메뉴 건너뛰기




Volumn 8, Issue 7, 2013, Pages

Patterned Immobilization of Antibodies within Roll-to-Roll Hot Embossed Polymeric Microfluidic Channels

Author keywords

[No Author keywords available]

Indexed keywords

POLY(METHYL METHACRYLATE); POLYETHYLENEIMINE;

EID: 84880404462     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0068918     Document Type: Article
Times cited : (35)

References (41)
  • 1
    • 0033749295 scopus 로고    scopus 로고
    • Status of point-of-care testing: promise, realities, and possibilities
    • St-Louis P, (2000) Status of point-of-care testing: promise, realities, and possibilities. Clin. Biochem 33: 427-440.
    • (2000) Clin. Biochem , vol.33 , pp. 427-440
    • St-Louis, P.1
  • 2
    • 77952527887 scopus 로고    scopus 로고
    • Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
    • Mark D, Haeberle S, Roth G, von Stetten F, Zengerle R, (2010) Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications. Chemical Society Reviews 39: 1153-1182.
    • (2010) Chemical Society Reviews , vol.39 , pp. 1153-1182
    • Mark, D.1    Haeberle, S.2    Roth, G.3    von Stetten, F.4    Zengerle, R.5
  • 3
    • 21844471002 scopus 로고    scopus 로고
    • Point-of-care immunotesting: Approaching the analytical performance of central laboratory methods
    • Von Lode P, (2005) Point-of-care immunotesting: Approaching the analytical performance of central laboratory methods. Clin Biochem 38: 591-606.
    • (2005) Clin Biochem , vol.38 , pp. 591-606
    • Von Lode, P.1
  • 4
    • 30044450248 scopus 로고    scopus 로고
    • Development of an Enzyme Linked Immunosorbent Assay for the Determination of the Linear Alkylbenzene Sulfonates and Long-Chain Sulfophenyl Carboxylates Using Antibodies Generated by Pseudoheterologous Immunization
    • Ramón-Azcón J, Galve R, Sánchez-Baeza F, Marco MP, (2005) Development of an Enzyme Linked Immunosorbent Assay for the Determination of the Linear Alkylbenzene Sulfonates and Long-Chain Sulfophenyl Carboxylates Using Antibodies Generated by Pseudoheterologous Immunization. Analytical Chemistry 78: 71-81.
    • (2005) Analytical Chemistry , vol.78 , pp. 71-81
    • Ramón-Azcón, J.1    Galve, R.2    Sánchez-Baeza, F.3    Marco, M.P.4
  • 6
    • 84862231072 scopus 로고    scopus 로고
    • Commercialization of microfluidic point-of-care diagnostic devices
    • Chin CD, Linder V, Sia SK, (2012) Commercialization of microfluidic point-of-care diagnostic devices. Lab on a Chip 12: 2118-2134.
    • (2012) Lab on a Chip , vol.12 , pp. 2118-2134
    • Chin, C.D.1    Linder, V.2    Sia, S.K.3
  • 7
    • 57849115714 scopus 로고    scopus 로고
    • Lateral flow (immuno) assay: its strengths, weaknesses, opportunities and threats. A literature survey
    • Posthuma-Trumpie G, Korf J, Amerongen A, (2009) Lateral flow (immuno) assay: its strengths, weaknesses, opportunities and threats. A literature survey. Analytical and Bioanalytical Chemistry 393: 569-582.
    • (2009) Analytical and Bioanalytical Chemistry , vol.393 , pp. 569-582
    • Posthuma-Trumpie, G.1    Korf, J.2    Amerongen, A.3
  • 8
    • 79551486836 scopus 로고    scopus 로고
    • Microfluidic-based biosensors toward point-of-care detection of nucleic acids and proteins
    • Choi S, Goryll M, Sin L, Wong P, Chae J, (2011) Microfluidic-based biosensors toward point-of-care detection of nucleic acids and proteins. Microfluidics and Nanofluidics 10: 231-247.
    • (2011) Microfluidics and Nanofluidics , vol.10 , pp. 231-247
    • Choi, S.1    Goryll, M.2    Sin, L.3    Wong, P.4    Chae, J.5
  • 10
    • 79954414628 scopus 로고    scopus 로고
    • Unconventional Low-Cost Fabrication and Patterning Techniques for Point of Care Diagnostics
    • Sharma H, Nguyen D, Chen A, Lew V, Khine M, (2011) Unconventional Low-Cost Fabrication and Patterning Techniques for Point of Care Diagnostics. Annals of Biomedical Engineering 39: 1313-1327.
    • (2011) Annals of Biomedical Engineering , vol.39 , pp. 1313-1327
    • Sharma, H.1    Nguyen, D.2    Chen, A.3    Lew, V.4    Khine, M.5
  • 12
    • 67649207983 scopus 로고    scopus 로고
    • Hot roller embossing for microfluidics: Process and challenges
    • Ng SH, Wang ZF, (2009) Hot roller embossing for microfluidics: Process and challenges. Microsystem Technologies 15: 1149-1156.
    • (2009) Microsystem Technologies , vol.15 , pp. 1149-1156
    • Ng, S.H.1    Wang, Z.F.2
  • 14
    • 3042819011 scopus 로고    scopus 로고
    • A soft lithographic approach to fabricate patterned microfluidic channels
    • Khademhosseini A, Suh KY, Jon S, Eng G, Yeh J, (2004) A soft lithographic approach to fabricate patterned microfluidic channels. Analytical Chemistry 76: 3675-3681.
    • (2004) Analytical Chemistry , vol.76 , pp. 3675-3681
    • Khademhosseini, A.1    Suh, K.Y.2    Jon, S.3    Eng, G.4    Yeh, J.5
  • 15
    • 84855947968 scopus 로고    scopus 로고
    • Patterning multiplex protein microarrays in a single microfluidic channel
    • Didar TF, Foudeh AM, Tabrizian M, (2012) Patterning multiplex protein microarrays in a single microfluidic channel. Analytical Chemistry 84: 1012-1018.
    • (2012) Analytical Chemistry , vol.84 , pp. 1012-1018
    • Didar, T.F.1    Foudeh, A.M.2    Tabrizian, M.3
  • 16
    • 77956325151 scopus 로고    scopus 로고
    • An integrated micro-electro-fluidic and protein arraying system for parallel analysis of cell responses to controlled microenvironments
    • Yin Z, Tao SC, Cheong R, Zhu H, Levchenko A, (2010) An integrated micro-electro-fluidic and protein arraying system for parallel analysis of cell responses to controlled microenvironments. Integrative Biology 2: 416-423.
    • (2010) Integrative Biology , vol.2 , pp. 416-423
    • Yin, Z.1    Tao, S.C.2    Cheong, R.3    Zhu, H.4    Levchenko, A.5
  • 18
    • 0036202561 scopus 로고    scopus 로고
    • Microchip-based immunoassay system with branching multichannels for simultaneous detection of interferon c
    • Sato K, Yamanaka M, Takahashi H, Tokeshi M, Kimura H, (2002) Microchip-based immunoassay system with branching multichannels for simultaneous detection of interferon c. Electrophoresis 23: 734-739.
    • (2002) Electrophoresis , vol.23 , pp. 734-739
    • Sato, K.1    Yamanaka, M.2    Takahashi, H.3    Tokeshi, M.4    Kimura, H.5
  • 19
    • 72849110297 scopus 로고    scopus 로고
    • Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates
    • Gervais L, Delamarche E, (2009) Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates. Lab on a Chip- Miniaturization for Chemistry and Biology 9: 3330-3337.
    • (2009) Lab on a Chip - Miniaturization for Chemistry and Biology , vol.9 , pp. 3330-3337
    • Gervais, L.1    Delamarche, E.2
  • 20
    • 0036828728 scopus 로고    scopus 로고
    • A microarray immunoassay for simultaneous detection of proteins and bacteria
    • Delehanty JB, Ligler FS, (2002) A microarray immunoassay for simultaneous detection of proteins and bacteria. Analytical Chemistry 74: 5681-5687.
    • (2002) Analytical Chemistry , vol.74 , pp. 5681-5687
    • Delehanty, J.B.1    Ligler, F.S.2
  • 21
    • 84873517464 scopus 로고    scopus 로고
    • Surface functionalized nanofibrillar cellulose (NFC) film as a platform for immunoassays and diagnostics
    • Orelma H, Filpponen I, Johansson LS, Österberg M, Rojas OJ, (2012) Surface functionalized nanofibrillar cellulose (NFC) film as a platform for immunoassays and diagnostics. Biointerphases 7: 1-12.
    • (2012) Biointerphases , vol.7 , pp. 1-12
    • Orelma, H.1    Filpponen, I.2    Johansson, L.S.3    Österberg, M.4    Rojas, O.J.5
  • 22
    • 64349111924 scopus 로고    scopus 로고
    • Piezoelectric inkjet printing of a cross-hatch immunoassay on a disposable nylon membrane
    • Stewart TN, Pierson BE, Aggarwal R, Narayan RJ, (2009) Piezoelectric inkjet printing of a cross-hatch immunoassay on a disposable nylon membrane. BiotechnologyJournal: 4 (2): 206-209.
    • (2009) BiotechnologyJournal , vol.4 , Issue.2 , pp. 206-209
    • Stewart, T.N.1    Pierson, B.E.2    Aggarwal, R.3    Narayan, R.J.4
  • 23
    • 76749124989 scopus 로고    scopus 로고
    • Nanoscale resolution, multicomponent biomolecular arrays generated by aligned printing with parylene peel-off
    • Tan CP, Cipriany BR, Lin DM, Craighead HG, (2010) Nanoscale resolution, multicomponent biomolecular arrays generated by aligned printing with parylene peel-off. Nano Letters 10: 719-725.
    • (2010) Nano Letters , vol.10 , pp. 719-725
    • Tan, C.P.1    Cipriany, B.R.2    Lin, D.M.3    Craighead, H.G.4
  • 24
    • 39549087011 scopus 로고    scopus 로고
    • Demonstration of multi-analyte patterning using piezoelectric inkjet printing of multiple layers
    • Hasenbank MS, Edwards T, Fu E, Garzon R, Kosar TF, et al. (2008) Demonstration of multi-analyte patterning using piezoelectric inkjet printing of multiple layers. Analytica Chimica Acta. 2611(1): 80-88.
    • (2008) Analytica Chimica Acta , vol.2611 , Issue.1 , pp. 80-88
    • Hasenbank, M.S.1    Edwards, T.2    Fu, E.3    Garzon, R.4    Kosar, T.F.5
  • 26
    • 10444263785 scopus 로고    scopus 로고
    • Wettability interpretation of oxygen plasma modified poly (methyl methacrylate)
    • Chai J, Lu F, Li B, Kwok DY, (2004) Wettability interpretation of oxygen plasma modified poly (methyl methacrylate). Langmuir 20 (25): 10919-10927.
    • (2004) Langmuir , vol.20 , Issue.25 , pp. 10919-10927
    • Chai, J.1    Lu, F.2    Li, B.3    Kwok, D.Y.4
  • 27
    • 1442263150 scopus 로고    scopus 로고
    • Adhesion and proliferation of cells on new polymers modified biomaterials
    • Lakard S, Herlem G, Propper A, Kastner A, Michel G, et al. (2004) Adhesion and proliferation of cells on new polymers modified biomaterials. Bioelectrochemistry 62 (1): 19-27.
    • (2004) Bioelectrochemistry , vol.62 , Issue.1 , pp. 19-27
    • Lakard, S.1    Herlem, G.2    Propper, A.3    Kastner, A.4    Michel, G.5
  • 28
    • 20444364161 scopus 로고    scopus 로고
    • Chip surface charge switch for studying histone-DNA interaction by surface plasmon resonance biosensors Analytical Biochemistry
    • Cui X, Yang F, Li A, Yang X, (2005) Chip surface charge switch for studying histone-DNA interaction by surface plasmon resonance biosensors Analytical Biochemistry 342. (1): 173-175.
    • (2005) , vol.342 , Issue.1 , pp. 173-175
    • Cui, X.1    Yang, F.2    Li, A.3    Yang, X.4
  • 29
    • 34948872161 scopus 로고    scopus 로고
    • Enzyme-linked immunosorbent assay of Escherichia coli O157:H7 in surface enhanced poly (methyl methacrylate) microchannels
    • Bai Y, Huang WC, Yang ST, (2007) Enzyme-linked immunosorbent assay of Escherichia coli O157:H7 in surface enhanced poly (methyl methacrylate) microchannels. Biotechnology and Bioengineering 98: 328-339.
    • (2007) Biotechnology and Bioengineering , vol.98 , pp. 328-339
    • Bai, Y.1    Huang, W.C.2    Yang, S.T.3
  • 30
    • 33750065746 scopus 로고    scopus 로고
    • One-step immobilization of cationic polymer onto a poly(methyl methacrylate) microchip for high-performance electrophoretic analysis of proteins
    • Kitagawa F, Kubota K, Sueyoshi K, Otsuka K, (2006) One-step immobilization of cationic polymer onto a poly(methyl methacrylate) microchip for high-performance electrophoretic analysis of proteins. Science and Technology of Advanced Materials 7 (6): 558-565.
    • (2006) Science and Technology of Advanced Materials , vol.7 , Issue.6 , pp. 558-565
    • Kitagawa, F.1    Kubota, K.2    Sueyoshi, K.3    Otsuka, K.4
  • 32
    • 0043172512 scopus 로고    scopus 로고
    • Inkjet printing of polymer micro-arrays and libraries: Instrumentation, requirements, and perspectives
    • De Gans BJ, Schubert US, (2003) Inkjet printing of polymer micro-arrays and libraries: Instrumentation, requirements, and perspectives. Macromolecular Rapid Communications 24: 659-666.
    • (2003) Macromolecular Rapid Communications , vol.24 , pp. 659-666
    • De Gans, B.J.1    Schubert, U.S.2
  • 33
    • 64249152446 scopus 로고    scopus 로고
    • Polymer inkjet printing: Construction of three-dimensional structures at micro-scale by repeated lamination
    • Yun YH, Kim JD, Lee BK, Cho YW, Lee HY, (2009) Polymer inkjet printing: Construction of three-dimensional structures at micro-scale by repeated lamination. Macromolecular Research 17: 197-202.
    • (2009) Macromolecular Research , vol.17 , pp. 197-202
    • Yun, Y.H.1    Kim, J.D.2    Lee, B.K.3    Cho, Y.W.4    Lee, H.Y.5
  • 34
    • 21844438003 scopus 로고    scopus 로고
    • Porous scaffold design for tissue engineering
    • Hollister SJ, (2005) Porous scaffold design for tissue engineering. Nat Mater 4: 518-524.
    • (2005) Nat Mater , vol.4 , pp. 518-524
    • Hollister, S.J.1
  • 35
    • 60349114715 scopus 로고    scopus 로고
    • Protein A-based antibody immobilization onto polymeric microdevices for enhanced sensitivity of enzyme-linked immunosorbent assay
    • Yuan Y, He H, Lee LJ, (2009) Protein A-based antibody immobilization onto polymeric microdevices for enhanced sensitivity of enzyme-linked immunosorbent assay. Biotechnology and Bioengineering 102: 891-901.
    • (2009) Biotechnology and Bioengineering , vol.102 , pp. 891-901
    • Yuan, Y.1    He, H.2    Lee, L.J.3
  • 36
    • 44949150115 scopus 로고    scopus 로고
    • Diagnostic devices as biomaterials: A review of nucleic acid and protein microarray surface performance issues
    • Wu P, Castner DG, Grainger DW, (2008) Diagnostic devices as biomaterials: A review of nucleic acid and protein microarray surface performance issues. Journal of Biomaterials Science, Polymer Edition 19: 725-753.
    • (2008) Journal of Biomaterials Science, Polymer Edition , vol.19 , pp. 725-753
    • Wu, P.1    Castner, D.G.2    Grainger, D.W.3
  • 37
    • 0034622925 scopus 로고    scopus 로고
    • Printing proteins as microarrays for high-throughput function determination
    • MacBeath G, Schreiber SL, (2000) Printing proteins as microarrays for high-throughput function determination. Science 289: 1760-1763.
    • (2000) Science , vol.289 , pp. 1760-1763
    • MacBeath, G.1    Schreiber, S.L.2
  • 38
    • 0013172998 scopus 로고    scopus 로고
    • Controlling Antibody Orientation on Charged Self-Assembled Monolayers
    • S
    • Chen S, Liu L, Zhou, J Jiang, (2003) S (2003) Controlling Antibody Orientation on Charged Self-Assembled Monolayers. Langmuir19: 2859-2864.
    • (2003) Langmuir , vol.19 , pp. 2859-2864
    • Chen, S.1    Liu, L.2    Zhou3    Jiang, J.4
  • 39
    • 84655167908 scopus 로고    scopus 로고
    • Fabrication of protein micropatterns using a functional substrate with convertible protein-adsorption surface properties
    • Yamazoe H (2012) Fabrication of protein micropatterns using a functional substrate with convertible protein-adsorption surface properties. Journal of Biomedical Materials Research- Part A 100 A: 362-369.
    • (2012) Journal of Biomedical Materials Research - Part A , vol.100 A , pp. 362-369
    • Yamazoe, H.1
  • 41
    • 77952106895 scopus 로고    scopus 로고
    • High sensitive detection of C-reactive protein by total internal reflection fluorescence microscopy on rapidly making nano array protein chip
    • Islam MS, Lee HG, Choo J, Song JM, Kang SH, (2010) High sensitive detection of C-reactive protein by total internal reflection fluorescence microscopy on rapidly making nano array protein chip. Talanta 81: 1402-1408.
    • (2010) Talanta , vol.81 , pp. 1402-1408
    • Islam, M.S.1    Lee, H.G.2    Choo, J.3    Song, J.M.4    Kang, S.H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.