1
-
-
34547636880
-
Technology Insight: Future neuroprosthetic therapies for disorders of the nervous system
-
DOI 10.1038/ncpneuro0556, PII NCPNEURO0556
-
R. A. Normann, "Technology insight: Future neuroprosthetic therapies for disorders of the nervous system," Nat. Clin. Pract. Neurol., vol. 3, pp. 444-452, 2007. (Pubitemid 47202501)
-
(2007)
Nature Clinical Practice Neurology
, vol.3
, Issue.8
, pp. 444-452
-
-
Normann, R.A.1
-
2
-
-
27744443832
-
Implantable biomedical microsystems for neural prostheses
-
DOI 10.1109/MEMB.2005.1511501
-
T. Stieglitz, M. Schuettler, and K. P. Koch, "Implantable biomedical microsystems for neural prostheses," Eng. Med. Biol. Mag., vol. 24, pp. 58-65, 2005. (Pubitemid 41633413)
-
(2005)
IEEE Engineering in Medicine and Biology Magazine
, vol.24
, Issue.5
, pp. 58-65
-
-
Stieglitz, T.1
Schuettler, M.2
Koch, K.P.3
-
3
-
-
35648932395
-
Implantablemicroscale neural interfaces
-
K. C. Cheung, "Implantablemicroscale neural interfaces," Biomed.Microdevices, vol. 9, pp. 923-938, 2007.
-
(2007)
Biomed.Microdevices
, vol.9
, pp. 923-938
-
-
Cheung, K.C.1
-
4
-
-
40949122405
-
Demonstration of cortical recording using novel flexible polymer neural probes
-
DOI 10.1016/j.sna.2007.07.027, PII S092442470700564X
-
A.Mercanzini, K. Cheung,D.L.Buhl,M. Boers, A.Maillard, P.Colin, J. C. Bensadoun, A. Bertsch, and P. Renaud, "Demonstration of cortical recording using novel flexible polymer neural probes," Sens. Actuators A, Phys., vol. 143, pp. 90-96, 2008. (Pubitemid 351417366)
-
(2008)
Sensors and Actuators, A: Physical
, vol.143
, Issue.1
, pp. 90-96
-
-
Mercanzini, A.1
Cheung, K.2
Buhl, D.L.3
Boers, M.4
Maillard, A.5
Colin, P.6
Bensadoun, J.-C.7
Bertsch, A.8
Renaud, P.9
-
5
-
-
11144355852
-
Large-scale recording of neuronal ensembles
-
DOI 10.1038/nn1233
-
G. Buzsaki, "Large-scale recording of neuronal ensembles," Nature Neurosci., vol. 7, pp. 446-451, 2004. (Pubitemid 38544574)
-
(2004)
Nature Neuroscience
, vol.7
, Issue.5
, pp. 446-451
-
-
Buzsaki, G.1
-
6
-
-
27744455544
-
Silicon microsystems for neuroscience and neural prostheses
-
DOI 10.1109/MEMB.2005.1511497
-
K. D. Wise, "Silicon microsystems for neuroscience and neural prostheses," IEEE Eng. Med. Biol.Mag., vol. 24, no. 5, pp. 22-29, Sep./Oct. 2005. (Pubitemid 41633409)
-
(2005)
IEEE Engineering in Medicine and Biology Magazine
, vol.24
, Issue.5
, pp. 22-29
-
-
Wise, K.D.1
-
7
-
-
0034884441
-
Single-unit neural recording with active microelectrode arrays
-
DOI 10.1109/10.936367, PII S0018929401061584
-
Q. Bai and K. D. Wise, "Single-unit neural recording with active microelectrode arrays," IEEE Trans. Biomed. Eng., vol. 48, no. 8, pp. 911-920, Aug. 2001. (Pubitemid 32703043)
-
(2001)
IEEE Transactions on Biomedical Engineering
, vol.48
, Issue.8
, pp. 911-920
-
-
Bai, Q.1
Wise, K.D.2
-
8
-
-
70449510376
-
Influence of the number and location of recording contacts on the selectivity of a nerve cuff electrode
-
Oct
-
J.Zariffa, M. K. Nagai, Z. J.Daskalakis, andM. R. Popovic, "Influence of the number and location of recording contacts on the selectivity of a nerve cuff electrode," IEEE Trans. Neural Syst. Rehabil. Eng., vol. 17, no. 5, pp. 420-427, Oct. 2009.
-
(2009)
IEEE Trans. Neural Syst. Rehabil. Eng.
, vol.17
, Issue.5
, pp. 420-427
-
-
Zariffa, J.1
Nagai, M.K.2
Daskalakis, Z.J.3
Popovic, M.R.4
-
9
-
-
18744384648
-
Parylene flexible neural probes integrated with microfluidic channels
-
DOI 10.1039/b417497f
-
S. Takeuchi, D. Ziegler, Y. Yoshida, K. Mabuchi, and T. Suzuki, "Parylene flexible neural probes integrated with microfluidic channels," Lab Chip, vol. 5, pp. 519-523, 2005. (Pubitemid 40676818)
-
(2005)
Lab on a Chip - Miniaturisation for Chemistry and Biology
, vol.5
, Issue.5
, pp. 519-523
-
-
Takeuchi, S.1
Ziegler, D.2
Yoshida, Y.3
Mabuchi, K.4
Suzuki, T.5
-
10
-
-
77957125682
-
Highly sensitive flexible pressure sensors withmicrostructured rubber dielectric layers
-
S. C. B. Mannsfeld, B. C.-K. Tee, R. M. Stoltenberg, C. V. H.-H. Chen, S. Barman, B.V.O.Muir, A. N. Sokolov, C. Reese, and Z. Bao, "Highly sensitive flexible pressure sensors withmicrostructured rubber dielectric layers," Nature Mater., vol. 9, pp. 859-864, 2010.
-
(2010)
Nature Mater.
, vol.9
, pp. 859-864
-
-
Mannsfeld, S.C.B.1
Tee, B.C.-K.2
Stoltenberg, R.M.3
Chen, C.V.H.-H.4
Barman, S.5
Muir, B.V.O.6
Sokolov, A.N.7
Reese, C.8
Bao, Z.9
-
11
-
-
77950994664
-
PDMS-based conformable microelectrode arrays with selectable novel 3-D microelectrode geometries for surface stimulation and recording
-
Minneapolis, MN, Sep. 2-6
-
L. Guo and S. P. DeWeerth, "PDMS-based conformable microelectrode arrays with selectable novel 3-D microelectrode geometries for surface stimulation and recording," in Int. Conf. IEEE Eng. Med. Biol. Soc., Minneapolis, MN, Sep. 2-6, 2009, pp. 1623-1626.
-
(2009)
Int. Conf. IEEE Eng. Med. Biol. Soc.
, pp. 1623-1626
-
-
Guo, L.1
Deweerth, S.P.2
-
12
-
-
0033988843
-
Fabrication of microfluidic systems in poly(dimethylsiloxane)
-
J. C. McDonald, D. C. Anderson, D. T. Chiu, H. Wu, O. J. A. Schueller, and G. M.Whitesides, "Fabrication of microfluidic systems in poly(dimethylsiloxane)," Electrophoresis, vol. 21, pp. 27-40, 2000. (Pubitemid 30032694)
-
(2000)
Electrophoresis
, vol.21
, Issue.1
, pp. 27-40
-
-
McDonald, J.C.1
Duffy, D.C.2
Anderson, J.R.3
Chiu, D.T.4
Wu, H.5
Schueller, O.J.A.6
Whitesides, G.M.7
-
13
-
-
79751536610
-
First long-term in vivo study on subdurally implanted micro-ECoG electrodes, manufactured with a novel laser technology
-
C. Henle, M. Raab, J. G. Cordeiro, S. Doostkam, A. Schulze-Bonhage, T. Stieglitz, and J. Rickert, "First long-term in vivo study on subdurally implanted micro-ECoG electrodes, manufactured with a novel laser technology," Biomed. Microdevices, vol. 13, pp. 59-68, 2011.
-
(2011)
Biomed. Microdevices
, vol.13
, pp. 59-68
-
-
Henle, C.1
Raab, M.2
Cordeiro, J.G.3
Doostkam, S.4
Schulze-Bonhage, A.5
Stieglitz, T.6
Rickert, J.7
-
14
-
-
0035679713
-
Modification of polysiloxane polymers for biomedical applications: A review
-
DOI 10.1002/pi.783
-
F. Abbasi, H. A. Mirzadeh, and A.-A. A. Katbab, "Modification of polysiloxane polymers for biomedical applications: A review," Polymer Int., vol. 50, no. 6, pp. 1279-1287, 2001. (Pubitemid 34039540)
-
(2001)
Polymer International
, vol.50
, Issue.12
, pp. 1279-1287
-
-
Abbasi, F.1
Mirzadeh, H.2
Katbab, A.-A.3
-
15
-
-
77957788893
-
Flexible and stretchable micro-electrodes for in vitro and in vivo neural interfaces
-
S. P. Lacour, S. Benmerah, E. Tarte, J. FitzGerald, J. Serra, S. McMahon, J. Fawcett, O. Graudejus, Z. Yu, and B. Morrison, III, "Flexible and stretchable micro-electrodes for in vitro and in vivo neural interfaces," Med. Biol. Eng. Comput., vol. 48, pp. 945-954, 2010.
-
(2010)
Med. Biol. Eng. Comput.
, vol.48
, pp. 945-954
-
-
Lacour, S.P.1
Benmerah, S.2
Tarte, E.3
Fitzgerald, J.4
Serra, J.5
McMahon, S.6
Fawcett, J.7
Graudejus, O.8
Yu, Z.9
Morrison Iii, B.10
-
16
-
-
0031224250
-
The mechanical properties of the rubber elastic polymer polydimethylsiloxane for sensor applications
-
PII S0960131797832561
-
J. C. Lottersy,W.Olthuis, P.H.Veltink, and P. Bergveld, "Themechanical properties of the rubber elastic polymer polydimethylsiloxane for sensor applications," J. Micromechan. Microeng., vol. 7, pp. 145-147, 1997. (Pubitemid 127607064)
-
(1997)
Journal of Micromechanics and Microengineering
, vol.7
, Issue.3
, pp. 145-147
-
-
Lotters, J.C.1
Olthuis, W.2
Veltink, P.H.3
Bergveld, P.4
-
17
-
-
33846999007
-
Characterization and resolution of evaporation- mediated osmolality shifts that constrain microfluidic cell culture in poly(dimethylsiloxane) devices
-
S. H. Yun, L. M. Cabrera, J. W. Song, N. Futai, Y. C. Tung, G. D. Smith, and S. Takayama, "Characterization and resolution of evaporation- mediated osmolality shifts that constrain microfluidic cell culture in poly(dimethylsiloxane) devices," Anal. Chem., vol. 79, no. 3, pp. 1126-1134, 2007.
-
(2007)
Anal. Chem.
, vol.79
, Issue.3
, pp. 1126-1134
-
-
Yun, S.H.1
Cabrera, L.M.2
Song, J.W.3
Futai, N.4
Tung, Y.C.5
Smith, G.D.6
Takayama, S.7
-
18
-
-
34248210771
-
When PDMS isn't the best
-
R. Mukhopadhyay, "When PDMS isn't the best," Anal. Chem., vol. 79, no. 9, pp. 3249-3253, 2007. (Pubitemid 46717155)
-
(2007)
Analytical Chemistry
, vol.79
, Issue.9
, pp. 3249-3253
-
-
Mukhopadhyay, R.1
-
19
-
-
0029657196
-
The behaviour of water in poly(dimethylsiloxane)
-
DOI 10.1016/0376-7388(95)00229-4
-
J. M. Watson and M. G. Baron, "The behaviour of water in poly(dimethylsiloxane)," J. Membrane Sci., vol. 110, no. 1, pp. 47-57, 1996. (Pubitemid 26064134)
-
(1996)
Journal of Membrane Science
, vol.110
, Issue.1
, pp. 47-57
-
-
Watson, J.M.1
Baron, M.G.2
-
20
-
-
0028764265
-
Sorption, diffusion and vapor permeation of various penetrants through dense poly(dimethylsiloxane) membranes: A transport analysis
-
E. Favre, P. Schaetzel, Q. T. Nguygen, R. Clément, and J. Néel, "Sorption, diffusion and vapor permeation of various penetrants through dense poly(dimethylsiloxane) membranes: A transport analysis," J. Membrane Sci., vol. 92, no. 2, pp. 169-184, 1994.
-
(1994)
J. Membrane Sci.
, vol.92
, Issue.2
, pp. 169-184
-
-
Favre, E.1
Schaetzel, P.2
Nguygen, Q.T.3
Clément, R.4
Néel, J.5
-
21
-
-
33344461572
-
Paclitaxel releasing films consisting of poly(vinyl alcohol)-graft- poly(lactide-co-glycolide) and their potential as biodegradable stent coatings
-
DOI 10.1016/j.jconrel.2005.12.012, PII S0168365905007273
-
U. Westedt, M. Wittmar, M. Hellwig, P. Hanefeld, A. Greiner, A. K. Shaper, and T. Kissel, "Paclitaxel releasing films consisting of poly(vinyl alcohol)-graft- poly(lactide-co-glycolide) and their potential as biodegradable stent coatings," J. Controlled Release, vol. 111, no. 1-2, pp. 235-246, 2006. (Pubitemid 43290013)
-
(2006)
Journal of Controlled Release
, vol.111
, Issue.1-2
, pp. 235-246
-
-
Westedt, U.1
Wittmar, M.2
Hellwig, M.3
Hanefeld, P.4
Greiner, A.5
Schaper, A.K.6
Kissel, T.7
-
22
-
-
0013535947
-
Transient and steady-state water vapor permeation through polymer films
-
W. H. Hubbell and Z. A. Munir, "Transient and steady-state water vapor permeation through polymer films," J. Polym. Sci., vol. 13, pp. 493-507, 1975.
-
(1975)
J. Polym. Sci.
, vol.13
, pp. 493-507
-
-
Hubbell, W.H.1
Munir, Z.A.2
-
23
-
-
60549100010
-
Encapsulation of an integrated neural interface device with parylene C
-
Jan
-
J. Hsu, L. Rieth, R. A. Normann, P. Tathireddy, and F. Solzbacher, "Encapsulation of an integrated neural interface device with parylene C," IEEE Trans. Biomed. Eng., vol. 56, no. 1, pp. 23-29, Jan. 2009.
-
(2009)
IEEE Trans. Biomed. Eng.
, vol.56
, Issue.1
, pp. 23-29
-
-
Hsu, J.1
Rieth, L.2
Normann, R.A.3
Tathireddy, P.4
Solzbacher, F.5
-
24
-
-
84908014903
-
Standard test methods for measuring adhesion by tape test
-
Standard test methods for measuring adhesion by tape test 2009,ASTM Int. D3359-09.
-
(2009)
ASTM Int.
-
-
-
26
-
-
79952677945
-
Electric field strength and focality in electroconvulsive therapy andmagnetic seizure therapy: A finite element simulation study
-
Z.-D. Deng, S. H. Lisanby, and A. V. Peterchev, "Electric field strength and focality in electroconvulsive therapy andmagnetic seizure therapy: A finite element simulation study," J. Neural Eng., vol. 8, no. 1, 2011, 016007.
-
(2011)
J. Neural Eng.
, vol.8
, Issue.1
, pp. 016007
-
-
Deng, Z.-D.1
Lisanby, S.H.2
Peterchev, A.V.3
-
27
-
-
4143056824
-
Three-dimensional head model simulation of transcranial magnetic stimulation
-
DOI 10.1109/TBME.2004.827925
-
T. A. Wagner, M. Zahn, A. J. Grodzinsky, and A. Pascual-Leone, "Three-dimensional head model simulation of transcranial magnetic stimulation," IEEE Trans. Biomed. Eng., vol. 51, no. 9, pp. 1586-1598, Sep. 2004. (Pubitemid 39100232)
-
(2004)
IEEE Transactions on Biomedical Engineering
, vol.51
, Issue.9
, pp. 1586-1598
-
-
Wagner, T.A.1
Zahn, M.2
Grodzinsky, A.J.3
Pascual-Leone, A.4
-
29
-
-
0031773556
-
Functional mapping of human sensorimotor cortex with electrocorticographic spectral analysis: I. Alpha and beta event-related desynchronization
-
N. E. Crone, D. L.Miglioretti, B. Gordon, J.M. Sieracki, M. T.Wilson, S. Uematsu, and R. P. Lesser, "Functional mapping of human sensorimotor cortex with electrocorticographic spectral analysis: I. Alpha and beta event-related desynchronization," Brain, vol. 121, no. 12, pp. 2271-2299, 1998. (Pubitemid 28552466)
-
(1998)
Brain
, vol.121
, Issue.12
, pp. 2271-2299
-
-
Crone, N.E.1
Miglioretti, D.L.2
Gordon, B.3
Sieracki, J.M.4
Wilson, M.T.5
Uematsu, S.6
Lesser, R.P.7
-
30
-
-
0033981255
-
Spatial spectral analysis of human electrocorticograms including the alpha and gamma bands
-
DOI 10.1016/S0165-0270(99)00160-0, PII S0165027099001600
-
W. J. Freeman,L. J.Rogers, M. D. Holmes, andD. L. Silbergeld, "Spatial spectral analysis of human electrocorticograms including the alpha and gamma bands," J. Neurosci. Methods, vol. 95, no. 2, pp. 111-121, 2000. (Pubitemid 30089603)
-
(2000)
Journal of Neuroscience Methods
, vol.95
, Issue.2
, pp. 111-121
-
-
Freeman, W.J.1
Rogers, L.J.2
Holmes, M.D.3
Silbergeld, D.L.4
-
31
-
-
0032954378
-
Enhanced gamma (30-150 Hz) frequency in the human medial temporal lobe
-
N.Hirai,S.Uchida, T.Maehara, Y. Okubo, andH. Shimizu, "Enhanced gamma (30-150 Hz) frequency in the human medial temporal lobe," Neuroscience, vol. 90, no. 4, pp. 1149-1155.
-
Neuroscience
, vol.90
, Issue.4
, pp. 1149-1155
-
-
Hirai, N.1
Uchida, S.2
Maehara, T.3
Okubo, Y.4
Shimizu, H.5
-
32
-
-
0028898835
-
The linear and non-linear electrical properties of the electrode-electrolyte interface
-
E. T. McAdams, A. Lackermeier, J. A. McLaughlin, D. Macken, and J. Jossinet, "The linear and non-linear electrical properties of the electrode-electrolyte interface," Biosensors Bioelectron., vol. 10, pp. 67-74, 1995.
-
(1995)
Biosensors Bioelectron.
, vol.10
, pp. 67-74
-
-
McAdams, E.T.1
Lackermeier, A.2
McLaughlin, J.A.3
Macken, D.4
Jossinet, J.5
-
33
-
-
0021500471
-
Analysis of electrode impedances complicated by the presence of a constant phase element
-
G. J. Brug, A. L. G. Van Den Eeden, M. Sluyters-Rehbach, and J. H. Sluyters, "The analysis of electrode impedances complicated by the presence of a constant phase element," J. Electroanalyt. Chem., vol. 176, no. 1-2, pp. 275-295, 1984. (Pubitemid 14642402)
-
(1984)
Journal of electroanalytical chemistry and interfacial electrochemistry
, vol.176
, Issue.1-2
, pp. 275-295
-
-
Brug, G.J.1
Van Den Eeden, A.L.G.2
Sluyters-Rehbach, M.3
Sluyters, J.H.4
-
34
-
-
21844466991
-
Impedance characterization and modeling of electrodes for biomedical applications
-
DOI 10.1109/TBME.2005.847523
-
W. Franks, I. Schenker, P. Schmutz, and A. Hierlemann, "Impedance characterization and modeling electrodes for biomedical applications," IEEE Trans. Biomed. Eng., vol. 52, no. 7, pp. 1295-1302, Jul. 2005. (Pubitemid 40961380)
-
(2005)
IEEE Transactions on Biomedical Engineering
, vol.52
, Issue.7
, pp. 1295-1302
-
-
Franks, W.1
Schenker, I.2
Schmutz, P.3
Hierlemann, A.4
-
35
-
-
38349059795
-
Experimental and theoretical characterization of implantable neural microelectrodes modified with conducting polymer nanotubes
-
M. R. Abidian and D. C. Martin, "Experimental and theoretical characterization of implantable neural microelectrodes modified with conducting polymer nanotubes," Biomaterials, vol. 29, no. 9, pp. 1273-1283, 2008.
-
(2008)
Biomaterials
, vol.29
, Issue.9
, pp. 1273-1283
-
-
Abidian, M.R.1
Martin, D.C.2
-
36
-
-
0031199795
-
Electrochemical test methods for evaluating organic coatings on metals: An update. Part III: Multiple test parameter measurements
-
PII S0300944097000994
-
J. N. Murray, "Electrochemical test methods for evaluating organic coatings on metals: An update. Part III: Multiple test parameter measurement," Progress Organic Coat., vol. 31, no. 4, pp. 375-391, 1997. (Pubitemid 127433039)
-
(1997)
Progress in Organic Coatings
, vol.31
, Issue.4
, pp. 375-391
-
-
Murray, J.N.1
-
37
-
-
33751537196
-
Substitution of the constant phase element by Warburg impedance for protective coatings
-
DOI 10.1016/j.corsci.2006.06.027, PII S0010938X06002332
-
S. Skale, V. Dolecek, and M. Slemnik, "Substitution of the constant phase element by Warburg impedance for protective coatings," Corrosion Sci., vol. 49, no. 3, pp. 1045-1055, 2007. (Pubitemid 44838595)
-
(2007)
Corrosion Science
, vol.49
, Issue.3
, pp. 1045-1055
-
-
Skale, S.1
Dolecek, V.2
Slemnik, M.3
-
38
-
-
77956646020
-
Controlling the morphology of gold films on poly (dimethylsiloxane)
-
O. Graudejus, P. Görrn, and W.Wagner, "Controlling the morphology of gold films on poly (dimethylsiloxane)," ACS Appl.Mater. Interfaces, vol. 2, no. 7, pp. 1927-1933, 2010.
-
(2010)
ACS Appl.Mater. Interfaces
, vol.2
, Issue.7
, pp. 1927-1933
-
-
Graudejus, O.1
Görrn, P.2
Wagner, W.3
-
39
-
-
67349253596
-
Simulated power spectral density (PSD) of background electrocorticogram (ECoG)
-
W. J. Freeman and J. Zhai, "Simulated power spectral density (PSD) of background electrocorticogram (ECoG)," Cognitive Neurodynam., vol. 3, no. 1, pp. 97-103, 2009.
-
(2009)
Cognitive Neurodynam.
, vol.3
, Issue.1
, pp. 97-103
-
-
Freeman, W.J.1
Zhai, J.2
-
40
-
-
67849132111
-
A MEMS-based flexible multichannel ECoG-electrode array
-
B. Rubehn, C. Bosman, R. Oostenveld, P. Fries, and T. Stieglitz, "A MEMS-based flexible multichannel ECoG-electrode array," J. Neural Eng., vol. 6, no. 3, 2009, 036003.
-
(2009)
J. Neural Eng.
, vol.6
, Issue.3
, pp. 036003
-
-
Rubehn, B.1
Bosman, C.2
Oostenveld, R.3
Fries, P.4
Stieglitz, T.5
-
41
-
-
36949016404
-
Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants
-
DOI 10.1088/1741-2560/4/4/007, PII S174125600752611X
-
J. C.Williams, J. A. Hippensteel, J. Dilgen,W. Shain, and D. R. Kipke, "Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants," J. Neural Eng., vol. 4, no. 4, pp. 410-423, 2007. (Pubitemid 350242918)
-
(2007)
Journal of Neural Engineering
, vol.4
, Issue.4
, pp. 410-423
-
-
Williams, J.C.1
Hippensteel, J.A.2
Dilgen, J.3
Shain, W.4
Kipke, D.R.5
-
42
-
-
79960380366
-
Evaluation of an elastomer based gold microelectrode array for neural recording applications
-
I. R. Minev, D. J. Chew, E. Delivopoulos, J. W. Fawcett, and S. P. Lacour, "Evaluation of an elastomer based gold microelectrode array for neural recording applications," in Proc. 5th Int. IEEE EMBS Conf. Neural Eng., 2011, pp. 482-485.
-
(2011)
Proc. 5th Int. IEEE EMBS Conf. Neural Eng.
, pp. 482-485
-
-
Minev, I.R.1
Chew, D.J.2
Delivopoulos, E.3
Fawcett, J.W.4
Lacour, S.P.5
-
43
-
-
60449109745
-
Integration of Au nanorods with flexible thin-film microelectrode arrays for improved neural interfaces
-
H.-B. Zhou, G. Li, X.-N. Sun, Z.-H. Zhu, Q.-H. Jin, J.-L. Zhao, and Q.-S. Ren, "Integration of Au nanorods with flexible thin-film microelectrode arrays for improved neural interfaces," J. Microelectromechan. Syst., vol. 18, no. 1, pp. 88-96, 2009.
-
(2009)
J. Microelectromechan. Syst.
, vol.18
, Issue.1
, pp. 88-96
-
-
Zhou, H.-B.1
Li, G.2
Sun, X.-N.3
Zhu, Z.-H.4
Jin, Q.-H.5
Zhao, J.-L.6
Ren, Q.-S.7
-
44
-
-
50249084472
-
Neural stimulation and recording electrodes
-
S. F. Cogan, "Neural stimulation and recording electrodes," Annu. Rev. Biomed. Eng., vol. 10, pp. 275-309, 2008.
-
(2008)
Annu. Rev. Biomed. Eng.
, vol.10
, pp. 275-309
-
-
Cogan, S.F.1
-
45
-
-
34047114446
-
Characterization of gold electrodes in phosphate buffered saline solution by impedance and noise measurements for biological applications
-
DOI 10.1109/IEMBS.2006.260406, 4030106, 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06
-
E. T. McAdams, J. Jossinet, R. Subramanian, and R. G. E. McCauley, "Characterization of gold electrodes in phosphate buffered saline solution by impedance and noise measurements for biological applications," in Proc. Annu. Int. Conf. IEEE Eng. Med. Biol., 2006, pp. 4594-4597. (Pubitemid 46520936)
-
(2006)
Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
, pp. 4594-4597
-
-
McAdams, E.T.1
Jossinet, J.2
Subramanian, R.3
McCauley, R.G.E.4
-
46
-
-
12344323809
-
Electrical stimulation of excitable tissue: Design of efficacious and safe protocols
-
DOI 10.1016/j.jneumeth.2004.10.020, PII S0165027004003826
-
D. R. Merrill, M. Bikson, and J. G. R. Jefferys, "Electrical stimulation of excitable tissue: Design of efficacious and safe protocols," J. Neurosci. Methods, vol. 141, no. 2, pp. 171-198, 2005. (Pubitemid 40136531)
-
(2005)
Journal of Neuroscience Methods
, vol.141
, Issue.2
, pp. 171-198
-
-
Merrill, D.R.1
Bikson, M.2
Jefferys, J.G.R.3
-
47
-
-
77749309845
-
Fabrication and characterization of implantable and flexible nerve cuff electrodes with Pt, Ir and IrOx films deposited by RF sputtering
-
S. H. Lee, J. H. Jung, Y. M. Chae, J. F. Suh, and J. Y. Kang, "Fabrication and characterization of implantable and flexible nerve cuff electrodes with Pt, Ir and IrOx films deposited by RF sputtering," J. Micromechan. Microeng., vol. 30, no. 3, 2010, 035015.
-
(2010)
J. Micromechan. Microeng.
, vol.30
, Issue.3
, pp. 035015
-
-
Lee, S.H.1
Jung, J.H.2
Chae, Y.M.3
Suh, J.F.4
Kang, J.Y.5
-
48
-
-
60549083275
-
Effect of sputtering pressure on pulsed-DC sputtered iridium oxide films
-
S. Negi, R. Bhandari, L. Rieth, and F. Solzbacher, "Effect of sputtering pressure on pulsed-DC sputtered iridium oxide films," Sensors Actuators B, Chem., vol. 137, no. 1, pp. 370-378, 2009.
-
(2009)
Sensors Actuators B, Chem.
, vol.137
, Issue.1
, pp. 370-378
-
-
Negi, S.1
Bhandari, R.2
Rieth, L.3
Solzbacher, F.4
|