메뉴 건너뛰기




Volumn 19, Issue 2, 2008, Pages 270-280

Mass Selective Axial Ion Ejection from Linear Quadrupoles with Added Octopole Fields

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC DIPOLE MOMENTS; ELECTRIC EXCITATION; MASS SPECTROMETRY; OPTICAL RESOLVING POWER;

EID: 39149090033     PISSN: 10440305     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jasms.2007.10.025     Document Type: Article
Times cited : (22)

References (16)
  • 1
    • 0014538206 scopus 로고
    • Storage-Ring Ion Trap Derived from the Linear Quadrupole Radiofrequency Mass Filter
    • Church D.A. Storage-Ring Ion Trap Derived from the Linear Quadrupole Radiofrequency Mass Filter. J. Appl. Phys. 40 (1969) 3127-3134
    • (1969) J. Appl. Phys. , vol.40 , pp. 3127-3134
    • Church, D.A.1
  • 3
    • 0032934178 scopus 로고    scopus 로고
    • Performance Optimization and Fringing Field Modifications of a 24-mm Long RF-Only Quadrupole Mass Spectrometer
    • Hager J.W. Performance Optimization and Fringing Field Modifications of a 24-mm Long RF-Only Quadrupole Mass Spectrometer. Rapid Commun. Mass Spectrom. 13 (1999) 740-748
    • (1999) Rapid Commun. Mass Spectrom. , vol.13 , pp. 740-748
    • Hager, J.W.1
  • 4
    • 0036199431 scopus 로고    scopus 로고
    • A New Linear Ion Trap Mass Spectrometer
    • Hager J.W. A New Linear Ion Trap Mass Spectrometer. Rapid Commun. Mass Spectrom. 16 (2002) 512-526
    • (2002) Rapid Commun. Mass Spectrom. , vol.16 , pp. 512-526
    • Hager, J.W.1
  • 5
  • 6
    • 0000575240 scopus 로고
    • The Nonlinear Ion Trap. 3. Multipole Components in Three Types of Practical Ion Trap
    • Wang Y., and Franzen J. The Nonlinear Ion Trap. 3. Multipole Components in Three Types of Practical Ion Trap. Int. J. Mass Spectrom. Ion Processes 132 (1994) 155-172
    • (1994) Int. J. Mass Spectrom. Ion Processes , vol.132 , pp. 155-172
    • Wang, Y.1    Franzen, J.2
  • 7
    • 0141989738 scopus 로고    scopus 로고
    • Linear Quadrupoles with Added Octopole Fields
    • Sudakov M., and Douglas D.J. Linear Quadrupoles with Added Octopole Fields. Rapid Commun. Mass Spectrom. 17 (2003) 2290-2294
    • (2003) Rapid Commun. Mass Spectrom. , vol.17 , pp. 2290-2294
    • Sudakov, M.1    Douglas, D.J.2
  • 10
    • 0031763316 scopus 로고    scopus 로고
    • A New Linear Ion Trap Time-of-Flight System with Tandem Mass Spectrometry Capabilities
    • Campbell J.M., Collings B.A., and Douglas D.J. A New Linear Ion Trap Time-of-Flight System with Tandem Mass Spectrometry Capabilities. Rapid Commun. Mass Spectrom. 12 (1998) 1463-1474
    • (1998) Rapid Commun. Mass Spectrom. , vol.12 , pp. 1463-1474
    • Campbell, J.M.1    Collings, B.A.2    Douglas, D.J.3
  • 11
    • 0034582364 scopus 로고    scopus 로고
    • Excitation Frequencies of Ions Confined in a Quadrupole Field with Quadrupole Excitation
    • Sudakov M., Konenkov N., Douglas D.J., and Glebova T. Excitation Frequencies of Ions Confined in a Quadrupole Field with Quadrupole Excitation. J. Am. Soc. Mass Spectrom. 11 (2000) 10-18
    • (2000) J. Am. Soc. Mass Spectrom. , vol.11 , pp. 10-18
    • Sudakov, M.1    Konenkov, N.2    Douglas, D.J.3    Glebova, T.4
  • 14
    • 0033245758 scopus 로고    scopus 로고
    • Spatial Harmonics of the Field in a Quadrupole Mass Filter with Circular Electrodes
    • Douglas D.J., Glebova T.A., Konenkov N.V., and Sudakov M.Y. Spatial Harmonics of the Field in a Quadrupole Mass Filter with Circular Electrodes. Tech. Phys. 44 (1999) 1215-1219
    • (1999) Tech. Phys. , vol.44 , pp. 1215-1219
    • Douglas, D.J.1    Glebova, T.A.2    Konenkov, N.V.3    Sudakov, M.Y.4
  • 15
    • 0001527372 scopus 로고
    • Theory of High-Resolution Mass-Spectrometry Achieved Via Resonance Ejection in the Quadrupole Ion Trap
    • Goeringer D.E., Whitten W.B., Ramsey J.M., McLuckey S.A., and Glish G.L. Theory of High-Resolution Mass-Spectrometry Achieved Via Resonance Ejection in the Quadrupole Ion Trap. Anal. Chem. 64 (1992) 1434-1439
    • (1992) Anal. Chem. , vol.64 , pp. 1434-1439
    • Goeringer, D.E.1    Whitten, W.B.2    Ramsey, J.M.3    McLuckey, S.A.4    Glish, G.L.5
  • 16
    • 0001263520 scopus 로고
    • Resonance Ejection Ion-Trap Mass-Spectrometry and Nonlinear Field Contributions-the Effect of Scan Direction on Mass Resolution
    • Williams J.D., Cox K.A., Cooks R.G., McLuckey S.A., Hart K.J., and Goeringer D.E. Resonance Ejection Ion-Trap Mass-Spectrometry and Nonlinear Field Contributions-the Effect of Scan Direction on Mass Resolution. Anal. Chem. 66 (1994) 725-729
    • (1994) Anal. Chem. , vol.66 , pp. 725-729
    • Williams, J.D.1    Cox, K.A.2    Cooks, R.G.3    McLuckey, S.A.4    Hart, K.J.5    Goeringer, D.E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.