메뉴 건너뛰기




Volumn 17, Issue 1, 2011, Pages 53-59

Utility of uncalibrated femoral stroke volume variation as a predictor of fluid responsiveness during the anhepatic phase of liver transplantation

Author keywords

[No Author keywords available]

Indexed keywords

HETASTARCH;

EID: 79251509257     PISSN: 15276465     EISSN: 15276473     Source Type: Journal    
DOI: 10.1002/lt.22186     Document Type: Article
Times cited : (23)

References (29)
  • 1
    • 43149109275 scopus 로고    scopus 로고
    • Anesthetic management of hepatic transplantation
    • Ozier Y, Klinck JR., Anesthetic management of hepatic transplantation. Curr Opin Anaesthesiol 2008; 21: 391-400.
    • (2008) Curr Opin Anaesthesiol , vol.21 , pp. 391-400
    • Ozier, Y.1    Klinck, J.R.2
  • 3
    • 33645102158 scopus 로고    scopus 로고
    • Effect of low central venous pressure and phlebotomy on blood product transfusion requirements during liver transplantations
    • Massicotte L, Lenis S, Thibeault L, Sassine MP, Seal RF, Roy A., Effect of low central venous pressure and phlebotomy on blood product transfusion requirements during liver transplantations. Liver Transpl 2006; 12: 117-123.
    • (2006) Liver Transpl , vol.12 , pp. 117-123
    • Massicotte, L.1    Lenis, S.2    Thibeault, L.3    Sassine, M.P.4    Seal, R.F.5    Roy, A.6
  • 5
    • 41049112314 scopus 로고    scopus 로고
    • Pro: Low central venous pressure during liver transplantationa-not too low
    • Schroeder RA, Kuo PC., Pro: low central venous pressure during liver transplantationa-not too low. J Cardiothorac Vasc Anesth 2008; 22: 311-314.
    • (2008) J Cardiothorac Vasc Anesth , vol.22 , pp. 311-314
    • Schroeder, R.A.1    Kuo, P.C.2
  • 6
    • 0035080242 scopus 로고    scopus 로고
    • Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery
    • Berkenstadt H, Margalit N, Hadani M, Friedman Z, Segal E, Villa Y, Perel A,. Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg 2001; 92: 984-989.
    • (2001) Anesth Analg , vol.92 , pp. 984-989
    • Berkenstadt, H.1    Margalit, N.2    Hadani, M.3    Friedman, Z.4    Segal, E.5    Villa, Y.6    Perel, A.7
  • 7
    • 8744275421 scopus 로고    scopus 로고
    • Pulse pressure variation predicts fluid responsiveness following coronary artery bypass surgery
    • Kramer A, Zygun D, Hawes H, Easton P, Ferland A., Pulse pressure variation predicts fluid responsiveness following coronary artery bypass surgery. Chest 2004; 126: 1563-1568.
    • (2004) Chest , vol.126 , pp. 1563-1568
    • Kramer, A.1    Zygun, D.2    Hawes, H.3    Easton, P.4    Ferland, A.5
  • 8
    • 34548247113 scopus 로고    scopus 로고
    • Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness
    • Lee JH, Kim JT, Yoon SZ, Lim YJ, Jeon Y, Bahk JH, Kim CS,. Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness. Br J Anaesth 2007; 99: 343-348.
    • (2007) Br J Anaesth , vol.99 , pp. 343-348
    • Lee, J.H.1    Kim, J.T.2    Yoon, S.Z.3    Lim, Y.J.4    Jeon, Y.5    Bahk, J.H.6    Kim, C.S.7
  • 9
    • 0842284105 scopus 로고    scopus 로고
    • Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis
    • Marx G, Cope T, McCrossan L, Swaraj S, Cowan C, Mostafa SM, et al. Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis. Eur J Anaesthesiol 2004; 21: 132-138.
    • (2004) Eur J Anaesthesiol , vol.21 , pp. 132-138
    • Marx, G.1    Cope, T.2    McCrossan, L.3    Swaraj, S.4    Cowan, C.5    Mostafa, S.M.6
  • 10
    • 0033924592 scopus 로고    scopus 로고
    • Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure
    • Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, et al. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 2000; 162: 134-138.
    • (2000) Am J Respir Crit Care Med , vol.162 , pp. 134-138
    • Michard, F.1    Boussat, S.2    Chemla, D.3    Anguel, N.4    Mercat, A.5    Lecarpentier, Y.6
  • 11
    • 0036283553 scopus 로고    scopus 로고
    • Predicting fluid responsiveness in ICU patients: A critical analysis of the evidence
    • Michard F, Teboul JL., Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 2002; 121: 2000-2008.
    • (2002) Chest , vol.121 , pp. 2000-2008
    • Michard, F.1    Teboul, J.L.2
  • 13
    • 56449113016 scopus 로고    scopus 로고
    • Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation
    • Biais M, Nouette-Gaulain K, Cottenceau V, Revel P, Sztark F., Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation. Br J Anaesth 2008; 101: 761-768.
    • (2008) Br J Anaesth , vol.101 , pp. 761-768
    • Biais, M.1    Nouette-Gaulain, K.2    Cottenceau, V.3    Revel, P.4    Sztark, F.5
  • 14
    • 68049133165 scopus 로고    scopus 로고
    • Evaluation of the pulse pressure variation index as a predictor of fluid responsiveness during orthotopic liver transplantation
    • Gouvêa G, Diaz R, Auler L, Toledo R, Martinho JM., Evaluation of the pulse pressure variation index as a predictor of fluid responsiveness during orthotopic liver transplantation. Br J Anaesth 2009; 103: 238-243.
    • (2009) Br J Anaesth , vol.103 , pp. 238-243
    • Gouvêa, G.1    Diaz, R.2    Auler, L.3    Toledo, R.4    Martinho, J.M.5
  • 15
    • 0020083498 scopus 로고
    • The meaning and use of the area under a receiver operating characteristic (ROC) curve
    • Hanley JA, McNeil BJ., The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 1982; 143: 29-36.
    • (1982) Radiology , vol.143 , pp. 29-36
    • Hanley, J.A.1    McNeil, B.J.2
  • 16
    • 0020524559 scopus 로고
    • A method of comparing the areas under the receiver operating characteristic curves derived from the same cases
    • Hanley JA, McNeil BJ., A method of comparing the areas under the receiver operating characteristic curves derived from the same cases. Radiology 1983; 148: 839-843.
    • (1983) Radiology , vol.148 , pp. 839-843
    • Hanley, J.A.1    McNeil, B.J.2
  • 17
    • 49949117483 scopus 로고    scopus 로고
    • The intrathoracic blood volume index as an indicator of fluid responsiveness in critically ill patients with acute circulatory failure: A comparison with central venous pressure
    • Muller L, Louart G, Bengler C, Fabbro-Peray P, Carr J, Ripart J, et al. The intrathoracic blood volume index as an indicator of fluid responsiveness in critically ill patients with acute circulatory failure: a comparison with central venous pressure. Anesth Analg 2008; 107: 607-613.
    • (2008) Anesth Analg , vol.107 , pp. 607-613
    • Muller, L.1    Louart, G.2    Bengler, C.3    Fabbro-Peray, P.4    Carr, J.5    Ripart, J.6
  • 18
    • 0346099357 scopus 로고    scopus 로고
    • Association of intraoperative hypotension and pulmonary hypertension with adverse outcomes after orthotopic liver transplantation
    • Reich DL, Wood RK Jr, Emre S, Bodian CA, Hossain S, Krol M, Feierman D,. Association of intraoperative hypotension and pulmonary hypertension with adverse outcomes after orthotopic liver transplantation. J Cardiothorac Vasc Anesth 2003; 17: 699-702.
    • (2003) J Cardiothorac Vasc Anesth , vol.17 , pp. 699-702
    • Reich, D.L.1    Wood, Jr.R.K.2    Emre, S.3    Bodian, C.A.4    Hossain, S.5    Krol, M.6    Feierman, D.7
  • 19
    • 12144287425 scopus 로고    scopus 로고
    • Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects
    • Kumar A, Anel R, Bunnell E, Habet K, Zanotti S, Marshall S, et al. Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. Crit Care Med 2004; 32: 691-699.
    • (2004) Crit Care Med , vol.32 , pp. 691-699
    • Kumar, A.1    Anel, R.2    Bunnell, E.3    Habet, K.4    Zanotti, S.5    Marshall, S.6
  • 20
    • 33845958648 scopus 로고    scopus 로고
    • Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge
    • Osman D, Ridel C, Ray P, Monnet X, Anguel N, Richard C, Teboul JL,. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med 2007; 35: 64-68.
    • (2007) Crit Care Med , vol.35 , pp. 64-68
    • Osman, D.1    Ridel, C.2    Ray, P.3    Monnet, X.4    Anguel, N.5    Richard, C.6    Teboul, J.L.7
  • 21
    • 35448947413 scopus 로고    scopus 로고
    • Incidence of severe ventricular arrhythmias during pulmonary artery catheterization in liver allograft recipients
    • Gwak MS, Kim JA, Kim GS, Choi SJ, Ahn H, Lee JJ, et al. Incidence of severe ventricular arrhythmias during pulmonary artery catheterization in liver allograft recipients. Liver Transpl 2007; 13: 1451-1454.
    • (2007) Liver Transpl , vol.13 , pp. 1451-1454
    • Gwak, M.S.1    Kim, J.A.2    Kim, G.S.3    Choi, S.J.4    Ahn, H.5    Lee, J.J.6
  • 22
    • 23044461875 scopus 로고    scopus 로고
    • Changes in arterial pressure during mechanical ventilation
    • Michard F., Changes in arterial pressure during mechanical ventilation. Anesthesiology 2005; 103: 419-428.
    • (2005) Anesthesiology , vol.103 , pp. 419-428
    • Michard, F.1
  • 23
    • 65549167377 scopus 로고    scopus 로고
    • Influence of respiratory rate on stroke volume variation in mechanically ventilated patients
    • De Backer D, Taccone FS, Holsten R, Ibrahimi F, Vincent JL., Influence of respiratory rate on stroke volume variation in mechanically ventilated patients. Anesthesiology 2009; 110: 1092-1097.
    • (2009) Anesthesiology , vol.110 , pp. 1092-1097
    • De Backer, D.1    Taccone, F.S.2    Holsten, R.3    Ibrahimi, F.4    Vincent, J.L.5
  • 24
    • 71249127973 scopus 로고    scopus 로고
    • Comparison of stroke volume variations derived from radial and femoral arterial pressure waveforms during liver transplantation
    • Kim YK, Shin WJ, Song JG, Jun IG, Kim HY, Seong SH, Hwang GS,. Comparison of stroke volume variations derived from radial and femoral arterial pressure waveforms during liver transplantation. Transplant Proc 2009; 41: 4220-4228.
    • (2009) Transplant Proc , vol.41 , pp. 4220-4228
    • Kim, Y.K.1    Shin, W.J.2    Song, J.G.3    Jun, I.G.4    Kim, H.Y.5    Seong, S.H.6    Hwang, G.S.7
  • 25
    • 0036219991 scopus 로고    scopus 로고
    • Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery
    • Reuter DA, Felbinger TW, Schmidt C, Kilger E, Goedje O, Lamm P, Goetz AE,. Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery. Intensive Care Med 2002; 28: 392-398.
    • (2002) Intensive Care Med , vol.28 , pp. 392-398
    • Reuter, D.A.1    Felbinger, T.W.2    Schmidt, C.3    Kilger, E.4    Goedje, O.5    Lamm, P.6    Goetz, A.E.7
  • 26
    • 22944441604 scopus 로고    scopus 로고
    • Radial to femoral arterial blood pressure differences during liver transplantation
    • Arnal D, Garutti I, Perez-Pena J, Olmedilla L, Tzenkov IG., Radial to femoral arterial blood pressure differences during liver transplantation. Anaesthesia 2005; 60: 766-771.
    • (2005) Anaesthesia , vol.60 , pp. 766-771
    • Arnal, D.1    Garutti, I.2    Perez-Pena, J.3    Olmedilla, L.4    Tzenkov, I.G.5
  • 27
    • 33749587013 scopus 로고    scopus 로고
    • 6/2/06 perioperative assessment of the cardiovascular system in ESLD and transplantation
    • De Wolf AM., 6/2/06 perioperative assessment of the cardiovascular system in ESLD and transplantation. Int Anesthesiol Clin 2006; 44: 59-78.
    • (2006) Int Anesthesiol Clin , vol.44 , pp. 59-78
    • De Wolf, A.M.1
  • 28
    • 54549120299 scopus 로고    scopus 로고
    • Current approach to intraoperative monitoring in liver transplantation
    • Krenn CG, De Wolf AM., Current approach to intraoperative monitoring in liver transplantation. Curr Opin Organ Transplant 2008; 13: 285-290.
    • (2008) Curr Opin Organ Transplant , vol.13 , pp. 285-290
    • Krenn, C.G.1    De Wolf, A.M.2
  • 29
    • 23744504093 scopus 로고    scopus 로고
    • Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting
    • Hofer CK, Muller SM, Furrer L, Klaghofer R, Genoni M, Zollinger A., Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting. Chest 2005; 128: 848-854.
    • (2005) Chest , vol.128 , pp. 848-854
    • Hofer, C.K.1    Muller, S.M.2    Furrer, L.3    Klaghofer, R.4    Genoni, M.5    Zollinger, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.