메뉴 건너뛰기




Volumn 56, Issue 18, 2011, Pages 5823-5843

Development and validation of a hybrid simulation technique for cone beam CT: Application to an oral imaging system

Author keywords

[No Author keywords available]

Indexed keywords

AIR KERMA; BOW TIE; CONE-BEAM COMPUTED TOMOGRAPHY; CONE-BEAM CT; CONTRAST RESOLUTION; DETECTOR SIMULATIONS; DISCRETE ENERGIES; ENERGY MODULATION; FLAT PANEL DETECTORS; HYBRID SIMULATION; HYBRID TECHNIQUES; INTENSITY PROFILES; ISOCENTERS; LARGE FIELD OF VIEWS; MONTE CARLO DOSE CALCULATION; MONTE CARLO SIMULATION; MONTE CARLO TECHNIQUES; NOISE CHARACTERISTIC; NOISE POWER SPECTRUM; NOISY IMAGE; PHASE SPACES; POTENTIAL RANGE; PROJECTION IMAGE; QUALITY ASSURANCE PROTOCOLS; RADIATION DOSE; RADIATION FIELD; RICHARDSON-LUCY FITTING; SIMULATED IMAGES; WATER PHANTOM; X-RAY GENERATION;

EID: 80052657095     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/56/18/004     Document Type: Article
Times cited : (18)

References (36)
  • 1
    • 34447344115 scopus 로고    scopus 로고
    • Efficiency improvements of x-ray simulations in EGSnrc user-codes using bremsstrahlung cross-section enhancement (BCSE)
    • DOI 10.1118/1.2736778
    • Ali E S M and Rogers D W O 2007 Efficiency improvements of x-ray simulations in EGSnrc user-codes using bremsstrahlung cross-section enhancement (BCSE) Med. Phys. 34 2143-54 (Pubitemid 47055749)
    • (2007) Medical Physics , vol.34 , Issue.6 , pp. 2143-2154
    • Ali, E.S.M.1    Rogers, D.W.O.2
  • 2
    • 41049115062 scopus 로고    scopus 로고
    • Benchmarking EGSnrc in the kilovoltage energy range against experimental measurements of charged particle backscatter coefficients
    • DOI 10.1088/0031-9155/53/6/002, PII S0031915508622198
    • Ali E S M and Rogers D W O 2008 Benchmarking EGSnrc in the kilovoltage energy range against experimental measurements of charged particle backscatter coefficients Phys. Med. Biol. 53 1527-43 (Pubitemid 351422995)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.6 , pp. 1527-1543
    • Ali, E.S.M.1    Rogers, D.W.O.2
  • 3
    • 26244447829 scopus 로고    scopus 로고
    • Development and validation of MCNP4C-based Monte Carlo simulator for fan- and cone-beam x-ray CT
    • DOI 10.1088/0031-9155/50/20/009
    • Ay M R and Zaidi H 2005 Development and validation of MCNP4C-based Monte Carlo simulator for fan- and cone-beam x-ray CT Phys. Med. Biol. 50 4863-85 (Pubitemid 41417009)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.20 , pp. 4863-4885
    • Ay, M.R.1    Zaidi, H.2
  • 4
    • 33644685403 scopus 로고    scopus 로고
    • MANTIS: Combined x-ray, electron and optical Monte Carlo simulations of indirect radiation imaging systems
    • DOI 10.1088/0031-9155/51/6/013, PII S0031915506084508
    • Badano A and Sempau J 2006 MANTIS: combined x-ray, electron and optical Monte Carlo simulations of indirect radiation imaging systems Phys. Med. Biol. 51 1545-61 (Pubitemid 43332354)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.6 , pp. 1545-1561
    • Badano, A.1    Sempau, J.2
  • 6
    • 79551716017 scopus 로고    scopus 로고
    • The effects of compensator and imaging geometry on the distribution of x-ray scatter in CBCT
    • Bootsma G J et al 2011 The effects of compensator and imaging geometry on the distribution of x-ray scatter in CBCT Med. Phys. 38 897-914
    • (2011) Med. Phys. , vol.38 , Issue.2 , pp. 897-914
    • Bootsma, G.J.1
  • 7
    • 2542455683 scopus 로고    scopus 로고
    • Accelerated simulation of cone beam x-ray scatter projections
    • Colijn A P and Beekman F J 2004 Accelerated simulation of cone beam x-ray scatter projections IEEE Trans. Med. Imaging 23 584-90
    • (2004) IEEE Trans. Med. Imaging , vol.23 , Issue.5 , pp. 584-590
    • Colijn, A.P.1    Beekman, F.J.2
  • 8
    • 4644330583 scopus 로고    scopus 로고
    • Experimental validation of a rapid Monte Carlo based micro-CT simulator
    • DOI 10.1088/0031-9155/49/18/009, PII S0031915504812090
    • Colijn A P et al 2004 Experimental validation of a rapid Monte Carlo based micro-CT simulator Phys. Med. Biol. 49 4321-33 (Pubitemid 39302690)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.18 , pp. 4321-4333
    • Colijn, A.P.1    Zbijewski, W.2    Sasov, A.3    Beekman, F.J.4
  • 9
    • 67649397320 scopus 로고    scopus 로고
    • Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: A systematic review of the literature
    • De Vos W et al 2009 Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: a systematic review of the literature Int. J. Oral Maxillofac. Surg. 38 609-25
    • (2009) Int. J. Oral Maxillofac. Surg. , vol.38 , Issue.6 , pp. 609-625
    • De Vos, W.1
  • 10
    • 34247476291 scopus 로고    scopus 로고
    • Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapy
    • DOI 10.1088/0031-9155/52/6/004, PII S0031915507361216, 004
    • Ding G X et al 2007 Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapy Phys. Med. Biol. 52 1595-615 (Pubitemid 46646369)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.6 , pp. 1595-1615
    • Ding, G.X.1    Duggan, D.M.2    Coffey, C.W.3
  • 11
    • 40049093127 scopus 로고    scopus 로고
    • Accurate patient dosimetry of kilovoltage cone-beam CT in radiation therapy
    • DOI 10.1118/1.2839096
    • Ding G X et al 2008 Accurate patient dosimetry of kilovoltage cone-beam CT in radiation therapy Med. Phys. 35 1135-44 (Pubitemid 351322659)
    • (2008) Medical Physics , vol.35 , Issue.3 , pp. 1135-1144
    • Ding, G.X.1    Duggan, D.M.2    Coffey, C.W.3
  • 12
    • 33646455469 scopus 로고    scopus 로고
    • Intercomparison of methods for image quality characterization: II. Noise power spectrum
    • Dobbins J T III et al 2006 Intercomparison of methods for image quality characterization: II. Noise power spectrum Med. Phys. 33 1466-75
    • (2006) Med. Phys. , vol.33 , Issue.5 , pp. 1466-1475
    • Dobbins, J.T.1
  • 13
    • 69549111127 scopus 로고    scopus 로고
    • Monte Carlo simulation and patient dosimetry for a kilovoltage cone-beam CT unit
    • Downes P et al 2009 Monte Carlo simulation and patient dosimetry for a kilovoltage cone-beam CT unit Med. Phys. 36 4156-67
    • (2009) Med. Phys. , vol.36 , Issue.9 , pp. 4156-4167
    • Downes, P.1
  • 15
    • 66249121398 scopus 로고    scopus 로고
    • Basic principles for use of dental cone beam computed tomography: Consensus guidelines of the European Academy of Dental and Maxillofacial Radiology
    • Horner K et al 2009 Basic principles for use of dental cone beam computed tomography: consensus guidelines of the European Academy of Dental and Maxillofacial Radiology Dentomaxillofac. Radiol. 38 187-95
    • (2009) Dentomaxillofac. Radiol. , vol.38 , Issue.4 , pp. 187-195
    • Horner, K.1
  • 19
    • 40949104442 scopus 로고    scopus 로고
    • The 2007 recommendations of the International Commission on Radiological Protection
    • ICRP 2007 The 2007 recommendations of the International Commission on Radiological Protection ICRP Publication 103 (Amsterdam: Elsevier)
    • (2007) ICRP Publication 103
  • 21
    • 80052688508 scopus 로고    scopus 로고
    • Medical electrical equipment - Characteristics of digital x-ray imaging devices: Part 1. Determination of the detective quantum efficiency
    • IEC 2003 Medical electrical equipment - characteristics of digital x-ray imaging devices: part 1. Determination of the detective quantum efficiency International Standard IEC 62220-1 (Geneva: International Electrotechnical Commission)
    • (2003) International Standard IEC 62220-1
  • 23
    • 7244223252 scopus 로고    scopus 로고
    • Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting
    • DOI 10.1118/1.1788912
    • Kawrakow I et al 2004 Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting Med. Phys. 31 2883-98 (Pubitemid 39431018)
    • (2004) Medical Physics , vol.31 , Issue.10 , pp. 2883-2898
    • Kawrakow, I.1    Rogers, D.W.O.2    Walters, B.R.B.3
  • 24
    • 0003797114 scopus 로고    scopus 로고
    • The EGSnrc code system: Monte Carlo simulation of electron and photon transport
    • Kawrakow I et al 2010 The EGSnrc code system: Monte Carlo simulation of electron and photon transport NRCC Report PIRS-701 (Ottawa: National Research Council)
    • (2010) NRCC Report PIRS-701
    • Kawrakow, I.1
  • 25
    • 69949169325 scopus 로고    scopus 로고
    • Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applications
    • Loubele M et al 2009 Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applications Eur. J. Radiol. 71 461-8
    • (2009) Eur. J. Radiol. , vol.71 , Issue.3 , pp. 461-468
    • Loubele, M.1
  • 26
    • 67449150195 scopus 로고    scopus 로고
    • Conebeam CT of the head and neck: Part 1. Physical principles
    • Miracle A C and Mukherji S K 2009a Conebeam CT of the head and neck: part 1. Physical principles Am. J. Neuroradiol. 30 1088-95
    • (2009) Am. J. Neuroradiol. , vol.30 , Issue.6 , pp. 1088-1095
    • Miracle, A.C.1    Mukherji, S.K.2
  • 27
    • 68549104047 scopus 로고    scopus 로고
    • Conebeam CT of the head and neck: Part 2. Clinical applications
    • Miracle A C and Mukherji S K 2009b Conebeam CT of the head and neck: part 2. Clinical applications Am. J. Neuroradiol. 30 1285-92
    • (2009) Am. J. Neuroradiol. , vol.30 , Issue.7 , pp. 1285-1292
    • Miracle, A.C.1    Mukherji, S.K.2
  • 29
    • 33646438839 scopus 로고    scopus 로고
    • Intercomparison of methods for image quality characterization: I. Modulation transfer function
    • Samei E et al 2006 Intercomparison of methods for image quality characterization: I. Modulation transfer function Med. Phys. 33 1454-65
    • (2006) Med. Phys. , vol.33 , Issue.5 , pp. 1454-1465
    • Samei, E.1
  • 30
    • 0041461316 scopus 로고    scopus 로고
    • A method for modifying the image quality parameters of digital radiographic images
    • DOI 10.1118/1.1621870
    • Saunders R S Jr and Samei E 2003 A method for modifying the image quality parameters of digital radiographic images Med. Phys. 30 3006-17 (Pubitemid 37444311)
    • (2003) Medical Physics , vol.30 , Issue.11 , pp. 3006-3017
    • Saunders Jr., R.S.1    Samei, E.2
  • 31
    • 0021952059 scopus 로고
    • Fast calculation of the exact radiological path for a three-dimensional CT array
    • DOI 10.1118/1.595715
    • Siddon R L 1985 Fast calculation of the exact radiological path for a three-dimensional CT array Med. Phys. 12 252-5 (Pubitemid 15089015)
    • (1985) Medical Physics , vol.12 , Issue.2 , pp. 252-255
    • Siddon, R.L.1
  • 32
    • 77952394618 scopus 로고    scopus 로고
    • Validation of an image simulation technique for two computed radiography systems: An application to neonatal imaging
    • Smans K et al 2010 Validation of an image simulation technique for two computed radiography systems: an application to neonatal imaging Med. Phys. 37 2092-100
    • (2010) Med. Phys. , vol.37 , Issue.5 , pp. 2092-2100
    • Smans, K.1
  • 33
    • 58149125640 scopus 로고    scopus 로고
    • Monte Carlo simulation of an x-ray volume imaging cone beam CT unit
    • Spezi E et al 2009 Monte Carlo simulation of an x-ray volume imaging cone beam CT unit Med. Phys. 36 127-36
    • (2009) Med. Phys. , vol.36 , Issue.1 , pp. 127-136
    • Spezi, E.1
  • 34
    • 69249102664 scopus 로고    scopus 로고
    • Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners
    • Suomalainen A et al 2009 Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners Dentomaxillofac. Radiol. 38 367-78
    • (2009) Dentomaxillofac. Radiol. , vol.38 , Issue.6 , pp. 367-378
    • Suomalainen, A.1
  • 35
    • 0036908431 scopus 로고    scopus 로고
    • History by history statistical estimators in the BEAM code system
    • DOI 10.1118/1.1517611
    • Walters B R B et al 2002 History by history statistical estimators in the BEAM code system Med. Phys. 29 2745-52 (Pubitemid 36008467)
    • (2002) Medical Physics , vol.29 , Issue.12 , pp. 2745-2752
    • Walters, B.R.B.1    Kawrakow, I.2    Rogers, D.W.O.3
  • 36
    • 67649574372 scopus 로고    scopus 로고
    • Skeletal dosimetry in cone beam computed tomography
    • Walters B R B et al 2009 Skeletal dosimetry in cone beam computed tomography Med. Phys. 36 2915-22
    • (2009) Med. Phys. , vol.36 , Issue.7 , pp. 2915-2922
    • Walters, B.R.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.