-
1
-
-
36149042452
-
Multi-planar image formation using NMR spin echoes
-
Mansfield P. Multi-planar image formation using NMR spin echoes. J Phys C 1977, 10:349-352.
-
(1977)
J Phys C
, vol.10
, pp. 349-352
-
-
Mansfield, P.1
-
2
-
-
0025630001
-
Brain magnetic resonance imaging with contrast dependent on blood oxygenation
-
Ogawa S., Lee T.M., Kay A.R., Tank D.W. Brain magnetic resonance imaging with contrast dependent on blood oxygenation. Proc Natl Acad Sci U S A 1990, 87:9868-9872.
-
(1990)
Proc Natl Acad Sci U S A
, vol.87
, pp. 9868-9872
-
-
Ogawa, S.1
Lee, T.M.2
Kay, A.R.3
Tank, D.W.4
-
3
-
-
0027263961
-
Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model
-
Ogawa S., Menon R.S., Tank D.W., Kim S.G., Merkle H., Ellermann J.M., et al. Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model. Biophys J 1993, 64:803-812.
-
(1993)
Biophys J
, vol.64
, pp. 803-812
-
-
Ogawa, S.1
Menon, R.S.2
Tank, D.W.3
Kim, S.G.4
Merkle, H.5
Ellermann, J.M.6
-
4
-
-
0025256879
-
Echo-planar imaging with asymmetric gradient modulation and inner-volume excitation
-
Feinberg D.A., Turner R., Jakab P.D., von Kienlin M. Echo-planar imaging with asymmetric gradient modulation and inner-volume excitation. Magn Reson Med 1990, 13:162-169.
-
(1990)
Magn Reson Med
, vol.13
, pp. 162-169
-
-
Feinberg, D.A.1
Turner, R.2
Jakab, P.D.3
von Kienlin, M.4
-
5
-
-
28444484999
-
High-resolution DTI with 2D interleaved multislice reduced FOV single-shot diffusion-weighted EPI (2D ss-rFOV-DWEPI)
-
Jeong E.K., Kim S.E., Guo J., Kholmovski E.G., Parker D.L. High-resolution DTI with 2D interleaved multislice reduced FOV single-shot diffusion-weighted EPI (2D ss-rFOV-DWEPI). Magn Reson Med 2005, 54:1575-1579.
-
(2005)
Magn Reson Med
, vol.54
, pp. 1575-1579
-
-
Jeong, E.K.1
Kim, S.E.2
Guo, J.3
Kholmovski, E.G.4
Parker, D.L.5
-
6
-
-
0036135412
-
ADC mapping of the human optic nerve: increased resolution, coverage, and reliability with CSF-suppressed ZOOM-EPI
-
Wheeler-Kingshott C.A., Parker G.J., Symms M.R., Hickman S.J., Tofts P.S., Miller D.H., et al. ADC mapping of the human optic nerve: increased resolution, coverage, and reliability with CSF-suppressed ZOOM-EPI. Magn Reson Med 2002, 47:24-31.
-
(2002)
Magn Reson Med
, vol.47
, pp. 24-31
-
-
Wheeler-Kingshott, C.A.1
Parker, G.J.2
Symms, M.R.3
Hickman, S.J.4
Tofts, P.S.5
Miller, D.H.6
-
7
-
-
84867842053
-
Isotropic submillimeter fMRI in the human brain at 7T: combining reduced field-of-view imaging and partially parallel acquisitions
-
Heidemann R.M., Ivanov D., Trampel R., Fassano F., Meyer H., Pfeuffer J., et al. Isotropic submillimeter fMRI in the human brain at 7T: combining reduced field-of-view imaging and partially parallel acquisitions. Magn Reson Med 2012, 68:1506-1516.
-
(2012)
Magn Reson Med
, vol.68
, pp. 1506-1516
-
-
Heidemann, R.M.1
Ivanov, D.2
Trampel, R.3
Fassano, F.4
Meyer, H.5
Pfeuffer, J.6
-
8
-
-
84857013169
-
K-space and q-space: combining ultra-high spatial and angular resolution in diffusion imaging using ZOOPPA at 7T
-
Heidemann R.M., Anwander A., Feiweier T., Knösche T.R., Turner R. k-space and q-space: combining ultra-high spatial and angular resolution in diffusion imaging using ZOOPPA at 7T. Neuroimage 2012, 60:967-978.
-
(2012)
Neuroimage
, vol.60
, pp. 967-978
-
-
Heidemann, R.M.1
Anwander, A.2
Feiweier, T.3
Knösche, T.R.4
Turner, R.5
-
9
-
-
0347361501
-
Two-dimensional spatially selective spin inversion and spin-echo refocusing with a single nuclear magnetic resonance pulse
-
Bottomley P.A., Hardy C.J. Two-dimensional spatially selective spin inversion and spin-echo refocusing with a single nuclear magnetic resonance pulse. J Appl Phys 1987, 62:4284-4290.
-
(1987)
J Appl Phys
, vol.62
, pp. 4284-4290
-
-
Bottomley, P.A.1
Hardy, C.J.2
-
10
-
-
45149145242
-
A k-space analysis of small-tip-angle excitations
-
Pauly J., Nishimura D., Macovski A. A k-space analysis of small-tip-angle excitations. J Magn Reson 1989, 81:43-56.
-
(1989)
J Magn Reson
, vol.81
, pp. 43-56
-
-
Pauly, J.1
Nishimura, D.2
Macovski, A.3
-
11
-
-
0000768763
-
A linear class of large-tip-angle selective excitation pulses
-
Pauly J., Nishimura D., Macovski A. A linear class of large-tip-angle selective excitation pulses. J Magn Reson 1989, 82:571-587.
-
(1989)
J Magn Reson
, vol.82
, pp. 571-587
-
-
Pauly, J.1
Nishimura, D.2
Macovski, A.3
-
12
-
-
0036260582
-
Two-dimensional spatially selective RF excitation pulses in echo-planar imaging
-
Rieseberg S., Frahm J., Finsterbusch J. Two-dimensional spatially selective RF excitation pulses in echo-planar imaging. Magn Reson Med 2002, 47:1186-1193.
-
(2002)
Magn Reson Med
, vol.47
, pp. 1186-1193
-
-
Rieseberg, S.1
Frahm, J.2
Finsterbusch, J.3
-
13
-
-
49049097277
-
DWI of the spinal cord with reduced FOV single-shot EPI
-
Saritas E.U., Cunningham C.H., Lee J.H., Han E.T., Nishimura D.G. DWI of the spinal cord with reduced FOV single-shot EPI. Magn Reson Med 2008, 60:468-473.
-
(2008)
Magn Reson Med
, vol.60
, pp. 468-473
-
-
Saritas, E.U.1
Cunningham, C.H.2
Lee, J.H.3
Han, E.T.4
Nishimura, D.G.5
-
14
-
-
65249146101
-
High-resolution diffusion tensor imaging with inner-field-of-view EPI
-
Finsterbusch J. High-resolution diffusion tensor imaging with inner-field-of-view EPI. J Magn Reson Imaging 2009, 29:987-993.
-
(2009)
J Magn Reson Imaging
, vol.29
, pp. 987-993
-
-
Finsterbusch, J.1
-
15
-
-
77952863450
-
Fast-spin-echo imaging of inner fields-of-view with 2D-selective RF excitations
-
Finsterbusch J. Fast-spin-echo imaging of inner fields-of-view with 2D-selective RF excitations. J Magn Reson Imaging 2010, 31:1530-1537.
-
(2010)
J Magn Reson Imaging
, vol.31
, pp. 1530-1537
-
-
Finsterbusch, J.1
-
16
-
-
77954133822
-
Reduced field-of-view single-shot fast spin echo imaging using two-dimensional spatially selective radiofrequency pulses
-
Yuan J., Zhao T.C., Tang Y., Panych L.P. Reduced field-of-view single-shot fast spin echo imaging using two-dimensional spatially selective radiofrequency pulses. J Magn Reson Imaging 2010, 32:242-248.
-
(2010)
J Magn Reson Imaging
, vol.32
, pp. 242-248
-
-
Yuan, J.1
Zhao, T.C.2
Tang, Y.3
Panych, L.P.4
-
17
-
-
84858722466
-
Improving the performance of diffusion-weighted inner field-of-view echo-planar imaging based on 2D-selective radiofrequency excitations by tilting the excitation plane
-
Finsterbusch J. Improving the performance of diffusion-weighted inner field-of-view echo-planar imaging based on 2D-selective radiofrequency excitations by tilting the excitation plane. J Magn Reson Imaging 2012, 35:984-992.
-
(2012)
J Magn Reson Imaging
, vol.35
, pp. 984-992
-
-
Finsterbusch, J.1
-
18
-
-
84862573214
-
Diffusion tensor imaging of the normal pediatric spinal cord using an inner field of view echo-planar imaging sequence
-
Barakat N., Mohamed F.B., Hunter L.N., Shah P., Faro S.H., Samdani A.F., et al. Diffusion tensor imaging of the normal pediatric spinal cord using an inner field of view echo-planar imaging sequence. Am J Neuroradiol 2012, 33:1127-1133.
-
(2012)
Am J Neuroradiol
, vol.33
, pp. 1127-1133
-
-
Barakat, N.1
Mohamed, F.B.2
Hunter, L.N.3
Shah, P.4
Faro, S.H.5
Samdani, A.F.6
-
19
-
-
84862200953
-
Diffusion tensor imaging in pediatric spinal cord injury: preliminary examination of reliability and clinical correlation
-
Mulcahey MJ, Samdani A, Gaughan J, Barakat N, Faro S, Betz RR, Finsterbusch J, Mohamed FB. Diffusion tensor imaging in pediatric spinal cord injury: preliminary examination of reliability and clinical correlation. Spine (Phila Pa 1976); 37:E797-E803.
-
Spine (Phila Pa 1976)
, vol.37
-
-
Mulcahey, M.J.1
Samdani, A.2
Gaughan, J.3
Barakat, N.4
Faro, S.5
Betz, R.R.6
Finsterbusch, J.7
Mohamed, F.B.8
-
20
-
-
79956120161
-
Reduced field-of-view diffusion imaging of the human spinal cord: comparison with conventional single-shot echo-planar imaging
-
Zaharchuk G., Saritas E.U., Andre J.B., Chin C.T., Rosenberg J., Brosnan T.J., et al. Reduced field-of-view diffusion imaging of the human spinal cord: comparison with conventional single-shot echo-planar imaging. Am J Neuroradiol 2011, 32:813-820.
-
(2011)
Am J Neuroradiol
, vol.32
, pp. 813-820
-
-
Zaharchuk, G.1
Saritas, E.U.2
Andre, J.B.3
Chin, C.T.4
Rosenberg, J.5
Brosnan, T.J.6
-
21
-
-
84859001402
-
High-resolution diffusion-weighted magnetic resonance imaging in patients with locally advanced breast cancer
-
Singer L., Wilmes L.J., Saritas E.U., Shankaranarayan A., Proctor E., Wisner D.J., et al. High-resolution diffusion-weighted magnetic resonance imaging in patients with locally advanced breast cancer. Acad Radiol 2012, 19:526-534.
-
(2012)
Acad Radiol
, vol.19
, pp. 526-534
-
-
Singer, L.1
Wilmes, L.J.2
Saritas, E.U.3
Shankaranarayan, A.4
Proctor, E.5
Wisner, D.J.6
-
22
-
-
0028235727
-
Functional NMR imaging using fast spin echo at 1.5T
-
Constable R.T., Kennan R.P., Pruce A., McCarthy G., Gore J.C. Functional NMR imaging using fast spin echo at 1.5T. Magn Reson Med 1994, 31:686-690.
-
(1994)
Magn Reson Med
, vol.31
, pp. 686-690
-
-
Constable, R.T.1
Kennan, R.P.2
Pruce, A.3
McCarthy, G.4
Gore, J.C.5
-
23
-
-
33846964886
-
Fast spin echo sequences for bold functional MRI
-
Poser B.A., Norris D.G. Fast spin echo sequences for bold functional MRI. MAGMA 2007, 20:11-17.
-
(2007)
MAGMA
, vol.20
, pp. 11-17
-
-
Poser, B.A.1
Norris, D.G.2
-
24
-
-
84862989344
-
Spin echo fMRI: the poor relation?
-
Norris D.G. Spin echo fMRI: the poor relation?. Neuroimage 2012, 62:1109-1115.
-
(2012)
Neuroimage
, vol.62
, pp. 1109-1115
-
-
Norris, D.G.1
-
25
-
-
7544243385
-
Calibration of echo-planar 2D-selective RF excitation pulses
-
Oelhafen M., Pruessmann K.P., Kozerke S., Boesiger P. Calibration of echo-planar 2D-selective RF excitation pulses. Magn Reson Med 2004, 52:1136-1145.
-
(2004)
Magn Reson Med
, vol.52
, pp. 1136-1145
-
-
Oelhafen, M.1
Pruessmann, K.P.2
Kozerke, S.3
Boesiger, P.4
-
26
-
-
0034328379
-
Gradient-echo line scan imaging using 2D-selective RF excitation
-
Finsterbusch J., Frahm J. Gradient-echo line scan imaging using 2D-selective RF excitation. J Magn Reson 2000, 147:17-25.
-
(2000)
J Magn Reson
, vol.147
, pp. 17-25
-
-
Finsterbusch, J.1
Frahm, J.2
-
27
-
-
0032712873
-
SENSE: Sensitivity encoding for fast MRI
-
Pruessmann K.P., Weiger M., Scheidegger M.B., Boesiger P. SENSE: Sensitivity encoding for fast MRI. Magn Reson Med 1999, 42:952-962.
-
(1999)
Magn Reson Med
, vol.42
, pp. 952-962
-
-
Pruessmann, K.P.1
Weiger, M.2
Scheidegger, M.B.3
Boesiger, P.4
-
28
-
-
0036263907
-
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
-
Griswold M.A., Jakob P.M., Heidemann R.M., Nittka M., Jellus V., Wang J., et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002, 47:1202-1210.
-
(2002)
Magn Reson Med
, vol.47
, pp. 1202-1210
-
-
Griswold, M.A.1
Jakob, P.M.2
Heidemann, R.M.3
Nittka, M.4
Jellus, V.5
Wang, J.6
|