메뉴 건너뛰기




Volumn , Issue , 2009, Pages 1623-1626

PDMS-based conformable microelectrode arrays with selectable novel 3-D microelectrode geometries for surface stimulation and recording

Author keywords

[No Author keywords available]

Indexed keywords

GEOMETRY; MICROCHANNELS; MICROELECTRODES; POLYDIMETHYLSILOXANE; SILICONES; TISSUE;

EID: 77950994664     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2009.5333446     Document Type: Conference Paper
Times cited : (17)

References (12)
  • 2
    • 33847313677 scopus 로고    scopus 로고
    • Stretchable micro-electrode arrays for dynamic neuronal recording of in vitro mechanically injured brain
    • S. P. Lacour, C. Tsay, S. Wagner, Z. Yu, and B. Morrison, "Stretchable micro-electrode arrays for dynamic neuronal recording of in vitro mechanically injured brain," Proc. of the 4th IEEE Conference on Sensors, pp. 617-620, 2005.
    • (2005) Proc. of the 4th IEEE Conference on Sensors , pp. 617-620
    • Lacour, S.P.1    Tsay, C.2    Wagner, S.3    Yu, Z.4    Morrison, B.5
  • 3
    • 22044438514 scopus 로고    scopus 로고
    • Fabrication of implantable microelectrode arrays by laser cutting of silicone rubber and platinum foil
    • M. Schuettler, S. Stiess, B. V. King, and G. J. Suaning, "Fabrication of implantable microelectrode arrays by laser cutting of silicone rubber and platinum foil," J. Neural Eng., vol.2, pp. S121-S128, 2005.
    • (2005) J. Neural Eng. , vol.2
    • Schuettler, M.1    Stiess, S.2    King, B.V.3    Suaning, G.J.4
  • 4
    • 40449089502 scopus 로고    scopus 로고
    • A lithographically-patterned, elastic multi-electrode array for surface stimulation of the spinal cord
    • April
    • K. W. Meacham, R. J. Giuly, L. Guo, S. Hochman, and S. P. DeWeerth, "A lithographically-patterned, elastic multi-electrode array for surface stimulation of the spinal cord," Biomedical Microdevices, vol.10, no.2, pp. 259-269, April 2008.
    • (2008) Biomedical Microdevices , vol.10 , Issue.2 , pp. 259-269
    • Meacham, K.W.1    Giuly, R.J.2    Guo, L.3    Hochman, S.4    Deweerth, S.P.5
  • 5
    • 0025500717 scopus 로고
    • Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
    • October
    • D. B. McCreery, W. F. Agnew, T. G. Yuen, and L. Bullara, "Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation," IEEE Trans. Biomed. Eng., vol.37, no.10, pp. 996-1001, October 1990.
    • (1990) IEEE Trans. Biomed. Eng. , vol.37 , Issue.10 , pp. 996-1001
    • McCreery, D.B.1    Agnew, W.F.2    Yuen, T.G.3    Bullara, L.4
  • 6
    • 84958237242 scopus 로고
    • Current distribution on a rotating disk below the limiting current
    • December
    • J. Newman, "Current distribution on a rotating disk below the limiting current," J. Electrochem. Soc., vol.113, pp. 1235-1241, December 1966.
    • (1966) J. Electrochem. Soc. , vol.113 , pp. 1235-1241
    • Newman, J.1
  • 7
    • 0023526305 scopus 로고
    • Current density profiles of surface mounted and recessed electrodes for neural prostheses
    • November
    • J. T. Rubinstein, F. A. Spelman, M. Soma, and M. F. Suesserman, "Current density profiles of surface mounted and recessed electrodes for neural prostheses," IEEE Trans. Biomed. Eng., vol.34, no.11, pp. 864-875, November 1987.
    • (1987) IEEE Trans. Biomed. Eng. , vol.34 , Issue.11 , pp. 864-875
    • Rubinstein, J.T.1    Spelman, F.A.2    Soma, M.3    Suesserman, M.F.4
  • 8
    • 0026153583 scopus 로고
    • In vitro measurement and characterization of current density profiles produced by nonrecessed, simple recessed, and radially varying recessed stimulating electrodes
    • May
    • M. F. Suesserman, F. A. Spelman, and J. T. Rubinstein, "In vitro measurement and characterization of current density profiles produced by nonrecessed, simple recessed, and radially varying recessed stimulating electrodes," IEEE Trans. Biomed. Eng., vol.38, no.5, pp. 401-408, May 1991.
    • (1991) IEEE Trans. Biomed. Eng. , vol.38 , Issue.5 , pp. 401-408
    • Suesserman, M.F.1    Spelman, F.A.2    Rubinstein, J.T.3
  • 11
    • 0033230921 scopus 로고    scopus 로고
    • Imaging of nonuniform current density at microelectrodes by electrogenerated chemiluminescence
    • R. G. Maus, E. M. McDonald, and R. M. Wightman, "Imaging of nonuniform current density at microelectrodes by electrogenerated chemiluminescence," Anal. Chem., vol.71, pp. 4944-4950, 1999.
    • (1999) Anal. Chem. , vol.71 , pp. 4944-4950
    • Maus, R.G.1    McDonald, E.M.2    Wightman, R.M.3
  • 12
    • 0003588440 scopus 로고    scopus 로고
    • Imaging microelectrodes with high-frequency electrogenerated chemiluminescence
    • R. M. Wightman, C. L. Curtis, P. A. Flowers, R. G. Maus, and E. M. McDonald, "Imaging microelectrodes with high-frequency electrogenerated chemiluminescence," J. Phys. Chem. B, vol.102, pp. 9991-9996, 1998.
    • (1998) J. Phys. Chem. B , vol.102 , pp. 9991-9996
    • Wightman, R.M.1    Curtis, C.L.2    Flowers, P.A.3    Maus, R.G.4    McDonald, E.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.