메뉴 건너뛰기




Volumn 35, Issue 4, 2012, Pages 984-992

Improving the performance of diffusion-weighted inner field-of-view echo-planar imaging based on 2D-Selective radiofrequency excitations by tilting the excitation plane

Author keywords

2D selective RF excitation; diffusion tensor; EPI; high resolution; inner field of view; spinal cord

Indexed keywords

ARTICLE; CONTROLLED STUDY; DIFFUSION WEIGHTED IMAGING; ECHO PLANAR IMAGING; HUMAN; PRIORITY JOURNAL; RADIOFREQUENCY; SPINAL CORD; TILTING; WHOLE BODY MRI;

EID: 84858722466     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.23522     Document Type: Article
Times cited : (40)

References (16)
  • 1
    • 36149042452 scopus 로고
    • Multi-planar image formation using NMR spin echoes
    • Mansfield P,. Multi-planar image formation using NMR spin echoes. J Phys C 1977; 10: 349-352.
    • (1977) J Phys C , vol.10 , pp. 349-352
    • Mansfield, P.1
  • 2
    • 0025256879 scopus 로고
    • Echo-planar imaging with asymmetric gradient modulation and inner-volume excitation
    • Feinberg DA, Turner R, Jakab PD, von Kienlin M,. Echo-planar imaging with asymmetric gradient modulation and inner-volume excitation. Magn Reson Med 1990; 13: 162-169.
    • (1990) Magn Reson Med , vol.13 , pp. 162-169
    • Feinberg, D.A.1    Turner, R.2    Jakab, P.D.3    Von Kienlin, M.4
  • 3
    • 28444484999 scopus 로고    scopus 로고
    • High-resolution DTI with 2D interleaved multislice reduced FOV single-shot diffusion-weighted EPI (2D ss-rFOV-DWEPI)
    • Jeong EK, Kim SE, Guo J, Kholmovski EG, Parker DL,. High-resolution DTI with 2D interleaved multislice reduced FOV single-shot diffusion-weighted EPI (2D ss-rFOV-DWEPI). Magn Reson Med 2005; 54: 1575-1579.
    • (2005) Magn Reson Med , vol.54 , pp. 1575-1579
    • Jeong, E.K.1    Kim, S.E.2    Guo, J.3    Kholmovski, E.G.4    Parker, D.L.5
  • 4
    • 0036135412 scopus 로고    scopus 로고
    • ADC mapping of the human optic nerve: Increased resolution, coverage, and reliability with CSF-suppressed ZOOM-EPI
    • Wheeler-Kingshott CA, Parker GJ, Symms MR, et al. ADC mapping of the human optic nerve: increased resolution, coverage, and reliability with CSF-suppressed ZOOM-EPI. Magn Reson Med 2002; 47: 24-31.
    • (2002) Magn Reson Med , vol.47 , pp. 24-31
    • Wheeler-Kingshott, C.A.1    Parker, G.J.2    Symms, M.R.3
  • 5
    • 0347361501 scopus 로고
    • Two-dimensional spatially selective spin inversion and spin-echo refocusing with a single nuclear magnetic resonance pulse
    • Bottomley PA, Hardy CJ,. Two-dimensional spatially selective spin inversion and spin-echo refocusing with a single nuclear magnetic resonance pulse. J Appl Phys 1987; 62: 4284-4290.
    • (1987) J Appl Phys , vol.62 , pp. 4284-4290
    • Bottomley, P.A.1    Hardy, C.J.2
  • 6
    • 45149145242 scopus 로고
    • A k-space analysis of small-tip-angle excitations
    • Pauly J, Nishimura D, Macovski A,. A k-space analysis of small-tip-angle excitations. J Magn Reson 1989; 81: 43-56.
    • (1989) J Magn Reson , vol.81 , pp. 43-56
    • Pauly, J.1    Nishimura, D.2    MacOvski, A.3
  • 7
    • 0000768763 scopus 로고
    • A linear class of large-tip-angle selective excitation pulses
    • Pauly J, Nishimura D, Macovski A,. A linear class of large-tip-angle selective excitation pulses. J Magn Reson 1989; 82: 571-587.
    • (1989) J Magn Reson , vol.82 , pp. 571-587
    • Pauly, J.1    Nishimura, D.2    MacOvski, A.3
  • 8
    • 0036260582 scopus 로고    scopus 로고
    • Two-dimensional spatially selective RF excitation pulses in echo-planar imaging
    • Rieseberg S, Frahm J, Finsterbusch J,. Two-dimensional spatially selective RF excitation pulses in echo-planar imaging. Magn Reson Med 2002; 47: 1186-1193.
    • (2002) Magn Reson Med , vol.47 , pp. 1186-1193
    • Rieseberg, S.1    Frahm, J.2    Finsterbusch, J.3
  • 10
    • 65249146101 scopus 로고    scopus 로고
    • High-resolution diffusion tensor imaging with inner field-of-view EPI
    • Finsterbusch J,. High-resolution diffusion tensor imaging with inner field-of-view EPI. J Magn Reson Imaging 2009; 29: 987-993.
    • (2009) J Magn Reson Imaging , vol.29 , pp. 987-993
    • Finsterbusch, J.1
  • 11
    • 77952863450 scopus 로고    scopus 로고
    • Fast-spin-echo imaging of inner fields-of-view with 2D-selective RF excitations
    • Finsterbusch J,. Fast-spin-echo imaging of inner fields-of-view with 2D-selective RF excitations. J Magn Reson Imaging 2010; 31: 1530-1537.
    • (2010) J Magn Reson Imaging , vol.31 , pp. 1530-1537
    • Finsterbusch, J.1
  • 14
    • 62649150156 scopus 로고    scopus 로고
    • Eddy-current-compensated diffusion weighting with a single refocusing RF pulse
    • Finsterbusch J,. Eddy-current-compensated diffusion weighting with a single refocusing RF pulse. Magn Reson Med 2009; 61: 748-754.
    • (2009) Magn Reson Med , vol.61 , pp. 748-754
    • Finsterbusch, J.1
  • 16
    • 32844475579 scopus 로고    scopus 로고
    • Non-invasive monitoring of renal oxygenation using BOLD-MRI: A reproducibility study
    • Simon-Zoula SC, Hofmann L, Giger A, et al. Non-invasive monitoring of renal oxygenation using BOLD-MRI: a reproducibility study. NMR Biomed 2006; 19: 84-89.
    • (2006) NMR Biomed , vol.19 , pp. 84-89
    • Simon-Zoula, S.C.1    Hofmann, L.2    Giger, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.