메뉴 건너뛰기




Volumn 67, Issue 7, 2012, Pages 760-764

Does targeted pre-load optimisation by stroke volume variation attenuate a reduction in cardiac output in the prone position

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; AIRWAY PRESSURE; ARTICLE; BENIGN TUMOR; BODY POSTURE; CLINICAL ARTICLE; CONTROLLED STUDY; FALLING; FEMALE; HEART OUTPUT; HEART PRELOAD; HEART RATE; HEART STROKE VOLUME; HUMAN; INTERVERTEBRAL DISKECTOMY; LAMINOPLASTY; MALE; MEAN ARTERIAL PRESSURE; OBSERVATIONAL STUDY; PILOT STUDY; SPINE FUSION; SPINE SURGERY; SPINE TUMOR; SUPINE POSITION; TIDAL VOLUME;

EID: 84862786090     PISSN: 00032409     EISSN: 13652044     Source Type: Journal    
DOI: 10.1111/j.1365-2044.2012.07116.x     Document Type: Article
Times cited : (12)

References (12)
  • 1
    • 38949110768 scopus 로고    scopus 로고
    • Anaesthesia in the prone position
    • DOI 10.1093/bja/aem380
    • Edgcombe H, Carter K, Yarrow S. Anaesthesia in the prone position. British Journal of Anaesthesia 2008; 100: 165-83. (Pubitemid 351773684)
    • (2008) British Journal of Anaesthesia , vol.100 , Issue.2 , pp. 165-183
    • Edgcombe, H.1    Carter, K.2    Yarrow, S.3
  • 2
    • 57349175920 scopus 로고    scopus 로고
    • Does central venous pressure predict fluid responsiveness?
    • Cole R. Does central venous pressure predict fluid responsiveness? Chest 2008; 134: 1351-2.
    • (2008) Chest , vol.134 , pp. 1351-1352
    • Cole, R.1
  • 3
    • 77949403336 scopus 로고    scopus 로고
    • Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery
    • Biais M, Bernard O, Ha JC, Degryse C, Sztark F. Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery. British Journal of Anaesthesia 2010; 104: 407-13.
    • (2010) British Journal of Anaesthesia , vol.104 , pp. 407-413
    • Biais, M.1    Bernard, O.2    Ha, J.C.3    Degryse, C.4    Sztark, F.5
  • 4
    • 26844502897 scopus 로고    scopus 로고
    • Edwards FloTrac sensor and Vigileo monitor: Easy, accurate, reliable cardiac output assessment using the arterial pulse wave
    • DOI 10.1586/17434440.2.5.523
    • Manecke GR. Edwards FloTrac sensor and Vigileo monitor: easy, accurate, reliable cardiac output assessment using the arterial pulse wave. Expert Review of Medical Devices 2005; 2: 523-7. (Pubitemid 41447649)
    • (2005) Expert Review of Medical Devices , vol.2 , Issue.5 , pp. 523-527
    • Manecke, G.R.1
  • 5
    • 34548266524 scopus 로고    scopus 로고
    • Clinical evaluation of the FloTrac/Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery
    • DOI 10.1093/bja/aem188
    • Button D, Weibel L, Reuthebuch O, Genoni M, Zollinger A, Hofer CK. Clinical evaluation of the FloTrac/Vigileo system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery. British Journal of Anaesthesia 2007; 99: 329-36. (Pubitemid 47316385)
    • (2007) British Journal of Anaesthesia , vol.99 , Issue.3 , pp. 329-336
    • Button, D.1    Weibel, L.2    Reuthebuch, O.3    Genoni, M.4    Zollinger, A.5    Hofer, C.K.6
  • 6
    • 78549274065 scopus 로고    scopus 로고
    • The analysis of variance in anaesthetic research: Statistics, biography and history
    • Pandit JJ. The analysis of variance in anaesthetic research: statistics, biography and history. Anaesthesia 2010; 65: 1212-20.
    • (2010) Anaesthesia , vol.65 , pp. 1212-1220
    • Pandit, J.J.1
  • 7
    • 0032007120 scopus 로고    scopus 로고
    • Hemodynamic evaluation of the prone position by transesophageal echocardiography
    • PII S095281809700216X
    • Toyota S, Amaki Y. Hemodynamic evaluation of the prone position by transesophageal echocardiography. Journal of Clinical Anesthesia 1998; 10: 32-5. (Pubitemid 128680279)
    • (1998) Journal of Clinical Anesthesia , vol.10 , Issue.1 , pp. 32-35
    • Toyota, S.1    Amaki, Y.2
  • 8
    • 33744819988 scopus 로고    scopus 로고
    • Effect of prone positioning systems on hemodynamic and cardiac function during lumbar spine surgery: An echocardiographic study
    • DOI 10.1097/01.brs.0000218485.96713.44, PII 0000763220060520000020
    • Dharmavaram S, Jellish WS, Nockels RP, et al. Effect of prone positioning systems on hemodynamic and cardiac function during lumbar spine surgery: an echocardiographic study. Spine 2006; 31: 1388-93. (Pubitemid 43833088)
    • (2006) Spine , vol.31 , Issue.12 , pp. 1388-1393
    • Dharmavaram, S.1    Jellish, W.S.2    Nockels, R.P.3    Shea, J.4    Mehmood, R.5    Ghanayem, A.6    Kleinman, B.7    Jacobs, W.8
  • 9
    • 47149111264 scopus 로고    scopus 로고
    • Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac and PiCCOplus system
    • Hofer CK, Senn A, Weibel L, Zollinger A. Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac and PiCCOplus system. Critical Care 2008; 12: R82.
    • (2008) Critical Care , vol.12
    • Hofer, C.K.1    Senn, A.2    Weibel, L.3    Zollinger, A.4
  • 12
    • 23044461875 scopus 로고    scopus 로고
    • Changes in arterial pressure during mechanical ventilation
    • DOI 10.1097/00000542-200508000-00026
    • Michard F. Changes in arterial pressure during mechanical ventilation. Anesthesiology 2005; 103: 419-28. (Pubitemid 41076740)
    • (2005) Anesthesiology , vol.103 , Issue.2 , pp. 419-428
    • Michard, F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.