메뉴 건너뛰기




Volumn 97, Issue 12, 2009, Pages 1938-1953

Review of computational anthropomorphic anatomical and physiological models

Author keywords

Anthropomorphic models; Human anatomy; Hybrid models; Laboratory animal anatomy; Monte Carlo simulation; Radiological imaging; Stylized models; Voxel models

Indexed keywords

ANIMALS; BIOINFORMATICS; DOSIMETRY; INTELLIGENT SYSTEMS; LABORATORIES; MAGNETIC RESONANCE IMAGING; MEDICAL IMAGING; MONTE CARLO METHODS; PARTICLE BEAMS; PHYSIOLOGY; POSITRON EMISSION TOMOGRAPHY; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY;

EID: 70450270835     PISSN: 00189219     EISSN: None     Source Type: Journal    
DOI: 10.1109/JPROC.2009.2032852     Document Type: Review
Times cited : (56)

References (147)
  • 1
    • 34047226505 scopus 로고    scopus 로고
    • Computational anthropomorphic models of the human anatomy: The path to realistic Monte Carlo modeling in medical imaging
    • H. Zaidi and X. G. Xu, "Computational anthropomorphic models of the human anatomy: The path to realistic Monte Carlo modeling in medical imaging" Annu. Rev. Biomed. Eng., vol. 9, pp. 471-500, 2007.
    • (2007) Annu. Rev. Biomed. Eng. , vol.9 , pp. 471-500
    • Zaidi, H.1    Xu, X.G.2
  • 2
    • 0032916211 scopus 로고    scopus 로고
    • Relevance of accurate Monte Carlo modeling in nuclear medical imaging
    • H. Zaidi, "Relevance of accurate Monte Carlo modeling in nuclear medical imaging" Med. Phys., vol. 26, pp. 574-608, 1999.
    • (1999) Med. Phys. , vol.26 , pp. 574-608
    • Zaidi, H.1
  • 3
    • 0003769928 scopus 로고    scopus 로고
    • Monte Carlo calculations in nuclear medicine: Applications in diagnostic imaging
    • Bristol, U.K.: Institute of Physics
    • M. Ljungberg, S.-E. Strand, and M. A. King, "Monte Carlo calculations in nuclear medicine: Applications in diagnostic imaging" in Medical Physics Series. Bristol, U.K.: Institute of Physics, 1998.
    • (1998) Medical Physics Series
    • Ljungberg, M.1    Strand, S.-E.2    King, M.A.3
  • 4
    • 70450266827 scopus 로고    scopus 로고
    • Therapeutic applications of Monte Carlo calculations in nuclear medicine
    • H. Zaidi and G. Sgouros, Eds. Bristol, U.K.: Institute of Physics
    • H. Zaidi and G. Sgouros, "Therapeutic applications of Monte Carlo calculations in nuclear medicine" in Series in Medical Physics and Biomedical Engineering, H. Zaidi and G. Sgouros, Eds. Bristol, U.K.: Institute of Physics, 2002.
    • (2002) Series in Medical Physics and Biomedical Engineering
    • Zaidi, H.1    Sgouros, G.2
  • 5
    • 1342330131 scopus 로고    scopus 로고
    • Voxel-based computational models of real human anatomy: A review
    • M. Caon, "Voxel-based computational models of real human anatomy: A review" Radiat. Environ. Biophys., vol. 42, pp. 229-235, 2004.
    • (2004) Radiat. Environ. Biophys. , vol.42 , pp. 229-235
    • Caon, M.1
  • 7
    • 0001774096 scopus 로고    scopus 로고
    • Mathematical models of the human anatomy
    • Medicine H. Zaidi and G. Sgouros Eds. Bristol U.K.: Institute of Physics
    • J. W. Poston, W. Bolch, and L. Bouchet, "Mathematical models of the human anatomy" in Therapeutic Applications of Monte Carlo Calculations in Nuclear Medicine, H. Zaidi and G. Sgouros, Eds. Bristol, U.K.: Institute of Physics, 2002, pp. 108-132.
    • (2002) Therapeutic Applications of Monte Carlo Calculations in Nuclear , pp. 108-132
    • Poston, J.W.1    Bolch, W.2    Bouchet, L.3
  • 8
    • 0003855286 scopus 로고
    • Phantoms and computational models in therapy, diagnosis and protection
    • ICRU Bethesda, MD
    • ICRU, "Phantoms and computational models in therapy, diagnosis and protection" Bethesda, MD, ICRU Rep. 48, 1992.
    • (1992) ICRU Rep , vol.48
  • 9
    • 14644394232 scopus 로고    scopus 로고
    • A dynamic renal phantom for nuclear medicine studies
    • A. S. SabbirAhmed, M. Demir, L. Kabasakal, and I. Uslu, "A dynamic renal phantom for nuclear medicine studies" Med. Phys., vol. 32, pp. 530-538, 2005.
    • (2005) Med. Phys. , vol.32 , pp. 530-538
    • Sabbir Ahmed, A.S.1    Demir, M.2    Kabasakal, L.3    Uslu, I.4
  • 10
    • 15044352546 scopus 로고    scopus 로고
    • Accuracy of 4 different algorithms for the analysis of tomographic radionuclide ventriculography using a physical, dynamic 4-chamber cardiac phantom
    • P. De Bondt, T. Claessens, B. Rys, O. De Winter, S. Vandenberghe, P. Segers, P. Verdonck, and R. A. Dierckx, "Accuracy of 4 different algorithms for the analysis of tomographic radionuclide ventriculography using a physical, dynamic 4-chamber cardiac phantom" J. Nucl. Med., vol. 46, pp. 165-171, 2005.
    • (2005) J. Nucl. Med. , vol.46 , pp. 165-171
    • De Bondt, P.1    Claessens, T.2    Rys, B.3    De Winter, O.4    Vandenberghe, S.5    Segers, P.6    Verdonck, P.7    Dierckx, R.A.8
  • 11
    • 22844435983 scopus 로고    scopus 로고
    • Evaluation of spatial and temporal resolution for ECG-gated 16-row multidetector CT using a dynamic cardiac phantom
    • P. G. Begemann, U. van Stevendaal, R. Manzke, A. Stork, F. Weiss, C. Nolte-Ernsting, M. Grass, and G. Adam, "Evaluation of spatial and temporal resolution for ECG-gated 16-row multidetector CT using a dynamic cardiac phantom" Eur. Radiol., vol. 15, pp. 1015-1026, 2005.
    • (2005) Eur. Radiol. , vol.15 , pp. 1015-1026
    • Begemann, P.G.1    Van Stevendaal, U.2    Manzke, R.3    Stork, A.4    Weiss, F.5    Nolte-Ernsting, C.6    Grass, M.7    Adam, G.8
  • 13
    • 84903808359 scopus 로고    scopus 로고
    • A new fully-digital anthropomorphic and dynamic thorax/heart model
    • R. Haddad, I. E. Magnin, and P. Clarysse, "A new fully-digital anthropomorphic and dynamic thorax/heart model" in Proc. Conf. IEEE Eng. Med. Biol. Soc., 2007, vol. 2007, pp. 6000-6003.
    • (2007) Proc. Conf. IEEE Eng. Med. Biol. Soc. , vol.2007 , pp. 6000-6003
    • Haddad, R.1    Magnin, I.E.2    Clarysse, P.3
  • 14
    • 33845920013 scopus 로고    scopus 로고
    • Technical note: A deformable phantom for dynamic modeling in radiation therapy
    • DOI 10.1118/1.2400612
    • R. Kashani, K. Lam, D. Litzenberg, and J. Balter, "Technical note: A deformable phantom for dynamic modeling in radiation therapy" Med. Phys., vol. 34, pp. 199-201, 2007. (Pubitemid 46035242)
    • (2007) Medical Physics , vol.34 , Issue.1 , pp. 199-201
    • Kashani, R.1    Lam, K.2    Litzenberg, D.3    Balter, J.4
  • 16
    • 33646479953 scopus 로고    scopus 로고
    • Development of pregnant female, hybrid voxel-mathematical models and their application to the dosimetry of applied magnetic and electric fields at 50 Hz
    • P. Dimbylow, "Development of pregnant female, hybrid voxel-mathematical models and their application to the dosimetry of applied magnetic and electric fields at 50 Hz" Phys. Med. Biol., vol. 51, pp. 2383-2394, 2006.
    • (2006) Phys. Med. Biol. , vol.51 , pp. 2383-2394
    • Dimbylow, P.1
  • 17
    • 34249735327 scopus 로고    scopus 로고
    • Hybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models
    • C. Lee, D. Lodwick, D. Hasenauer, J. L. Williams, and W. E. Bolch, "Hybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models" Phys. Med. Biol., vol. 52, pp. 3309-3333, 2007.
    • (2007) Phys. Med. Biol. , vol.52 , pp. 3309-3333
    • Lee, C.1    Lodwick, D.2    Hasenauer, D.3    Williams, J.L.4    Bolch, W.E.5
  • 18
    • 44349130967 scopus 로고    scopus 로고
    • Hybrid computational phantoms of the 15-year male and female adolescent: Applications to CT organ dosimetry for patients of variable morphometry
    • C. Lee, D. Lodwick, J. L. Williams, and W. E. Bolch, "Hybrid computational phantoms of the 15-year male and female adolescent: Applications to CT organ dosimetry for patients of variable morphometry" Med. Phys., vol. 35, pp. 2366-2382, 2008.
    • (2008) Med. Phys. , vol.35 , pp. 2366-2382
    • Lee, C.1    Lodwick, D.2    Williams, J.L.3    Bolch, W.E.4
  • 19
    • 77950147331 scopus 로고    scopus 로고
    • Adult reference computational phantoms ICRP
    • ICRP Joint ICRP/ICRU Rep.
    • ICRP, "Adult reference computational phantoms ICRP" ICRP Pub. 108 (Joint ICRP/ICRU Rep.), 2009.
    • (2009) ICRP Pub , vol.108
  • 22
    • 0003689772 scopus 로고
    • Report of Committee II on permissible dose for internal radiation
    • ICRP
    • ICRP, "Report of Committee II on permissible dose for internal radiation" ICRP Pub. 2, 1959.
    • (1959) ICRP Pub , vol.2
  • 23
    • 0012389524 scopus 로고
    • BMIRD Pamphlet No. 5: Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom
    • W. S. Snyder, M. R. Ford, G. G. Warner, and H. L. Fisher, "MIRD Pamphlet No. 5: Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom" J. Nucl. Med., vol. 10, pp. 5-52, 1969, suppl. 3.
    • (1969) J. Nucl. Med. , vol.10 , pp. 5-52
    • Snyder, W.S.1    Ford, M.R.2    Warner, G.G.3    Fisher, H.L.4
  • 25
    • 0003444170 scopus 로고
    • Report of the Task Group on Reference Man
    • ICRP
    • ICRP, "Report of the Task Group on Reference Man" ICRP Pub. 23, 1975.
    • (1975) ICRP Pub , vol.23
  • 26
    • 75549099381 scopus 로고
    • Gamma-ray dosimetry of internal emitters. I. Monte Carlo calculations of absorbed dose from point sources
    • W. H. Ellet, A. B. Callahan, and G. L. Brownell, "Gamma-ray dosimetry of internal emitters, I. Monte Carlo calculations of absorbed dose from point sources" Br. J. Radiol., vol. 37, pp. 45-52, 1964.
    • (1964) Br. J. Radiol. , vol.37 , pp. 45-52
    • Ellet, W.H.1    Callahan, A.B.2    Brownell, G.L.3
  • 27
    • 0002166050 scopus 로고
    • MIRD pamphlet No. 3: Absorbed fractions for photon dosimetry
    • G. L. Brownell, W. H. Ellet, and A. R. Reddy, "MIRD pamphlet No. 3: Absorbed fractions for photon dosimetry" J. Nucl. Med., vol. 27, pp. 27-39, 1968.
    • (1968) J. Nucl. Med. , vol.27 , pp. 27-39
    • Brownell, G.L.1    Ellet, W.H.2    Reddy, A.R.3
  • 28
    • 70450236515 scopus 로고
    • Variation of dose delivered by 137Cs as a function of body size from infancy to adulthood
    • Oak Ridge National Lab., "Variation of dose delivered by 137Cs as a function of body size from infancy to adulthood" ORNL-4007, 1966.
    • (1966) ORNL-4007
  • 30
    • 70450257110 scopus 로고
    • Specific absorbed fractions of energy at various ages from internal photon sources: I methods, II one year old, III five year old, IV ten year old, v fifteen year old male and adult female, VI new-born and VII adult male, Oak Ridge National Lab
    • M. Cristy and K. F. Eckerman, "Specific absorbed fractions of energy at various ages from internal photon sources: I methods, II one year old, III five year old, IV ten year old, V fifteen year old male and adult female, VI new-born and VII adult male, Oak Ridge National Lab." ORNL/TM 8381/V1-V7, 1987.
    • (1987) ORNL/TM 8381/V1-V7
    • Cristy, M.1    Eckerman, K.F.2
  • 31
    • 33645104242 scopus 로고    scopus 로고
    • Revisions to the ORNL series of adult and pediatric computational phantoms for use with the MIRD schema
    • E. Y. Han, W. E. Bolch, and K. F. Eckerman, "Revisions to the ORNL series of adult and pediatric computational phantoms for use with the MIRD schema" Health Phys., vol. 90, pp. 337-356, 2006.
    • (2006) Health Phys. , vol.90 , pp. 337-356
    • Han, E.Y.1    Bolch, W.E.2    Eckerman, K.F.3
  • 32
    • 0004040187 scopus 로고
    • Mathematical models and specific absorbed fractions of photon energy in the nonpregnant adult female and at the end of each trimester of pregnancy, Oak Ridge National Lab.
    • M. G. Stabin, E. Watson, M. Cristy, J. Ryman, K. Eckerman, J. Davis, D. Marshall, and K. Gehlen, "Mathematical models and specific absorbed fractions of photon energy in the nonpregnant adult female and at the end of each trimester of pregnancy, Oak Ridge National Lab." ORNL/TM-12907, 1995.
    • (1995) ORNL/TM-12907
    • Stabin, M.G.1    Watson, E.2    Cristy, M.3    Ryman, J.4    Eckerman, K.5    Davis, J.6    Marshall, D.7    Gehlen, K.8
  • 33
    • 0003547765 scopus 로고
    • The calculation of dose from external photon exposures using reference human phantoms and Monte-Carlo methods, Part 1: The male (ADAM) and female (EVA) adult mathematical phantoms
    • Dec.
    • R. Kramer, M. Zankl, G. Williams, and D. G., "The calculation of dose from external photon exposures using reference human phantoms and Monte-Carlo methods, Part 1: The male (ADAM) and female (EVA) adult mathematical phantoms" GSF Bericht S-885, Dec. 1982.
    • (1982) GSF Bericht S-885
    • Kramer, R.1    Zankl, M.2    Williams, G.3
  • 34
    • 0004159251 scopus 로고    scopus 로고
    • Conversion coefficients for use in radiological protection against external radiation
    • ICRP
    • ICRP, "Conversion coefficients for use in radiological protection against external radiation" ICRP Pub. 74, 1996.
    • (1996) ICRP Pub , vol.74
  • 35
    • 0040168902 scopus 로고
    • Dosimetric evaluation of brain scanning agents
    • U.S. Dept. of Health and Human Services, Oak Ridge, TN HHS Pub. FDA
    • K. Eckerman, M. Cristy, and G. G. Warner, "Dosimetric evaluation of brain scanning agents" in Proc. 3rd Int. Radiopharm. Dosim. Symp., U.S. Dept. of Health and Human Services, Oak Ridge, TN, 1981, pp. 527-540, HHS Pub. FDA 81-8166.
    • (1981) Proc. 3rd Int. Radiopharm. Dosim. Symp. , pp. 527-540
    • Eckerman, K.1    Cristy, M.2    Warner, G.G.3
  • 36
    • 0033059292 scopus 로고    scopus 로고
    • BMIRD Pamphlet No. 15: Radionuclide S values in a revised dosimetric model of the adult head and brain; Medical internal radiation dose
    • L. G. Bouchet, W. E. Bolch, D. A. Weber, H. L. Atkins, and J. W. Poston, "MIRD Pamphlet No. 15: Radionuclide S values in a revised dosimetric model of the adult head and brain; Medical internal radiation dose" J. Nucl. Med., vol. 40, pp. 62S-101S, 1999.
    • (1999) J. Nucl. Med. , vol.40
    • Bouchet, L.G.1    Bolch, W.E.2    Weber, D.A.3    Atkins, H.L.4    Poston, J.W.5
  • 37
    • 0032868032 scopus 로고    scopus 로고
    • Five pediatric head and brain mathematical models for use in internal dosimetry
    • L. G. Bouchet and W. E. Bolch, "Five pediatric head and brain mathematical models for use in internal dosimetry" J. Nucl. Med., vol. 40, pp. 1327-1336, 1999.
    • (1999) J. Nucl. Med. , vol.40 , pp. 1327-1336
    • Bouchet, L.G.1    Bolch, W.E.2
  • 38
    • 0021085057 scopus 로고
    • Biodistribution and dosimetry of N-isopropyl-p-[123] Iiodoamphetamine in the primate
    • B. L. Holman, R. E. Zimmerman, J. R. Schapiro, M. L. Kaplan, A. G. Jones, and T. C. Hill, "Biodistribution and dosimetry of N-isopropyl-p-[123] Iiodoamphetamine in the primate" J. Nucl. Med., vol. 24, pp. 922-931, 1983.
    • (1983) J. Nucl. Med. , vol.24 , pp. 922-931
    • Holman, B.L.1    Zimmerman, R.E.2    Schapiro, J.R.3    Kaplan, M.L.4    Jones, A.G.5    Hill, T.C.6
  • 39
    • 30844432390 scopus 로고    scopus 로고
    • A new human eye model for ophthalmic brachytherapy dosimetry
    • H. Yoriyaz, A. Sanchez, and A. dos Santos, "A new human eye model for ophthalmic brachytherapy dosimetry" Radiat. Prot. Dosim., vol. 115, pp. 316-319, 2005.
    • (2005) Radiat. Prot. Dosim. , vol.115 , pp. 316-319
    • Yoriyaz, H.1    Sanchez, A.2    Dos Santos, A.3
  • 40
    • 70249129104 scopus 로고    scopus 로고
    • Dose conversion coefficients for electron exposure of the human eye lens
    • R. Behrens, G. Dietze, and M. Zankl, "Dose conversion coefficients for electron exposure of the human eye lens" Phys. Med. Biol., vol. 54, pp. 4069-4087, 2009.
    • (2009) Phys. Med. Biol. , vol.54 , pp. 4069-4087
    • Behrens, R.1    Dietze, G.2    Zankl, M.3
  • 41
    • 0030749314 scopus 로고    scopus 로고
    • Internal dose estimation including the nasal cavity and major airway for continuous inhalation of C15O2, 15O2 and C15O using the thermoluminescent dosimeter method
    • H. Deloar, H. Watabe, T. Nakamura, Y. Narita, A. Yamadera, T. Fujiwara, and M. Itoh, "Internal dose estimation including the nasal cavity and major airway for continuous inhalation of C15O2, 15O2 and C15O using the thermoluminescent dosimeter method" J. Nucl. Med., vol. 38, pp. 1603-1613, 1997.
    • (1997) J. Nucl. Med. , vol.38 , pp. 1603-1613
    • Deloar, H.1    Watabe, H.2    Nakamura, T.3    Narita, Y.4    Yamadera, A.5    Fujiwara, T.6    Itoh, M.7
  • 42
    • 0024854442 scopus 로고
    • A model of the peritoneal cavity for use in internal dosimetry
    • E. E. Watson, M. G. Stabin, J. L. Davis, and K. F. Eckerman, "A model of the peritoneal cavity for use in internal dosimetry" J. Nucl. Med., vol. 30, pp. 2002-2011, 1989.
    • (1989) J. Nucl. Med. , vol.30 , pp. 2002-2011
    • Watson, E.E.1    Stabin, M.G.2    Davis, J.L.3    Eckerman, K.F.4
  • 43
    • 0028288133 scopus 로고
    • A model of the prostate gland for use in internal dosimetry
    • M. G. Stabin, "A model of the prostate gland for use in internal dosimetry" J. Nucl. Med., vol. 35, pp. 516-520, 1994.
    • (1994) J. Nucl. Med. , vol.35 , pp. 516-520
    • Stabin, M.G.1
  • 44
    • 0033972187 scopus 로고    scopus 로고
    • Electron absorbed fractions and dose conversion factors for marrow and bone by skeletal regions
    • K. F. Eckerman and M. G. Stabin, "Electron absorbed fractions and dose conversion factors for marrow and bone by skeletal regions" Health Phys., vol. 78, pp. 199-214, 2000.
    • (2000) Health Phys. , vol.78 , pp. 199-214
    • Eckerman, K.F.1    Stabin, M.G.2
  • 45
    • 0033968733 scopus 로고    scopus 로고
    • S values for radionuclides localized within the skeleton
    • L. G. Bouchet, W. E. Bolch, R. W. Howell, and D. V. Rao, "S values for radionuclides localized within the skeleton" J. Nucl. Med., vol. 41, pp. 189-212, 2000.
    • (2000) J. Nucl. Med. , vol.41 , pp. 189-212
    • Bouchet, L.G.1    Bolch, W.E.2    Howell, R.W.3    Rao, D.V.4
  • 46
    • 0029791714 scopus 로고    scopus 로고
    • A revised model for the calculation of absorbed energy in the gastrointestinal tract
    • J. W. Poston, K. A. Kodimer, and W. E. Bolch, "A revised model for the calculation of absorbed energy in the gastrointestinal tract" Health Phys., vol. 71, pp. 307-314, 1996.
    • (1996) Health Phys. , vol.71 , pp. 307-314
    • Poston, J.W.1    Kodimer, K.A.2    Bolch, W.E.3
  • 48
    • 0042279207 scopus 로고    scopus 로고
    • MIRD Pamphlet No 19: Absorbed fractions and radionuclide S values for six age-dependent multiregion models of the kidney
    • L. G. Bouchet, W. E. Bolch, H. P. Blanco, B.W. Wessels, J. A. Siegel, D. A. Rajon, I. Clairand, and G. Sgouros, "MIRD Pamphlet No 19: Absorbed fractions and radionuclide S values for six age-dependent multiregion models of the kidney" J. Nucl. Med., vol. 44, pp. 1113-1147, 2003.
    • (2003) J. Nucl. Med. , vol.44 , pp. 1113-1147
    • Bouchet, L.G.1    Bolch, W.E.2    Blanco, H.P.3    Wessels, B.W.4    Siegel, J.A.5    Rajon, D.A.6    Clairand, I.7    Sgouros, G.8
  • 49
    • 0027958549 scopus 로고
    • Absorbed fractions for electrons and beta particles in spheres of various sizes
    • J. A. Siegel and M. G. Stabin, "Absorbed fractions for electrons and beta particles in spheres of various sizes" J. Nucl. Med., vol. 35, pp. 152-156, 1994.
    • (1994) J. Nucl. Med. , vol.35 , pp. 152-156
    • Siegel, J.A.1    Stabin, M.G.2
  • 50
    • 0033972633 scopus 로고    scopus 로고
    • Re-evaluation of absorbed fractions for photons and electrons in spheres of various sizes
    • M. G. Stabin and M. W. Konijnenberg, "Re-evaluation of absorbed fractions for photons and electrons in spheres of various sizes" J. Nucl. Med., vol. 41, pp. 149-160, 2000.
    • (2000) J. Nucl. Med. , vol.41 , pp. 149-160
    • Stabin, M.G.1    Konijnenberg, M.W.2
  • 51
    • 0033776755 scopus 로고    scopus 로고
    • Improvement of internal dose calculations using mathematical models of different adult heights
    • I. Clairand, L. G. Bouchet, M. Ricard, M. Durigon, M. Di-Paola, and B. Aubert, "Improvement of internal dose calculations using mathematical models of different adult heights" Phys. Med. Biol., vol. 45, pp. 2771-2785, 2000.
    • (2000) Phys. Med. Biol. , vol.45 , pp. 2771-2785
    • Clairand, I.1    Bouchet, L.G.2    Ricard, M.3    Durigon, M.4    Di-Paola, M.5    Aubert, B.6
  • 52
    • 0142198902 scopus 로고    scopus 로고
    • A review of US anthropometric reference data (1971-2000) with comparisons to both stylized and tomographic anatomic models
    • C. Huh and W. E. Bolch, "A review of US anthropometric reference data (1971-2000) with comparisons to both stylized and tomographic anatomic models" Phys. Med. Biol., vol. 48, pp. 3411-3429, 2003.
    • (2003) Phys. Med. Biol. , vol.48 , pp. 3411-3429
    • Huh, C.1    Bolch, W.E.2
  • 53
    • 38049115668 scopus 로고    scopus 로고
    • Anthropometric approaches and their uncertainties to assigning computational phantoms to individual patients in pediatric dosimetry studies
    • S. Whalen, C. Lee, J. L. Williams, and W. E. Bolch, "Anthropometric approaches and their uncertainties to assigning computational phantoms to individual patients in pediatric dosimetry studies" Phys. Med. Biol., vol. 53, pp. 453-471, 2008.
    • (2008) Phys. Med. Biol. , vol.53 , pp. 453-471
    • Whalen, S.1    Lee, C.2    Williams, J.L.3    Bolch, W.E.4
  • 54
    • 0016068330 scopus 로고
    • The Fourier reconstruction of a head phantom
    • L. A. Shepp and B. F. Logan, "The Fourier reconstruction of a head phantom" IEEE Trans. Nucl. Sci., vol. NS-21, pp. 21-43, 1974.
    • (1974) IEEE Trans. Nucl. Sci. , vol.NS-21 , pp. 21-43
    • Shepp, L.A.1    Logan, B.F.2
  • 55
    • 34548681121 scopus 로고    scopus 로고
    • Institute of Medical Physics, Erlangen, Germany Online
    • Institute of Medical Physics, Erlangen, Germany, The FORBILD Phantom Database. [Online]. Available: http://www.imp. uni-erlangen.de/phantoms
    • The FORBILD Phantom Database
  • 57
    • 0035246235 scopus 로고    scopus 로고
    • Modeling respiratory mechanics in the MCAT and spline-based MCAT phantoms
    • W. P. Segars, D. S. Lalush, and B. M. W. Tsui, "Modeling respiratory mechanics in the MCAT and spline-based MCAT phantoms" IEEE Trans. Nucl. Sci., vol. 48, pp. 89-97, 2001.
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , pp. 89-97
    • Segars, W.P.1    Lalush, D.S.2    Tsui, B.M.W.3
  • 58
    • 1642446494 scopus 로고    scopus 로고
    • Four-dimensional Monte Carlo simulation of time-dependent geometries
    • H. Paganetti, "Four-dimensional Monte Carlo simulation of time-dependent geometries" Phys. Med. Biol., vol. 49, pp. N75-N81, 2004.
    • (2004) Phys. Med. Biol. , vol.49
    • Paganetti, H.1
  • 59
    • 4744351435 scopus 로고    scopus 로고
    • Monte Carlo simulations with time-dependent geometries to investigate effects of organ motion with high temporal resolution
    • H. Paganetti, H. Jiang, J. A. Adams, G. T. Chen, and E. Rietzel, "Monte Carlo simulations with time-dependent geometries to investigate effects of organ motion with high temporal resolution" Int. J. Radiat. Oncol. Biol. Phys., vol. 60, pp. 942-950, 2004.
    • (2004) Int. J. Radiat. Oncol. Biol. Phys. , vol.60 , pp. 942-950
    • Paganetti, H.1    Jiang, H.2    Adams, J.A.3    Chen, G.T.4    Rietzel, E.5
  • 60
    • 40349091859 scopus 로고    scopus 로고
    • Development of a geometry-based respiratory motion-simulating patient model for radiation treatment dosimetry
    • J. Zhang, X. G. Xu, C. Shi, and M. Fuss, "Development of a geometry-based respiratory motion-simulating patient model for radiation treatment dosimetry" J. Appl. Clin. Med. Phys., vol. 9, pp. 16-28, 2008.
    • (2008) J. Appl. Clin. Med. Phys. , vol.9 , pp. 16-28
    • Zhang, J.1    Xu, X.G.2    Shi, C.3    Fuss, M.4
  • 61
    • 0033314072 scopus 로고    scopus 로고
    • Four-dimensional superquadric-based cardiac phantom for Monte Carlo simulation of radiological imaging systems
    • J. Peter, D. R. Gilland, R. J. Jaszczak, and R. E. Coleman, "Four-dimensional superquadric-based cardiac phantom for Monte Carlo simulation of radiological imaging systems" IEEE Trans. Nucl. Sci., vol. 46, pp. 2211-2217, 1999.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , pp. 2211-2217
    • Peter, J.1    Gilland, D.R.2    Jaszczak, R.J.3    Coleman, R.E.4
  • 63
    • 27244447259 scopus 로고    scopus 로고
    • Computed tomography simulation with superquadrics
    • J. Zhu, S. Zhao, Y. Ye, and G. Wang, "Computed tomography simulation with superquadrics" Med. Phys., vol. 32, pp. 3136-3143, 2005.
    • (2005) Med. Phys. , vol.32 , pp. 3136-3143
    • Zhu, J.1    Zhao, S.2    Ye, Y.3    Wang, G.4
  • 64
    • 8344247891 scopus 로고    scopus 로고
    • Integrating kinetic models for simulating tumor growth in Monte Carlo simulation of ECT systems
    • J. Peter and W. Semmler, "Integrating kinetic models for simulating tumor growth in Monte Carlo simulation of ECT systems" IEEE Trans. Nucl. Sci., vol. 51, pp. 2628-2633, 2004.
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , pp. 2628-2633
    • Peter, J.1    Semmler, W.2
  • 65
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography-an increasing source of radiation exposure
    • D. J. Brenner and E. J. Hall, "Computed tomography-an increasing source of radiation exposure" New Eng. J. Med., vol. 357, pp. 2277-2784, 2007.
    • (2007) New Eng. J. Med. , vol.357 , pp. 2277-2784
    • Brenner, D.J.1    Hall, E.J.2
  • 69
    • 33745496524 scopus 로고    scopus 로고
    • X-ray computed tomography
    • W. A. Kalender, "X-ray computed tomography" Phys. Med. Biol., vol. 51, pp. R29-R43, 2006.
    • (2006) Phys. Med. Biol. , vol.51
    • Kalender, W.A.1
  • 70
    • 33750301937 scopus 로고    scopus 로고
    • Multidetector CT: Opportunities, challenges, and concerns associated with scanners with 64 or more detector rows
    • J. M. Boone, "Multidetector CT: Opportunities, challenges, and concerns associated with scanners with 64 or more detector rows" Radiology, vol. 241, pp. 334-337, 2006.
    • (2006) Radiology , vol.241 , pp. 334-337
    • Boone, J.M.1
  • 71
    • 0003414651 scopus 로고
    • Photon electron, proton and neutron interaction data for body tissues
    • ICRU Bethesda, MD
    • ICRU, "Photon, electron, proton and neutron interaction data for body tissues" Bethesda, MD, ICRU Rep. 46, 1992.
    • (1992) ICRU Rep , vol.46
  • 72
    • 0038413486 scopus 로고    scopus 로고
    • Basic anatomical and physiological data for use in radiological protection: Reference values
    • ICRP
    • ICRP, "Basic anatomical and physiological data for use in radiological protection: Reference values" Ann. ICRP, vol. 32, pp. 1-277, 2002.
    • (2002) Ann. ICRP , vol.32 , pp. 1-277
  • 74
    • 48349133177 scopus 로고    scopus 로고
    • HDRK-Man: A whole-body voxel model based on high-resolution color slice images of a Korean adult male cadaver
    • C. H. Kim, S. H. Choi, J. H. Jeong, C.Lee, and M. S. Chung, "HDRK-Man: A whole-body voxel model based on high-resolution color slice images of a Korean adult male cadaver" Phys. Med. Biol., vol. 53, pp. 4093-4106, 2008.
    • (2008) Phys. Med. Biol. , vol.53 , pp. 4093-4106
    • Kim, C.H.1    Choi, S.H.2    Jeong, J.H.3    Lee, C.4    Chung, M.S.5
  • 75
    • 0034110635 scopus 로고    scopus 로고
    • VIP-Man: An image-based whole-body adult male model constructed from color photographs of the Visible Human Project for multi-particle Monte Carlo calculations
    • X. G. Xu, T. C. Chao, and A. Bozkurt, "VIP-Man: An image-based whole-body adult male model constructed from color photographs of the Visible Human Project for multi-particle Monte Carlo calculations" Health Phys., vol. 78, pp. 476-486, 2000.
    • (2000) Health Phys. , vol.78 , pp. 476-486
    • Xu, X.G.1    Chao, T.C.2    Bozkurt, A.3
  • 76
    • 0031700544 scopus 로고    scopus 로고
    • The Visible Human Dataset: The anatomical platform for human simulation
    • V. M. Spitzer and D. G. Whitlock, "The Visible Human Dataset: The anatomical platform for human simulation" Anat. Rec., vol. 253, pp. 49-57, 1998.
    • (1998) Anat. Rec. , vol.253 , pp. 49-57
    • Spitzer, V.M.1    Whitlock, D.G.2
  • 79
    • 0022698166 scopus 로고
    • The calculation of dose from external photon exposures using reference and realistic human phantoms and Monte Carlo methods
    • G. Williams, M. Zankl, W. Abmayr, R. Veit, and G. Drexler, "The calculation of dose from external photon exposures using reference and realistic human phantoms and Monte Carlo methods" Phys. Med. Biol., vol. 31, pp. 449-452, 1986.
    • (1986) Phys. Med. Biol. , vol.31 , pp. 449-452
    • Williams, G.1    Zankl, M.2    Abmayr, W.3    Veit, R.4    Drexler, G.5
  • 80
    • 0024383816 scopus 로고
    • Dose equivalents in anthropomorphic phantoms and their relation to the ambient dose equivalent H * (10) for external exposure
    • R. Veit, M. Zankl, N. Petoussi, and G. Drexler, "Dose equivalents in anthropomorphic phantoms and their relation to the ambient dose equivalent H * (10) for external exposure" Radiat. Prot. Dosim., vol. 28, pp. 29-32, 1989.
    • (1989) Radiat. Prot. Dosim. , vol.28 , pp. 29-32
    • Veit, R.1    Zankl, M.2    Petoussi, N.3    Drexler, G.4
  • 81
    • 0000357029 scopus 로고
    • Vergleich berechneter und gemessener Dosen an einem anthropomorphen phantom
    • R. Veit, W. Panzer, M. Zankl, and C.Scheurer, "Vergleich berechneter und gemessener Dosen an einem anthropomorphen phantom" Z Med. Phys., vol. 2, pp. 123-126, 1992.
    • (1992) Z Med. Phys. , vol.2 , pp. 123-126
    • Veit, R.1    Panzer, W.2    Zankl, M.3    Scheurer, C.4
  • 82
    • 0034959155 scopus 로고    scopus 로고
    • The adult male voxel model 'Golem' segmented from whole-body CT patient data
    • M. Zankl and A. Wittmann, "The adult male voxel model 'Golem' segmented from whole-body CT patient data" Radiat. Environ. Biophys., vol. 40, pp. 153-162, 2001.
    • (2001) Radiat. Environ. Biophys. , vol.40 , pp. 153-162
    • Zankl, M.1    Wittmann, A.2
  • 84
    • 0025416077 scopus 로고
    • 3-D phantom to simulate cerebral blood flow and metabolic images for PET
    • E. J. Hoffman, P. D. Cutler, W. M. Digby, and J. C. Mazziotta, B3-D phantom to simulate cerebral blood flow and metabolic images for PET" IEEE Trans. Nucl. Sci., vol. 37, pp. 616-620, 1990.
    • (1990) IEEE Trans. Nucl. Sci. , vol.37 , pp. 616-620
    • Hoffman, E.J.1    Cutler, P.D.2    Digby, W.M.3    Mazziotta, J.C.4
  • 85
    • 0026055761 scopus 로고
    • Three-dimensional SPECT simulations of a complex three-dimensional mathematical brain model and measurements of the three-dimensional physical brain phantom
    • J. Kim, B. R. Zeeberg, F. H. Fahey, A. N. Bice, E. J. Hoffman, and R. C. Reba, "Three-dimensional SPECT simulations of a complex three-dimensional mathematical brain model and measurements of the three-dimensional physical brain phantom" J. Nucl. Med., vol. 32, pp. 1923-1930, 1991.
    • (1991) J. Nucl. Med. , vol.32 , pp. 1923-1930
    • Kim, J.1    Zeeberg, B.R.2    Fahey, F.H.3    Bice, A.N.4    Hoffman, E.J.5    Reba, R.C.6
  • 86
    • 0031456349 scopus 로고    scopus 로고
    • A comparison of 60 Hz uniform magnetic and electric induction in the human body
    • T. W. Dawson, K. Caputa, and M. A. Stuchly, "A comparison of 60 Hz uniform magnetic and electric induction in the human body" Phys. Med. Biol., vol. 42, pp. 2319-2329, 1997.
    • (1997) Phys. Med. Biol. , vol.42 , pp. 2319-2329
    • Dawson, T.W.1    Caputa, K.2    Stuchly, M.A.3
  • 87
    • 0034786342 scopus 로고    scopus 로고
    • Registration of emission and transmission whole-body scintillation-camera images
    • K. Sjogreen, M. Ljungberg, K. Wingardh, K. Erlandsson, and S. E. Strand, "Registration of emission and transmission whole-body scintillation-camera images" J. Nucl. Med., vol. 42, pp. 1563-1570, 2001.
    • (2001) J. Nucl. Med. , vol.42 , pp. 1563-1570
    • Sjogreen, K.1    Ljungberg, M.2    Wingardh, K.3    Erlandsson, K.4    Strand, S.E.5
  • 88
    • 0038459031 scopus 로고    scopus 로고
    • All about MAX: A male adult voxel phantom for Monte Carlo calculations in radiation protection dosimetry
    • R. Kramer, J. W. Vieira, H. J. Khoury, F. R. Lima, and D. Fuelle, "All about MAX: A male adult voxel phantom for Monte Carlo calculations in radiation protection dosimetry" Phys. Med. Biol., vol. 48, pp. 1239-1262, 2003.
    • (2003) Phys. Med. Biol. , vol.48 , pp. 1239-1262
    • Kramer, R.1    Vieira, J.W.2    Khoury, H.J.3    Lima, F.R.4    Fuelle, D.5
  • 89
    • 11044227792 scopus 로고    scopus 로고
    • All about FAX: A Female adult voxel phantom for Monte Carlo calculation in radiation protection dosimetry
    • R. Kramer, H. J. Khoury, J. W. Vieira, E.C. M. Loureiro, V. J. M. Lima, F.R. A. Lima, and G. Hoff, "All about FAX: A Female adult voxel phantom for Monte Carlo calculation in radiation protection dosimetry" Phys. Med. Biol., vol. 49, pp. 5203-5216, 2004.
    • (2004) Phys. Med. Biol. , vol.49 , pp. 5203-5216
    • Kramer, R.1    Khoury, H.J.2    Vieira, J.W.3    Loureiro, M.E.C.4    Lima, V.J.M.5    Lima, A.F.R.6    Hoff, G.7
  • 90
    • 0030939916 scopus 로고    scopus 로고
    • FDTD calculations of the whole-body averaged SAR in an anatomically realistic voxel model of the human body from 1 MHz to 1 GHz
    • P. J. Dimbylow, "FDTD calculations of the whole-body averaged SAR in an anatomically realistic voxel model of the human body from 1 MHz to 1 GHz" Phys. Med. Biol., vol. 42, pp. 479-490, 1997.
    • (1997) Phys. Med. Biol. , vol.42 , pp. 479-490
    • Dimbylow, P.J.1
  • 91
    • 0037151333 scopus 로고    scopus 로고
    • Fine resolution calculations of SAR in the human body for frequencies up to 3 GHz
    • P. J. Dimbylow, "Fine resolution calculations of SAR in the human body for frequencies up to 3 GHz" Phys. Med. Biol., vol. 47, pp. 2835-2846, 2002.
    • (2002) Phys. Med. Biol. , vol.47 , pp. 2835-2846
    • Dimbylow, P.J.1
  • 92
    • 0030869733 scopus 로고    scopus 로고
    • A realistic anthropomorphic phantom for calculating organ doses arising from external photon irradiation
    • D. G. Jones, "A realistic anthropomorphic phantom for calculating organ doses arising from external photon irradiation" Radiat. Prot. Dosim., vol. 72, pp. 21-29, 1997.
    • (1997) Radiat. Prot. Dosim. , vol.72 , pp. 21-29
    • Jones, D.G.1
  • 93
    • 16444369285 scopus 로고    scopus 로고
    • Development of the female voxel phantom, NAOMI, and its application to calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields
    • P. J. Dimbylow, "Development of the female voxel phantom, NAOMI, and its application to calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields" Phys. Med. Biol., vol. 50, pp. 1047-1070, 2005.
    • (2005) Phys. Med. Biol. , vol.50 , pp. 1047-1070
    • Dimbylow, P.J.1
  • 94
    • 1142303804 scopus 로고    scopus 로고
    • Adult female voxel models of different stature and photon conversion coefficients for radiation protection
    • U. A. Fill, M. Zankl, N. Petoussi-Henss, M. Siebert, and D. Regulla, "Adult female voxel models of different stature and photon conversion coefficients for radiation protection" Health Phys., vol. 86, pp. 253-272, 2004.
    • (2004) Health Phys. , vol.86 , pp. 253-272
    • Fill, U.A.1    Zankl, M.2    Petoussi-Henss, N.3    Siebert, M.4    Regulla, D.5
  • 95
    • 0023918593 scopus 로고
    • The construction of computer tomographic phantoms and their application in radiology and radiation protection
    • M. Zankl, R. Veit, G. Williams, K. Schneider, H. Fendel, N. Petoussi, and G. Drexler, "The construction of computer tomographic phantoms and their application in radiology and radiation protection" Radiat. Environ. Biophys., vol. 27, pp. 153-164, 1988.
    • (1988) Radiat. Environ. Biophys. , vol.27 , pp. 153-164
    • Zankl, M.1    Veit, R.2    Williams, G.3    Schneider, K.4    Fendel, H.5    Petoussi, N.6    Drexler, G.7
  • 96
    • 0032833602 scopus 로고    scopus 로고
    • An EGS4-ready tomographic computational model of a 14-year-old female torso for calculating organ doses from CT examinations
    • M. Caon, G. Bibbo, and J. Pattison, "An EGS4-ready tomographic computational model of a 14-year-old female torso for calculating organ doses from CT examinations" Phys. Med. Biol., vol. 44, pp. 2213-2225, 1999.
    • (1999) Phys. Med. Biol. , vol.44 , pp. 2213-2225
    • Caon, M.1    Bibbo, G.2    Pattison, J.3
  • 97
    • 0037037174 scopus 로고    scopus 로고
    • Creation of two tomographic voxel models of paediatric patients in the first year of life
    • J. C. Nipper, J. L. Williams, and W. E. Bolch, "Creation of two tomographic voxel models of paediatric patients in the first year of life" Phys. Med. Biol., vol. 47, pp. 3143-3164, 2002.
    • (2002) Phys. Med. Biol. , vol.47 , pp. 3143-3164
    • Nipper, J.C.1    Williams, J.L.2    Bolch, W.E.3
  • 98
    • 31844431612 scopus 로고    scopus 로고
    • The UF series of tomographic computational phantoms of pediatric patients
    • C. Lee, J. L. Williams, C. Lee, and W. Bolch, "The UF series of tomographic computational phantoms of pediatric patients" Med. Phys., vol. 32, pp. 3537-3548, 2005.
    • (2005) Med. Phys. , vol.32 , pp. 3537-3548
    • Lee, C.1    Williams, J.L.2    Lee, C.3    Bolch, W.4
  • 99
    • 33748557216 scopus 로고    scopus 로고
    • Whole-body voxel phantoms of paediatric patients-UF Series B
    • C. Lee, J. L. Williams, and W. E. Bolch, "Whole-body voxel phantoms of paediatric patients-UF Series B" Phys. Med. Biol., vol. 51, pp. 4649-4661, 2006.
    • (2006) Phys. Med. Biol. , vol.51 , pp. 4649-4661
    • Lee, C.1    Williams, J.L.2    Bolch, W.E.3
  • 101
    • 0037151130 scopus 로고    scopus 로고
    • Organ dose conversion coefficients for external photon irradiation of male and female voxel models
    • M. Zankl, U. Fill, N. Petoussi-Henss, and D.Regulla, "Organ dose conversion coefficients for external photon irradiation of male and female voxel models" Phys. Med. Biol., vol. 47, pp. 2367-2385, 2002.
    • (2002) Phys. Med. Biol. , vol.47 , pp. 2367-2385
    • Zankl, M.1    Fill, U.2    Petoussi-Henss, N.3    Regulla, D.4
  • 102
    • 0347093559 scopus 로고    scopus 로고
    • Development of realistic high-resolution whole-body voxel models of Japanese adult males and females of average height and weight, and application of models to radio-frequency electromagnetic-field dosimetry
    • T. Nagaoka, S. Watanabe, K. Sakurai, E.Kunieda, M. Taki, and Y. Yamanaka, "Development of realistic high-resolution whole-body voxel models of Japanese adult males and females of average height and weight, and application of models to radio-frequency electromagnetic-field dosimetry" Phys. Med. Biol., vol. 49, pp. 1-15, 2004.
    • (2004) Phys. Med. Biol. , vol.49 , pp. 1-15
    • Nagaoka, T.1    Watanabe, S.2    Sakurai, K.3    Kunieda, E.4    Taki, M.5    Yamanaka, Y.6
  • 103
    • 0035014195 scopus 로고    scopus 로고
    • Construction of a computed tomographic phantom for a Japanese male adult and dose calculation system
    • K. Saito, A. Wittmann, S. Koga, Y. Ida, T. Kamei, J. Funabiki, and M. Zankl, "Construction of a computed tomographic phantom for a Japanese male adult and dose calculation system" Radiat. Environ. Biophys., vol. 40, pp. 69-75, 2001.
    • (2001) Radiat. Environ. Biophys. , vol.40 , pp. 69-75
    • Saito, K.1    Wittmann, A.2    Koga, S.3    Ida, Y.4    Kamei, T.5    Funabiki, J.6    Zankl, M.7
  • 104
    • 34447300721 scopus 로고    scopus 로고
    • Japanese adult male voxel phantom constructed on the basis of CT images
    • K. Sato, H. Noguchi, Y. Emoto, S. Koga, and K. Saito, "Japanese adult male voxel phantom constructed on the basis of CT images" Radiat. Prot. Dosim., vol. 123, pp. 337-344, 2007.
    • (2007) Radiat. Prot. Dosim. , vol.123 , pp. 337-344
    • Sato, K.1    Noguchi, H.2    Emoto, Y.3    Koga, S.4    Saito, K.5
  • 105
    • 49649127707 scopus 로고    scopus 로고
    • Development of a voxel phantom of Japanese adult male in upright posture
    • K. Sato, H. Noguchi, A. Endo, Y. Emoto, S. Koga, and K. Saito, "Development of a voxel phantom of Japanese adult male in upright posture" Radiat. Prot. Dosim., vol. 127, pp. 205-208, 2007.
    • (2007) Radiat. Prot. Dosim. , vol.127 , pp. 205-208
    • Sato, K.1    Noguchi, H.2    Endo, A.3    Emoto, Y.4    Koga, S.5    Saito, K.6
  • 106
    • 2442659088 scopus 로고    scopus 로고
    • Korean adult male voxel model KORMAN segmented from magnetic resonance images
    • C. Lee and J. Lee, "Korean adult male voxel model KORMAN segmented from magnetic resonance images" Med. Phys., vol. 31, pp. 1017-1022, 2004.
    • (2004) Med. Phys. , vol.31 , pp. 1017-1022
    • Lee, C.1    Lee, J.2
  • 107
    • 19044377623 scopus 로고    scopus 로고
    • Visible Korean human: Improved serially sectioned images of the entire body
    • J. S. Park, M. S. Chung, S. B. Hwang, Y. S. Lee, D. H. Har, and H. S. Park, "Visible Korean human: Improved serially sectioned images of the entire body" IEEE Trans. Med. Imag., vol. 24, pp. 352-360, 2005.
    • (2005) IEEE Trans. Med. Imag. , vol.24 , pp. 352-360
    • Park, J.S.1    Chung, M.S.2    Hwang, S.B.3    Lee, Y.S.4    Har, D.H.5    Park, H.S.6
  • 108
    • 31844433735 scopus 로고    scopus 로고
    • Development of the two Korean adult tomographic computational phantoms for organ dosimetry
    • DOI 10.1118/1.2161405
    • C. Lee, S. H. Park, and J. K. Leec, "Development of the two Korean adult tomographic computational phantoms for organ dosimetry" Med. Phys., vol. 33, pp. 380-390, 2006. (Pubitemid 43183981)
    • (2006) Medical Physics , vol.33 , Issue.2 , pp. 380-390
    • Lee, C.1    Lee, C.2    Park, S.-H.3    Lee, J.-K.4
  • 109
    • 37449001436 scopus 로고    scopus 로고
    • CNMAN: A Chinese adult male voxel phantom constructed from color photographs of a visible anatomical data set
    • B. Zhang, J. Ma, L. Liu, and J. Cheng, "CNMAN: A Chinese adult male voxel phantom constructed from color photographs of a visible anatomical data set" Radiat. Prot. Dosim., vol. 124, pp. 130-136, 2007.
    • (2007) Radiat. Prot. Dosim. , vol.124 , pp. 130-136
    • Zhang, B.1    Ma, J.2    Liu, L.3    Cheng, J.4
  • 110
    • 47649121386 scopus 로고    scopus 로고
    • Organ dose calculations by Monte Carlo modeling of the updated VCH adult male phantom against idealized external proton exposure
    • G. Zhang, Q. Liu, S. Zeng, and Q. Luo, "Organ dose calculations by Monte Carlo modeling of the updated VCH adult male phantom against idealized external proton exposure" Phys. Med. Biol., vol. 53, pp. 3697-3722, 2008.
    • (2008) Phys. Med. Biol. , vol.53 , pp. 3697-3722
    • Zhang, G.1    Liu, Q.2    Zeng, S.3    Luo, Q.4
  • 111
    • 70450269684 scopus 로고    scopus 로고
    • ICRP Online
    • ICRP. (2002). Annual report of the ICRP. [Online]. Available: http://www.icrp.org/ docs/2002-Ann-Rep-52-429-03.pdf
    • (2002) Annual Report of the ICRP
  • 112
    • 34547134053 scopus 로고    scopus 로고
    • Voxel-based models representing the male and female ICRP reference adultVThe skeleton
    • M. Zankl, K. F. Eckerman, and W. E. Bolch, "Voxel-based models representing the male and female ICRP reference adultVThe skeleton" Radiat. Prot. Dosim., vol. 127, pp. 174-186, 2007.
    • (2007) Radiat. Prot. Dosim. , vol.127 , pp. 174-186
    • Zankl, M.1    Eckerman, K.F.2    Bolch, W.E.3
  • 113
    • 33745858712 scopus 로고    scopus 로고
    • MAX06 and FAX06: Update of two adult human phantoms for radiation protection dosimetry
    • R. Kramer, H. J. Khoury, J. W. Vieira, and V. J. M. Lima, "MAX06 and FAX06: Update of two adult human phantoms for radiation protection dosimetry" Phys. Med. Biol., vol. 51, pp. 3331-3346, 2006.
    • (2006) Phys. Med. Biol. , vol.51 , pp. 3331-3346
    • Kramer, R.1    Khoury, H.J.2    Vieira, J.W.3    Lima, V.J.M.4
  • 114
    • 24744451003 scopus 로고    scopus 로고
    • An improved MCNP version of the NORMAN voxel phantom for dosimetry studies
    • P. Ferrari and G. Gualdrini, "An improved MCNP version of the NORMAN voxel phantom for dosimetry studies" Phys. Med. Biol., vol. 50, pp. 4299-4316, 2005.
    • (2005) Phys. Med. Biol. , vol.50 , pp. 4299-4316
    • Ferrari, P.1    Gualdrini, G.2
  • 115
    • 4644279738 scopus 로고    scopus 로고
    • Development of a 30-week-pregnant female tomographic model from computed tomography (CT) images for Monte Carlo organ dose calculations
    • C. Y. Shi and X. G. Xu, "Development of a 30-week-pregnant female tomographic model from computed tomography (CT) images for Monte Carlo organ dose calculations" Med. Phys., vol. 31, pp. 2491-2497, 2004.
    • (2004) Med. Phys. , vol.31 , pp. 2491-2497
    • Shi, C.Y.1    Xu, X.G.2
  • 116
    • 35848951399 scopus 로고    scopus 로고
    • An anatomically realistic whole-body pregnant-woman model and specific absorption rates for pregnant-woman exposure to electromagnetic plane waves from 10 MHz to 2 GHz
    • T. Nagaoka, T. Togashi, K. Saito, M. Takahashi, K. Ito, and S. Watanabe, "An anatomically realistic whole-body pregnant-woman model and specific absorption rates for pregnant-woman exposure to electromagnetic plane waves from 10 MHz to 2 GHz" Phys. Med. Biol., vol. 52, pp. 6731-6745, 2007.
    • (2007) Phys. Med. Biol. , vol.52 , pp. 6731-6745
    • Nagaoka, T.1    Togashi, T.2    Saito, K.3    Takahashi, M.4    Ito, K.5    Watanabe, S.6
  • 117
    • 36348984478 scopus 로고    scopus 로고
    • A boundary-representation method for designing whole-body radiation dosimetry models: Pregnant females at the ends of three gestational periodsVRPI-P3,-P6 and-P9
    • X. G. Xu, V. Taranenko, J. Zhang, and C. Shi, "A boundary-representation method for designing whole-body radiation dosimetry models: Pregnant females at the ends of three gestational periodsVRPI-P3,-P6 and-P9" Phys. Med. Biol., vol. 52, pp. 7023-7044, 2007.
    • (2007) Phys. Med. Biol. , vol.52 , pp. 7023-7044
    • Xu, X.G.1    Taranenko, V.2    Zhang, J.3    Shi, C.4
  • 118
    • 14844337085 scopus 로고    scopus 로고
    • Specific absorbed fractions for internal photon emitters calculated for a tomographic model of a pregnant woman
    • C. Y. Shi, X. G. Xu, and M. G. Stabin, "Specific absorbed fractions for internal photon emitters calculated for a tomographic model of a pregnant woman" Health Phys., vol. 87, pp. 507-511, 2004.
    • (2004) Health Phys. , vol.87 , pp. 507-511
    • Shi, C.Y.1    Xu, X.G.2    Stabin, M.G.3
  • 119
    • 46149093720 scopus 로고    scopus 로고
    • SAF values for internal photon emitters calculated for the RPI-P pregnant-female models using Monte Carlo methods
    • C. Y. Shi, X. G. Xu, and M. G. Stabin, "SAF values for internal photon emitters calculated for the RPI-P pregnant-female models using Monte Carlo methods" Med. Phys., vol. 35, pp. 3215-3224, 2008.
    • (2008) Med. Phys. , vol.35 , pp. 3215-3224
    • Shi, C.Y.1    Xu, X.G.2    Stabin, M.G.3
  • 120
    • 70349581604 scopus 로고    scopus 로고
    • Introducing DeBRa: A detailed breast model for radiological studies
    • A. K. Ma, S. Gunn, and D. G. Darambara, "Introducing DeBRa: A detailed breast model for radiological studies" Phys. Med. Biol., vol. 54, pp. 4533-4545, 2009.
    • (2009) Phys. Med. Biol. , vol.54 , pp. 4533-4545
    • Ma, A.K.1    Gunn, S.2    Darambara, D.G.3
  • 121
    • 33947729160 scopus 로고    scopus 로고
    • A high-resolution anthropomorphic voxel-based tomographic phantom for proton therapy of the eye
    • A. A. Alghamdi, A. Ma, M. Marouli, Y. Albarakati, A. Kacperek, and N. M. Spyrou, "A high-resolution anthropomorphic voxel-based tomographic phantom for proton therapy of the eye" Phys. Med. Biol., vol. 52, pp. N51-N59, 2007.
    • (2007) Phys. Med. Biol. , vol.52
    • Alghamdi, A.A.1    Ma, A.2    Marouli, M.3    Albarakati, Y.4    Kacperek, A.5    Spyrou, N.M.6
  • 122
    • 33746094676 scopus 로고    scopus 로고
    • A new improved version of the realistic digital brain phantom
    • B. Aubert-Broche, A. C. Evans, and L. Collins, "A new improved version of the realistic digital brain phantom" NeuroImage, vol. 32, pp. 138-145, 2006.
    • (2006) NeuroImage , vol.32 , pp. 138-145
    • Aubert-Broche, B.1    Evans, A.C.2    Collins, L.3
  • 123
    • 5744242293 scopus 로고    scopus 로고
    • Design and simulation of a high-resolution stationary SPECT system for small animals
    • DOI 10.1088/0031-9155/49/19/009, PII S0031915504800356
    • F. J. Beekman and B. Vastenhouw, "Design and simulation of a high-resolution stationary SPECT system for small animals" Phys. Med. Biol., vol. 49, pp. 4579-4592, 2004. (Pubitemid 39378246)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.19 , pp. 4579-4592
    • Beekman, F.J.1    Vastenhouw, B.2
  • 124
    • 2942654916 scopus 로고    scopus 로고
    • Development of a 4-D digital mouse phantom for molecular imaging research
    • W. P. Segars, B. M. Tsui, E. C. Frey, G. A. Johnson, and S. S. Berr, "Development of a 4-D digital mouse phantom for molecular imaging research" Mol. Imag. Biol., vol. 6, pp. 149-159, 2004.
    • (2004) Mol. Imag. Biol. , vol.6 , pp. 149-159
    • Segars, W.P.1    Tsui, B.M.2    Frey, E.C.3    Johnson, G.A.4    Berr, S.S.5
  • 125
    • 16544385030 scopus 로고    scopus 로고
    • Evaluation of parameters influencing S values in mouse dosimetry
    • C. Hindorf, M. Ljungberg, and S. E. Strand, "Evaluation of parameters influencing S values in mouse dosimetry" J. Nucl. Med., vol. 45, pp. 1960-1965, 2004.
    • (2004) J. Nucl. Med. , vol.45 , pp. 1960-1965
    • Hindorf, C.1    Ljungberg, M.2    Strand, S.E.3
  • 126
    • 33745097234 scopus 로고    scopus 로고
    • Voxel-based mouse and rat models for internal dose calculations
    • M. G. Stabin, T. E. Peterson, G. E. Holburn, and M. A. Emmons, "Voxel-based mouse and rat models for internal dose calculations" J. Nucl. Med., vol. 47, pp. 655-659, 2006.
    • (2006) J. Nucl. Med. , vol.47 , pp. 655-659
    • Stabin, M.G.1    Peterson, T.E.2    Holburn, G.E.3    Emmons, M.A.4
  • 127
    • 34047257833 scopus 로고    scopus 로고
    • Digimouse: A 3D whole body mouse atlas from CT and cryosection data
    • B. Dogdas, D. Stout, A. F. Chatziioannou, and R. M. Leahy, "Digimouse: A 3D whole body mouse atlas from CT and cryosection data" Phys. Med. Biol., vol. 52, pp. 577-587, 2007.
    • (2007) Phys. Med. Biol. , vol.52 , pp. 577-587
    • Dogdas, B.1    Stout, D.2    Chatziioannou, A.F.3    Leahy, R.M.4
  • 128
    • 31044442530 scopus 로고    scopus 로고
    • Monte Carlo simulations of dose from microCT imaging procedures in a realistic mouse phantom
    • R. Taschereau, P. L. Chow, and A. F. Chatziioannou, "Monte Carlo simulations of dose from microCT imaging procedures in a realistic mouse phantom" Med. Phys., vol. 33, pp. 216-224, 2006.
    • (2006) Med. Phys. , vol.33 , pp. 216-224
    • Taschereau, R.1    Chow, P.L.2    Chatziioannou, A.F.3
  • 131
    • 48349118046 scopus 로고    scopus 로고
    • An image-based rat model for Monte Carlo organ dose calculations
    • L. Wu, G. Zhang, Q. Luo, and Q. Liu, "An image-based rat model for Monte Carlo organ dose calculations" Med. Phys., vol. 35, pp. 3759-3764, 2008.
    • (2008) Med. Phys. , vol.35 , pp. 3759-3764
    • Wu, L.1    Zhang, G.2    Luo, Q.3    Liu, Q.4
  • 132
    • 70450226710 scopus 로고    scopus 로고
    • The development of hybrid equation-voxel mouse model for Monte Carlo dose calculations
    • Dec.
    • T. Xie, W. Sun, Q. Luo, and Q. Liu, "The development of hybrid equation-voxel mouse model for Monte Carlo dose calculations" Proc. IEEE, vol. 97, no. 12, Dec. 2009.
    • (2009) Proc. IEEE , vol.97 , Issue.12
    • Xie, T.1    Sun, W.2    Luo, Q.3    Liu, Q.4
  • 133
    • 55749110403 scopus 로고    scopus 로고
    • Voxel-based frog phantom for internal dose evaluation
    • S. Kinase, "Voxel-based frog phantom for internal dose evaluation" J. Nucl. Sci. Technol., vol. 45, pp. 1049-1052, 2008.
    • (2008) J. Nucl. Sci. Technol. , vol.45 , pp. 1049-1052
    • Kinase, S.1
  • 134
    • 40449093971 scopus 로고    scopus 로고
    • Canine anatomic phantom for preclinical dosimetry in internal emitter therapy
    • L. Padilla, C. Lee, R. Milner, A. Shahlaee, and W. E. Bolch, "Canine anatomic phantom for preclinical dosimetry in internal emitter therapy" J. Nucl. Med., vol. 49, pp. 446-452, 2008.
    • (2008) J. Nucl. Med. , vol.49 , pp. 446-452
    • Padilla, L.1    Lee, C.2    Milner, R.3    Shahlaee, A.4    Bolch, W.E.5
  • 136
    • 58149263227 scopus 로고    scopus 로고
    • Postured voxel-based human models for electromagnetic dosimetry
    • T. Nagaoka and S. Watanabe, "Postured voxel-based human models for electromagnetic dosimetry" Phys. Med. Biol., vol. 53, pp. 7047-7061, 2008.
    • (2008) Phys. Med. Biol. , vol.53 , pp. 7047-7061
    • Nagaoka, T.1    Watanabe, S.2
  • 137
    • 70450230515 scopus 로고    scopus 로고
    • Voxel-based variable posture models of human anatomy
    • Dec.
    • T. Nagaoka, "Voxel-based variable posture models of human anatomy" Proc. IEEE, vol. 97, no. 12, Dec. 2009.
    • (2009) Proc. IEEE , vol.97 , Issue.12
    • Nagaoka, T.1
  • 139
    • 70450162884 scopus 로고    scopus 로고
    • Tsui BMCAT to XCAT: The evolution of 4-D computerized phantoms for imaging research
    • Dec.
    • W. P. Segars and B. M. W. Tsui, "MCAT to XCAT: The evolution of 4-D computerized phantoms for imaging research" Proc. IEEE, vol. 97, no. 12, Dec. 2009.
    • (2009) Proc. IEEE , vol.97 , Issue.12
    • Segars, W.P.1
  • 140
    • 33845596247 scopus 로고    scopus 로고
    • Normal and pathological NCAT image and phantom data based on physiologically realistic left ventricle finite-element models
    • A. I. Veress, W. P. Segars, J. A. Weiss, B. M. W. Tsui, and G. T. Gullberg, "Normal and pathological NCAT image and phantom data based on physiologically realistic left ventricle finite-element models" IEEE Trans. Med. Imag., vol. 25, pp. 1604-1616, 2006.
    • (2006) IEEE Trans. Med. Imag. , vol.25 , pp. 1604-1616
    • Veress, A.I.1    Segars, W.P.2    Weiss, J.A.3    Tsui, B.M.W.4    Gullberg, G.T.5
  • 141
    • 70450229895 scopus 로고    scopus 로고
    • Segmentation of heterogeneous tumors in PET using a novel fuzzy C-means algorithm abstract
    • S. Belhassen and H. Zaidi, "Segmentation of heterogeneous tumors in PET using a novel fuzzy C-means algorithm abstract" J. Nucl. Med., vol. 50, p. 286P, 2009.
    • (2009) J. Nucl. Med. , vol.50
    • Belhassen, S.1    Zaidi, H.2
  • 143
    • 0034178290 scopus 로고    scopus 로고
    • Analytical versus voxelized phantom representation for Monte Carlo simulation in radiological imaging
    • J. Peter, M. P. Tornai, and R. J. Jaszczek, "Analytical versus voxelized phantom representation for Monte Carlo simulation in radiological imaging" IEEE Trans. Med. Imag., vol. 19, pp. 556-564, 2000.
    • (2000) IEEE Trans. Med. Imag. , vol.19 , pp. 556-564
    • Peter, J.1    Tornai, M.P.2    Jaszczek, R.J.3
  • 144
    • 0036120688 scopus 로고    scopus 로고
    • Effect of phantom voxelization in CT simulations
    • A. L. Goertzen, F. J. Beekman, and S. R. Cherry, "Effect of phantom voxelization in CT simulations" Med. Phys., vol. 29, pp. 492-498, 2002.
    • (2002) Med. Phys. , vol.29 , pp. 492-498
    • Goertzen, A.L.1    Beekman, F.J.2    Cherry, S.R.3
  • 145
    • 38049154949 scopus 로고    scopus 로고
    • NURBS-based 3-D anthropomorphic computational phantoms for radiation dosimetry applications
    • C. Lee, D. Lodwick, and W. E. Bolch, "NURBS-based 3-D anthropomorphic computational phantoms for radiation dosimetry applications" Radiat. Prot. Dosim., vol. 127, pp. 227-232, 2007.
    • (2007) Radiat. Prot. Dosim. , vol.127 , pp. 227-232
    • Lee, C.1    Lodwick, D.2    Bolch, W.E.3
  • 146
    • 48349124497 scopus 로고    scopus 로고
    • Realistic CT simulation using the 4D XCAT phantom
    • W. P. Segars, M. Mahesh, T. J. Beck, E. C. Frey, and B. M. W. Tsui, "Realistic CT simulation using the 4D XCAT phantom" Med. Phys., vol. 35, pp. 3800-3808, 2008.
    • (2008) Med. Phys. , vol.35 , pp. 3800-3808
    • Segars, W.P.1    Mahesh, M.2    Beck, T.J.3    Frey, E.C.4    Tsui, B.M.W.5
  • 147
    • 70450268775 scopus 로고    scopus 로고
    • Hybrid computational phantoms representing the reference adult male and adult female: Construction and applications to retrospective dosimetry
    • in press
    • J. L. Hurtado, C. Lee, D. Lodwick, T. Geode, J. L. Williams, and W. E. Bolch, "Hybrid computational phantoms representing the reference adult male and adult female: Construction and applications to retrospective dosimetry" Health Phys., 2009, in press.
    • (2009) Health Phys.
    • Hurtado, J.L.1    Lee, C.2    Lodwick, D.3    Geode, T.4    Williams, J.L.5    Bolch, W.E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.