand 1998; 42:172-177
    • (1998) Acta Anaesthesiol Scand , vol.42 , pp. 172-177
    • Schou, H.1    Perez De Sa, V.2    Larsson, A.3
  • 16
    • 0026656421 scopus 로고
    • Influence of cardiac output on the correlation between mixed venous and central venous oxygen saturation
    • Berridge JC. Influence of cardiac output on the correlation between mixed venous and central venous oxygen saturation. Br J Anaesth 1992; 69:409-410
    • (1992) Br J Anaesth , vol.69 , pp. 409-410
    • Berridge, J.C.1
  • 17
    • 0031904641 scopus 로고    scopus 로고
    • Importance of the sampling site for measurement of mixed venous oxygen saturation in shock
    • Edwards JD, Mayall RM. Importance of the sampling site for measurement of mixed venous oxygen saturation in shock. Crit Care Med 1998; 26:1356-1360
    • (1998) Crit Care Med , vol.26 , pp. 1356-1360
    • Edwards, J.D.1    Mayall, R.M.2
  • 18
    • 0034950453 scopus 로고    scopus 로고
    • Central venous and mixed venous oxygen saturation in critically ill patients
    • Ladakis C, Myrianthefs P, Karabinis A, et al. Central venous and mixed venous oxygen saturation in critically ill patients. Respiration 2001; 68:279-285
    • (2001) Respiration , vol.68 , pp. 279-285
    • Ladakis, C.1    Myrianthefs, P.2    Karabinis, A.3
  • 19
    • 0015334492 scopus 로고
    • Central venous oxygen saturation in shock: A study in man
    • Lee J, Wright F, Barber R, et al. Central venous oxygen saturation in shock: a study in man. Anesthesiology 1972; 36:472-478
    • (1972) Anesthesiology , vol.36 , pp. 472-478
    • Lee, J.1    Wright, F.2    Barber, R.3
  • 20
    • 0026720548 scopus 로고
    • Monitoring of central venous oxygen saturation versus mixed venous oxygen saturation in critically ill patients
    • Martin C, Auffray JP, Badetti C, et al. Monitoring of central venous oxygen saturation versus mixed venous oxygen saturation in critically ill patients. Intensive Care Med 1992; 18:101-104
    • (1992) Intensive Care Med , vol.18 , pp. 101-104
    • Martin, C.1    Auffray, J.P.2    Badetti, C.3
  • 21
    • 0029329825 scopus 로고
    • Comparison of bench central and mixed pulmonary venous oxygen saturation in critically ill postsurgical patients
    • Pieri M, Brandi LS, Bertolini R, et al. Comparison of bench central and mixed pulmonary venous oxygen saturation in critically ill postsurgical patients. Minerva Anestesiol 1995; 61:285-291
    • (1995) Minerva Anestesiol , vol.61 , pp. 285-291
    • Pieri, M.1    Brandi, L.S.2    Bertolini, R.3
  • 22
    • 0020210848 scopus 로고
    • Can central venous blood replace mixed venous blood samples?
    • Tahvanainen J, Meretoja O, Nikki P. Can central venous blood replace mixed venous blood samples? Crit Care Med 1982; 10:758-761
    • (1982) Crit Care Med , vol.10 , pp. 758-761
    • Tahvanainen, J.1    Meretoja, O.2    Nikki, P.3
  • 23
    • 0034772740 scopus 로고    scopus 로고
    • Clinical applicability of the substitution of mixed venous oxygen saturation with central venous oxygen saturation
    • Turnaoglu S, Tugrul M, Camci E, et al. Clinical applicability of the substitution of mixed venous oxygen saturation with central venous oxygen saturation. J Cardiothorac Vasc Anesth 2001; 15:574-579
    • (2001) J Cardiothorac Vasc Anesth , vol.15 , pp. 574-579
    • Turnaoglu, S.1    Tugrul, M.2    Camci, E.3
  • 24
    • 0002085408 scopus 로고
    • The oxygen saturation of blood in the vena cavae, right heart chambers and pulmonary vessels of healthy subjects
    • Barratt-Boyes BG, Wood EH. The oxygen saturation of blood in the vena cavae, right heart chambers and pulmonary vessels of healthy subjects. J Lab Clin Med 1957; 50:93-106
    • (1957) J Lab Clin Med , vol.50 , pp. 93-106
    • Barratt-Boyes, B.G.1    Wood, E.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.