Volumn 68, Issue 7, 2013, Pages 1065-1070

Goal-directed fluid optimization based on stroke volume variation and cardiac index during one-lung ventilation in patients undergoing thoracoscopy lobectomy operations: A pilot study

Author keywords

Cardiac output; Fluid therapy; One lung ventilation; Stroke volume

Indexed keywords

AGED; ARTERIAL PRESSURE; ARTICLE; BLOOD GAS ANALYSIS; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; FEMALE; FLUID THERAPY; HEART RATE; HEART STROKE VOLUME; HUMAN; LUNG RESECTION; MALE; METHODOLOGY; MIDDLE AGED; ONE LUNG VENTILATION; PHYSIOLOGIC MONITORING; PHYSIOLOGY; PILOT STUDY; RANDOMIZED CONTROLLED TRIAL; REPRODUCIBILITY; TEMPORAL LOBECTOMY; THORACOSCOPY; TIME; TREATMENT OUTCOME;

EID: 84881082156     PISSN: 18075932     EISSN: None     Source Type: Journal    
DOI: 10.6061/clinics/2013(07)27     Document Type: Article
Times cited : (54)

References (30)
  • 1
    • 34948909129 scopus 로고    scopus 로고
    • Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: A pilot randomized controlled trial
    • Lopes MR, Oliveira MA, Pereira VO, Lemos IP, Auler JO Jr, Michard F. Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial. Crit Care. 2007;11(5):R100, http://dx.doi.org/10.1186/cc6117.
    • (2007) Crit Care. , vol.11 , Issue.5
    • Lopes, M.R.1    Oliveira, M.A.2    Pereira, V.O.3    Lemos, I.P.4    Auler Jr., J.O.5    Michard, F.6
  • 2
    • 74949092815 scopus 로고    scopus 로고
    • Goal-directed haemodynamic therapy and gastrointestinal complications in major surgery: A meta-analysis of randomized controlled trials
    • Giglio MT, Marucci M, Testini M, Brienza N. Goal-directed haemodynamic therapy and gastrointestinal complications in major surgery: a meta-analysis of randomized controlled trials. Br J Anaesth. 2009;103(5):637-46.
    • (2009) Br J Anaesth. , vol.103 , Issue.5 , pp. 637-646
    • Giglio, M.T.1    Marucci, M.2    Testini, M.3    Brienza, N.4
  • 3
    • 33846323221 scopus 로고    scopus 로고
    • Goaldirected fluid management reduces vasopressor and catecholamine use in cardiac surgery patients
    • Goepfert MS, Reuter DA, Akyol D, Lamm P, Kilger E, Goetz AE. Goaldirected fluid management reduces vasopressor and catecholamine use in cardiac surgery patients. Intensive Care Med. 2007;33(1):96-103, http://dx.doi.org/10.1007/s00134-006-0404-2.
    • (2007) Intensive Care Med. , vol.33 , Issue.1 , pp. 96-103
    • Goepfert, M.S.1    Reuter, D.A.2    Akyol, D.3    Lamm, P.4    Kilger, E.5    Goetz, A.E.6
  • 4
    • 48649094636 scopus 로고    scopus 로고
    • Perioperative monitoring of fluid responsiveness after esophageal surgery using stroke volume variation
    • Kobayashi M, Ko M, Kimura T, Meguro E, Hayakawa Y, Irinoda T, et al. Perioperative monitoring of fluid responsiveness after esophageal surgery using stroke volume variation. Expert Rev Med Devices. 2008;5(3):311-6, http://dx.doi.org/10.1586/17434440.5.3.311.
    • (2008) Expert Rev Med Devices. , vol.5 , Issue.3 , pp. 311-316
    • Kobayashi, M.1    Ko, M.2    Kimura, T.3    Meguro, E.4    Hayakawa, Y.5    Irinoda, T.6
  • 5
    • 84866249577 scopus 로고    scopus 로고
    • Goal-directed fluid therapy using stroke volume variation does not result in pulmonary fluid overload in thoracic surgery requiring onelung ventilation
    • Haas S, Eichhorn V, Hasbach T, Trepte C, Kutup A, Goetz AE, et al. Goal-directed fluid therapy using stroke volume variation does not result in pulmonary fluid overload in thoracic surgery requiring onelung ventilation. Crit Care Res Pract. 2012;2012:687018.
    • (2012) Crit Care Res Pract. , pp. 687018
    • Haas, S.1    Eichhorn, V.2    Hasbach, T.3    Trepte, C.4    Kutup, A.5    Goetz, A.E.6
  • 6
    • 43049162424 scopus 로고    scopus 로고
    • Evidence-based management of one-lung ventilation
    • Lohser J. Evidence-based management of one-lung ventilation. Anesthesiol Clin. 2008;26(2):241-72.
    • (2008) Anesthesiol Clin. , vol.26 , Issue.2 , pp. 241-272
    • Lohser, J.1
  • 7
  • 9
    • 79960030525 scopus 로고    scopus 로고
    • The effect of one-lung ventilation upon pulmonary inflammatory responses during lung resection
    • Sugasawa Y, Yamaguchi K, Kumakura S, Murakami T, Kugimiya T, Suzuki K, et al. The effect of one-lung ventilation upon pulmonary inflammatory responses during lung resection. J Anesth. 2011;25(2):170-7.
    • (2011) J Anesth. , vol.25 , Issue.2 , pp. 170-177
    • Sugasawa, Y.1    Yamaguchi, K.2    Kumakura, S.3    Murakami, T.4    Kugimiya, T.5    Suzuki, K.6
  • 10
    • 56749173549 scopus 로고    scopus 로고
    • Transoesophageal Doppler monitoring for fluid and hemodynamic treatment during lung surgery
    • Diaper J, Ellenberger C, Villiger Y, Robert J, Tschopp JM, Licker M. Transoesophageal Doppler monitoring for fluid and hemodynamic treatment during lung surgery. J Clin Monit Comput. 2008;22(5):367-74, http://dx.doi.org/10.1007/s10877-008-9144-x.
    • (2008) J Clin Monit Comput. , vol.22 , Issue.5 , pp. 367-374
    • Diaper, J.1    Ellenberger, C.2    Villiger, Y.3    Robert, J.4    Tschopp, J.M.5    Licker, M.6
  • 11
    • 79251509257 scopus 로고    scopus 로고
    • Utility of uncalibrated femoral stroke volume variation as a predictor of fluid responsiveness during the anhepatic phase of liver transplantation
    • Shin YH, Ko JS, Gwak MS, Kim GS, Lee JH, Lee SK. Utility of uncalibrated femoral stroke volume variation as a predictor of fluid responsiveness during the anhepatic phase of liver transplantation. Liver Transpl. 2011;17(1):53-9, http://dx.doi.org/10.1002/lt.22186.
    • (2011) Liver Transpl. , vol.17 , Issue.1 , pp. 53-59
    • Shin, Y.H.1    Ko, J.S.2    Gwak, M.S.3    Kim, G.S.4    Lee, J.H.5    Lee, S.K.6
  • 12
    • 84863237685 scopus 로고    scopus 로고
    • Stroke volume variation derived by arterial pulse contour analysis is a good indicator for preload estimation during liver transplantation
    • Su BC, Tsai YF, Cheng CW, Yu HP, Yang MW, Lee WC, et al. Stroke volume variation derived by arterial pulse contour analysis is a good indicator for preload estimation during liver transplantation. Transplant Proc. 2012;44(2):429-32, http://dx.doi.org/10.1016/j.transproceed.2011. 12.037.
    • (2012) Transplant Proc. , vol.44 , Issue.2 , pp. 429-432
    • Su, B.C.1    Tsai, Y.F.2    Cheng, C.W.3    Yu, H.P.4    Yang, M.W.5    Lee, W.C.6
  • 13
    • 79959473002 scopus 로고    scopus 로고
    • Does stroke volume variation predict intraoperative blood loss in living right donor hepatectomy?
    • Kim YK, Shin WJ, Song JG, Jun IG, Hwang GS. Does stroke volume variation predict intraoperative blood loss in living right donor hepatectomy? Transplant Proc. 2011;43(5):1407-11, http://dx.doi.org/ 10.1016/j.transproceed.2011.02.056.
    • (2011) Transplant Proc. , vol.43 , Issue.5 , pp. 1407-1411
    • Kim, Y.K.1    Shin, W.J.2    Song, J.G.3    Jun, I.G.4    Hwang, G.S.5
  • 14
    • 84862197659 scopus 로고    scopus 로고
    • Dynamic variables of fluid responsiveness during pneumoperitoneum and laparoscopic surgery
    • Høiseth LØ, Hoff IE, Myre K, Landsverk SA, Kirkebøen KA. Dynamic variables of fluid responsiveness during pneumoperitoneum and laparoscopic surgery. Acta Anaesthesiol Scand. 2012;56(6):777-86, http://dx.doi.org/10.1111/j.1399-6576.2011.02641.x.
    • (2012) Acta Anaesthesiol Scand. , vol.56 , Issue.6 , pp. 777-786
    • Høiseth, L.O.1    Hoff, I.E.2    Myre, K.3    Landsverk, S.A.4    Kirkebøen, K.A.5
  • 15
    • 78651494522 scopus 로고    scopus 로고
    • Pulse pressure variation and stroke volume variation during increased intraabdominal pressure: An experimental study
    • Jacques D, Bendjelid K, Duperret S, Colling J, Piriou V, Viale JP. Pulse pressure variation and stroke volume variation during increased intraabdominal pressure: an experimental study. Crit Care. 2011;15(1):R33, http://dx.doi.org/10.1186/cc9980.
    • (2011) Crit Care. , vol.15 , Issue.1
    • Jacques, D.1    Bendjelid, K.2    Duperret, S.3    Colling, J.4    Piriou, V.5    Viale, J.P.6
  • 16
    • 84856769201 scopus 로고    scopus 로고
    • Prediction of fluid responsiveness in septic shock patients: Comparing stroke volume variation by FloTrac/ Vigileo and automated pulse pressure variation
    • Khwannimit B, Bhurayanontachai R. Prediction of fluid responsiveness in septic shock patients: comparing stroke volume variation by FloTrac/ Vigileo and automated pulse pressure variation. Eur J Anaesthesiol. 2012;29(2):64-9.
    • (2012) Eur J Anaesthesiol. , vol.29 , Issue.2 , pp. 64-69
    • Khwannimit, B.1    Bhurayanontachai, R.2
  • 17
    • 84871200084 scopus 로고    scopus 로고
    • Ability of stroke volume variation measured by oesophageal Doppler monitoring to predict fluid responsiveness during surgery
    • Guinot PG, de Broca B, Abou Arab O, Diouf M, Badoux L, Bernard E, et al. Ability of stroke volume variation measured by oesophageal Doppler monitoring to predict fluid responsiveness during surgery. Br J Anaesth. 2013;110(1):28-33.
    • (2013) Br J Anaesth. , vol.110 , Issue.1 , pp. 28-33
    • Guinot, P.G.1    de Broca, B.2    Abou Arab, O.3    Diouf, M.4    Badoux, L.5    Bernard, E.6
  • 18
    • 84862786090 scopus 로고    scopus 로고
    • Anaesthesia. Does targeted pre-load optimisation by stroke volume variation attenuate a reduction in cardiac output in the prone position
    • Wu CY, Lee TS, Chan KC, Jeng CS, Cheng YJ. Anaesthesia. Does targeted pre-load optimisation by stroke volume variation attenuate a reduction in cardiac output in the prone position. Anaesthesia. 2012;67(7):760-4, http://dx.doi.org/10.1111/j.1365-2044.2012.07116.x.
    • (2012) Anaesthesia. , vol.67 , Issue.7 , pp. 760-764
    • Wu, C.Y.1    Lee, T.S.2    Chan, K.C.3    Jeng, C.S.4    Cheng, Y.J.5
  • 19
    • 59649123027 scopus 로고    scopus 로고
    • The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients
    • Cannesson M, Musard H, Desebbe O, Boucau C, Simon R, Hnaine R, et al. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg. 2009;108(2):513-7, http://dx.doi.org/10.1213/ ane.0b013e318192a36b.
    • (2009) Anesth Analg. , vol.108 , Issue.2 , pp. 513-517
    • Cannesson, M.1    Musard, H.2    Desebbe, O.3    Boucau, C.4    Simon, R.5    Hnaine, R.6
  • 21
    • 77957721654 scopus 로고    scopus 로고
    • Stroke volume variation as a predictor of fluid responsiveness in patients undergoing one-lung ventilation
    • Suehiro K, Okutani R. Stroke volume variation as a predictor of fluid responsiveness in patients undergoing one-lung ventilation. J Cardiothorac Vasc Anesth. 2010;24(5):772-5, http://dx.doi.org/10.1053/ j.jvca.2010.03.014.
    • (2010) J Cardiothorac Vasc Anesth. , vol.24 , Issue.5 , pp. 772-775
    • Suehiro, K.1    Okutani, R.2
  • 22
    • 84055195121 scopus 로고    scopus 로고
    • Predicting fluid responsiveness with stroke volume variation despite multiple extrasystoles
    • Cannesson M, Tran NP, Cho M, Hatib F, Michard F. Predicting fluid responsiveness with stroke volume variation despite multiple extrasystoles. Crit Care Med. 2012;40(1):193-8, http://dx.doi.org/10.1097/ CCM.0b013e31822ea119.
    • (2012) Crit Care Med. , vol.40 , Issue.1 , pp. 193-198
    • Cannesson, M.1    Tran, N.P.2    Cho, M.3    Hatib, F.4    Michard, F.5
  • 23
    • 77953960618 scopus 로고    scopus 로고
    • Goal-directed intraoperative therapy based on autocalibrated arterial pressure waveform analysis reduces hospital stay in high-risk surgical patients: A randomized, controlled trial
    • Mayer J, Boldt J, Mengistu AM, Rohm KD, Suttner S. Goal-directed intraoperative therapy based on autocalibrated arterial pressure waveform analysis reduces hospital stay in high-risk surgical patients: a randomized, controlled trial. Crit Care. 2010;14(1):R18, http://dx.doi. org/10.1186/cc8875.
    • (2010) Crit Care. , vol.14 , Issue.1
    • Mayer, J.1    Boldt, J.2    Mengistu, A.M.3    Rohm, K.D.4    Suttner, S.5
  • 24
    • 77953533489 scopus 로고    scopus 로고
    • Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: Results of prospective randomized study
    • Benes J, Chytra I, Altmann P, Hluchy M, Kasal E, Svitak R, et al. Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study. Crit Care. 2010;14(3):R118, http://dx.doi.org/10.1186/cc9070.
    • (2010) Crit Care. , vol.14 , Issue.3
    • Benes, J.1    Chytra, I.2    Altmann, P.3    Hluchy, M.4    Kasal, E.5    Svitak, R.6
  • 25
    • 78650952055 scopus 로고    scopus 로고
    • Dopexamine has no additional benefit in high-risk patients receiving goal-directed fluid therapy undergoing major abdominal surgery
    • Davies SJ, Yates D, Wilson RJ. Dopexamine has no additional benefit in high-risk patients receiving goal-directed fluid therapy undergoing major abdominal surgery. Anesth Analg. 2011;112(1):130-8, http://dx. doi.org/10.1213/ANE.0b013e3181fcea71.
    • (2011) Anesth Analg. , vol.112 , Issue.1 , pp. 130-138
    • Davies, S.J.1    Yates, D.2    Wilson, R.J.3
  • 26
    • 34948905567 scopus 로고    scopus 로고
    • Pulse pressure variation: Beyond the fluid management of patients with shock
    • Michard F, Lopes MR, Auler JO Jr. Pulse pressure variation: beyond the fluid management of patients with shock. Crit Care. 2007;11(3):131, http://dx.doi.org/10.1186/cc5905.
    • (2007) Crit Care. , vol.11 , Issue.3 , pp. 131
    • Michard, F.1    Lopes, M.R.2    Auler Jr., J.O.3
  • 27
    • 84859837708 scopus 로고    scopus 로고
    • Goal-directed fluid therapy in patients undergoing colorectal surgery
    • Toyama S, Shimoyama M. Goal-directed fluid therapy in patients undergoing colorectal surgery. Br J Anaesth. 2012;108(5):877-8.
    • (2012) Br J Anaesth. , vol.108 , Issue.5 , pp. 877-878
    • Toyama, S.1    Shimoyama, M.2
  • 28
    • 84856769201 scopus 로고    scopus 로고
    • Prediction of fluid responsiveness in septic shock patients: Comparing stroke volume variation by FloTrac/ Vigileo and automated pulse pressure variation
    • Khwannimit B, Bhurayanontachai R. Prediction of fluid responsiveness in septic shock patients: comparing stroke volume variation by FloTrac/ Vigileo and automated pulse pressure variation. Eur J Anaesthesiol. 2012;29(2):64-9.
    • (2012) Eur J Anaesthesiol. , vol.29 , Issue.2 , pp. 64-69
    • Khwannimit, B.1    Bhurayanontachai, R.2
  • 29
    • 84880557311 scopus 로고    scopus 로고
    • Examination of the usefulness of non-invasive stroke volume variation monitoring for adjusting fluid supplementation during laparoscopic adrenalectomy in patients with pheochromocytoma
    • Isosu T, Obara S, Ohashi S, Hosono A, Nakano Y, Imaizumi T, et al. Examination of the usefulness of non-invasive stroke volume variation monitoring for adjusting fluid supplementation during laparoscopic adrenalectomy in patients with pheochromocytoma. Fukushima J Med Sci. 2012;58(1):78-81, http://dx.doi.org/10.5387/fms.58.78.
    • (2012) Fukushima J Med Sci. , vol.58 , Issue.1 , pp. 78-81
    • Isosu, T.1    Obara, S.2    Ohashi, S.3    Hosono, A.4    Nakano, Y.5    Imaizumi, T.6
  • 30
    • 33748419499 scopus 로고    scopus 로고
    • Randomized clinical trial assessing the effect of Doppler-optimized fluid management on outcome after elective colorectal resection
    • Noblett SE, Snowden CP, Shenton BK, Horgan AF. Randomized clinical trial assessing the effect of Doppler-optimized fluid management on outcome after elective colorectal resection. Br J Surg. 2006;93:1069-76, http://dx.doi.org/10.1002/bjs.5454.
    • (2006) Br J Surg. , vol.93 , pp. 1069-1076
    • Noblett, S.E.1    Snowden, C.P.2    Shenton, B.K.3    Horgan, A.F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.