메뉴 건너뛰기




Volumn 29, Issue 4, 2009, Pages 987-993

High-resolution diffusion tensor imaging with inner field-of-view EPI

Author keywords

Brainstem; Cerebellum; DTI; EPI; Inner field of view; Spinal cord

Indexed keywords

ANISOTROPY; ARTICLE; BRAIN STEM; CERVICAL SPINAL CORD; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; DIFFUSION TENSOR IMAGING; ECHO PLANAR IMAGING; GRAY MATTER; IMAGE QUALITY; IMAGING SYSTEM; MAGNETIC FIELD; NEUROIMAGING; PONS ANGLE; PRIORITY JOURNAL; PYRAMIDAL TRACT; WHITE MATTER; WHOLE BODY MRI;

EID: 65249146101     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21717     Document Type: Article
Times cited : (66)

References (21)
  • 1
    • 36149042452 scopus 로고
    • Multi-planar image formation using NMR spin echoes
    • Mansfield P. Multi-planar image formation using NMR spin echoes. J Phys C 1977;10:349-352.
    • (1977) J Phys C , vol.10 , pp. 349-352
    • Mansfield, P.1
  • 2
    • 0025256879 scopus 로고
    • Echo-planar imaging with asymmetric gradient modulation and inner-volume excitation
    • Feinberg DA, Turner R, Jakab PD, von Kienlin M. Echo-planar imaging with asymmetric gradient modulation and inner-volume excitation. Magn Reson Med 1990;13:162-169.
    • (1990) Magn Reson Med , vol.13 , pp. 162-169
    • Feinberg, D.A.1    Turner, R.2    Jakab, P.D.3    von Kienlin, M.4
  • 3
    • 0036135412 scopus 로고    scopus 로고
    • ADC mapping of the human optic nerve: Increased resolution, coverage, and reliability with CSF-suppressed ZOOM-EPI
    • Wheeler-Kingshott CA, Parker GJ, Symms MR, et al. ADC mapping of the human optic nerve: increased resolution, coverage, and reliability with CSF-suppressed ZOOM-EPI. Magn Reson Med 2002; 47:24-31.
    • (2002) Magn Reson Med , vol.47 , pp. 24-31
    • Wheeler-Kingshott, C.A.1    Parker, G.J.2    Symms, M.R.3
  • 4
    • 28444484999 scopus 로고    scopus 로고
    • High-resolution DTI with 2D interleaved multislice reduced FOV single-shot diffusion-weighted EPI (2D ss-rFOV-DWEPI)
    • Jeong EK, Kim SE, Guo J, Kholmovski EG, Parker DL. High-resolution DTI with 2D interleaved multislice reduced FOV single-shot diffusion-weighted EPI (2D ss-rFOV-DWEPI). Magn Reson Med 2005;54:1575-1579.
    • (2005) Magn Reson Med , vol.54 , pp. 1575-1579
    • Jeong, E.K.1    Kim, S.E.2    Guo, J.3    Kholmovski, E.G.4    Parker, D.L.5
  • 5
    • 0036290659 scopus 로고    scopus 로고
    • Diffusion tensor imaging using single-shot SENSE-EPI
    • Bammer R, Auer M, Keeling SL, et al. Diffusion tensor imaging using single-shot SENSE-EPI. Magn Reson Med 2002;48:128-136.
    • (2002) Magn Reson Med , vol.48 , pp. 128-136
    • Bammer, R.1    Auer, M.2    Keeling, S.L.3
  • 6
    • 0032997647 scopus 로고    scopus 로고
    • Resolution enhancement in single-shot imaging using simultaneous acquisition of spatial harmonics (SMASH)
    • Griswold MA, Jakob PM, Chen Q, et al. Resolution enhancement in single-shot imaging using simultaneous acquisition of spatial harmonics (SMASH). Magn Reson Med 1999;41:1236-1245.
    • (1999) Magn Reson Med , vol.41 , pp. 1236-1245
    • Griswold, M.A.1    Jakob, P.M.2    Chen, Q.3
  • 7
    • 0028145655 scopus 로고
    • Phase errors in multi-shot echo planar imaging
    • Feinberg DA, Oshio K. Phase errors in multi-shot echo planar imaging. Magn Reson Med 1994;32:535-539.
    • (1994) Magn Reson Med , vol.32 , pp. 535-539
    • Feinberg, D.A.1    Oshio, K.2
  • 8
    • 0347361501 scopus 로고
    • Two-dimensional spatially selective spin inversion and spin-echo refocusing with a single nuclear magnetic resonance pulse
    • Bottomley PA, Hardy CJ. Two-dimensional spatially selective spin inversion and spin-echo refocusing with a single nuclear magnetic resonance pulse. J Appl Phys 1987;62:4284-4290.
    • (1987) J Appl Phys , vol.62 , pp. 4284-4290
    • Bottomley, P.A.1    Hardy, C.J.2
  • 9
    • 0036260582 scopus 로고    scopus 로고
    • Two-dimensional spatially selective RF excitation pulses in echo-planar imaging
    • Rieseberg S, Frahm J, Finsterbusch J. Two-dimensional spatially selective RF excitation pulses in echo-planar imaging. Magn Reson Med 2002;47:1186-1193.
    • (2002) Magn Reson Med , vol.47 , pp. 1186-1193
    • Rieseberg, S.1    Frahm, J.2    Finsterbusch, J.3
  • 11
    • 45149145242 scopus 로고
    • A k-space analysis of small-tip- angle excitations
    • Pauly J, Nishimura D, Macovski A. A k-space analysis of small-tip- angle excitations. J Magn Reson 1989;81:43-56.
    • (1989) J Magn Reson , vol.81 , pp. 43-56
    • Pauly, J.1    Nishimura, D.2    Macovski, A.3
  • 12
    • 0000768763 scopus 로고
    • A linear class of large-tip-angle selective excitation pulses
    • Pauly J, Nishimura D, Macovski A. A linear class of large-tip-angle selective excitation pulses. J Magn Reson 1989;82:571-587.
    • (1989) J Magn Reson , vol.82 , pp. 571-587
    • Pauly, J.1    Nishimura, D.2    Macovski, A.3
  • 13
    • 62649150156 scopus 로고    scopus 로고
    • Eddy-current-compensated diffusion weighting with a single refocusing RF pulse. Magn Reson Med
    • Iin press, DOI 10.1002/mrm.21899
    • Finsterbusch J. Eddy-current-compensated diffusion weighting with a single refocusing RF pulse. Magn Reson Med 2009 Iin press); DOI 10.1002/mrm.21899.
    • (2009)
    • Finsterbusch, J.1
  • 14
    • 46149135128 scopus 로고    scopus 로고
    • Haase A, Frahm J, Matthaei D, Hanicke W, Merboldt KD. FLASH imaging. Rapid NMR imaging using low flip-angle pulses. J Magn Reson 1986;67:258-266.
    • Haase A, Frahm J, Matthaei D, Hanicke W, Merboldt KD. FLASH imaging. Rapid NMR imaging using low flip-angle pulses. J Magn Reson 1986;67:258-266.
  • 15
    • 32844475579 scopus 로고    scopus 로고
    • Non-invasive monitoring of renal oxygenation using BOLD-MRI: A reproducibility study
    • Simon-Zoula SC, Hofmann L, Giger A, et al. Non-invasive monitoring of renal oxygenation using BOLD-MRI: a reproducibility study. NMR Biomed 2006;19:84-89.
    • (2006) NMR Biomed , vol.19 , pp. 84-89
    • Simon-Zoula, S.C.1    Hofmann, L.2    Giger, A.3
  • 16
    • 57849153896 scopus 로고    scopus 로고
    • Normal regional fractional anisotropy and apparent diffusion coefficient of the brain measured ona3TMR scanner
    • Lee CEC, Danielian LE, Thomasson D, Baker EH. Normal regional fractional anisotropy and apparent diffusion coefficient of the brain measured ona3TMR scanner. Neuroradiology 2009;51:3-9.
    • (2009) Neuroradiology , vol.51 , pp. 3-9
    • Lee, C.E.C.1    Danielian, L.E.2    Thomasson, D.3    Baker, E.H.4
  • 17
    • 34848915088 scopus 로고    scopus 로고
    • Anatomical parcellation of the brainstem and cerebellar white matter: A preliminary probabilistic tractogra- phy study at 3 T
    • Habas C, Cabanis EA. Anatomical parcellation of the brainstem and cerebellar white matter: a preliminary probabilistic tractogra- phy study at 3 T. Neuroradiology 2007;49:849-863.
    • (2007) Neuroradiology , vol.49 , pp. 849-863
    • Habas, C.1    Cabanis, E.A.2
  • 18
    • 0036331289 scopus 로고    scopus 로고
    • Investigating cervical spinal cord structure using axial diffusion tensor imaging
    • Wheeler-Kingshott CAM, Hickmana SJ, Parker GJM, et al. Investigating cervical spinal cord structure using axial diffusion tensor imaging. Neuroimage 2002;16:93-102.
    • (2002) Neuroimage , vol.16 , pp. 93-102
    • Wheeler-Kingshott, C.A.M.1    Hickmana, S.J.2    Parker, G.J.M.3
  • 19
    • 49749137015 scopus 로고    scopus 로고
    • Diffusion tensor MR imaging of the neurologically intact human spinal cord
    • Ellingson BM, Ulmer JL, Kurpad SN, Schmit BD. Diffusion tensor MR imaging of the neurologically intact human spinal cord. Am J Neuroradiol 2008;29:1279-1284.
    • (2008) Am J Neuroradiol , vol.29 , pp. 1279-1284
    • Ellingson, B.M.1    Ulmer, J.L.2    Kurpad, S.N.3    Schmit, B.D.4
  • 20
    • 42949179425 scopus 로고    scopus 로고
    • A tracking-based diffusion tensor imaging segmentation method for the detection of diffusion-related changes of the cervical spinal cord with aging
    • Van Hecke W, Leemans A, Sijbers J, Vandervliet E, Van Goethem J, Parizel PM. A tracking-based diffusion tensor imaging segmentation method for the detection of diffusion-related changes of the cervical spinal cord with aging. J Magn Reson Imaging 2008;27: 978-991.
    • (2008) J Magn Reson Imaging , vol.27 , pp. 978-991
    • Van Hecke, W.1    Leemans, A.2    Sijbers, J.3    Vandervliet, E.4    Van Goethem, J.5    Parizel, P.M.6
  • 21
    • 40449102167 scopus 로고    scopus 로고
    • Water diffusion anisotropy in white and gray matter of the human spinal cord
    • Rossi C, Boss A, Steidle G, et al. Water diffusion anisotropy in white and gray matter of the human spinal cord. J Magn Reson Imaging 2008;27:476-482.
    • (2008) J Magn Reson Imaging , vol.27 , pp. 476-482
    • Rossi, C.1    Boss, A.2    Steidle, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.